메뉴 건너뛰기




Volumn 55, Issue 24, 2010, Pages 7439-7452

Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration

Author keywords

[No Author keywords available]

Indexed keywords

BREATHING PATTERNS; CONEBEAM CT; DATA SETS; FIDUCIAL MARKER; GOLD SEEDS; INTERNAL MOTION; LUNG CANCER; LUNG TUMOR; MAXIMUM ERROR; MOTION INFORMATION; PATIENT SETUP; PHANTOM EXPERIMENT; PHANTOM STUDIES; PROJECTION DATA; PROJECTION IMAGE; RESPIRATORY CYCLE; RESPIRATORY PATTERN; RMS ERRORS; ROOT-MEAN-SQUARE ERRORS; STEREOTACTIC BODY RADIOTHERAPY; SUBMILLIMETERS; TRAJECTORY RECONSTRUCTION; TREATMENT UNITS;

EID: 78650072644     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/24/004     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 0019471638 scopus 로고
    • A three-film technique for reconstruction of radioactive seed implants
    • Amols H I and Rosen I I 1981 A three-film technique for reconstruction of radioactive seed implants Med. Phys. 8 210-4
    • (1981) Med. Phys. , vol.8 , pp. 210-214
    • Amols, H.I.1    Rosen, I.I.2
  • 4
    • 34347222574 scopus 로고    scopus 로고
    • Treatment of early non-small cell lung cancer, stage IA, by image-guided robotic stereotactic radioablation - CyberKnife
    • Brown W T et al 2007 Treatment of early non-small cell lung cancer, stage IA, by image-guided robotic stereotactic radioablation - CyberKnife Cancer J. 13 87-94
    • (2007) Cancer J. , vol.13 , pp. 87-94
    • Brown, W.T.1
  • 5
    • 67049086549 scopus 로고    scopus 로고
    • First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking
    • Cho B, Poulsen P R, Sloutsky A, Sawant A and Keall P J 2009 First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking Int. J. Radiat. Oncol. Biol. Phys. 74 859-67
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.74 , pp. 859-867
    • Cho, B.1    Poulsen, P.R.2    Sloutsky, A.3    Sawant, A.4    Keall, P.J.5
  • 6
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall P J et al 2006 The management of respiratory motion in radiation oncology report of AAPM Task Group 76 Med. Phys. 33 3874-900
    • (2006) Med. Phys. , vol.33 , pp. 3874-3900
    • Keall, P.J.1
  • 8
    • 58149214088 scopus 로고    scopus 로고
    • Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging
    • Liu W, Wiersma R D, Mao W, Luxton G and Xing L 2008 Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging Phys. Med. Biol. 53 7197-213
    • (2008) Phys. Med. Biol. , vol.53 , pp. 7197-7213
    • Liu, W.1    Wiersma, R.D.2    Mao, W.3    Luxton, G.4    Xing, L.5
  • 9
    • 39049157181 scopus 로고    scopus 로고
    • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images
    • Marchant T E, Amer A M and Moore C J 2008 Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images Phys. Med. Biol. 53 1087-98
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1087-1098
    • Marchant, T.E.1    Amer, A.M.2    Moore, C.J.3
  • 10
    • 36148998365 scopus 로고    scopus 로고
    • Quantification of motion of different thoracic locations using four-dimensional computed tomography: Implications for radiotherapy planning
    • Maxim P G, Loo B W, Shirazi H, Thorndyke B, Luxton G and Le Q T 2007 Quantification of motion of different thoracic locations using four-dimensional computed tomography: implications for radiotherapy planning Int. J. Radiat. Oncol. Biol. Phys. 69 1395-401
    • (2007) Int. J. Radiat. Oncol. Biol. Phys. , vol.69 , pp. 1395-1401
    • Maxim, P.G.1    Loo, B.W.2    Shirazi, H.3    Thorndyke, B.4    Luxton, G.5    Le, Q.T.6
  • 11
    • 33847662456 scopus 로고    scopus 로고
    • Four-dimensional measurement of lung tumor displacement using 256-multi-slice CT-scanner
    • Mori S, Endo M, Komatsu S, Yashiro T, Kandatsu S and Baba M 2007 Four-dimensional measurement of lung tumor displacement using 256-multi-slice CT-scanner Lung Cancer 56 59-67
    • (2007) Lung Cancer , vol.56 , pp. 59-67
    • Mori, S.1    Endo, M.2    Komatsu, S.3    Yashiro, T.4    Kandatsu, S.5    Baba, M.6
  • 12
    • 56349142559 scopus 로고    scopus 로고
    • A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy
    • Poulsen P R, Cho B and Keall P J 2008 A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 72 1587-96
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.72 , pp. 1587-1596
    • Poulsen, P.R.1    Cho, B.2    Keall, P.J.3
  • 13
    • 34247117297 scopus 로고    scopus 로고
    • Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position
    • Purdie T G, Bissonnette J P, Franks K, Bezjak A, Payne D, Sie F, Sharpe M B and Jaffray D A 2007 Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position Int. J. Radiat. Oncol. Biol. Phys. 68 243-52
    • (2007) Int. J. Radiat. Oncol. Biol. Phys. , vol.68 , pp. 243-252
    • Purdie, T.G.1    Bissonnette, J.P.2    Franks, K.3    Bezjak, A.4    Payne, D.5    Sie, F.6    Sharpe, M.B.7    Jaffray, D.A.8
  • 14
    • 39049165539 scopus 로고    scopus 로고
    • Monitoring tumor motion with on-line mega-voltage cone-beam computed tomography imaging in a cine mode
    • Reitz B, Gayou O, Parda D S and Miften M 2008 Monitoring tumor motion with on-line mega-voltage cone-beam computed tomography imaging in a cine mode Phys. Med. Biol. 53 823-36
    • (2008) Phys. Med. Biol. , vol.53 , pp. 823-836
    • Reitz, B.1    Gayou, O.2    Parda, D.S.3    Miften, M.4
  • 15
    • 38849089948 scopus 로고    scopus 로고
    • Mean position tracking of respiratory motion
    • Ruan D, Fessler J A and Balter J M 2008 Mean position tracking of respiratory motion Med. Phys. 35 782-92
    • (2008) Med. Phys. , vol.35 , pp. 782-792
    • Ruan, D.1    Fessler, J.A.2    Balter, J.M.3
  • 18
    • 47649126554 scopus 로고    scopus 로고
    • An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients
    • Suh Y, Dieterich S, Cho B and Keall P J 2008 An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients Phys. Med. Biol. 53 3623-40
    • (2008) Phys. Med. Biol. , vol.53 , pp. 3623-3640
    • Suh, Y.1    Dieterich, S.2    Cho, B.3    Keall, P.J.4
  • 20
    • 0037422708 scopus 로고    scopus 로고
    • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
    • Vedam S S, Keall P J, Kini V R, Mostafavi H, Shukla H P and Mohan R 2003 Acquiring a four-dimensional computed tomography dataset using an external respiratory signal Phys. Med. Biol. 48 45-62
    • (2003) Phys. Med. Biol. , vol.48 , pp. 45-62
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3    Mostafavi, H.4    Shukla, H.P.5    Mohan, R.6
  • 21
    • 41449112602 scopus 로고    scopus 로고
    • Combined kV and MV imaging for real-time tracking of implanted fiducial markers
    • Wiersma R D, Mao W and Xing L 2008 Combined kV and MV imaging for real-time tracking of implanted fiducial markers Med. Phys. 35 1191-8
    • (2008) Med. Phys. , vol.35 , pp. 1191-1198
    • Wiersma, R.D.1    Mao, W.2    Xing, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.