메뉴 건너뛰기




Volumn 56, Issue 2, 2012, Pages 93-101

Effect of thermal expansion mismatch on the Y-TZP/veneer interfacial adhesion determined by strain energy release rate

Author keywords

Bond strength; Residual stresses; Strain energy release rate; Thermal mismatch; Zirconia

Indexed keywords


EID: 84869890189     PISSN: 18831958     EISSN: 22124632     Source Type: Journal    
DOI: 10.1016/j.jpor.2011.09.002     Document Type: Article
Times cited : (40)

References (38)
  • 1
    • 38349192796 scopus 로고    scopus 로고
    • State of the art of zirconia for dental applications
    • Denry I., Kelly J.R. State of the art of zirconia for dental applications. Dent Mater 2008, 24:299-307.
    • (2008) Dent Mater , vol.24 , pp. 299-307
    • Denry, I.1    Kelly, J.R.2
  • 2
    • 35148891671 scopus 로고    scopus 로고
    • An overview of zirconia ceramics: basic properties and clinical applications
    • Manicone P.F., Iommetti P.R., Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent 2007, 35:819-826.
    • (2007) J Dent , vol.35 , pp. 819-826
    • Manicone, P.F.1    Iommetti, P.R.2    Raffaelli, L.3
  • 3
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: a systematic review
    • Conrad H.J., Seong W.J., Pesun I.J. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 2007, 98:389-404.
    • (2007) J Prosthet Dent , vol.98 , pp. 389-404
    • Conrad, H.J.1    Seong, W.J.2    Pesun, I.J.3
  • 4
    • 14844364021 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study
    • Vult von Steyern P.C., Nilner P.K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005, 32:180-187.
    • (2005) J Oral Rehabil , vol.32 , pp. 180-187
    • Vult von Steyern, P.C.1    Nilner, P.K.2
  • 5
    • 34250665803 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II. Fixed dental prostheses
    • Sailer I., Pjetursson B.E., Zwahlen M., Hammerle C.H. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II. Fixed dental prostheses. Clin Oral Implants Res 2007, 18(Suppl. 3):86-96.
    • (2007) Clin Oral Implants Res , vol.18 , Issue.SUPPL. 3 , pp. 86-96
    • Sailer, I.1    Pjetursson, B.E.2    Zwahlen, M.3    Hammerle, C.H.4
  • 7
    • 41849125937 scopus 로고    scopus 로고
    • Flexural strength of veneering ceramics for zirconia
    • Fischer J., Stawarczyk B., Hammerle C.H. Flexural strength of veneering ceramics for zirconia. J Dent 2008, 36:316-321.
    • (2008) J Dent , vol.36 , pp. 316-321
    • Fischer, J.1    Stawarczyk, B.2    Hammerle, C.H.3
  • 8
    • 59149095716 scopus 로고    scopus 로고
    • Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks
    • Fischer J., Stawarczyk B., Trottmann A., Hammerle C.H. Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks. Dent Mater 2009, 25:326-330.
    • (2009) Dent Mater , vol.25 , pp. 326-330
    • Fischer, J.1    Stawarczyk, B.2    Trottmann, A.3    Hammerle, C.H.4
  • 9
    • 43049090522 scopus 로고    scopus 로고
    • Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries
    • DeHoff P.H., Barrett A.A., Lee R.B., Anusavice K.J. Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries. Dent Mater 2008, 24:744-752.
    • (2008) Dent Mater , vol.24 , pp. 744-752
    • DeHoff, P.H.1    Barrett, A.A.2    Lee, R.B.3    Anusavice, K.J.4
  • 10
    • 60449083274 scopus 로고    scopus 로고
    • Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites
    • Fischer J., Stawarzcyk B., Trottmann A., Hammerle C.H. Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites. Dent Mater 2009, 25:419-423.
    • (2009) Dent Mater , vol.25 , pp. 419-423
    • Fischer, J.1    Stawarzcyk, B.2    Trottmann, A.3    Hammerle, C.H.4
  • 11
    • 0032106909 scopus 로고    scopus 로고
    • Thermal stresses in metal-ceramic specimens for the ISO crack initiation test (three-point flexure bond test)
