메뉴 건너뛰기




Volumn 39, Issue 10, 2012, Pages 6431-6442

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Author keywords

CBCT; IGRT; liver motion; marker tracking; SBRT

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DATA MINING; LOCATION; PATIENT MONITORING; RADIOTHERAPY; X RAYS;

EID: 84867314318     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4754658     Document Type: Article
Times cited : (101)

References (33)
  • 3
    • 68649087156 scopus 로고    scopus 로고
    • Inter- and intrafraction variability in liver position in non-breath-hold stereotactic body radiotherapy
    • 10.1016/j.ijrob2009.03.058
    • R. B. Case, J. J. Sonke, D. J. Moseley, J. Kim, K. K. Brock, and L. A. Dawson, Inter- and intrafraction variability in liver position in non-breath-hold stereotactic body radiotherapy., Int. J. Radiat. Oncol., Biol., Phys. 75 (1), 302-308 (2009). 10.1016/j.ijrobp.2009.03.058
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.75 , Issue.1 , pp. 302-308
    • Case, R.B.1    Sonke, J.J.2    Moseley, D.J.3    Kim, J.4    Brock, K.K.5    Dawson, L.A.6
  • 4
    • 0037403214 scopus 로고    scopus 로고
    • Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system
    • 10.1016/S0360-3016(03)00082-8
    • K. Kitamura, H. Shirato, Y. Seppenwoolde, T. Shimizu, Y. Kodama, H. Endo, R. Onimaru, M. Oda, K. Fujita, S. Shimizu, and K. Miyasaka, Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system., Int. J. Radiat. Oncol., Biol., Phys. 56 (1), 221-228 (2003). 10.1016/S0360-3016(03)00082-8
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.56 , Issue.1 , pp. 221-228
    • Kitamura, K.1    Shirato, H.2    Seppenwoolde, Y.3    Shimizu, T.4    Kodama, Y.5    Endo, H.6    Onimaru, R.7    Oda, M.8    Fujita, K.9    Shimizu, S.10    Miyasaka, K.11
  • 5
    • 69549124730 scopus 로고    scopus 로고
    • Synchronous monitoring of externalinternal respiratory motion: Validity of respiration-gated radiotherapy for liver tumors
    • 10.1007/s11604-009-0332-5
    • T. Nishioka, S. Nishioka, M. Kawahara, S. Tanaka, H. Shirato, K. Nishi, and T. Hiromura, Synchronous monitoring of externalinternal respiratory motion: validity of respiration-gated radiotherapy for liver tumors., Jpn. J. Radiol. 27 (7), 285-289 (2009). 10.1007/s11604-009-0332-5
    • (2009) Jpn. J. Radiol. , vol.27 , Issue.7 , pp. 285-289
    • Nishioka, T.1    Nishioka, S.2    Kawahara, M.3    Tanaka, S.4    Shirato, H.5    Nishi, K.6    Hiromura, T.7
  • 8
    • 33748865018 scopus 로고    scopus 로고
    • Individualized image guided iso-NTCP based liver cancer SBRT
    • 10.1080/02841860600936369
    • L. A. Dawson, C. Eccles, and T. Craig, Individualized image guided iso-NTCP based liver cancer SBRT., Acta Oncol. 45 (7), 856-864 (2006). 10.1080/02841860600936369
    • (2006) Acta Oncol. , vol.45 , Issue.7 , pp. 856-864
    • Dawson, L.A.1    Eccles, C.2    Craig, T.3
  • 9
    • 68649119703 scopus 로고    scopus 로고
    • Variability in the amplitude of liver motion in patients undergoing cone-beam CT image-guided free breathing stereotactic body radiotherapy
    • R. Case, D. Moseley, J. P. Bissonnette, J. Kim, and L. Dawson, Variability in the amplitude of liver motion in patients undergoing cone-beam CT image-guided free breathing stereotactic body radiotherapy., Radiother. Oncol. 84, S38-S38 (2007).
