메뉴 건너뛰기




Volumn 30, Issue 11, 2012, Pages 1822-1829

Bone remodeling after total hip arthroplasty with a short stemmed metaphyseal loading implant: Finite element analysis validated by a prospective DEXA investigation

Author keywords

bone remodeling; dual energy X ray absorptiometry; finite element analysis; short stemmed implant; total hip arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE MASS; BONE REMODELING; CEMENTLESS PROSTHESIS; CLINICAL ARTICLE; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR; FINITE ELEMENT ANALYSIS; GREATER TROCHANTER; HUMAN; MALE; METAPHYSIS; OSTEOLYSIS; PRIORITY JOURNAL; TOTAL HIP PROSTHESIS;

EID: 84867231759     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.22120     Document Type: Article
Times cited : (66)

References (34)
  • 1
    • 0033826988 scopus 로고    scopus 로고
    • A conservative femoral replacement for total hip arthroplasty. A prospective study
    • Morrey BF, Adams RA, Kessler M., 2000. A conservative femoral replacement for total hip arthroplasty. A prospective study. J Bone Joint Surg Br 82: 952-958.
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 952-958
    • Morrey, B.F.1    Adams, R.A.2    Kessler, M.3
  • 2
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R, Weinans H, van Rietbergen B., 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 274: 124-134.
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    Van Rietbergen, B.3
  • 3
    • 42649084679 scopus 로고    scopus 로고
    • Perspectives on metaphyseal conservative stems
    • Falez F, Casella F, Panegrossi G, et al. 2008. Perspectives on metaphyseal conservative stems. J Orthop Traumatol 9: 49-54.
    • (2008) J Orthop Traumatol , vol.9 , pp. 49-54
    • Falez, F.1    Casella, F.2    Panegrossi, G.3
  • 4
    • 33744951412 scopus 로고    scopus 로고
    • Bone remodelling in THA: A comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report
    • Albanese CV, Rendine M, De Palma F, et al. 2006. Bone remodelling in THA: a comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report. Hip Int 16: 9-15.
    • (2006) Hip Int , vol.16 , pp. 9-15
    • Albanese, C.V.1    Rendine, M.2    De Palma, F.3
  • 5
    • 34547746079 scopus 로고    scopus 로고
    • Bone remodelling after total hip arthroplasty using an uncemented anatomic femoral stem: A three-year prospective study using bone densitometry
    • Panisello JJ, Herrero L, Herrera A, et al. 2006. Bone remodelling after total hip arthroplasty using an uncemented anatomic femoral stem: a three-year prospective study using bone densitometry. J Orthop Surg (Hong Kong) 14: 32-37.
    • (2006) J Orthop Surg (Hong Kong) , vol.14 , pp. 32-37
    • Panisello, J.J.1    Herrero, L.2    Herrera, A.3
  • 6
    • 1642422398 scopus 로고    scopus 로고
    • Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty. A five-year longitudinal study
    • Brodner W, Bitzan P, Lomoschitz F, et al. 2004. Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty. A five-year longitudinal study. J Bone Joint Surg Br 86: 20-26.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 20-26
    • Brodner, W.1    Bitzan, P.2    Lomoschitz, F.3
  • 7
    • 35649019842 scopus 로고    scopus 로고
    • Modular short-stem prosthesis in total hip arthroplasty: Implant positioning and the influence of navigation
    • Braun A, Lazovic D, Zigan R., 2007. Modular short-stem prosthesis in total hip arthroplasty: implant positioning and the influence of navigation. Orthopedics 30: 148-152.
    • (2007) Orthopedics , vol.30 , pp. 148-152
    • Braun, A.1    Lazovic, D.2    Zigan, R.3
  • 9
    • 84859159994 scopus 로고    scopus 로고
    • Bone remodelling around the Metha short stem in total hip arthroplasty: A prospective dual-energy X-ray absorptiometry study
    • Lerch M, von der Haar-Tran A, Windhagen H, et al. 2011. Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study. Int Orthop 36: 533-538.
    • (2011) Int Orthop , vol.36 , pp. 533-538
    • Lerch, M.1    Von Der Haar-Tran, A.2    Windhagen, H.3
  • 10
    • 65649147588 scopus 로고    scopus 로고
    • Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: Influence of the boundary conditions
    • Behrens BA, Nolte I, Wefstaedt P, et al. 2009. Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions. Biomed Eng Online 8: 7.
    • (2009) Biomed Eng Online , vol.8 , pp. 7
    • Behrens, B.A.1    Nolte, I.2    Wefstaedt, P.3
  • 11
    • 0029329134 scopus 로고
    • Relations of mechanical properties to density and CT numbers in human bone
    • Rho JY, Hobatho MC, Ashman RB., 1995. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17: 347-355.
