Volumn 103, Issue 4, 2012, Pages 454-462

Development and dosimetry of a small animal lung irradiation platform

Author keywords

dosimetry; lungs rodent; radiation medical; x rays

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; EQUIPMENT; EQUIPMENT DESIGN; INSTRUMENTATION; LUNG; MOUSE; PATHOLOGY; RADIATION EXPOSURE; RADIATION INJURY; RADIATION PNEUMONIA; RADIOMETRY; RAT; WHOLE BODY RADIATION;

EID: 84866050850     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/HP.0b013e3182632526     Document Type: Article
Times cited : (14)

References (26)
  • 2
    • 0020215010 scopus 로고
    • Dose fractionation dose rate and iso-effect relationships for normal tissue responses
    • Barendsen GW. Dose fractionation, dose rate and iso-effect relationships for normal tissue responses. Int J Radiat Oncol Biol Phys 8:1981-1997; 1982.
    • (1982) Int J Radiat Oncol Biol Phys , vol.8 , pp. 1981-1997
    • Barendsen, G.W.1
  • 5
    • 67649604668 scopus 로고    scopus 로고
    • Characteristics of gafchromic xr-rv2 radiochromic film
    • Blair A, Meyer J. Characteristics of gafchromic xr-rv2 radiochromic film. Med Phys 36:3050-3058; 2009.
    • (2009) Med Phys , vol.36 , pp. 3050-3058
    • Blair, A.1    Meyer, J.2
  • 6
    • 79551673399 scopus 로고    scopus 로고
    • Characterization of image quality and imageguidance performance of a preclinical microirradiator
    • Clarkson R, Lindsay PE, Ansell S, Wilson G, Jelveh S, Hill RP, Jaffray DA. Characterization of image quality and imageguidance performance of a preclinical microirradiator. Med Phys 38:845-856; 2011.
    • (2011) Med Phys , vol.38 , pp. 845-856
    • Clarkson, R.1    Lindsay, P.E.2    Ansell, S.3    Wilson, G.4    Jelveh, S.5    Hill, R.P.6    Jaffray, D.A.7
  • 9
    • 44849121666 scopus 로고    scopus 로고
    • Medical countermeasures for radiation combined injury: Radiation with burn blast trauma andor sepsis
    • Report Of An NIAID Workshop March 26 "27, 2007
    • DiCarlo AL, Hatchett RJ, Kaminski JM, Ledney GD, Pellmar TC, Okunieff P, Ramakrishnan N. Medical countermeasures for radiation combined injury: radiation with burn, blast, trauma and/or sepsis. Report of an NIAID workshop, March 26-27, 2007. Radiat Res 169:712-721; 2008.
    • (2008) Radiat Res , vol.169 , pp. 712-721
    • DiCarlo, A.L.1    Hatchett, R.J.2    Kaminski, J.M.3    Ledney, G.D.4    Pellmar, T.C.5    Okunieff, P.6    Ramakrishnan, N.7
  • 10
    • 13644255923 scopus 로고    scopus 로고
    • Application of commercial mosfet detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kv to 250 kv
    • Ehringfeld C, Schmid S, Poljanc K, Kirisits C, Aiginger H, Georg D. Application of commercial mosfet detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kv to 250 kv. Phys Med Biol 50:289-303; 2005.
    • (2005) Phys Med Biol , vol.50 , pp. 289-303
    • Ehringfeld, C.1    Schmid, S.2    Poljanc, K.3    Kirisits, C.4    Aiginger, H.5    Georg, D.6
  • 11
    • 33749392945 scopus 로고    scopus 로고
    • Energy and integrated dose dependence of mosfet dosimeter sensitivity for irradiation energies between 30 kv and 60co
    • Lavallee MC, Gingras L, Beaulieu L. Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kv and 60co. Med Phys 33: 3683-3689; 2006.
    • (2006) Med Phys , vol.33 , pp. 3683-3689
    • Lavallee, M.C.1    Gingras, L.2    Beaulieu, L.3
  • 14
    • 82755163790 scopus 로고    scopus 로고
    • Commissioning a small-field biological irradiator using point, 2d, and 3d dosimetry techniques
    • Newton J, Oldham M, Thomas A, Li Y, Adamovics J, Kirsch DG, Das S. Commissioning a small-field biological irradiator using point, 2d, and 3d dosimetry techniques. Med Phys 38:6754-6762; 2011.
    • (2011) Med Phys , vol.38 , pp. 6754-6762
    • Newton, J.1    Oldham, M.2    Thomas, A.3    Li, Y.4    Adamovics, J.5    Kirsch, D.G.6    Das, S.7
  • 15
    • 82955168421 scopus 로고    scopus 로고
    • Mosfet assessment of radiation dose delivered to mice using the small animal radiation research platform (sarrp)
    • NgwaW, Korideck H, Chin LM, Makrigiorgos GM, Berbeco RI. MOSFET assessment of radiation dose delivered to mice using the small animal radiation research platform (SARRP). Radiat Res 176:816-820; 2011.
    • (2011) Radiat Res , vol.176 , pp. 816-820
    • NgwaW Korideck, H.1    Chin, L.M.2    Makrigiorgos, G.M.3    Berbeco, R.I.4
  • 16
    • 19944401152 scopus 로고    scopus 로고
    • Priority list of research areas for radiological nuclear threat countermeasures
    • Pellmar TC, Rockwell S. Priority list of research areas for radiological nuclear threat countermeasures. Radiat Res 163: 115-123; 2005.
    • (2005) Radiat Res , vol.163 , pp. 115-123
    • Pellmar, T.C.1    Rockwell, S.2
  • 20
    • 33749391308 scopus 로고    scopus 로고
    • Characterization and use of mosfet as in vivo dosimeters under 192ir irradiation for real-time quality assurance
    • Tremblay C, Gingras L, Archambault L, Chretien M, Martin A, Roy R, Beaulieu L. Characterization and use of MOSFET as in vivo dosimeters under 192Ir irradiation for real-time quality assurance. Med Phys 32:2003; 2005.
    • (2005) Med Phys , vol.32 , pp. 2003
    • Tremblay, C.1    Gingras, L.2    Archambault, L.3    Chretien, M.4    Martin, A.5    Roy, R.6    Beaulieu, L.7
  • 24
    • 34247606356 scopus 로고    scopus 로고
    • Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during ct: Comparison with thermoluminescent dosimetry
    • Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Sarder M, Barnes L. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry. AJR Am J Roentgenol 188:1332-1336; 2007.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1332-1336
    • Yoshizumi, T.T.1    Goodman, P.C.2    Frush, D.P.3    Nguyen, G.4    Toncheva, G.5    Sarder, M.6    Barnes, L.7
  • 25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.