메뉴 건너뛰기




Volumn 35, Issue 4, 2008, Pages 1191-1198

Combined kV and MV imaging for real-time tracking of implanted fiducial markers

Author keywords

4D radiotherapy; EPID; Marker tracking; OBI

Indexed keywords

COMPUTER HARDWARE DESCRIPTION LANGUAGES; DIAGNOSIS; TUMORS;

EID: 41449112602     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2842072     Document Type: Article
Times cited : (120)

References (32)
  • 1
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • 0094-2405 10.1118/1.1591194
    • G. A. Ezzell, " Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee., " Med. Phys. 0094-2405 10.1118/1.1591194 30, 2089-2115 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2089-2115
    • Ezzell, G.A.1
  • 3
    • 0842284569 scopus 로고    scopus 로고
    • Intrafractional tumor motion: Lung and liver
    • 1053-4296
    • H. Shirato, " Intrafractional tumor motion: Lung and liver., " Semin. Radiat. Oncol. 14, 10-18 (2004). 1053-4296
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 10-18
    • Shirato, H.1
  • 4
    • 33645347668 scopus 로고    scopus 로고
    • Overview of image-guided radiation therapy
    • 0958-3947
    • L. Xing, " Overview of image-guided radiation therapy., " Med. Dosim. 31, 91-112 (2006). 0958-3947
    • (2006) Med. Dosim. , vol.31 , pp. 91-112
    • Xing, L.1
  • 5
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • 1053-4296
    • M. van Herk, " Errors and margins in radiotherapy., " Semin. Radiat. Oncol. 14, 52-64 (2004). 1053-4296
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 52-64
    • Van Herk, M.1
  • 6
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • 0360-3016 10.1016/S0360-3016(99)00154-6
    • J. Hanley, " Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation., " Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/S0360-3016(99)00154-6 45, 603-611 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.45 , pp. 603-611
    • Hanley, J.1
  • 7
    • 0034006554 scopus 로고    scopus 로고
    • Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center
    • 0094-2405 10.1118/1.598837
    • H. D. Kubo, " Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center., " Med. Phys. 0094-2405 10.1118/1.598837 27, 346 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 346
    • Kubo, H.D.1
  • 8
    • 0034762764 scopus 로고    scopus 로고
    • Determining parameters for respiration-gated radiotherapy
    • 0094-2405 10.1118/1.1406524
    • S. S. Vedam, " Determining parameters for respiration-gated radiotherapy., " Med. Phys. 0094-2405 10.1118/1.1406524 28, 2139-2146 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2139-2146
    • Vedam, S.S.1
  • 9
    • 31044436279 scopus 로고    scopus 로고
    • Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system
    • 0094-2405 10.1118/1.2147743
    • X. A. Li, C. Stepaniak, and E. Gore, " Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system., " Med. Phys. 0094-2405 10.1118/1.2147743 33, 145-154 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 145-154
    • Li, X.A.1    Stepaniak, C.2    Gore, E.3
  • 10
    • 84973385381 scopus 로고    scopus 로고
    • Individualized gating windows based on four-dimensional CT information for respiration gated radiotherapy
    • 0031-9155
    • N. Wink, " Individualized gating windows based on four-dimensional CT information for respiration gated radiotherapy., " Med. Phys. 34, 2384 (2007). 0031-9155
    • (2007) Med. Phys. , vol.34 , pp. 2384
    • Wink, N.1
  • 11
    • 0033743945 scopus 로고    scopus 로고
    • Robotic motion compensation for respiratory movement during radiosurgery
    • 1092-9088
    • A. Schweikard, " Robotic motion compensation for respiratory movement during radiosurgery., " Comput. Aided Surg. 5, 263-277 (2000). 1092-9088
    • (2000) Comput. Aided Surg. , vol.5 , pp. 263-277
    • Schweikard, A.1
  • 12
    • 41449083593 scopus 로고    scopus 로고
    • A four-dimensional controller for DMLC-based tumor tracking
    • 0360-3016
    • P. J. Keall, " A four-dimensional controller for DMLC-based tumor tracking., " Int. J. Radiat. Oncol., Biol., Phys. 60, S338-S339 (2004). 0360-3016
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.60
    • Keall, P.J.1
  • 13
    • 41449103673 scopus 로고    scopus 로고
    • Synchrony-Real-time respiratory compensation system for the CyberKnife
    • 0094-2405
    • C. Ozhasoglu, " Synchrony-Real-time respiratory compensation system for the CyberKnife., " Med. Phys. 33, 2245-2246 (2006). 0094-2405
    • (2006) Med. Phys. , vol.33 , pp. 2245-2246
    • Ozhasoglu, C.1
  • 14
    • 0035136220 scopus 로고    scopus 로고
    • Motion adaptive x-ray therapy: A feasibility study
    • 0031-9155 10.1088/0031-9155/46/1/301
    • P. J. Keall, " Motion adaptive x-ray therapy: A feasibility study., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/46/1/301 46, 1-10 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1-10
    • Keall, P.J.1
  • 15
    • 0037423954 scopus 로고    scopus 로고
    • Synchronized moving aperture radiation therapy (SMART): Average tumour trajectory for lung patients
    • 0031-9155 10.1088/0031-9155/48/5/303
    • T. Neicu, " Synchronized moving aperture radiation therapy (SMART): Average tumour trajectory for lung patients., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/48/5/303 48, 587-598 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 587-598
    • Neicu, T.1
  • 16
    • 0038530967 scopus 로고    scopus 로고
    • The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
    • 0895-7177 10.1016/S0895-7177(03)00081-5
    • L. Papiez, " The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery., " Math. Comput. Modell. 0895-7177 10.1016/S0895-7177(03)00081-5 37, 735-745 (2003).
    • (2003) Math. Comput. Modell. , vol.37 , pp. 735-745