    • (1995) Med Eng Phys , vol.17 , pp. 347-355
    • Rho, J.Y.1    Hobatho, M.C.2    Ashman, R.B.3
  • 12
    • 34347244882 scopus 로고    scopus 로고
    • Physiologically based boundary conditions in finite element modelling
    • Speirs AD, Heller MO, Duda GN, et al. 2007. Physiologically based boundary conditions in finite element modelling. J Biomech 40: 2318-2323.
    • (2007) J Biomech , vol.40 , pp. 2318-2323
    • Speirs, A.D.1    Heller, M.O.2    Duda, G.N.3
  • 13
    • 0034989649 scopus 로고    scopus 로고
    • Duration and frequency of every day activities in total hip patients
    • Morlock M, Schneider E, Bluhm A, et al. 2001. Duration and frequency of every day activities in total hip patients. J Biomech 34: 873-881.
    • (2001) J Biomech , vol.34 , pp. 873-881
    • Morlock, M.1    Schneider, E.2    Bluhm, A.3
  • 14
    • 7044238389 scopus 로고    scopus 로고
    • The effect of muscle loading on the simulation of bone remodelling in the proximal femur
    • Bitsakos C, Kerner J, Fisher I, et al. 2005. The effect of muscle loading on the simulation of bone remodelling in the proximal femur. J Biomech 38: 133-139.
    • (2005) J Biomech , vol.38 , pp. 133-139
    • Bitsakos, C.1    Kerner, J.2    Fisher, I.3
  • 15
    • 0032168893 scopus 로고    scopus 로고
    • Influence of muscle forces on femoral strain distribution
    • Duda GN, Heller M, Albinger J, et al. 1998. Influence of muscle forces on femoral strain distribution. J Biomech 31: 841-846.
    • (1998) J Biomech , vol.31 , pp. 841-846
    • Duda, G.N.1    Heller, M.2    Albinger, J.3
  • 16
    • 15944383441 scopus 로고    scopus 로고
    • Determination of muscle loading at the hip joint for use in pre-clinical testing
    • Heller MO, Bergmann G, Kassi JP, et al. 2005. Determination of muscle loading at the hip joint for use in pre-clinical testing. J Biomech 38: 1155-1163.
    • (2005) J Biomech , vol.38 , pp. 1155-1163
    • Heller, M.O.1    Bergmann, G.2    Kassi, J.P.3
  • 17
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. 2001. Hip contact forces and gait patterns from routine activities. J Biomech 34: 859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 18
    • 0031239959 scopus 로고    scopus 로고
    • Internal forces and moments in the femur during walking
    • Duda GN, Schneider E, Chao EY., 1997. Internal forces and moments in the femur during walking. J Biomech 30: 933-941.
    • (1997) J Biomech , vol.30 , pp. 933-941
    • Duda, G.N.1    Schneider, E.2    Chao, E.Y.3
  • 19
    • 84872486592 scopus 로고    scopus 로고
    • Femoral load change and caused bone remodeling after hip arthroplasty.
    • Dössel O. Schlegel W.C. editors. Munich, Germany: Image Processing, Biosignal Processing, Modelling and Simulation; Biomechanics. 25/IV ed. Springer.
    • Behrens BA, Stukenborg-Colsman C, Nolte I, et al. 2009. Femoral load change and caused bone remodeling after hip arthroplasty. In:, Dössel O, Schlegel WC, editors. World Congress on Medical Physics and Biomedical Engineering, 7-12 September, 2009. Munich, Germany: Image Processing, Biosignal Processing, Modelling and Simulation; Biomechanics. 25/IV ed. Springer.
    • (2009) World Congress on Medical Physics and Biomedical Engineering, 7-12 September, 2009
    • Behrens, B.A.1    Stukenborg-Colsman, C.2    Nolte, I.3
  • 20
    • 33947687309 scopus 로고    scopus 로고
    • Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant
    • Speirs AD, Heller MO, Taylor WR, et al. 2007. Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. Clin Biomech (Bristol, Avon) 22: 431-439.
    • (2007) Clin Biomech (Bristol, Avon) , vol.22 , pp. 431-439
    • Speirs, A.D.1    Heller, M.O.2    Taylor, W.R.3
  • 21
    • 19344366964 scopus 로고    scopus 로고
    • Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration
    • Roth A, Richartz G, Sander K, et al. 2005. Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration. Orthopade 34: 334-344.
    • (2005) Orthopade , vol.34 , pp. 334-344
    • Roth, A.1    Richartz, G.2    Sander, K.3
  • 22
    • 0033826320 scopus 로고    scopus 로고
    • Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem
    • Martini F, Lebherz C, Mayer F, et al. 2000. Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82: 1065-1071.
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 1065-1071
    • Martini, F.1    Lebherz, C.2    Mayer, F.3
  • 23
    • 0030030581 scopus 로고    scopus 로고
    • Effect of rotation on periprosthetic bone mineral measurements in a hip phantom
