메뉴 건너뛰기




Volumn 66, Issue 2, 2003, Pages 141-150

Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver

Author keywords

Computed tomography simulation; Conformal radiotherapy; Dose volume histogram; Stereotactic body frame; Stereotactic radiotherapy; Treatment accuracy

Indexed keywords

ACCURACY; ADOLESCENT; ADULT; AGED; ARTICLE; BREATHING; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETRY; FEMALE; HISTOGRAM; HUMAN; MALE; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION DOSE FRACTIONATION; REPRODUCIBILITY; SIMULATION; STEREOTAXIS; TREATMENT PLANNING;

EID: 0037296427     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(02)00372-9     Document Type: Article
Times cited : (70)

References (18)
  • 1
    • 0028855915 scopus 로고
    • Stereotactic high dose fractionation radiation therapy of extracranial tumors using an accelerator
    • Blomgren H., Lax I., Näslund I., Svanström R. Stereotactic high dose fractionation radiation therapy of extracranial tumors using an accelerator. Acta Oncol. 34:1995;861-870.
    • (1995) Acta Oncol , vol.34 , pp. 861-870
    • Blomgren, H.1    Lax, I.2    Näslund, I.3    Svanström, R.4
  • 2
    • 0003022389 scopus 로고    scopus 로고
    • Radiosurgery for tumors in the body: Clinical experience using a new method
    • Blomgren H., Lax I., Göranson H., et al. Radiosurgery for tumors in the body: clinical experience using a new method. J Radiosurg. 1:(1):1998;63-74.
    • (1998) J Radiosurg , vol.1 , Issue.1 , pp. 63-74
    • Blomgren, H.1    Lax, I.2    Göranson, H.3
  • 3
    • 0033977805 scopus 로고    scopus 로고
    • Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases
    • Herfarth K.K., Debus J., Lohr F., et al. Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases. Int J Radiat Oncol Biol Phys. 46:(2):2000;329-335.
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , Issue.2 , pp. 329-335
    • Herfarth, K.K.1    Debus, J.2    Lohr, F.3
  • 4
    • 0035154735 scopus 로고    scopus 로고
    • Stereotactic single dose radiation therapy of liver tumors: Results of a phase I/II trial
    • Herfarth K.K., Debus J., Lohr F., et al. Stereotactic single dose radiation therapy of liver tumors: results of a phase I/II trial. J Clin Oncol. 19:(1):2001;164-170.
    • (2001) J Clin Oncol , vol.19 , Issue.1 , pp. 164-170
    • Herfarth, K.K.1    Debus, J.2    Lohr, F.3
  • 5
    • 0027171867 scopus 로고
    • Target dose versus extra-target dose in stereotactic radiosurgery
    • Lax I. Target dose versus extra-target dose in stereotactic radiosurgery. Acta Oncol. 32:(4):1993;453-457.
    • (1993) Acta Oncol , vol.32 , Issue.4 , pp. 453-457
    • Lax, I.1
  • 6
    • 0027945954 scopus 로고
    • Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects
    • Lax I., Blomgren H., Näslund I., Svanström R. Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. Acta Oncol. 33:1994;677-683.
    • (1994) Acta Oncol , vol.33 , pp. 677-683
    • Lax, I.1    Blomgren, H.2    Näslund, I.3    Svanström, R.4
  • 7
    • 0001093617 scopus 로고    scopus 로고
    • Extracranial stereotactic radiosurgery of localized targets
    • Lax I., Blomgren H., Larson D., Näslund D. Extracranial stereotactic radiosurgery of localized targets. J Radiosurg. 1:(2):1998;135-148.
    • (1998) J Radiosurg , vol.1 , Issue.2 , pp. 135-148
    • Lax, I.1    Blomgren, H.2    Larson, D.3    Näslund, D.4
  • 8
    • 0033828191 scopus 로고    scopus 로고
    • Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: Original research in the treatment of thoracic neoplasms
    • Nakagawa K., Aoki Y., Tago M., Terahara A., Ohtomo K. Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: original research in the treatment of thoracic neoplasms. Int J Radiat Oncol Biol Phys. 48:(2):2000;449-457.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , Issue.2 , pp. 449-457
    • Nakagawa, K.1    Aoki, Y.2    Tago, M.3    Terahara, A.4    Ohtomo, K.5
