메뉴 건너뛰기




Volumn 78, Issue 10, 2012, Pages 1101-1108

Comparison of transpulmonary thermodilution, transthoracic echocardiography and conventional hemodynamic monitoring in neonates and infants after open heart surgery: A preliminary study

Author keywords

Echocardiography; Hemodynamics; Pediatrics; Termodilution

Indexed keywords

ARTICLE; CENTRAL VENOUS PRESSURE; CLINICAL ARTICLE; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HEART INDEX; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART PRELOAD; HEART RIGHT VENTRICLE ENDDIASTOLIC VOLUME; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; INFANT; INTERMETHOD COMPARISON; MALE; NEWBORN; OPEN HEART SURGERY; PROSPECTIVE STUDY; THERMODILUTION; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 84870168556     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (29)
  • 2
    • 17444418624 scopus 로고    scopus 로고
    • Clinical assessment of cardiac performance in infants and children following cardiac surgery
    • Egan JR, Festa M, Cole AD, Nunn GR, Gillis J, Winlaw DS. Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Med 2005;31:568-573.
    • (2005) Intensive Care Med , vol.31 , pp. 568-573
    • Egan, J.R.1    Festa, M.2    Cole, A.D.3    Nunn, G.R.4    Gillis, J.5    Winlaw, D.S.6
  • 3
    • 0031471719 scopus 로고    scopus 로고
    • Clinicians' abilities to estimate cardiac index in ventilated children and infants
    • Tibby SM, Hatherill M, Marsh MJ, Murdoch IA. Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 1997;77:516-518.
    • (1997) Arch Dis Child , vol.77 , pp. 516-518
    • Tibby, S.M.1    Hatherill, M.2    Marsh, M.J.3    Murdoch, I.A.4
  • 4
    • 33845769558 scopus 로고    scopus 로고
    • Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery
    • Fakler U, Pauli CH, Balling G, Lorenz HP, Eicken A, Hennig M. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Torac Cardiovasc Surg 2007;133:224-228.
    • (2007) J Torac Cardiovasc Surg , vol.133 , pp. 224-228
    • Fakler, U.1    Pauli, C.H.2    Balling, G.3    Lorenz, H.P.4    Eicken, A.5    Hennig, M.6
  • 5
    • 43549103778 scopus 로고    scopus 로고
    • Transpulmonary thermodilution: Fnally, a gold standard for pediatric cardiac output measurement
    • Tibby S. Transpulmonary thermodilution: fnally, a gold standard for pediatric cardiac output measurement. Pediatr Crit Care Med 2008;9:341-342.
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 341-342
    • Tibby, S.1
  • 6
    • 33645765167 scopus 로고    scopus 로고
    • Correlation between cardiac output measured by the femoral arterial thermodilution technique pulmonary arterial and that measured by contour pulse analysis in a pediatric animal model
    • Lopez-Herce J, Ruperez M, Sanchez C, Garcia C, Garcia E. Correlation between cardiac output measured by the femoral arterial thermodilution technique pulmonary arterial and that measured by contour pulse analysis in a pediatric animal model J Clin Monit Comput 2006;20:19-23.
    • (2006) J Clin Monit Comput , vol.20 , pp. 19-23
    • Lopez-Herce, J.1    Ruperez, M.2    Sanchez, C.3    Garcia, C.4    Garcia, E.5
  • 7
    • 79959504640 scopus 로고    scopus 로고
    • Reply to: Limitations of volumetric indices obtained by transthoracic thermodilution
    • Della Rocca G, Teboul JL. Reply to: limitations of volumetric indices obtained by transthoracic thermodilution Minerva Anestesiol 2011;77:754-755.
    • (2011) Minerva Anestesiol , vol.77 , pp. 754-755
    • della Rocca, G.1    Teboul, J.L.2
  • 8
    • 0036020297 scopus 로고    scopus 로고
    • Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
    • Pauli C, Fakler U, Genz T, Hennig M, Lorenz H P, Hess J. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med 2002;28:947-952.
    • (2002) Intensive Care Med , vol.28 , pp. 947-952
    • Pauli, C.1    Fakler, U.2    Genz, T.3    Hennig, M.4    Lorenz, H.P.5    Hess, J.6
  • 9
    • 0030696028 scopus 로고    scopus 로고
    • Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
    • Tibby SM, Hatherill M, Marsh MJ, Wilson P, Postle AD, Murdoch IA. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants. Intensive Care Med 1997;23:987-991.
    • (1997) Intensive Care Med , vol.23 , pp. 987-991
    • Tibby, S.M.1    Hatherill, M.2    Marsh, M.J.3    Wilson, P.4    Postle, A.D.5    Murdoch, I.A.6
  • 10
    • 0029916814 scopus 로고    scopus 로고
    • A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients
