Damaging effect of therapeutic radiation on programmable pacemakers
-
R. Adamec, J.M. Haefliger, J.P. Killisch, J. Niederer, and P. Jaquet Damaging effect of therapeutic radiation on programmable pacemakers Pacing Clin Electrophysiol 5 1982 146 150
-
(1982)
Pacing Clin Electrophysiol
, vol.5
, pp. 146-150
-
-
Adamec, R.1
Haefliger, J.M.2
Killisch, J.P.3
Niederer, J.4
Jaquet, P.5
-
3
-
-
0037089659
-
Implantable cardiac defibrillators may be damaged by radiation therapy
-
S. Hoecht, P. Rosenthal, and D. Sancar Implantable cardiac defibrillators may be damaged by radiation therapy J Clin Oncol 20 2002 2212 2213
-
(2002)
J Clin Oncol
, vol.20
, pp. 2212-2213
-
-
Hoecht, S.1
Rosenthal, P.2
Sancar, D.3
-
4
-
-
0031984219
-
Radiotherapy in patients with cardiac pacemakers
-
A. Last Radiotherapy in patients with cardiac pacemakers Br J Radiol. 71 1998 4 10
-
(1998)
Br J Radiol.
, vol.71
, pp. 4-10
-
-
Last, A.1
-
5
-
-
0027976720
-
Management of radiation oncology patients with implanted cardiac pacemakers: Report of AAPM Task Group No. 34. American Association of Physicists in Medicine
-
J.R. Marbach, M.R. Sontag, J. Van Dyk, and A.B. Wolbarst Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM Task Group No. 34. American Association of Physicists in Medicine Med Phys 21 1994 85 90
-
(1994)
Med Phys
, vol.21
, pp. 85-90
-
-
Marbach, J.R.1
Sontag, M.R.2
Van Dyk, J.3
Wolbarst, A.B.4
-
6
-
-
33544473644
-
-
Minneapolis: Medtronic USA Inc.
-
Medtronic USA Inc. Technical services. Radiation and pacemakers. 1-2; 2002. Minneapolis: Medtronic USA Inc.
-
(2002)
Radiation and Pacemakers
, pp. 1-2
-
-
-
7
-
-
0037151345
-
Influence of high-energy photon beam irradiation on pacemaker operation
-
J. Mouton, R. Haug, A. Bridier, B. Dodinot, and F. Eschwege Influence of high-energy photon beam irradiation on pacemaker operation Phys Med Biol 47 2002 2879 2893
-
(2002)
Phys Med Biol
, vol.47
, pp. 2879-2893
-
-
Mouton, J.1
Haug, R.2
Bridier, A.3
Dodinot, B.4
Eschwege, F.5
-
8
-
-
0027322461
-
Pacemaker function during irradiation: In vivo and in vitro effect
-
S.L. Ngu, P. O'Meley, N. Johnson, and C. Collins Pacemaker function during irradiation: in vivo and in vitro effect Australas Radiol 37 1993 105 107
-
(1993)
Australas Radiol
, vol.37
, pp. 105-107
-
-
Ngu, S.L.1
O'Meley, P.2
Johnson, N.3
Collins, C.4
-
9
-
-
0026320376
-
Radiation-induced effects in multiprogrammable pacemakers and implantable defibrillators
-
F. Rodriguez, A. Filimonov, A. Henning, C. Coughlin, and M. Greenberg Radiation-induced effects in multiprogrammable pacemakers and implantable defibrillators Pacing Clin Electrophysiol 14 1991 2143 2153
-
(1991)
Pacing Clin Electrophysiol
, vol.14
, pp. 2143-2153
-
-
Rodriguez, F.1
Filimonov, A.2
Henning, A.3
Coughlin, C.4
Greenberg, M.5
-
10
-
-
0025241758
-
The influence of electromagnetic interference and ionizing radiation on cardiac pacemakers
-
J. Salmi, H.J. Eskola, M.A. Pitkanen, and J.A. Malmivuo The influence of electromagnetic interference and ionizing radiation on cardiac pacemakers Strahlenther Onkol 166 1990 153 156
-
(1990)
Strahlenther Onkol
, vol.166
, pp. 153-156
-
-
Salmi, J.1
Eskola, H.J.2
Pitkanen, M.A.3
Malmivuo, J.A.4
-
11
-
-
0029258707
-
Implanted devices and electromagnetic interference: Case presentations and review
-
J.S. Snow, D. Kalenderian, and J.A. Colasacco Implanted devices and electromagnetic interference: case presentations and review J Invasive Cardiol 7 1995 25 32
-
(1995)
J Invasive Cardiol
, vol.7
, pp. 25-32
-
-
Snow, J.S.1
Kalenderian, D.2
Colasacco, J.A.3
-
12
-
-
2942524163
-
Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy
-
A.N. Solan, M.J. Solan, G. Bednarz, and M.B. Goodkin Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy Int J Radiat Oncol Biol Phys 59 2004 897 904
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 897-904
-
-
Solan, A.N.1
Solan, M.J.2
Bednarz, G.3
Goodkin, M.B.4
-
14
-
-
0033674178
-
The cardiac pacemaker patient - Might the pacer be directly irradiated?
-
A. Tsekos, F. Momm, M. Brunner, and R. Guttenberger The cardiac pacemaker patient - might the pacer be directly irradiated? Acta Oncol 39 2000 881 883
-
(2000)
Acta Oncol
, vol.39
, pp. 881-883
-
-
Tsekos, A.1
Momm, F.2
Brunner, M.3
Guttenberger, R.4
-
15
-
-
0021959711
-
The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators
-
J.L. Venselaar The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators Radiother Oncol 3 1985 81 87
-
(1985)
Radiother Oncol
, vol.3
, pp. 81-87
-
-
Venselaar, J.L.1
|