    • Papiez, L.1
  • 17
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: A technical study
    • 0031-9155 10.1088/0031-9155/41/1/007
    • H. D. Kubo and B. C. Hill, " Respiration gated radiotherapy treatment: A technical study., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/41/1/007 41, 83-91 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 18
    • 0036535315 scopus 로고    scopus 로고
    • Issues in respiratory motion compensation during external-beam radiotherapy
    • 0360-3016 10.1016/S0360-3016(01)02789-4
    • C. Ozhasoglu and M. J. Murphy, " Issues in respiratory motion compensation during external-beam radiotherapy., " Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/S0360-3016(01)02789-4 52, 1389-1399 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.52 , pp. 1389-1399
    • Ozhasoglu, C.1    Murphy, M.J.2
  • 19
    • 24944455908 scopus 로고    scopus 로고
    • Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy
    • 0360-3016 10.1016/j.ijrob2005.05.020
    • L. Simon, " Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy., " Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2005.05.020 63, 602-609 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.63 , pp. 602-609
    • Simon, L.1
  • 20
    • 0037391655 scopus 로고    scopus 로고
    • Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker
    • 0094-2405 10.1118/1.1558675
    • S. S. Vedam, " Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker., " Med. Phys. 0094-2405 10.1118/1.1558675 30, 505-513 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 505-513
    • Vedam, S.S.1
  • 21
    • 7444237095 scopus 로고    scopus 로고
    • Correlation of lung tumor motion with external surrogate indicators of respiration
    • 0360-3016 10.1016/j.ijrob2004.07.681
    • J. D. P. Hoisak, " Correlation of lung tumor motion with external surrogate indicators of respiration., " Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 10.1016/j.ijrobp.2004.07.681 60, 1298-1306 (2004).
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.60 , pp. 1298-1306
    • Hoisak, J.D.P.1
  • 22
    • 0942277196 scopus 로고    scopus 로고
    • Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
    • 0031-9155 10.1088/0031-9155/49/2/005
    • R. I. Berbeco, " Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/2/005 49, 243-255 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 243-255
    • Berbeco, R.I.1
  • 23
    • 0033577447 scopus 로고    scopus 로고
    • Real-time tumour-tracking radiotherapy
    • 0140-6736 10.1016/S0140-6736(99)00700-X
    • H. Shirato, " Real-time tumour-tracking radiotherapy., " Lancet 0140-6736 10.1016/S0140-6736(99)00700-X 353, 1331-1332 (1999).
    • (1999) Lancet , vol.353 , pp. 1331-1332
    • Shirato, H.1
  • 24
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • 0360-3016
    • P. Kupelian, " Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy., " Int. J. Radiat. Oncol., Biol., Phys. 67, 1088-1098 (2007). 0360-3016
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.67 , pp. 1088-1098
    • Kupelian, P.1
  • 25
    • 11244294832 scopus 로고    scopus 로고
    • On the use of EPID-based implanted marker tracking for 4D radiotherapy
    • 0094-2405 10.1118/1.1812608
    • P. J. Keall, " On the use of EPID-based implanted marker tracking for 4D radiotherapy., " Med. Phys. 0094-2405 10.1118/1.1812608 31, 3492-3499 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3492-3499
    • Keall, P.J.1
  • 26
    • 85027221394 scopus 로고    scopus 로고
    • Roborealm, http://roborealm.com/.
    • Roborealm
  • 27
    • 34547275812 scopus 로고    scopus 로고
    • Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking
    • 0094-2405
    • X. L. Tang, G. C. Sharp, and S. B. Jiang, " Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking., " Phys. Med. Biol. 52, 4081-4098 (2007). 0094-2405
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4081-4098
    • Tang, X.L.1    Sharp, G.C.2    Jiang, S.B.3
  • 28
    • 34748915716 scopus 로고    scopus 로고
    • Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy
    • 0094-2405
    • R. D. Wiersma and L. Xing, " Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy., " Med. Phys. 34, 3962-3970. 0094-2405
    • Med. Phys. , vol.34 , pp. 3962-3970
    • Wiersma, R.D.1    Xing, L.2
  • 29
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    • 0031-9155 10.1088/0031-9155/49/3/006
    • G. C. Sharp, " Prediction of respiratory tumour motion for real-time image-guided radiotherapy., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/3/006 49, 425-440 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 425-440
    • Sharp, G.C.1
  • 30
    • 4043151643 scopus 로고    scopus 로고
    • Predicting respiratory motion for four-dimensional radiotherapy
    • 0094-2405 10.1118/1.1771931
    • S. S. Vedam, " Predicting respiratory motion for four-dimensional radiotherapy., " Med. Phys. 0094-2405 10.1118/1.1771931 31, 2274-2283 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2274-2283
    • Vedam, S.S.1
  • 31
    • 0842349454 scopus 로고    scopus 로고
    • Tracking moving organs in real time
    • 1053-4296
    • M. J. Murphy, " Tracking moving organs in real time., " Semin. Radiat. Oncol. 14, 91-100 (2004). 1053-4296
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 91-100
    • Murphy, M.J.1
  • 32
    • 41449115859 scopus 로고    scopus 로고
    • Multiplexing radiography for ultra-fast computed tomography: A feasibility study
    • 0094-2405
    • J. Zhang, " Multiplexing radiography for ultra-fast computed tomography: A feasibility study., " Med. Phys. 34, 2527 (2007). 0094-2405
    • (2007) Med. Phys. , vol.34 , pp. 2527
    • Zhang, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.