    • (2007) Radiother. Oncol. , vol.84
    • Case, R.1    Moseley, D.2    Bissonnette, J.P.3    Kim, J.4    Dawson, L.5
  • 11
    • 77955504323 scopus 로고    scopus 로고
    • Potentials and limitations of guiding liver stereotactic body radiation therapy set-up on liver-implanted fiducial markers
    • 10.1016/j.ijrob2009.10.040
    • W. Wunderink, A. Mendez Romero, Y. Seppenwoolde, H. de Boer, P. Levendag, and B. Heijmen, Potentials and limitations of guiding liver stereotactic body radiation therapy set-up on liver-implanted fiducial markers., Int. J. Radiat. Oncol., Biol., Phys. 77 (5), 1573-1583 (2010). 10.1016/j.ijrobp.2009.10.040
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.77 , Issue.5 , pp. 1573-1583
    • Wunderink, W.1    Mendez Romero, A.2    Seppenwoolde, Y.3    De Boer, H.4    Levendag, P.5    Heijmen, B.6
  • 12
    • 80052072847 scopus 로고    scopus 로고
    • Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance
    • 10.1088/0031-9155/56/17/001
    • Y. Seppenwoolde, W. Wunderink, W. R. Wunderink-van Veen, P. Storchi, A. Mendez Romero, and B. J. M. Heijmen, Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance., Phys. Med. Biol. 56 (17), 5445-5468 (2011). 10.1088/0031-9155/56/17/001
    • (2011) Phys. Med. Biol. , vol.56 , Issue.17 , pp. 5445-5468
    • Seppenwoolde, Y.1    Wunderink, W.2    Wunderink-Van Veen, W.R.3    Storchi, P.4    Mendez Romero, A.5    Heijmen, B.J.M.6
  • 13
    • 46549087179 scopus 로고    scopus 로고
    • Improved local control associated with dose-escalated stereotactic body radiation therapy (SBRT) indicates dose-response relationship
    • 10.1016/j.ijrob2007.07.278
    • R. McCammon, T. Schefter, R. Zaemisch, D. Gravdahl, and B. Kavanagh, Improved local control associated with dose-escalated stereotactic body radiation therapy (SBRT) indicates dose-response relationship., Int. J. Radiat. Oncol., Biol., Phys. 69 (3), S152-S153 (2007). 10.1016/j.ijrobp.2007.07.278
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.69 , Issue.3
    • McCammon, R.1    Schefter, T.2    Zaemisch, R.3    Gravdahl, D.4    Kavanagh, B.5
  • 15
    • 79957542295 scopus 로고    scopus 로고
    • Interfraction liver shape variability and impact on GTV position during liver stereotactic radiotherapy using abdominal compression
    • 10.1016/j.ijrob2010.08.003
    • C. L. Eccles, L. A. Dawson, J. L. Moseley, and K. K. Brock, Interfraction liver shape variability and impact on GTV position during liver stereotactic radiotherapy using abdominal compression., Int. J. Radiat. Oncol., Biol., Phys. 80 (3), 938-946 (2011). 10.1016/j.ijrobp.2010.08.003
    • (2011) Int. J. Radiat. Oncol., Biol., Phys. , vol.80 , Issue.3 , pp. 938-946
    • Eccles, C.L.1    Dawson, L.A.2    Moseley, J.L.3    Brock, K.K.4
  • 16
    • 40949110503 scopus 로고    scopus 로고
    • Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver
    • 10.1016/j.ijrob2007.12.023
    • J. H. Heinzerling, J. F. Anderson, L. Papiez, T. Boike, S. Chien, G. Zhang, R. Abdulrahman, and R. Timmerman, Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver., Int. J. Radiat. Oncol., Biol., Phys. 70 (5), 1571-1578 (2008). 10.1016/j.ijrobp.2007.12.023
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.70 , Issue.5 , pp. 1571-1578
    • Heinzerling, J.H.1    Anderson, J.F.2    Papiez, L.3    Boike, T.4    Chien, S.5    Zhang, G.6    Abdulrahman, R.7    Timmerman, R.8