  • 9
    • 0032919320 scopus 로고    scopus 로고
    • Three dimensional movement of a liver tumor detected by high-speed magnetic resonance
    • Shimizu S., Shirato H., Xo B., et al. Three dimensional movement of a liver tumor detected by high-speed magnetic resonance. Radiother Oncol. 50:1999;367-370.
    • (1999) Radiother Oncol , vol.50 , pp. 367-370
    • Shimizu, S.1    Shirato, H.2    Xo, B.3
  • 10
    • 0035479329 scopus 로고    scopus 로고
    • Detection of lung tumor movement in real-time tumor-tracking radiotherapy
    • Shimizu S., Shirato H., Ogura S., et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys. 51:(2):2001;304-310.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , Issue.2 , pp. 304-310
    • Shimizu, S.1    Shirato, H.2    Ogura, S.3
  • 11
    • 85031202500 scopus 로고    scopus 로고
    • 2300 East 14th Street, Tulsa, OK 74104, Tel.: +1-918-749-1119, fax: +1-918-749-2217, e-mail: info@statsoft.com, WEB. Tulsa, OK
    • StatSoft, Inc. STATISTICA für Windows [Computer- Programm-Handbuch]. StatSoft, Inc., 2300 East 14th Street, Tulsa, OK 74104, Tel.: +1-918-749-1119, fax: +1-918-749-2217, e-mail: info@statsoft.com, WEB: http://www.statsoft.com. Tulsa, OK, 1998.
    • (1998)
  • 12
    • 0032521265 scopus 로고    scopus 로고
    • Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients
    • Uematsu M., Shioda A., Tahara K., et al. Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients. Cancer. 82:1998;1062-1070.
    • (1998) Cancer , vol.82 , pp. 1062-1070
    • Uematsu, M.1    Shioda, A.2    Tahara, K.3
  • 13
    • 0032917269 scopus 로고    scopus 로고
    • Daily positioning accuracy of frameless stereotatctic radiation therapy with a fusion of computed tomography and linear accellarator (focal) unit: Evaluation of z-axis with a z-marker
    • Uematsu M., Sonderegger M., Shioda A., et al. Daily positioning accuracy of frameless stereotatctic radiation therapy with a fusion of computed tomography and linear accellarator (focal) unit: evaluation of z-axis with a z-marker. Radiother Oncol. 50:1999;337-339.
    • (1999) Radiother Oncol , vol.50 , pp. 337-339
    • Uematsu, M.1    Sonderegger, M.2    Shioda, A.3
  • 14
    • 0033831790 scopus 로고    scopus 로고
    • Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (focal) unit
    • Uematsu M., Shioda M., Suda A., et al. Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (focal) unit. Int J Radiat Oncol Biol Phys. 48:(2):2000;443-448.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , Issue.2 , pp. 443-448
    • Uematsu, M.1    Shioda, M.2    Suda, A.3
  • 15
    • 0342617576 scopus 로고    scopus 로고
    • A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
    • Van't Riet A., Mak A.C.A., Moerland M.A., Elders L.H., Van der Zee W. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. Int J Radiat Oncol Biol Phys. 37:(3):1997;731-736.
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , Issue.3 , pp. 731-736
    • Van't Riet, A.1    Mak, A.C.A.2    Moerland, M.A.3    Elders, L.H.4    Van der Zee, W.5
  • 16
    • 0033013520 scopus 로고    scopus 로고
    • The use of active breathing control (ABC) to reduce margin for breathing motion
    • Wong J.W., Sharpe M.B., Jaffray D.A., et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys. 44:(4):1999;911-919.
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , Issue.4 , pp. 911-919
    • Wong, J.W.1    Sharpe, M.B.2    Jaffray, D.A.3
  • 17
    • 0034332698 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame
    • Wulf J., Haedinger U., Oppitz U., Olshausen B., Flentje M. Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. Radiother Oncol. 57:2000;225-236.
    • (2000) Radiother Oncol , vol.57 , pp. 225-236
    • Wulf, J.1    Haedinger, U.2    Oppitz, U.3    Olshausen, B.4    Flentje, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.