Vagus nerve stimulator stability and interference on radiation oncology x-ray beams

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBED DOSE; DEVICE MODELS; DOSE CALCULATION; DOSE EFFECTS; HIGH ENERGY; INCIDENT RADIATION; NEUTRON EFFECTS; OUTPUT SIGNAL; PULSE GENERATION; RADIATION INTERFERENCE; RADIATION MEASUREMENTS; RADIATION ONCOLOGY; TREATMENT PLANNING SYSTEMS; VAGUS NERVE; X RAY BEAM; X RAY RADIATION;

EID: 84867282038     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/20/N365     Document Type: Article
Times cited : (9)

References (15)
  • 1
    • 0037833706 scopus 로고    scopus 로고
    • Calibration of CT hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: The use of the extended CT-scale
    • DOI 10.1088/0031-9155/48/11/308, PII S0031915503587048
    • Coolens C and Childs P J 2003 Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale Phys. Med. Biol. 48 1591-603 (Pubitemid 36713338)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.11 , pp. 1591-1603
    • Coolens, C.1    Childs, P.J.2
  • 2
    • 84867269857 scopus 로고    scopus 로고
    • Epilepsy Foundation of America
    • Epilepsy Foundation of America 2011a Epilepsy fact sheet Accessed on July 25, 2011 from http://www.epilepsyfoundation.org/about/factsfigures.cfm
    • (2011) Epilepsy Fact Sheet
  • 3
    • 84867266761 scopus 로고    scopus 로고
    • Epilepsy Foundation of America
    • Epilepsy Foundation of America 2011b Seizures and syndromes Accessed on July 25, 2011 from http://www.epilepsyfoundation.org/about/types
    • (2011) Seizures and Syndromes
  • 4
    • 84867242770 scopus 로고    scopus 로고
    • Radiation oncology dose gradients induced by heart rhythm devices
    • Gossman M S 2011a Radiation oncology dose gradients induced by heart rhythm devices Imag. Tech. News 51 16-8
    • (2011) Imag. Tech. News , vol.51 , pp. 16-18
    • Gossman, M.S.1
  • 6
    • 77954298418 scopus 로고    scopus 로고
    • Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillators
    • 1526-9914
    • Gossman M S, Graves-Calhoun A R and Wilkinson J D 2010 Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillators J. Appl. Clin. Med. Phys. 11 1-13
    • (2010) J. Appl. Clin. Med. Phys. , vol.11 , pp. 1-13
    • Gossman, M.S.1    Graves-Calhoun, A.R.2    Wilkinson, J.D.3
  • 7
    • 77749246162 scopus 로고    scopus 로고
    • Dosimetric effects near implanted vascular access ports: An examination of external photon beam dose calculations
    • 10.1120/jacmp.v10i3.2886 1526-9914
    • Gossman M S et al 2009 Dosimetric effects near implanted vascular access ports: an examination of external photon beam dose calculations J. Appl. Clin. Med. Phys. 10 3-15
    • (2009) J. Appl. Clin. Med. Phys. , vol.10 , Issue.3 , pp. 3-15
    • Gossman, M.S.1
  • 8
    • 0026316894 scopus 로고
    • Primary mandibular reconstruction: Analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates
    • Gullane P J 1991 Primary mandibular reconstruction: analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates Laryngoscope 101 1-24
    • (1991) Laryngoscope , vol.101 , pp. 1-24
    • Gullane, P.J.1
  • 9
    • 77957369872 scopus 로고    scopus 로고
    • X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers
    • 10.1111/j.1540-8159.2010.02846.x 0147-8389
    • Hirose M et al 2010 X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers Pacing Clin. Electrophysiol. 33 1174-81
    • (2010) Pacing Clin. Electrophysiol. , vol.33 , Issue.10 , pp. 1174-1181
    • Hirose, M.1
  • 11
    • 0034598762 scopus 로고    scopus 로고
    • Early identification of refractory epilepsy
    • DOI 10.1056/NEJM200002033420503
    • Kwan P and Brodie M J 2000 Early identification of refractory epilepsy New Engl. J. Med. 342 314-9 (Pubitemid 30075244)
    • (2000) New England Journal of Medicine , vol.342 , Issue.5 , pp. 314-319
    • Kwan, P.1    Brodie, M.J.2
  • 12
    • 0034919320 scopus 로고    scopus 로고
    • Monotherapy trials: Endpoints
    • DOI 10.1016/S0920-1211(01)00232-7, PII S0920121101002327
    • Mattson R H 2001 Monotherapy trials: endpoints Epilepsy Res. 45 109-17 (Pubitemid 32673603)
    • (2001) Epilepsy Research , vol.45 , Issue.1-3 , pp. 109-117
    • Mattson, R.H.1
  • 14
    • 2942523218 scopus 로고    scopus 로고
    • The utilization of a 3-dimensional noncoplanar treatment plan to avoid pacemaker complications
    • DOI 10.1016/j.meddos.2004.03.013, PII S0958394704000433
    • Riley B, Garcia J and Guerrero T 2004 The utilization of a 3-dimensional non-coplanar treatment plan to avoid pacemaker complications Med. Dosim. 29 92-6 (Pubitemid 38748873)
    • (2004) Medical Dosimetry , vol.29 , Issue.2 , pp. 92-96
    • Riley, B.1    Garcia, J.2    Guerrero, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.