    • Lenz J., Kessel S. Thermal stresses in metal-ceramic specimens for the ISO crack initiation test (three-point flexure bond test). Dent Mater 1998, 14:277-280.
    • (1998) Dent Mater , vol.14 , pp. 277-280
    • Lenz, J.1    Kessel, S.2
  • 12
    • 0025103078 scopus 로고
    • Metal ceramic compatibility: a review of the literature
    • Bagby M., Marshall S.J., Marshall G.W. Metal ceramic compatibility: a review of the literature. J Prosthet Dent 1990, 63:21-25.
    • (1990) J Prosthet Dent , vol.63 , pp. 21-25
    • Bagby, M.1    Marshall, S.J.2    Marshall, G.W.3
  • 14
    • 33746623731 scopus 로고    scopus 로고
    • Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II. Zirconia veneering ceramics
    • Aboushelib M.N., Kleverlaan C.J., Feilzer A.J. Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II. Zirconia veneering ceramics. Dent Mater 2006, 22:857-863.
    • (2006) Dent Mater , vol.22 , pp. 857-863
    • Aboushelib, M.N.1    Kleverlaan, C.J.2    Feilzer, A.J.3
  • 15
    • 38949113832 scopus 로고    scopus 로고
    • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns
    • Fischer J., Stawarczyk B., Tomic M., Strub J.R., Hammerle C.H. Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns. Dent Mater J 2007, 26:766-772.
    • (2007) Dent Mater J , vol.26 , pp. 766-772
    • Fischer, J.1    Stawarczyk, B.2    Tomic, M.3    Strub, J.R.4    Hammerle, C.H.5
  • 16
    • 33947375236 scopus 로고    scopus 로고
    • Comparison of two bond strength testing methodologies for bilayered all-ceramics
    • Dundar M., Ozcan M., Gokce B., Comlekoglu E., Leite F., Valandro L.F. Comparison of two bond strength testing methodologies for bilayered all-ceramics. Dent Mater 2007, 23:630-636.
    • (2007) Dent Mater , vol.23 , pp. 630-636
    • Dundar, M.1    Ozcan, M.2    Gokce, B.3    Comlekoglu, E.4    Leite, F.5    Valandro, L.F.6
  • 17
    • 4243558954 scopus 로고    scopus 로고
    • International Organisation of Standardisation, Genf, International Organisation of Standardisation (Ed.)
    • ISO 9693-metal-ceramic dental restaurative systems 1999, International Organisation of Standardisation, Genf. International Organisation of Standardisation (Ed.).
    • (1999) ISO 9693-metal-ceramic dental restaurative systems
  • 19
    • 0024621114 scopus 로고
    • A test specimen for determining the fracture resistance of bimaterial interfaces
    • Charalambides P.G., Lund J., Evans A.G., McMeeking R.M. A test specimen for determining the fracture resistance of bimaterial interfaces. J Appl Mech 1989, 56:77-82.
    • (1989) J Appl Mech , vol.56 , pp. 77-82
    • Charalambides, P.G.1    Lund, J.2    Evans, A.G.3    McMeeking, R.M.4
  • 20
    • 0033222608 scopus 로고    scopus 로고
    • New approach for evaluating metal-porcelain interfacial bonding
    • Suansuwan N., Swain M.V. New approach for evaluating metal-porcelain interfacial bonding. Int J Prosthodont 1999, 12:547-552.
    • (1999) Int J Prosthodont , vol.12 , pp. 547-552
    • Suansuwan, N.1    Swain, M.V.2
  • 21
    • 34248343497 scopus 로고    scopus 로고
    • Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate
    • Tholey M.J., Waddell J.N., Swain M.V. Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate. Dent Mater 2007, 23:822-828.
    • (2007) Dent Mater , vol.23 , pp. 822-828
    • Tholey, M.J.1    Waddell, J.N.2    Swain, M.V.3
  • 22
    • 33746308453 scopus 로고    scopus 로고
    • Influence of water, loading rate and bonder on the adhesion of porcelain to titanium
    • Homann F., Waddell J.N., Swain M.V. Influence of water, loading rate and bonder on the adhesion of porcelain to titanium. J Dent 2006, 34:485-490.
    • (2006) J Dent , vol.34 , pp. 485-490
