메뉴 건너뛰기




Volumn 58, Issue 6, 2012, Pages 597-600

Evaluation of a ventricular assist device system: Stability in a proton beam therapy

Author keywords

HeartWare left ventricular assist device; left ventricular assist device; proton beam treatment; radiation; ventricular assist device

Indexed keywords

BASELINE VALUES; DOSE RATE; EXTERNAL COMPONENTS; HIGH ENERGY PROTON BEAMS; IMPLANTED DEVICE; PROTON BEAM THERAPY; PUMP PARAMETERS; RADIATION ONCOLOGISTS; SECONDARY NEUTRONS; SYSTEM CONTROLLERS; TREATMENT PLANS; VENTRICULAR ASSIST DEVICE;

EID: 84868666951     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e31826feeca     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 77950897411 scopus 로고    scopus 로고
    • HeartMate II Investigators: Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients
    • Rogers JG, Aaronson KD, Boyle AJ, et al: HeartMate II Investigators: Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol 55: 1826-1834, 2010.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1826-1834
    • Rogers, J.G.1    Aaronson, K.D.2    Boyle, A.J.3
  • 2
    • 78650951866 scopus 로고    scopus 로고
    • Third INTERMACS Annual Report: The evolution of destination therapy in the United States
    • Kirklin JK, Naftel DC, Kormos RL, et al: Third INTERMACS Annual Report: The evolution of destination therapy in the United States. J Heart Lung Transplant 30: 115-123, 2011.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 115-123
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 3
    • 67650093608 scopus 로고    scopus 로고
    • HeartMate II Investigators: Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani FD, Miller LW, Russell SD, et al: HeartMate II Investigators: Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54: 312-321, 2009.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 4
    • 0027976720 scopus 로고
    • Management of radiation oncology patients with implanted cardiac pacemakers: Report of AAPM Task Group1 No 34 American Association of Physicists in Medicine
    • Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB: Management of radiation oncology patients with implanted cardiac pacemakers: Report of AAPM Task Group No. 34. American Association of Physicists in Medicine. Med Phys 21: 85-90, 1994.
    • (1994) Med Phys , vol.21 , pp. 85-90
    • Marbach, J.R.1    Sontag, M.R.2    Van Dyk, J.3    Wolbarst, A.B.4
  • 5
    • 0031984219 scopus 로고    scopus 로고
    • Radiotherapy in patients with cardiac pacemakers
    • Last A: Radiotherapy in patients with cardiac pacemakers. Br J Radiol 71: 4-10, 1998.
    • (1998) Br J Radiol , vol.71 , pp. 4-10
    • Last, A.1
  • 6
    • 0037151345 scopus 로고    scopus 로고
    • J, Haug R, Bridier A, Dodinot B, Eschwege F: Influence of high-energy photon beam irradiation on pacemaker operation
    • Mouton
    • Mouton J, Haug R, Bridier A, Dodinot B, Eschwege F: Influence of high-energy photon beam irradiation on pacemaker operation. Phys Med Biol 47: 2879-2893, 2002.
    • (2002) Phys Med Biol , vol.47 , pp. 2879-2893
  • 7
    • 62649133296 scopus 로고    scopus 로고
    • Implanted cardiac defibrillator care in radiation oncology patient population
    • Gelblum DY, Amols H: Implanted cardiac defibrillator care in radiation oncology patient population. Int J Radiat Oncol Biol Phys 73: 1525-1531, 2009.
    • (2009) Int J Radiat Oncol Biol Phys , vol.73 , pp. 1525-1531
    • Gelblum, D.Y.1    Amols, H.2
  • 8
  • 10
    • 28044440085 scopus 로고    scopus 로고
    • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating
    • Nitz WR, Brinker G, Diehl D, Frese G: Specific absorption rate as a poor indicator of magnetic resonance-related implant heating. Invest Radiol 40: 773-776, 2005.
    • (2005) Invest Radiol , vol.40 , pp. 773-776
    • Nitz, W.R.1    Brinker, G.2    Diehl, D.3    Frese, G.4
  • 12
    • 84860734883 scopus 로고    scopus 로고
    • Evaluation of a ventricular assist device: Stability under x-rays and therapeutic beam attenuation
