메뉴 건너뛰기




Volumn 40, Issue 10, 2007, Pages 2318-2323

Physiologically based boundary conditions in finite element modelling

Author keywords

Constraints; Femoral loading; Finite element; Physiological boundary conditions

Indexed keywords

BONE; BOUNDARY CONDITIONS; FINITE ELEMENT METHOD; IMPLANTS (SURGICAL); MUSCLE; PHYSIOLOGY;

EID: 34347244882     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2006.10.038     Document Type: Article
Times cited : (171)

References (14)
  • 1
    • 7044238389 scopus 로고    scopus 로고
    • The effect of muscle loading on the simulation of bone remodelling in the proximal femur
    • Bitsakos C., Kerner J., Fisher I., and Amis A.A. The effect of muscle loading on the simulation of bone remodelling in the proximal femur. Journal of Biomechanics 38 (2005) 133-139
    • (2005) Journal of Biomechanics , vol.38 , pp. 133-139
    • Bitsakos, C.1    Kerner, J.2    Fisher, I.3    Amis, A.A.4
  • 3
    • 0019844822 scopus 로고
    • Fatigue behavior of adult cortical bone: the influence of mean strain and strain range
    • Carter D.R., Caler W.E., Spengler D.M., and Frankel V.H. Fatigue behavior of adult cortical bone: the influence of mean strain and strain range. Acta Orthopaedica Scandinavica 52 (1981) 481-490
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , pp. 481-490
    • Carter, D.R.1    Caler, W.E.2    Spengler, D.M.3    Frankel, V.H.4
  • 6
    • 0017250268 scopus 로고
    • Tension studies of human knee ligaments. Yield point, ultimate failure, and disruption of the cruciate and tibial collateral ligaments
    • Kennedy J.C., Hawkins R.J., Willis R.B., and Danylchuck K.D. Tension studies of human knee ligaments. Yield point, ultimate failure, and disruption of the cruciate and tibial collateral ligaments. Journal of Bone and Joint Surgery-American Volume 58 (1976) 350-355
    • (1976) Journal of Bone and Joint Surgery-American Volume , vol.58 , pp. 350-355
    • Kennedy, J.C.1    Hawkins, R.J.2    Willis, R.B.3    Danylchuck, K.D.4
  • 7
    • 0033034569 scopus 로고    scopus 로고
    • Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling
    • Kerner J., Huiskes R., van Lenthe G.H., Weinans H., van Rietbergen B., Engh C.A., and Amis A.A. Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling. Journal of Biomechanics 32 (1999) 695-703
    • (1999) Journal of Biomechanics , vol.32 , pp. 695-703
    • Kerner, J.1    Huiskes, R.2    van Lenthe, G.H.3    Weinans, H.4    van Rietbergen, B.5    Engh, C.A.6    Amis, A.A.7
  • 8
    • 0042388348 scopus 로고    scopus 로고
    • THA loading arising from increased femoral anteversion and offset may lead to critical cement stresses
    • Kleemann R.U., Heller M.O., Stoeckle U., Taylor W.R., and Duda G.N. THA loading arising from increased femoral anteversion and offset may lead to critical cement stresses. Journal of Orthopaedic Research 21 (2003) 767-774
    • (2003) Journal of Orthopaedic Research , vol.21 , pp. 767-774
    • Kleemann, R.U.1    Heller, M.O.2    Stoeckle, U.3    Taylor, W.R.4    Duda, G.N.5
  • 9
    • 0029880089 scopus 로고    scopus 로고
    • Friction and stem stiffness affect dynamic interface motion in total hip replacement
    • Kuiper J.H., and Huiskes R. Friction and stem stiffness affect dynamic interface motion in total hip replacement. Journal of Orthopaedic Research 14 (1996) 36-43
    • (1996) Journal of Orthopaedic Research , vol.14 , pp. 36-43
    • Kuiper, J.H.1    Huiskes, R.2
  • 11
    • 0037667051 scopus 로고    scopus 로고
    • Polgar, K., Gill, H.S., Viceconti, M., Murray, D.W., O'Connor, J.J., 2003. Strain distribution within the human femur due to physiological and simplified loading: finite element analysis using the muscle standardized femur model. Proceedings of the Institute of Mechanical Engineers, vol. H 217, pp. 173-189.
  • 12
    • 34347205002 scopus 로고    scopus 로고
    • Numerical simulations can influence and undermine the reliability of results in THR
    • Zeman M.E., and Cerrolaza M. (Eds), WIT Press, Southampton
    • Simões J.A., and Ramos A. Numerical simulations can influence and undermine the reliability of results in THR. In: Zeman M.E., and Cerrolaza M. (Eds). Computational Modeling of Tissue Surgery (2005), WIT Press, Southampton 131-162
    • (2005) Computational Modeling of Tissue Surgery , pp. 131-162
    • Simões, J.A.1    Ramos, A.2
  • 14
    • 17044401703 scopus 로고    scopus 로고
    • Extracting clinically relevant data from finite element simulations
    • Viceconti M., Olsen S., Nolte L.P., and Burton K. Extracting clinically relevant data from finite element simulations. Clinical Biomechanics 20 (2005) 451-454
    • (2005) Clinical Biomechanics , vol.20 , pp. 451-454
    • Viceconti, M.1    Olsen, S.2    Nolte, L.P.3    Burton, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.