  • 17
    • 44349097392 scopus 로고    scopus 로고
    • Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver
    • 10.1016/j.ijrob2008.03.010
    • W. Wunderink, A. Mendez Romero, W. de Kruijf, H. de Boer, P. Levendag, and B. Heijmen, Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver., Int. J. Radiat. Oncol., Biol., Phys. 71 (3), 907-915 (2008). 10.1016/j.ijrobp.2008.03.010
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71 , Issue.3 , pp. 907-915
    • Wunderink, W.1    Mendez Romero, A.2    De Kruijf, W.3    De Boer, H.4    Levendag, P.5    Heijmen, B.6
  • 19
    • 0034332698 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame
    • 10.1016/S0167-8140(00)00226-7
    • J. Wulf, U. Hadinger, U. Oppitz, B. Olshausen, and M. Flentje, Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame., J. Clin. Oncol. 57 (2), 225-236 (2000). 10.1016/S0167-8140(00)00226-7
    • (2000) J. Clin. Oncol. , vol.57 , Issue.2 , pp. 225-236
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Olshausen, B.4    Flentje, M.5
  • 20
    • 0037296427 scopus 로고    scopus 로고
    • Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver
    • 10.1016/S0167-8140(02)00372-9
    • J. Wulf, U. Hadinger, U. Oppitz, W. Thiele, and M. Flentje, Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver., J. Clin. Oncol. 66 (2), 141-150 (2003). 10.1016/S0167-8140(02)00372-9
    • (2003) J. Clin. Oncol. , vol.66 , Issue.2 , pp. 141-150
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Thiele, W.4    Flentje, M.5
  • 21
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • 10.1016/S0167-8140(02)00017-8
    • K. Kitamura, H. Shirato, S. Shimizu, N. Shinohara, T. Harabayashi, T. Shimizu, Y. Kodama, H. Endo, R. Onimaru, S. Nishioka, H. Aoyama, K. Tsuchiya, and K. Miyasaka, Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)., J. Clin. Oncol. 62 (3), 275-281 (2002). 10.1016/S0167-8140(02)00017-8
    • (2002) J. Clin. Oncol. , vol.62 , Issue.3 , pp. 275-281
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3    Shinohara, N.4    Harabayashi, T.5    Shimizu, T.6    Kodama, Y.7    Endo, H.8    Onimaru, R.9    Nishioka, S.10    Aoyama, H.11    Tsuchiya, K.12    Miyasaka, K.13
  • 23
    • 4444313627 scopus 로고    scopus 로고
    • Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy
    • 10.1016/j.ijrob2004.04.028
    • H. Shirato, M. Oita, K. Fujita, Y. Watanabe, and K. Miyasaka, Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy., Int. J. Radiat. Oncol., Biol., Phys. 60 (1), 335-341 (2004). 10.1016/j.ijrobp.2004.04.028
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.60 , Issue.1 , pp. 335-341
    • Shirato, H.1    Oita, M.2    Fujita, K.3    Watanabe, Y.4    Miyasaka, K.5
  • 26
    • 67049086549 scopus 로고    scopus 로고
    • First demonstration of combined kVMV image-guided real-time dynamic multileaf-collimator target tracking
    • 10.1016/j.ijrob2009.02.012
    • B. Cho, P. R. Poulsen, A. Sloutsky, A. Sawant, and P. J. Keall, First demonstration of combined kVMV image-guided real-time dynamic multileaf-collimator target tracking., Int. J. Radiat. Oncol., Biol., Phys. 74 (3), 859-867 (2009). 10.1016/j.ijrobp.2009.02.012
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , Issue.3 , pp. 859-867
    • Cho, B.1    Poulsen, P.R.2    Sloutsky, A.3    Sawant, A.4    Keall, P.J.5
