메뉴 건너뛰기




Volumn 75, Issue 1, 2009, Pages 302-308

Inter- and Intrafraction Variability in Liver Position in Non-Breath-Hold Stereotactic Body Radiotherapy

Author keywords

CBCT; IGRT; Image guided radiotherapy; Intrafraction reproducibility; kilovoltage cone beam computed tomography

Indexed keywords

CBCT; IGRT; IMAGE-GUIDED RADIOTHERAPY; INTRAFRACTION REPRODUCIBILITY; KILOVOLTAGE CONE-BEAM COMPUTED TOMOGRAPHY;

EID: 68649087156     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2009.03.058     Document Type: Article
Times cited : (131)

References (36)
  • 1
    • 33748876430 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of primary liver cancer and hepatic metastases
    • Wulf J., Guckenberger M., Haedinger U., et al. Stereotactic radiotherapy of primary liver cancer and hepatic metastases. Acta Oncol 45 (2006) 838-847
    • (2006) Acta Oncol , vol.45 , pp. 838-847
    • Wulf, J.1    Guckenberger, M.2    Haedinger, U.3
  • 2
    • 39149134352 scopus 로고    scopus 로고
    • Phase I study of individualized stereotactic body radiotherapy for hepatocellular carcinoma and intrahepatic cholangiocarcinoma
    • Tse R.V., Hawkins M., Lockwood G., et al. Phase I study of individualized stereotactic body radiotherapy for hepatocellular carcinoma and intrahepatic cholangiocarcinoma. J Clin Oncol 26 (2008) 657-664
    • (2008) J Clin Oncol , vol.26 , pp. 657-664
    • Tse, R.V.1    Hawkins, M.2    Lockwood, G.3
  • 3
    • 33947498981 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy in multiple organ sites
    • Timmerman R.D., Kavanagh B.D., Cho L.C., et al. Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol 25 (2007) 947-952
    • (2007) J Clin Oncol , vol.25 , pp. 947-952
    • Timmerman, R.D.1    Kavanagh, B.D.2    Cho, L.C.3
  • 4
    • 68649088007 scopus 로고    scopus 로고
    • Hypofractionated stereotactic body radiation therapy for liver metastases
    • Sampson M.C., Schell M., Okunieff P., et al. Hypofractionated stereotactic body radiation therapy for liver metastases. Int J Radiat Oncol Biol Phys 63 (2005) s15
    • (2005) Int J Radiat Oncol Biol Phys , vol.63
    • Sampson, M.C.1    Schell, M.2    Okunieff, P.3
  • 5
    • 33748855420 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase I-II study
    • Romero A.M., Wunderink W., Hussain S.M., et al. Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase I-II study. Acta Oncol 45 (2006) 831-837
    • (2006) Acta Oncol , vol.45 , pp. 831-837
    • Romero, A.M.1    Wunderink, W.2    Hussain, S.M.3
  • 6
    • 33748865018 scopus 로고    scopus 로고
    • Individualized image guided iso-NTCP based liver cancer SBRT
    • Dawson L.A., Eccles C., and Craig T. Individualized image guided iso-NTCP based liver cancer SBRT. Acta Oncol 45 (2006) 856-864
    • (2006) Acta Oncol , vol.45 , pp. 856-864
    • Dawson, L.A.1    Eccles, C.2    Craig, T.3
  • 7
    • 31844444644 scopus 로고    scopus 로고
    • Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy
    • Eccles C.B., Brock K., Bissonnette J.-P., et al. Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. Int J Radiat Oncol Biol Phys 64 (2006) 751-759
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 751-759
    • Eccles, C.B.1    Brock, K.2    Bissonnette, J.-P.3
  • 8
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • Mageras G., and Yorke E. Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. Semin Radiat Oncol 14 (2004) 65-75
    • (2004) Semin Radiat Oncol , vol.14 , pp. 65-75
    • Mageras, G.1    Yorke, E.2
  • 9
    • 68649119703 scopus 로고    scopus 로고
    • Variability in liver motion amplitude in patients undergoing free breathing stereotactic body radiotherapy
    • Case R.B., Moseley D.J., Bissonnette J.-P., et al. Variability in liver motion amplitude in patients undergoing free breathing stereotactic body radiotherapy. Radiother Oncol 84 Suppl. 2 (2007) S38
    • (2007) Radiother Oncol , vol.84 , Issue.SUPPL. 2
    • Case, R.B.1    Moseley, D.J.2    Bissonnette, J.-P.3
  • 10
    • 0033577447 scopus 로고    scopus 로고
    • Real-time tumour-tracking radiotherapy
    • Shirato H., Shimizu S., Shimizu T., et al. Real-time tumour-tracking radiotherapy. Lancet 353 (1999) 1331-1332
    • (1999) Lancet , vol.353 , pp. 1331-1332
    • Shirato, H.1    Shimizu, S.2    Shimizu, T.3
  • 11
    • 0842306300 scopus 로고    scopus 로고
    • 4-Dimensional computed tomography imaging and treatment planning
    • Keall P.J. 4-Dimensional computed tomography imaging and treatment planning. Semin Radiat Oncol 14 (2004) 81-90
    • (2004) Semin Radiat Oncol , vol.14 , pp. 81-90
    • Keall, P.J.1
  • 12