    • Mortimer ES, Rosenthall L, Paterson I, et al. 1996. Effect of rotation on periprosthetic bone mineral measurements in a hip phantom. Clin Orthop Relat Res 324: 269-274.
    • (1996) Clin Orthop Relat Res , vol.324 , pp. 269-274
    • Mortimer, E.S.1    Rosenthall, L.2    Paterson, I.3
  • 24
    • 0036890483 scopus 로고    scopus 로고
    • Validation data for periprosthetic bone remodelling theories
    • Lengsfeld M, Gunther D, Pressel T, et al. 2002. Validation data for periprosthetic bone remodelling theories. J Biomech 35: 1553-1564.
    • (2002) J Biomech , vol.35 , pp. 1553-1564
    • Lengsfeld, M.1    Gunther, D.2    Pressel, T.3
  • 25
    • 0042838275 scopus 로고    scopus 로고
    • Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA
    • Aldinger PR, Sabo D, Pritsch M, et al. 2003. Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int 73: 115-121.
    • (2003) Calcif Tissue Int , vol.73 , pp. 115-121
    • Aldinger, P.R.1    Sabo, D.2    Pritsch, M.3
  • 26
    • 33846901911 scopus 로고    scopus 로고
    • Continuous bone loss around a tapered uncemented femoral stem: A long-term evaluation with DEXA
    • Boden HS, Skoldenberg OG, Salemyr MO, et al. 2006. Continuous bone loss around a tapered uncemented femoral stem: a long-term evaluation with DEXA. Acta Orthop 77: 877-885.
    • (2006) Acta Orthop , vol.77 , pp. 877-885
    • Boden, H.S.1    Skoldenberg, O.G.2    Salemyr, M.O.3
  • 27
    • 68649089531 scopus 로고    scopus 로고
    • Bone remodeling characteristics of a short-stemmed total hip replacement
    • Chen HH, Morrey BF, An KN, et al. 2009. Bone remodeling characteristics of a short-stemmed total hip replacement. J Arthroplasty 24: 945-950.
    • (2009) J Arthroplasty , vol.24 , pp. 945-950
    • Chen, H.H.1    Morrey, B.F.2    An, K.N.3
  • 28
    • 64949196585 scopus 로고    scopus 로고
    • Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions
    • Fottner A, Schmid M, Birkenmaier C, et al. 2009. Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions. Clin Biomech (Bristol, Avon) 24: 429-434.
    • (2009) Clin Biomech (Bristol, Avon) , vol.24 , pp. 429-434
    • Fottner, A.1    Schmid, M.2    Birkenmaier, C.3
  • 29
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
    • Karrholm J, Borssen B, Lowenhielm G, et al. 1994. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76: 912-917.
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 912-917
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3
  • 30
    • 0038048384 scopus 로고    scopus 로고
    • Finite element analysis of the cervico-trochanteric stemless femoral prosthesis
    • Tai CL, Shih CH, Chen WP, et al. 2003. Finite element analysis of the cervico-trochanteric stemless femoral prosthesis. Clin Biomech (Bristol, Avon) 18: S53-S58.
    • (2003) Clin Biomech (Bristol, Avon) , vol.18
    • Tai, C.L.1    Shih, C.H.2    Chen, W.P.3
  • 31
    • 11244285663 scopus 로고    scopus 로고
    • Bone remodelling of a proximal femur with the thrust plate prosthesis: An in vitro case
    • Taylor WR, Ploeg H, Hertig D, et al. 2004. Bone remodelling of a proximal femur with the thrust plate prosthesis: an in vitro case. Comput Methods Biomech Biomed Engin 7: 131-137.
    • (2004) Comput Methods Biomech Biomed Engin , vol.7 , pp. 131-137
    • Taylor, W.R.1    Ploeg, H.2    Hertig, D.3
  • 32
    • 0034878992 scopus 로고    scopus 로고
    • Femoral remodeling after porous-coated total hip arthroplasty with and without hydroxyapatite-tricalcium phosphate coating: A prospective randomized trial
    • Tanzer M, Kantor S, Rosenthall L, et al. 2001. Femoral remodeling after porous-coated total hip arthroplasty with and without hydroxyapatite-tricalcium phosphate coating: a prospective randomized trial. J Arthroplasty 16: 552-558.
    • (2001) J Arthroplasty , vol.16 , pp. 552-558
    • Tanzer, M.1    Kantor, S.2    Rosenthall, L.3
  • 33
    • 79952799290 scopus 로고    scopus 로고
    • Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: A finite element study
    • Puthumanapully PK, Browne M., 2011. Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: a finite element study. J Orthop Res 29: 787-794.
    • (2011) J Orthop Res , vol.29 , pp. 787-794
    • Puthumanapully, P.K.1    Browne, M.2
  • 34
    • 0036140349 scopus 로고    scopus 로고
    • A contact model with ingrowth control for bone remodelling around cementless stems
    • Fernandes PR, Folgado J, Jacobs C, et al. 2002. A contact model with ingrowth control for bone remodelling around cementless stems. J Biomech 35: 167-176.
    • (2002) J Biomech , vol.35 , pp. 167-176
    • Fernandes, P.R.1    Folgado, J.2    Jacobs, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.