메뉴 건너뛰기




Volumn 60, Issue 1, 2004, Pages 335-341

Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy

Author keywords

Dosimetry; Fluoroscopy; Real time tumor tracking radiotherapy

Indexed keywords

BEAM ENERGY; FLUOROSCOPY; REAL-TIME TUMOR-TRACKING RADIOTHERAPY (RTRT);

EID: 4444313627     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2004.04.028     Document Type: Article
Times cited : (89)

References (25)
  • 1
    • 0345269966 scopus 로고    scopus 로고
    • Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy
    • Shirato H., Harada T., Harabayashi T., et al. Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys. 56:2003;240-247
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 240-247
    • Shirato, H.1    Harada, T.2    Harabayashi, T.3
  • 2
    • 0034566036 scopus 로고    scopus 로고
    • Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers
    • Shimizu S., Shirato H., Kitamura K., et al. Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys. 48:2000;1591-1597
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1591-1597
    • Shimizu, S.1    Shirato, H.2    Kitamura, K.3
  • 3
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • Kitamura K., Shirato H., Shimizu S., et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol. 62:2002;275-281
    • (2002) Radiother Oncol , vol.62 , pp. 275-281
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3
  • 4
    • 0036803209 scopus 로고    scopus 로고
    • Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers
    • Kaatee R.S., Olofsen M.J., Verstraate M.B., et al. Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers. Int J Radiat Oncol Biol Phys. 54:2002;576-583
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , pp. 576-583
    • Kaatee, R.S.1    Olofsen, M.J.2    Verstraate, M.B.3
  • 6
    • 0035479329 scopus 로고    scopus 로고
    • Detection of lung tumor movement in real-time tumor-tracking radiotherapy
    • Shimizu S., Shirato H., Ogura S., et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys. 51:2001;304-310
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 304-310
    • Shimizu, S.1    Shirato, H.2    Ogura, S.3
  • 7
    • 0036127077 scopus 로고    scopus 로고
    • Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy
    • Kubo H.D., Wang L. Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy. Med Phys. 29:2002;345-350
    • (2002) Med Phys , vol.29 , pp. 345-350
    • Kubo, H.D.1    Wang, L.2
  • 8
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., Kitamura K., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys. 53:2002;822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 9
    • 0037108188 scopus 로고    scopus 로고
    • Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy
    • Harada T., Shirato H., Ogura S., et al. Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy. Cancer. 95:2002;1720-1727
    • (2002) Cancer , vol.95 , pp. 1720-1727
    • Harada, T.1    Shirato, H.2    Ogura, S.3
  • 10
    • 0037403214 scopus 로고    scopus 로고
    • Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system
    • Kitamura K., Shirato H., Seppenwoolde Y., et al. Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system. Int J Radiat Oncol Biol Phys. 56:2003;221-228
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 221-228
    • Kitamura, K.1    Shirato, H.2    Seppenwoolde, Y.3
  • 11
    • 0034237599 scopus 로고    scopus 로고
    • Respiratory gated irradiation system for heavy-ion radiotherapy
    • Minohara S., Kanai T., Endo M., et al. Respiratory gated irradiation system for heavy-ion radiotherapy. Int J Radiat Oncol Biol Phys. 47:2000;1097-1103
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1097-1103
    • Minohara, S.1    Kanai, T.2    Endo, M.3
  • 12
    • 0033824313 scopus 로고    scopus 로고
    • Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    • Shirato H., Shimizu S., Kitamura K., et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys. 48:2000;435-442
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 435-442
    • Shirato, H.1    Shimizu, S.2    Kitamura, K.3
  • 13
    • 0037422708 scopus 로고    scopus 로고
    • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
    • Vedam S.S., Keall P.J., Kini V.R., et al. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol. 48:2003;45-62
