메뉴 건너뛰기




Volumn 58, Issue 3, 2012, Pages 212-216

Evaluation of a ventricular assist device: Stability under X-rays and therapeutic beam attenuation

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER MODELING; COMPUTERIZED TOMOGRAPHY SCAN; DATA ACQUISITION SYSTEM; HEART FAILURE; HIGH INTENSITY; OPERATIONAL STABILITY; PRE-TREATMENT; PUMP OPERATION; PUMP PARAMETERS; QUALITY OF LIFE; RADIATION MEASUREMENTS; RADIATION ONCOLOGY; SCATTERING PROCESS; THERAPEUTIC BEAMS; TITANIUM COMPONENTS; TREATMENT PLANNING; VENTRICULAR ASSIST DEVICE;

EID: 84860734883     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3182468318     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 77950897411 scopus 로고    scopus 로고
    • Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients
    • Rogers JG, Aaronson KD, Boyle AJ, et al: Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol 55: 1826-1834, 2010.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1826-1834
    • Rogers, J.G.1    Aaronson, K.D.2    Boyle, A.J.3
  • 2
    • 78650951866 scopus 로고    scopus 로고
    • Third INTERMACS annual report: The evolution of destination therapy in the United States
    • Kirklin J, Naftel D, Kormos R, et al: Third INTERMACS Annual Report: The evolution of destination therapy in the United States. J Heart Lung Transplant 30: 115-123, 2011.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 115-123
    • Kirklin, J.1    Naftel, D.2    Kormos, R.3
  • 3
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani FD, Miller LW, Russell SD, et al: Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54: 312-321, 2009.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 4
    • 29344435313 scopus 로고    scopus 로고
    • Cancer-radiotherapy equipment as a cause of soft errors in electronic equipment
    • Wilkinson JD, Bounds C, Brown T, et al: Cancer-radiotherapy equipment as a cause of soft errors in electronic equipment. IEEE Trans Dev Mat Rel 5: 449-451, 2005.
    • (2005) IEEE Trans Dev Mat Rel , vol.5 , pp. 449-451
    • Wilkinson, J.D.1    Bounds, C.2    Brown, T.3
  • 5
    • 77957369872 scopus 로고    scopus 로고
    • X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers
    • Hirose M, Tachikawa K, Ozaki M, et al: X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers. Pacing Clin Electrophys 33: 1174-1181, 2010.
    • (2010) Pacing Clin Electrophys , vol.33 , pp. 1174-1181
    • Hirose, M.1    Tachikawa, K.2    Ozaki, M.3
  • 7
    • 77954298418 scopus 로고    scopus 로고
    • Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillators
    • Gossman MS, Graves-Calhoun AR, Wilkinson JD: Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillators. J Appl Clin Med Phys 11: 3115, 2010.
    • (2010) J Appl Clin Med Phys , vol.11 , pp. 3115
    • Gossman, M.S.1    Graves-Calhoun, A.R.2    Wilkinson, J.D.3
  • 8
    • 77749246162 scopus 로고    scopus 로고
    • Dosimetric effects near implanted vascular access ports: An examination of external photon beam calculation
    • Gossman MS, Seuntjens JP, Serban MM, et al: Dosimetric effects near implanted vascular access ports: An examination of external photon beam calculation. J Appl Clin Med Phys 10: 2886, 2009.
    • (2009) J Appl Clin Med Phys , vol.10 , pp. 2886
    • Gossman, M.S.1    Seuntjens, J.P.2    Serban, M.M.3
  • 9
    • 77954959655 scopus 로고    scopus 로고
    • Design concepts and principle of operation of the HeartWare ventricular assist system
    • Larose JA, Tamez D, Ashenuga M, Reyes C: Design concepts and principle of operation of the HeartWare ventricular assist system. ASAIO J 56: 285-289, 2010.
    • (2010) ASAIO J , vol.56 , pp. 285-289
    • Larose, J.A.1    Tamez, D.2    Ashenuga, M.3    Reyes, C.4
  • 10
    • 0037833706 scopus 로고    scopus 로고
    • Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: The use of the extended CT-scale
    • Coolens C, Childs PJ: Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: The use of the extended CT-scale. Phys Med Biol 48: 1591-1603, 2003.
    • (2003) Phys Med Biol , vol.48 , pp. 1591-1603
    • Coolens, C.1    Childs, P.J.2
  • 11
    • 70049087157 scopus 로고    scopus 로고
    • Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device
    • Lasher DE, Wojcicka JB, Malcom R, Shears LL: Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device. J Appl Clin Med Phys 9: 2851, 2008.
    • (2008) J Appl Clin Med Phys , vol.9 , pp. 2851
    • Lasher, D.E.1    Wojcicka, J.B.2    Malcom, R.3    Shears, L.L.4
  • 12
    • 77749320940 scopus 로고    scopus 로고
    • Effect of radiation therapy on the latest generation of pacemakers and implantable cardioverter defibrillators: A systematic review
    • Hudson F, Coulshed D, D'Souza E, Baker C: Effect of radiation therapy on the latest generation of pacemakers and implantable cardioverter defibrillators: A systematic review. J Med Imaging Radiat Oncol 54: 53-61, 2010.
    • (2010) J Med Imaging Radiat Oncol , vol.54 , pp. 53-61
    • Hudson, F.1    Coulshed, D.2    D'Souza, E.3    Baker, C.4
  • 13
    • 33749409973 scopus 로고    scopus 로고
    • In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT
    • Reft CS, Runkel-Muller R, Myrianthopoulos L: In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT. Med Phys 33: 3734-3742, 2006.
    • (2006) Med Phys , vol.33 , pp. 3734-3742
    • Reft, C.S.1    Runkel-Muller, R.2    Myrianthopoulos, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.