메뉴 건너뛰기




Volumn 77, Issue 7, 2011, Pages 754-755

Reply to: Limitations of volumetric indices obtained by transthoracic thermodilution

Author keywords

[No Author keywords available]

Indexed keywords

ESMOLOL; INOTROPIC AGENT; VASOACTIVE AGENT;

EID: 79959504640     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Letter
Times cited : (3)

References (13)
  • 1
    • 78649473914 scopus 로고    scopus 로고
    • Limitations of volumetric indices obtained by transthoracic thermodilution
    • Bigatello LM, Kistler EB, Noto A. Limitations of volumetric indices obtained by transthoracic thermodilution. Minerva Anestesiol 2010;76:945-9.
    • (2010) Minerva Anestesiol , vol.76 , pp. 945-949
    • Bigatello, L.M.1    Kistler, E.B.2    Noto, A.3
  • 2
    • 21644485259 scopus 로고    scopus 로고
    • Volumetric monitoring: Principles of application
    • Della Rocca G, Costa MG. Volumetric monitoring: principles of application. Minerva Anestesiol 2005;71:303-6.
    • (2005) Minerva Anestesiol , vol.71 , pp. 303-306
    • della Rocca, G.1    Costa, M.G.2
  • 3
    • 20444501790 scopus 로고    scopus 로고
    • Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients
    • Michard F, Schachtrupp A, Toens C. Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients. Crit Care Med 2005;33:1243-47.
    • (2005) Crit Care Med , vol.33 , pp. 1243-1247
    • Michard, F.1    Schachtrupp, A.2    Toens, C.3
  • 5
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anesth 2002; 88:350-6.
    • (2002) Br J Anesth , vol.88 , pp. 350-356
    • della Rocca, G.1    Costa, M.G.2    Pompei, L.3    Coccia, C.4    Pietropaoli, P.5
  • 6
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul J-L. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 2003;124:1900-8.
    • (2003) Chest , vol.124 , pp. 1900-1908
    • Michard, F.1    Alaya, S.2    Zarka, V.3    Bahloul, M.4    Richard, C.5    Teboul, J.-L.6
  • 7
    • 0034911132 scopus 로고    scopus 로고
    • Changes in cardiac output and intrathoracic blood volume: A mathematical coupling of data?
    • Buhre W, Kazmaierl S, Sonntag H, Weyland A. Changes in cardiac output and intrathoracic blood volume: a mathematical coupling of data? Acta Anaesthesiol Scand 2001;45:863-7.
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 863-867
    • Buhre, W.1    Kazmaierl, S.2    Sonntag, H.3    Weyland, A.4
  • 8
    • 3242699430 scopus 로고    scopus 로고
    • Estimation of left ventricular systolic function by single transpulmonary thermodilution
    • Combes A, Berneau J-B, Luyt C-E, Trouillet J-L. Estimation of left ventricular systolic function by single transpulmonary thermodilution. Intensive Care Med 2004;30:1377-83.
    • (2004) Intensive Care Med , vol.30 , pp. 1377-1383
    • Combes, A.1    Berneau, J.-B.2    Luyt, C.-E.3    Trouillet, J.-L.4
  • 9
    • 73449127209 scopus 로고    scopus 로고
    • Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function
    • Jabot J, Monnet X, Lamia B, Chemla D, Richard C, Teboul J-L. Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function. Crit Care Med 2009;37:2913-8.
    • (2009) Crit Care Med , vol.37 , pp. 2913-2918
    • Jabot, J.1    Monnet, X.2    Lamia, B.3    Chemla, D.4    Richard, C.5    Teboul, J.-L.6
  • 10
    • 0037302969 scopus 로고    scopus 로고
    • Clinical significance of pulmonary artery occlusion pressure
    • Pinsky MR. Clinical significance of pulmonary artery occlusion pressure. Intensive Care Med 2003;29:175-8.
    • (2003) Intensive Care Med , vol.29 , pp. 175-178
    • Pinsky, M.R.1
  • 11
  • 12
    • 77956489043 scopus 로고    scopus 로고
    • Validation of extravascular lung water measurement by single transpulmonary thermodilution: Human autopsy study
    • Tagami T, Kushimoto S, Yamamoto Y, Atsumi T, Tosa R, Matsuda K et al. Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study. Crit Care 2010;14:R162.
    • (2010) Crit Care , vol.14
    • Tagami, T.1    Kushimoto, S.2    Yamamoto, Y.3    Atsumi, T.4    Tosa, R.5    Matsuda, K.6
  • 13
    • 79959523025 scopus 로고    scopus 로고
    • Clinical review: Guyton: The role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output
    • Henderson WR, Griesdale DEG, Walley KR, Sheel AW. Clinical review: Guyton: the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output. Critical Care 2010;14:243.
    • (2010) Critical Care , vol.14 , pp. 243
    • Henderson, W.R.1    Griesdale, D.E.G.2    Walley, K.R.3    Sheel, A.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.