    • McLuckie A, Murdoch IA, Marsh MJ, Anderson D. A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients. Acta Paediatr 1996;85:336-338.
    • (1996) Acta Paediatr , vol.85 , pp. 336-338
    • McLuckie, A.1    Murdoch, I.A.2    Marsh, M.J.3    Anderson, D.4
  • 11
    • 1342329574 scopus 로고    scopus 로고
    • Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model
    • Ruperez M, López-Herce J, Gárcia C, Sanchez C, Garcia E, Vigil D. Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model. Pediatric Cardiology 2004;25:119-123.
    • (2004) Pediatric Cardiology , vol.25 , pp. 119-123
    • Ruperez, M.1    López-Herce, J.2    Gárcia, C.3    Sanchez, C.4    Garcia, E.5    Vigil, D.6
  • 12
    • 0033787516 scopus 로고    scopus 로고
    • Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
    • Linton RA, Jonas MM, Tibby SM, Murdoch IA, O'Brien TK, Linton NWF et al. Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit. Intensive Care Med 2000;26:1507-1511.
    • (2000) Intensive Care Med , vol.26 , pp. 1507-1511
    • Linton, R.A.1    Jonas, M.M.2    Tibby, S.M.3    Murdoch, I.A.4    O'Brien, T.K.5    Linton, N.W.F.6
  • 13
    • 0033935864 scopus 로고    scopus 로고
    • Use of trans-esophageal Doppler ultrasonography in ventilated pediat-ric patients: Derivation of cardiac output
    • Tibby SM, Hatherill M, Murdoch IA. Use of trans-esophageal Doppler ultrasonography in ventilated pediat-ric patients: derivation of cardiac output. Crit Care Med 2000;28:2045-2050.
    • (2000) Crit Care Med , vol.28 , pp. 2045-2050
    • Tibby, S.M.1    Hatherill, M.2    Murdoch, I.A.3
  • 14
    • 43549092418 scopus 로고    scopus 로고
    • Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
    • Lemson J, de Boode WP, Hopman JC, Singh SK, van der Hoeven JG. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Pediatr Crit Care Med 2008;9:313-319.
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 313-319
    • Lemson, J.1    de Boode, W.P.2    Hopman, J.C.3    Singh, S.K.4    van der, H.J.G.5
  • 15
    • 19944420853 scopus 로고    scopus 로고
    • Volumetric preload measurement by thermodilution: A comparison with transoesophageal echo-cardiography
    • Hofer CK, Furrer L, Matter-Ensner S, Maloigne, Klagho-fer R, Genoni M et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echo-cardiography. Br J Anaesth 2005;94:748-755.
    • (2005) Br J Anaesth , vol.94 , pp. 748-755
    • Hofer, C.K.1    Furrer, L.2    Matter-Ensner, S.3    Maloigne4    Klagho-fer, R.5    Genoni, M.6
  • 16
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 2003;124:1900-1908.
    • (2003) Chest , vol.124 , pp. 1900-1908
    • Michard, F.1    Alaya, S.2    Zarka, V.3    Bahloul, M.4    Richard, C.5    Teboul, J.L.6
  • 17
    • 21644485259 scopus 로고    scopus 로고
    • Volumetric monitoring: Principles of application
    • Della Rocca G, Costa MG. Volumetric monitoring: principles of application. Minerva Anestesiol 2005;71:303-306.
    • (2005) Minerva Anestesiol , vol.71 , pp. 303-306
    • della Rocca, G.1    Costa, M.G.2
  • 18
    • 85058205177 scopus 로고    scopus 로고
    • Variation of left ventricular outfow tract velocity and global end-diastolic volume index reliably predict fuid responsiveness in cardiac surgery patients
    • Epub ahead of print
    • Broch O, Renner J, Gruenewald M, Meybohm P, Höcker J, Schöttler J et al. Variation of left ventricular outfow tract velocity and global end-diastolic volume index reliably predict fuid responsiveness in cardiac surgery patients. J Crit Care 2011 [Epub ahead of print].
    • (2011) J Crit Care
    • Broch, O.1    Renner, J.2    Gruenewald, M.3    Meybohm, P.4    Höcker, J.5    Schöttler, J.6
  • 19
    • 0036793048 scopus 로고    scopus 로고
    • Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmo-nary indicator dilution in critically ill neonates and infants
    • Schifmann H, Erdlenbruch B, Singer D, Singer S, Hert-ing E, Hoeft A. Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmo-nary indicator dilution in critically ill neonates and infants. J Cardiothorac Vasc Anesth 2002;16:592-597.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 592-597
    • Schifmann, H.1    Erdlenbruch, B.2    Singer, D.3    Singer, S.4    Hert-Ing, E.5    Hoeft, A.6
  • 20
    • 84055182994 scopus 로고    scopus 로고
    • Prediction of fuid responsivenesss in infants and neonates undergoing congenital heart surgery
    • Renner J, Broch O, Duetschke P, Scheewe J, Höker J, Moseby M et al. Prediction of fuid responsivenesss in infants and neonates undergoing congenital heart surgery. Br J Anaesth 2012;108:108-115.
