메뉴 건너뛰기




Volumn 9, Issue 3, 2008, Pages 341-342

Transpulmonary thermodilution: Finally, a gold standard for pediatric cardiac output measurement

Author keywords

Cardiac output; Pediatric; Thermodilution; Transpulmonary

Indexed keywords

DOBUTAMINE; HYPERTENSIVE FACTOR;

EID: 43549103778     PISSN: 15297535     EISSN: None     Source Type: Journal    
DOI: 10.1097/PCC.0b013e318172ea56     Document Type: Editorial
Times cited : (34)

References (13)
  • 1
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • S Sinclair S James M Singer Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial BMJ 315 1997 909 912
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S1    James, S2    Singer, M3
  • 2
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • E Rivers B Nguyen S Havstad Early goal-directed therapy in the treatment of severe sepsis and septic shock N Engl J Med 345 2001 1368 1377
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E1    Nguyen, B2    Havstad, S3
  • 3
    • 0028275095 scopus 로고
    • Elevation of systemic oxygen delivery in the treatment of critically ill patients
    • MA Hayes AC Timmins EH Yau Elevation of systemic oxygen delivery in the treatment of critically ill patients N Engl J Med 330 1994 1717 1722
    • (1994) N Engl J Med , vol.330 , pp. 1717-1722
    • Hayes, MA1    Timmins, AC2    Yau, EH3
  • 4
    • 0030696028 scopus 로고    scopus 로고
    • Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
    • SM Tibby M Hatherill MJ Marsh Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants Intensive Care Med 23 1997 987 991
    • (1997) Intensive Care Med , vol.23 , pp. 987-991
    • Tibby, SM1    Hatherill, M2    Marsh, MJ3
  • 5
    • 0036020297 scopus 로고    scopus 로고
    • Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
    • C Pauli U Fakler T Genz Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle Intensive Care Med 28 2002 947 952
    • (2002) Intensive Care Med , vol.28 , pp. 947-952
    • Pauli, C1    Fakler, U2    Genz, T3
  • 6
    • 43549092418 scopus 로고    scopus 로고
    • Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
    • J Lemson WP de Boode JCW Hopman Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model Pediatr Crit Care Med 9 2008 313 319
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 313-319
    • Lemson, J1    de Boode, WP2    Hopman, JCW3
  • 7
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • CW Stetz RG Miller GE Kelly Reliability of the thermodilution method in the determination of cardiac output in clinical practice Am Rev Respir Dis 126 1982 1001 1004
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, CW1    Miller, RG2    Kelly, GE3
  • 8
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • F Michard S Alaya V Zarka Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock Chest 124 2003 1900 1908
    • (2003) Chest , vol.124 , pp. 1900-1908
    • Michard, F1    Alaya, S2    Zarka, V3
  • 9
    • 33749743450 scopus 로고
    • The dye dilution method for describing the central circulation: An analysis of factors shaping the time-concentration curves
    • EV Newman M Merrell A Genecin The dye dilution method for describing the central circulation: An analysis of factors shaping the time-concentration curves Circulation 4 1951 735 746
    • (1951) Circulation , vol.4 , pp. 735-746
    • Newman, EV1    Merrell, M2    Genecin, A3
  • 10
    • 11144275267 scopus 로고    scopus 로고
    • Calculated global end-diastolic volume does not correspond to the largest heart blood volume: A bias for cardiac function index?
    • FG Brivet F Jacobs P Colin Calculated global end-diastolic volume does not correspond to the largest heart blood volume: A bias for cardiac function index? Intensive Care Med 30 2004 2133 2134
    • (2004) Intensive Care Med , vol.30 , pp. 2133-2134
    • Brivet, FG1    Jacobs, F2    Colin, P3
  • 11
    • 0027418731 scopus 로고
    • Measurement of cardiac chamber volumes by cine magnetic resonance imaging
    • H Matsuoka M Hamada T Honda Measurement of cardiac chamber volumes by cine magnetic resonance imaging Angiology 44 1993 321 327
    • (1993) Angiology , vol.44 , pp. 321-327
    • Matsuoka, H1    Hamada, M2    Honda, T3
  • 12
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    • B Bein P Meybohm E Cavus The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration Anesth Analg 105 2007 107 113
    • (2007) Anesth Analg , vol.105 , pp. 107-113
    • Bein, B1    Meybohm, P2    Cavus, E3
  • 13
    • 33749254838 scopus 로고    scopus 로고
    • Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume
    • SR Gunn HK Kim PW Harrigan Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume Intensive Care Med 32 2006 1537 1546
    • (2006) Intensive Care Med , vol.32 , pp. 1537-1546
    • Gunn, SR1    Kim, HK2    Harrigan, PW3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.