메뉴 건너뛰기




Volumn 13, Issue 6, 2008, Pages

Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo

Author keywords

Diffuse reflectance spectroscopy; Spectral imaging

Indexed keywords

DIFFUSE REFLECTANCE SPECTROSCOPY; HIGH SENSITIVITY; IN-VIVO; INVERSE MONTE CARLO; LIGHT COLLECTION EFFICIENCY; SCATTERING CO-EFFICIENT; SPECTRAL IMAGING; SPECTRAL IMAGING SYSTEM; TISSUE ABSORPTION; TISSUE OPTICAL PROPERTIES; TISSUE SURFACE;

EID: 62449230776     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3041500     Document Type: Article
Times cited : (43)

References (11)
  • 1
    • 16544379497 scopus 로고    scopus 로고
    • Spectroscopic sensing of cancer and cancer therapy: Current status of translational research
    • I. J. Bigio and S. G. Bown, "Spectroscopic sensing of cancer and cancer therapy, current status of translational research", Cancer Biother 3(3), 259-267 (2004). (Pubitemid 41350877)
    • (2004) Cancer Biology and Therapy , vol.3 , Issue.3 , pp. 259-267
    • Bigio, I.J.1    Bown, S.G.2
  • 5
    • 24744465656 scopus 로고    scopus 로고
    • Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer
    • C. Zhu, G. M. Palmer, T. M. Breslin, F. Xu, and N. Ramanujam, "Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer", J. Biomed. Opt. 10(2), 024032 (2005).
    • (2005) J. Biomed. Opt. , vol.10 , Issue.2 , pp. 024032
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Xu, F.4    Ramanujam, N.5
  • 6
    • 33645157161 scopus 로고    scopus 로고
    • Monte Carlo-based inverse model for calculating tissue optical properties. Part I, Theory and validation on synthetic phantoms
    • G. M. Palmer and N. Ramanujam, "Monte Carlo-based inverse model for calculating tissue optical properties. Part I, Theory and validation on synthetic phantoms", Appl. Opt. 45(5), 1062-1071 (2006).
    • (2006) Appl. Opt. , vol.45 , Issue.5 , pp. 1062-1071
    • Palmer, G.M.1    Ramanujam, N.2
  • 7
    • 33748056820 scopus 로고    scopus 로고
    • Diagnosis of breast cancer using diffuse reflectance spectroscopy: Comparison of a Monte Carlo versus partial least squares analysis based feature extraction technique
    • DOI 10.1002/lsm.20356
    • C. Zhu, G. M. Palmer, T. M. Breslin, J. Harter, and N. Ramanujam, "Diagnosis of breast cancer using diffuse reflectance spectroscopy: comparison of a Monte Carlo versus partial least squares analysis based feature extraction technique", Lasers Surg. Med. 38(7), 714-724 (2006). (Pubitemid 44300946)
    • (2006) Lasers in Surgery and Medicine , vol.38 , Issue.7 , pp. 714-724
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Harter, J.4    Ramanujam, N.5
  • 8
    • 33751312072 scopus 로고    scopus 로고
    • In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy
    • A. Cerussi, N. Shah, D. Hsiang, A. Durkin, J. Butler, and B. J. Tromberg, "In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy", J. Biomed. Opt. 11(4), 044005 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.4 , pp. 044005
    • Cerussi, A.1    Shah, N.2    Hsiang, D.3    Durkin, A.4    Butler, J.5    Tromberg, B.J.6
  • 9
    • 0023916085 scopus 로고
    • A portable reflectometer for the rapid quantification of cutaneous haemoglobin and melanin
    • J. W. Feather, D. J. Ellis, and G. Leslie, "A portable reflectometer for the rapid quantification of cutaneous haemoglobin and melanin", Phys. Med. Biol. 33(6), 711-722 (1988).
    • (1988) Phys. Med. Biol. , vol.33 , Issue.6 , pp. 711-722
    • Feather, J.W.1    Ellis, D.J.2    Leslie, G.3