    • Gossman MS, Graham JD, Tamez D, Voskoboynikov N, Larose JA: Evaluation of a ventricular assist device: Stability under x-rays and therapeutic beam attenuation. ASAIO J 58: 212-216, 2012.
    • (2012) ASAIO J , vol.58 , pp. 212-216
    • Gossman, M.S.1    Graham, J.D.2    Tamez, D.3    Voskoboynikov, N.4    Larose, J.A.5
  • 13
    • 0032698686 scopus 로고    scopus 로고
    • Proton-beam radiotherapy for early-stage lung cancer
    • Bush DA, Slater JD, Bonnet R, et al: Proton-beam radiotherapy for early-stage lung cancer. Chest 116: 1313-1319, 1999.
    • (1999) Chest , vol.116 , pp. 1313-1319
    • Bush, D.A.1    Slater, J.D.2    Bonnet, R.3
  • 14
    • 84858337939 scopus 로고    scopus 로고
    • Results of proton beam therapy without concurrent chemotherapy for patients with unresectable stage III non-small cell lung cancer
    • Oshiro Y, Mizumoto M, Okumura T, et al: Results of proton beam therapy without concurrent chemotherapy for patients with unresectable stage III non-small cell lung cancer. J Thorac Oncol 7: 370-375, 2012.
    • (2012) J Thorac Oncol , vol.7 , pp. 370-375
    • Oshiro, Y.1    Mizumoto, M.2    Okumura, T.3
  • 15
    • 80053281931 scopus 로고    scopus 로고
    • Protons safely allow coverage of high-risk nodes for patients with regionally advanced non-small-cell lung cancer
    • Nichols RC, Huh SH, Hoppe BS, et al: Protons safely allow coverage of high-risk nodes for patients with regionally advanced non-small-cell lung cancer. Technol Cancer Res Treat 10: 317-322, 2011.
    • (2011) Technol Cancer Res Treat , vol.10 , pp. 317-322
    • Nichols, R.C.1    Huh, S.H.2    Hoppe, B.S.3
  • 16
    • 77954959655 scopus 로고    scopus 로고
    • Design concepts and principle of operation of the HeartWare ventricular assist system
    • Larose JA, Tamez D, Ashenuga M, Reyes C: Design concepts and principle of operation of the HeartWare ventricular assist system. ASAIO J 56: 285-289, 2010.
    • (2010) ASAIO J , vol.56 , pp. 285-289
    • Larose, J.A.1    Tamez, D.2    Ashenuga, M.3    Reyes, C.4
  • 17
    • 54949127210 scopus 로고    scopus 로고
    • Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking
    • Farr JB, Mascia AE, Hsi WC, et al: Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking. Med Phys 35: 4945-4954, 2008.
    • (2008) Med Phys , vol.35 , pp. 4945-4954
    • Farr, J.B.1    Mascia, A.E.2    Hsi, W.C.3
  • 20
    • 84867282038 scopus 로고    scopus 로고
    • Vagus nerve stimulator stability and interference on radiation oncology x-ray beams
    • Gossman MS, Ketkar A, Liu AK, Olin B: Vagus nerve stimulator stability and interference on radiation oncology x-ray beams. Phys Med Biol 57: N365, 2012.
    • (2012) Phys Med Biol , vol.57
    • Gossman, M.S.1    Ketkar, A.2    Liu, A.K.3    Olin, B.4
  • 21
    • 77953532941 scopus 로고    scopus 로고
    • Influence of beam efficiency through the patient-specific collimator on secondary neutron dose equivalent in double scattering and uniform scanning modes of proton therapy
    • Hecksel D, Anferov V, Fitzek M, Shahnazi K: Influence of beam efficiency through the patient-specific collimator on secondary neutron dose equivalent in double scattering and uniform scanning modes of proton therapy. Med Phys 37(6): 2910-2917, 2010.
    • (2010) Med Phys 37 , vol.6 , pp. 2910-2917
    • Hecksel, D.1    Anferov, V.2    Fitzek, M.3    Shahnazi, K.4
  • 22
    • 40649121085 scopus 로고    scopus 로고
    • Scattered neutron dose equivalent from an active scanning proton beam delivery system
    • Hecksel D, Sandison GA, Farr JB, Edwards AC: Scattered neutron dose equivalent from an active scanning proton beam delivery system. Australas Phys Eng Sci Med 30(4): 326-330, 2007.
    • (2007) Australas Phys Eng Sci Med , vol.30 , Issue.4 , pp. 326-330
    • Hecksel, D.1    Sandison, G.A.2    Farr, J.B.3    Edwards, A.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.