-
1
-
-
33644854087
-
The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program
-
Baldwin, J. T., Borovetz, H. S., Duncan, B. W., Gartner, M. J., Jarvik, R. K., Weiss, W. J., and Hoke, T. R. The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program. Circulation, 2006, 113(1), 147-155.
-
(2006)
Circulation
, vol.113
, Issue.1
, pp. 147-155
-
-
Baldwin, J.T.1
Borovetz, H.S.2
Duncan, B.W.3
Gartner, M.J.4
Jarvik, R.K.5
Weiss, W.J.6
Hoke, T.R.7
-
2
-
-
0027379206
-
In vivo evaluation of the Nimbus axial flow ventricular assist system: Criteria and methods
-
Antaki, J. F., Butler, K. C., Kormos, R. L., Kawai, A., Konishi, H., Kerrigan, J. P., Borovetz, H. S., Maher, T. R., Kameneva, M. V., and Griffith, B. P. In vivo evaluation of the Nimbus axial flow ventricular assist system: criteria and methods. ASAIO J., 1993, 39(3), M237-M241.
-
(1993)
ASAIO J
, vol.39
, Issue.3
-
-
Antaki, J.F.1
Butler, K.C.2
Kormos, R.L.3
Kawai, A.4
Konishi, H.5
Kerrigan, J.P.6
Borovetz, H.S.7
Maher, T.R.8
Kameneva, M.V.9
Griffith, B.P.10
-
3
-
-
0033200880
-
Fluid dynamic characterization of operating conditions for continuous flow blood pumps
-
Wu, Z. J., Antaki, J. F., Burgreen, G. W., Butler, K. C., Thomas, D. C., and Griffith, B. P. Fluid dynamic characterization of operating conditions for continuous flow blood pumps. ASAIO J., 1999, 45(5), 442-449.
-
(1999)
ASAIO J
, vol.45
, Issue.5
, pp. 442-449
-
-
Wu, Z.J.1
Antaki, J.F.2
Burgreen, G.W.3
Butler, K.C.4
Thomas, D.C.5
Griffith, B.P.6
-
4
-
-
0037240792
-
Evaluation of hemolysis in the VentrAssist implantable rotary blood pump
-
James, N. L., Wilkinson, C. M., Lingard, N. L., Van der Meer, A. L., and Woodard, J. C. Evaluation of hemolysis in the VentrAssist implantable rotary blood pump. Artif. Organs., 2003, 27(1), 108-113.
-
(2003)
Artif. Organs
, vol.27
, Issue.1
, pp. 108-113
-
-
James, N.L.1
Wilkinson, C.M.2
Lingard, N.L.3
Van der Meer, A.L.4
Woodard, J.C.5
-
5
-
-
0034626117
-
First permanent implant of the Jarvik 2000 heart
-
Westaby, S., Banning, A. P., Jarvik, R., Frazier, O. H., Pigott, D. W., Jin, X. Y., Catarino, P. A., Saito, S., Robson, D., Freeland, A., Myers, T. S., and Poole-Wilson, P. A. First permanent implant of the Jarvik 2000 heart. Lancet., 2000, 356(9233), 900-903.
-
(2000)
Lancet
, vol.356
, Issue.9233
, pp. 900-903
-
-
Westaby, S.1
Banning, A.P.2
Jarvik, R.3
Frazier, O.H.4
Pigott, D.W.5
Jin, X.Y.6
Catarino, P.A.7
Saito, S.8
Robson, D.9
Freeland, A.10
Myers, T.S.11
Poole-Wilson, P.A.12
-
6
-
-
34249099649
-
Early in vivo experience with the pediatric Jarvik 2000 heart
-
Kilic, A., Nolan, T. D. C., Li, T., Yankey, G. K., Prastein, D. J., Cheng, G., Jarvik, R. K., Wu, Z. J., and Griffith, B. P. Early in vivo experience with the pediatric Jarvik 2000 heart. ASAIO J., 2007, 53(3), 374-378.