    • Homann, F.1    Waddell, J.N.2    Swain, M.V.3
  • 24
    • 67349199548 scopus 로고    scopus 로고
    • Haftverbundmechanismen in dentalen Schichtsystemen
    • Tholey M.J., Stephan M. Bonding mechanisms in layered systems for dental use. Quintessenz Zahntech 2007, 33:160-168.
    • (2007) Quintessenz Zahntech , vol.33 , pp. 160-168
    • Tholey, M.J.1    Stephan, M.2
  • 25
    • 67349133480 scopus 로고    scopus 로고
    • Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
    • Swain M.V. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 2009, 5:1668-1677.
    • (2009) Acta Biomater , vol.5 , pp. 1668-1677
    • Swain, M.V.1
  • 26
    • 0001764380 scopus 로고
    • Analysis of bimetal thermostats
    • Timoshenko S. Analysis of bimetal thermostats. J Opt Soc Am 1925, 11:233-255.
    • (1925) J Opt Soc Am , vol.11 , pp. 233-255
    • Timoshenko, S.1
  • 27
    • 0003749418 scopus 로고
    • Press Syndicate of the University of Cambridge, Cambridge
    • Lawn B.R. Fracture of brittle solids 1993, Press Syndicate of the University of Cambridge, Cambridge.
    • (1993) Fracture of brittle solids
    • Lawn, B.R.1
  • 28
    • 77958110727 scopus 로고    scopus 로고
    • International Organisation of Standardisation, Genf, International Organisation of Standardisation (Ed.)
    • ISO 6872-dentistry-ceramic materials 2008, International Organisation of Standardisation, Genf. International Organisation of Standardisation (Ed.).
    • (2008) ISO 6872-dentistry-ceramic materials
  • 31
    • 84870659063 scopus 로고    scopus 로고
    • Beuth Verlag, Berlin, Deutsches Institut für Normung e.V. (Ed.)
    • DIN EN 843-Hochleistungskeramik 2008, Beuth Verlag, Berlin. Deutsches Institut für Normung e.V. (Ed.).
    • (2008) DIN EN 843-Hochleistungskeramik
  • 32
    • 34250636079 scopus 로고    scopus 로고
    • Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?
    • Anusavice K.J., Kakar K., Ferree N. Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?. Clin Oral Implants Res 2007, 18(Suppl. 3):218-231.
    • (2007) Clin Oral Implants Res , vol.18 , Issue.SUPPL. 3 , pp. 218-231
    • Anusavice, K.J.1    Kakar, K.2    Ferree, N.3
  • 33
    • 59149092803 scopus 로고    scopus 로고
    • Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach
    • Aboushelib M.N., Feilzer A.J., Kleverlaan C.J. Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach. Dent Mater 2009, 25:383-391.
    • (2009) Dent Mater , vol.25 , pp. 383-391
    • Aboushelib, M.N.1    Feilzer, A.J.2    Kleverlaan, C.J.3
  • 34
    • 37049008682 scopus 로고    scopus 로고
    • Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests
    • Hsueh C.H., Thompson G.A., Jadaan O.M., Wereszczak A.A., Becher P.F. Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests. Dent Mater 2008, 24:9-17.
    • (2008) Dent Mater , vol.24 , pp. 9-17
    • Hsueh, C.H.1    Thompson, G.A.2    Jadaan, O.M.3    Wereszczak, A.A.4    Becher, P.F.5
  • 36
    • 0842286709 scopus 로고    scopus 로고
    • Creep functions of dental ceramics measured in a beam-bending viscometer
    • DeHoff P.H., Anusavice K.J. Creep functions of dental ceramics measured in a beam-bending viscometer. Dent Mater 2004, 20:297-304.
    • (2004) Dent Mater , vol.20 , pp. 297-304
    • DeHoff, P.H.1    Anusavice, K.J.2
  • 38
    • 52049118769 scopus 로고    scopus 로고
    • Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling
    • Guess P.C., Kulis A., Witkowski S., Wolkewitz M., Zhang Y., Strub J.R. Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling. Dent Mater 2008, 24:1556-1567.
    • (2008) Dent Mater , vol.24 , pp. 1556-1567
    • Guess, P.C.1    Kulis, A.2    Witkowski, S.3    Wolkewitz, M.4    Zhang, Y.5    Strub, J.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.