  • 27
    • 58149214088 scopus 로고    scopus 로고
    • Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging
    • 10.1088/0031-9155/53/24/013
    • W. Liu, R. D. Wiersma, W. Mao, G. Luxton, and L. Xing, Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging., Phys. Med. Biol. 53 (24), 7197-7213 (2008). 10.1088/0031-9155/53/24/ 013
    • (2008) Phys. Med. Biol. , vol.53 , Issue.24 , pp. 7197-7213
    • Liu, W.1    Wiersma, R.D.2    Mao, W.3    Luxton, G.4    Xing, L.5
  • 28
    • 41449112602 scopus 로고    scopus 로고
    • Combined kV and MV imaging for real-time tracking of implanted fiducial markers
    • 10.1118/1.2842072
    • R. D. Wiersma, W. Mao, and L. Xing, Combined kV and MV imaging for real-time tracking of implanted fiducial markers., Med. Phys. 35 (4), 1191-1198 (2008). 10.1118/1.2842072
    • (2008) Med. Phys. , vol.35 , Issue.4 , pp. 1191-1198
    • Wiersma, R.D.1    Mao, W.2    Xing, L.3
  • 29
    • 79551661276 scopus 로고    scopus 로고
    • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT
    • 10.1118/1.3544369
    • J. C. Park, S. H. Park, J. H. Kim, S. M. Yoon, S. S. Kim, J. S. Kim, Z. Liu, W. T. Watkins, and W. Y. Song, Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT., Med. Phys. 38 (2), 1028-1036 (2011). 10.1118/1.3544369
    • (2011) Med. Phys. , vol.38 , Issue.2 , pp. 1028-1036
    • Park, J.C.1    Park, S.H.2    Kim, J.H.3    Yoon, S.M.4    Kim, S.S.5    Kim, J.S.6    Liu, Z.7    Watkins, W.T.8    Song, W.Y.9
  • 30
    • 78650072644 scopus 로고    scopus 로고
    • Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration
    • 10.1088/0031-9155/55/24/004
    • N. Becker, W. L. Smith, S. Quirk, and I. Kay, Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration., Phys. Med. Biol. 55 (24), 7439-7452 (2010). 10.1088/0031-9155/55/24/004
    • (2010) Phys. Med. Biol. , vol.55 , Issue.24 , pp. 7439-7452
    • Becker, N.1    Smith, W.L.2    Quirk, S.3    Kay, I.4
  • 31
    • 39049157181 scopus 로고    scopus 로고
    • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images
    • 10.1088/0031-9155/53/4/018
    • T. E. Marchant, A. M. Amer, and C. J. Moore, Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images., Phys. Med. Biol. 53 (4), 1087-1098 (2008). 10.1088/0031-9155/53/4/018
    • (2008) Phys. Med. Biol. , vol.53 , Issue.4 , pp. 1087-1098
    • Marchant, T.E.1    Amer, A.M.2    Moore, C.J.3
  • 32
    • 56349142559 scopus 로고    scopus 로고
    • A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy
    • 10.1016/j.ijrob2008.07.037
    • P. R. Poulsen, B. Cho, and P. J. Keall, A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy., Int. J. Radiat. Oncol., Biol., Phys. 72 (5), 1587-1596 (2008). 10.1016/j.ijrobp.2008.07.037
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , Issue.5 , pp. 1587-1596
    • Poulsen, P.R.1    Cho, B.2    Keall, P.J.3
  • 33
    • 79961038676 scopus 로고    scopus 로고
    • Potential underestimation of the internal target volume (ITV) from free-breathing CBCT
    • 10.1118/1.3613153
    • I. Vergalasova, J. Maurer, and F. F. Yin, Potential underestimation of the internal target volume (ITV) from free-breathing CBCT., Med. Phys. 38 (8), 4689-4699 (2011). 10.1118/1.3613153
    • (2011) Med. Phys. , vol.38 , Issue.8 , pp. 4689-4699
    • Vergalasova, I.1    Maurer, J.2    Yin, F.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.