    • 33748865018 scopus 로고    scopus 로고
    • Individualized image guided iso-NTCP based liver cancer SBRT
    • Dawson L.A., Eccles C., and Craig T. Individualized image guided iso-NTCP based liver cancer SBRT. Acta Oncol 45 (2006) 856-864
    • (2006) Acta Oncol , vol.45 , pp. 856-864
    • Dawson, L.A.1    Eccles, C.2    Craig, T.3
  • 13
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • Sonke J.-J., Zijp L., Remeijer P., et al. Respiratory correlated cone beam CT. Med Phys 32 (2005) 1176-1186
    • (2005) Med Phys , vol.32 , pp. 1176-1186
    • Sonke, J.-J.1    Zijp, L.2    Remeijer, P.3
  • 14
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 14 (2004) 52-64
    • (2004) Semin Radiat Oncol , vol.14 , pp. 52-64
    • van Herk, M.1
  • 15
    • 0033831790 scopus 로고    scopus 로고
    • Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit
    • Uematsu M., Shioda A., Suda A., et al. Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit. Int J Radiat Oncol Biol Phys 48 (2000) 443-448
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 443-448
    • Uematsu, M.1    Shioda, A.2    Suda, A.3
  • 16
    • 0037296854 scopus 로고    scopus 로고
    • A new irradiation unit constructed of self-moving gantry-CT and LINAC
    • Kuriyama K., Onishi H., Sano N., et al. A new irradiation unit constructed of self-moving gantry-CT and LINAC. Int J Radiat Oncol Biol Phys 55 (2003) 428-435
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 428-435
    • Kuriyama, K.1    Onishi, H.2    Sano, N.3
  • 17
    • 33644540547 scopus 로고    scopus 로고
    • A technique for adaptive image-guided helical tomotherapy for lung cancer
    • Ramsey C.R., Langen K.M., Kupelian P.A., et al. A technique for adaptive image-guided helical tomotherapy for lung cancer. Int J Radiat Oncol Biol Phys 64 (2006) 1237-1244
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1237-1244
    • Ramsey, C.R.1    Langen, K.M.2    Kupelian, P.A.3
  • 18
    • 34547492914 scopus 로고    scopus 로고
    • Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization
    • Gayou O., and Miften M. Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization. Med Phys 34 (2007) 3183-3192
    • (2007) Med Phys , vol.34 , pp. 3183-3192
    • Gayou, O.1    Miften, M.2
  • 19
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • Jaffray D.A., Siewerdsen J.H., Wong J.W., et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53 (2002) 1337-1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 20
    • 33749046687 scopus 로고    scopus 로고
    • Image-guided radiotherapy: Rationale, benefits, and limitations
    • Dawson L.A., and Sharpe M.B. Image-guided radiotherapy: Rationale, benefits, and limitations. Lancet Oncol 7 (2006) 848-858
    • (2006) Lancet Oncol , vol.7 , pp. 848-858
    • Dawson, L.A.1    Sharpe, M.B.2
  • 21
    • 0032917269 scopus 로고    scopus 로고
    • Daily positioning accuracy of frameless stereotactic radiation therapy with a fusion of computed tomography and linear accelerator (focal) unit: Evaluation of z-axis with a z-marker
    • Uematsu M., Sonderegger M., Shioda A., et al. Daily positioning accuracy of frameless stereotactic radiation therapy with a fusion of computed tomography and linear accelerator (focal) unit: Evaluation of z-axis with a z-marker. Radiother Oncol 50 (1999) 337-339
    • (1999) Radiother Oncol , vol.50 , pp. 337-339
    • Uematsu, M.1    Sonderegger, M.2    Shioda, A.3
  • 22
    • 0035450996 scopus 로고    scopus 로고
    • Determination of ventilatory liver movement via radiographic evaluation of diaphragm position
    • Balter J.M., Dawson L.A., Kazanjian S., et al. Determination of ventilatory liver movement via radiographic evaluation of diaphragm position. Int J Radiat Oncol Biol Phys 51 (2001) 267-270
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 267-270
    • Balter, J.M.1    Dawson, L.A.2    Kazanjian, S.3
  • 23
    • 41749104005 scopus 로고    scopus 로고
    • Image-guided radiotherapy for liver cancer using respiratory-correlated computed tomography and cone-beam computed tomography
    • Guckenberger M., Sweeney R.A., Wilbert J., et al. Image-guided radiotherapy for liver cancer using respiratory-correlated computed tomography and cone-beam computed tomography. Int J Radiat Oncol Biol Phys 71 (2008) 297-304
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 297-304
    • Guckenberger, M.1    Sweeney, R.A.2    Wilbert, J.3
  • 24
    • 36148932560 scopus 로고    scopus 로고
    • On-line target position localization in the presence of respiration: A comparison of two methods