-
(2007)
ASAIO J
, vol.53
, Issue.3
, pp. 374-378
-
-
Kilic, A.1
Nolan, T.D.C.2
Li, T.3
Yankey, G.K.4
Prastein, D.J.5
Cheng, G.6
Jarvik, R.K.7
Wu, Z.J.8
Griffith, B.P.9
-
7
-
-
26444473548
-
Long-term support of 9 patients with the DeBakey VAD for more than 200 days
-
Wilhelm, M. J., Hammel, D., Schmid, C., Rhode, A., Kaan, T., Rothenburger, M., Stypmann, J., Schäfers, M., Schmidt, C., Baba, H. A., and Scheid, H. H. Long-term support of 9 patients with the DeBakey VAD for more than 200 days. J. Thoracic Cardiovascular Surg., 2005, 130(4), 1122-1129.
-
(2005)
J. Thoracic Cardiovascular Surg
, vol.130
, Issue.4
, pp. 1122-1129
-
-
Wilhelm, M.J.1
Hammel, D.2
Schmid, C.3
Rhode, A.4
Kaan, T.5
Rothenburger, M.6
Stypmann, J.7
Schäfers, M.8
Schmidt, C.9
Baba, H.A.10
Scheid, H.H.11
-
8
-
-
0027297266
-
Minimization of hemolysis in centrifugal blood pumps: Influence of different geometries
-
Schima, H., Müller, M. R., Papantonis, D., Schlusche, C., Huber, I., Schmidt, C., Trubel, W., Thoma, H., Losert, U., and Wolner, E. Minimization of hemolysis in centrifugal blood pumps: influence of different geometries. Int. J Artif. Organs, 1993, 16(7), 521-529.
-
(1993)
Int. J Artif. Organs
, vol.16
, Issue.7
, pp. 521-529
-
-
Schima, H.1
Müller, M.R.2
Papantonis, D.3
Schlusche, C.4
Huber, I.5
Schmidt, C.6
Trubel, W.7
Thoma, H.8
Losert, U.9
Wolner, E.10
-
9
-
-
0028912773
-
A fluid dynamic analysis using flow visualization of the Baylor /NASA implantable axial flow blood pump for design improvement
-
Wernicke, J. T., Meier, D., Mizuguchi, K., Damm, G., Aber, G., Benkowski, R., Nosé, Y., Noon, G. P., and DeBakey, M. E. A fluid dynamic analysis using flow visualization of the Baylor /NASA implantable axial flow blood pump for design improvement. Artif. Organs, 1995, 19(2), 161-177.
-
(1995)
Artif. Organs
, vol.19
, Issue.2
, pp. 161-177
-
-
Wernicke, J.T.1
Meier, D.2
Mizuguchi, K.3
Damm, G.4
Aber, G.5
Benkowski, R.6
Nosé, Y.7
Noon, G.P.8
DeBakey, M.E.9
-
10
-
-
0031898596
-
Flow visualization as a complementary tool to hemolysis testing in the development of centrifugal blood pumps
-
Yamane, T., Asztalos, B., Nishida, M., Masuzawa, T., Takiura, K., Taenaka, Y., Konishi, Y., Miyazoe, Y., and Ito, K. Flow visualization as a complementary tool to hemolysis testing in the development of centrifugal blood pumps. Artif. Organs, 1998, 22(5), 375-380.
-
(1998)
Artif. Organs
, vol.22
, Issue.5
, pp. 375-380
-
-
Yamane, T.1
Asztalos, B.2
Nishida, M.3
Masuzawa, T.4
Takiura, K.5
Taenaka, Y.6
Konishi, Y.7
Miyazoe, Y.8
Ito, K.9
-
11
-
-
0032866184
-
Development of design methods for a centrifugal blood pump with a fluid dynamic approach: Results in hemolysis tests
-
Masuzawa, T., Tsukiya, T., Endo, S., Tatsumi, E., Taenaka, Y., Takano, H., Yamane, T., Nishida, M., Asztalos, B., Miyazoe, Y., Ito, K., Sawairi, T., and Konishi, Y. Development of design methods for a centrifugal blood pump with a fluid dynamic approach: results in hemolysis tests. Artif. Organs, 1999, 23(8), 757-761.