    • (2012) Br J Anaesth , vol.108 , pp. 108-115
    • Renner, J.1    Broch, O.2    Duetschke, P.3    Scheewe, J.4    Höker, J.5    Moseby, M.6
  • 21
    • 33846323221 scopus 로고    scopus 로고
    • Goal-directed fuid management reduces vaso-pressor and catecholamine use in cardiac surgery patients
    • Goepfert MS, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz A. Goal-directed fuid management reduces vaso-pressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007;33:96-103.
    • (2007) Intensive Care Med , vol.33 , pp. 96-103
    • Goepfert, M.S.1    Reuter, D.A.2    Akyol, D.3    Lamm, P.4    Kilger, E.5    Goetz, A.6
  • 22
    • 0028789940 scopus 로고
    • Postoperative course and hemodynamic profle after the arterial switch operation in neonates. A comparison of low-fow cardiopulmonary bypass and circulatory arrest
    • Wernovsky G, Wypij D, Jonas RA, Mayer JE, Hanley FL, Hickey PR et al. Postoperative course and hemodynamic profle after the arterial switch operation in neonates. A comparison of low-fow cardiopulmonary bypass and circulatory arrest. Circulation 1995;92:2226-2235.
    • (1995) Circulation , vol.92 , pp. 2226-2235
    • Wernovsky, G.1    Wypij, D.2    Jonas, R.A.3    Mayer, J.E.4    Hanley, F.L.5    Hickey, P.R.6
  • 23
    • 77951732397 scopus 로고    scopus 로고
    • Recommendations for quantifcation methods during the performance of a pediatric echocar-diogram: A report from the pediatric measurements writing group of the american society of echocardiography pediatric and congenital heart disease council
    • Lopez L, Colan S, Frommelt P, Ensing GJ, Kendall K, Younoszai AK et al. Recommendations for quantifcation methods during the performance of a pediatric echocar-diogram: a report from the pediatric measurements writing group of the american society of echocardiography pediatric and congenital heart disease council. J Am Soc Echocar-diogr 2010;23:465-495.
    • (2010) J Am Soc Echocar-diogr , vol.23 , pp. 465-495
    • Lopez, L.1    Colan, S.2    Frommelt, P.3    Ensing, G.J.4    Kendall, K.5    Younoszai, A.K.6
  • 24
    • 44449116284 scopus 로고    scopus 로고
    • Relationship between global end-diastolic volume and cardiac output in critically ill infants and children
    • Cecchetti C, Lubrano R, Cristaldi S, Stoppa F, Barbieri MA, Elli M et al. Relationship between global end-diastolic volume and cardiac output in critically ill infants and children. Crit Care Med 2008;36:928-932.
    • (2008) Crit Care Med , vol.36 , pp. 928-932
    • Cecchetti, C.1    Lubrano, R.2    Cristaldi, S.3    Stoppa, F.4    Barbieri, M.A.5    Elli, M.6
  • 25
    • 20344405702 scopus 로고    scopus 로고
    • Pathophysiology of newborn hypotension outside the transitional period
    • Noori S, Seri I. Pathophysiology of newborn hypotension outside the transitional period. Early Hum Dev 2005;81:399-404.
    • (2005) Early Hum Dev , vol.81 , pp. 399-404
    • Noori, S.1    Seri, I.2
  • 26
    • 33744512099 scopus 로고    scopus 로고
    • Cardiovascular support of the sick neonate
    • Mupanemunda RH. Cardiovascular support of the sick neonate. Curr Pediatr 2006;16:176-181.
    • (2006) Curr Pediatr , vol.16 , pp. 176-181
    • Mupanemunda, R.H.1
  • 27
    • 79953117856 scopus 로고    scopus 로고
    • Assessment of left ventricular systolic function during acute myocardial ischaemia: A comparison of transpulmonary thermodilution and transesophageal echocardiography
    • Meybohm P, Gruenewald M, Renner J, Maracke M, Rossee S, Höcker J et al. Assessment of left ventricular systolic function during acute myocardial ischaemia: a comparison of transpulmonary thermodilution and transesophageal echocardiography. Minerva Anestesiol 2011;77:132-141.
    • (2011) Minerva Anestesiol , vol.77 , pp. 132-141
    • Meybohm, P.1    Gruenewald, M.2    Renner, J.3    Maracke, M.4    Rossee, S.5    Höcker, J.6
  • 29
    • 77956231366 scopus 로고    scopus 로고
    • Te normal ranges of cardiovascular parameters in children measured using the Ultrasonic Cardiac Output Monitor
    • Cattermole G, Leung M, Mak P, Chan S, Graham C, Rainer T. Te normal ranges of cardiovascular parameters in children measured using the Ultrasonic Cardiac Output Monitor. Crit Care Med 2010;38:1875-1881.
    • (2010) Crit Care Med , vol.38 , pp. 1875-1881
    • Cattermole, G.1    Leung, M.2    Mak, P.3    Chan, S.4    Graham, C.5    Rainer, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.