    • (2003) Phys Med Biol , vol.48 , pp. 45-62
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3
  • 14
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning
    • Ford E.C., Mageras G.S., Yorke E., et al. Respiration-correlated spiral CT A method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys. 30:2003;88-97
    • (2003) Med Phys , vol.30 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3
  • 15
    • 0035996423 scopus 로고    scopus 로고
    • Technical note: Creating a four-dimensional model of the liver using finite element analysis
    • Brock K.K., Hollister S.J., Dawson L.A., et al. Technical note Creating a four-dimensional model of the liver using finite element analysis. Med Phys. 29:2002;1403-1405
    • (2002) Med Phys , vol.29 , pp. 1403-1405
    • Brock, K.K.1    Hollister, S.J.2    Dawson, L.A.3
  • 16
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • Shirato H., Shimizu S., Kunieda T., et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys. 48:2000;1187-1195
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1187-1195
    • Shirato, H.1    Shimizu, S.2    Kunieda, T.3
  • 17
    • 0037423954 scopus 로고    scopus 로고
    • Synchronized moving aperture radiation therapy (SMART) Average tumour trajectory for lung patients
    • Neicu T., Shirato H., Seppenwoolde Y., et al. Synchronized moving aperture radiation therapy (SMART) Average tumour trajectory for lung patients. Phys Med Biol. 48:2003;587-598
    • (2003) Phys Med Biol , vol.48 , pp. 587-598
    • Neicu, T.1    Shirato, H.2    Seppenwoolde, Y.3
  • 18
    • 0036941905 scopus 로고    scopus 로고
    • Patient and occupational dose in neurointerventional procedures
    • Kemerink G.J., Frantzen M.J., Oei K., et al. Patient and occupational dose in neurointerventional procedures. Neuroradiology. 44:2002;522-528
    • (2002) Neuroradiology , vol.44 , pp. 522-528
    • Kemerink, G.J.1    Frantzen, M.J.2    Oei, K.3
  • 19
    • 0035999401 scopus 로고    scopus 로고
    • Adult patient doses in interventional neuroradiology
    • Gkanatsios N.A., Huda W., Peters K.R. Adult patient doses in interventional neuroradiology. Med Phys. 29:2002;717-723
    • (2002) Med Phys , vol.29 , pp. 717-723
    • Gkanatsios, N.A.1    Huda, W.2    Peters, K.R.3
  • 20
    • 84912681200 scopus 로고    scopus 로고
    • Central axis depth dose data for use in radiotherapy
    • Joint Working Party of the British Institute of Radiology and the Hospital Physicists' Association. Central axis depth dose data for use in radiotherapy. Br J Radiol 1996;(Suppl. 25)
    • (1996) Br J Radiol , Issue.25 SUPPL.
  • 21
    • 0020859154 scopus 로고
    • X-rays: Half-value thickness range 0.01-8.0 mm Al
    • Jennings W.A., Harrison R.M. X-rays Half-value thickness range 0.01-8.0 mm Al. Br J Radiol. 17:1983;1-7
    • (1983) Br J Radiol , vol.17 , pp. 1-7
    • Jennings, W.A.1    Harrison, R.M.2
  • 22
    • 0019453564 scopus 로고
    • Central-axis depth-dose data for diagnostic radiology
    • Harrison R.M. Central-axis depth-dose data for diagnostic radiology. Phys Med Biol. 26:1981;657-670
    • (1981) Phys Med Biol , vol.26 , pp. 657-670
    • Harrison, R.M.1
  • 23
    • 0035117218 scopus 로고    scopus 로고
    • Measurement of the dose deposition characteristics of x-ray fluoroscopy beams in water
    • Fetterly K.A., Gerbi B.J., Alaei P., et al. Measurement of the dose deposition characteristics of x-ray fluoroscopy beams in water. Med Phys. 28:2001;205-209
    • (2001) Med Phys , vol.28 , pp. 205-209
    • Fetterly, K.A.1    Gerbi, B.J.2    Alaei, P.3
  • 24
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumor motion for real-time image-guided radiotherapy
    • Sharp G., Jiang S.B., Shimizu S., et al. Prediction of respiratory tumor motion for real-time image-guided radiotherapy. Phys Med Biol. 49:2004;425-440
    • (2004) Phys Med Biol , vol.49 , pp. 425-440
    • Sharp, G.1    Jiang, S.B.2    Shimizu, S.3
  • 25
    • 0033799790 scopus 로고    scopus 로고
    • A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy
    • Seiler P.G., Blattmann H., Kirsch S., et al. A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. Phys Med Biol. 45:2000;N103-N110
    • (2000) Phys Med Biol , vol.45
    • Seiler, P.G.1    Blattmann, H.2    Kirsch, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.