    • Hugo G.D., Liang J., Campbell J., et al. On-line target position localization in the presence of respiration: A comparison of two methods. Int J Radiat Oncol Biol Phys 69 (2007) 1634-1641
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 1634-1641
    • Hugo, G.D.1    Liang, J.2    Campbell, J.3
  • 25
    • 0033977805 scopus 로고    scopus 로고
    • Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases
    • Herfarth K.K., Lohr F., Bahner M.L., et al. Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases. Int J Radiat Oncol Biol Phys 46 (2000) 329-335
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 329-335
    • Herfarth, K.K.1    Lohr, F.2    Bahner, M.L.3
  • 26
    • 33748875872 scopus 로고    scopus 로고
    • Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    • Guckenberger M., Meyer J., Wilbert J., et al. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol 45 (2006) 897-906
    • (2006) Acta Oncol , vol.45 , pp. 897-906
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 27
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • Sonke J.J., Lebesque J., and van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys 70 (2008) 590-598
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    van Herk, M.3
  • 28
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., Kitamura K., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53 (2002) 822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 29
    • 34047145827 scopus 로고    scopus 로고
    • Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    • Guckenberger M., Meyer J., Wilbert J., et al. Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol 83 (2007) 57-64
    • (2007) Radiother Oncol , vol.83 , pp. 57-64
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 30
    • 34247117297 scopus 로고    scopus 로고
    • Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position
    • Purdie T.G., Bissonnette J.-P., Franks K., et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68 (2007) 243-252
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 243-252
    • Purdie, T.G.1    Bissonnette, J.-P.2    Franks, K.3
  • 31
    • 0035577652 scopus 로고    scopus 로고
    • The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy
    • Dawson L.A., Brock K.K., Kazanjian S., et al. The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. Int J Radiat Oncol Biol Phys 51 (2001) 1410-1421
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1410-1421
    • Dawson, L.A.1    Brock, K.K.2    Kazanjian, S.3
  • 32
    • 33645972885 scopus 로고    scopus 로고
    • Changes in the respiratory pattern during radiotherapy for cancer in the lung
    • Hugo G., Vargas C., Liang J., et al. Changes in the respiratory pattern during radiotherapy for cancer in the lung. Radiother Oncol 78 (2006) 326-331
    • (2006) Radiother Oncol , vol.78 , pp. 326-331
    • Hugo, G.1    Vargas, C.2    Liang, J.3
  • 33
    • 34447100119 scopus 로고    scopus 로고
    • Intra- and interfraction breathing variations during curative radiotherapy for lung cancer
    • Nøttrup J., Korreman S.S., Pedersen A.N., et al. Intra- and interfraction breathing variations during curative radiotherapy for lung cancer. Radiother Oncol 84 (2007) 40-48
    • (2007) Radiother Oncol , vol.84 , pp. 40-48
    • Nøttrup, J.1    Korreman, S.S.2    Pedersen, A.N.3
  • 34
    • 45449088673 scopus 로고    scopus 로고
    • Observations on real-time prostate gland motion using electromagnetic tracking
    • Langdon K.M., Willoughby T.R., Meeks S.L., et al. Observations on real-time prostate gland motion using electromagnetic tracking. Int J Radiat Oncol Biol Phys 71 4 (2008) 1084-1090
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , Issue.4 , pp. 1084-1090
    • Langdon, K.M.1    Willoughby, T.R.2    Meeks, S.L.3
  • 35
    • 34548301696 scopus 로고    scopus 로고
    • Systematic errors in respiratory gating due to intrafraction deformations of the liver
    • von Siebenthal M., Szekely G., Lomax A., et al. Systematic errors in respiratory gating due to intrafraction deformations of the liver. Med Phys 34 (2007) 3620-3629
    • (2007) Med Phys , vol.34 , pp. 3620-3629
    • von Siebenthal, M.1    Szekely, G.2    Lomax, A.3
  • 36
    • 51049123184 scopus 로고    scopus 로고
    • Improving image-guided target localization through deformable registration. IGRT 2008 special
    • Brock K.K., Hawkins M., Eccles C., et al. Improving image-guided target localization through deformable registration. IGRT 2008 special. Acta Oncol 47 (2008) 1279-1285
    • (2008) Acta Oncol , vol.47 , pp. 1279-1285
    • Brock, K.K.1    Hawkins, M.2    Eccles, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.