-
(1999)
Artif. Organs
, vol.23
, Issue.8
, pp. 757-761
-
-
Masuzawa, T.1
Tsukiya, T.2
Endo, S.3
Tatsumi, E.4
Taenaka, Y.5
Takano, H.6
Yamane, T.7
Nishida, M.8
Asztalos, B.9
Miyazoe, Y.10
Ito, K.11
Sawairi, T.12
Konishi, Y.13
-
12
-
-
0034282430
-
An investigation of blood flow behavior and hemolysis in artificial organs
-
Yasuda, T., Shimokasa, K., Funakubo, A., Higami, T., Kawamura, T., and Fukui, Y. An investigation of blood flow behavior and hemolysis in artificial organs. ASAIO J., 2000, 46(5), 527-531.
-
(2000)
ASAIO J
, vol.46
, Issue.5
, pp. 527-531
-
-
Yasuda, T.1
Shimokasa, K.2
Funakubo, A.3
Higami, T.4
Kawamura, T.5
Fukui, Y.6
-
13
-
-
0032816330
-
Flow visualization study to improve hemocompatibility of a centrifugal blood pump
-
Nishida, M., Asztalos, B., Yamane, T., Masuzawa, T., Tsukiya, T., Endo, S., Taenaka, Y., Miyazoe, Y., Ito, K., and Konishi, Y. Flow visualization study to improve hemocompatibility of a centrifugal blood pump. Artif. Organs, 1999, 23(8), 697-703.
-
(1999)
Artif. Organs
, vol.23
, Issue.8
, pp. 697-703
-
-
Nishida, M.1
Asztalos, B.2
Yamane, T.3
Masuzawa, T.4
Tsukiya, T.5
Endo, S.6
Taenaka, Y.7
Miyazoe, Y.8
Ito, K.9
Konishi, Y.10
-
14
-
-
0034940556
-
Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device
-
Day, S. W., McDaniel, J. C., Wood, H. G., Allaire, P. E., Landrot, N., and Curtas, A. Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device. ASAIO J., 2001, 47(4), 406-411.
-
(2001)
ASAIO J
, vol.47
, Issue.4
, pp. 406-411
-
-
Day, S.W.1
McDaniel, J.C.2
Wood, H.G.3
Allaire, P.E.4
Landrot, N.5
Curtas, A.6
-
15
-
-
0034041252
-
Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump
-
Anderson, J. B., Wood, H. G., Allaire, P. E., Bearnson, G., and Khanwilkar, P. Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump. Artif. Organs, 2000, 24(5), 377-385.
-
(2000)
Artif. Organs
, vol.24
, Issue.5
, pp. 377-385
-
-
Anderson, J.B.1
Wood, H.G.2
Allaire, P.E.3
Bearnson, G.4
Khanwilkar, P.5
-
16
-
-
2442601403
-
Computational fluid dynamics (CFD) study of the 4th generation prototype of a continuous flow ventricular assist device (VAD)
-
Song, X., Wood, H. G., and Olsen, D. Computational fluid dynamics (CFD) study of the 4th generation prototype of a continuous flow ventricular assist device (VAD). J. Biomech Engng, 2004, 126(2), 180-187.
-
(2004)
J. Biomech Engng
, vol.126
, Issue.2
, pp. 180-187
-
-
Song, X.1
Wood, H.G.2
Olsen, D.3
-
17
-
-
0029085081
-
Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump
-
Bludszuweit, C. Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. Artif. Organs, 1995, 19(7), 590-596.
-
(1995)
Artif. Organs
, vol.19
, Issue.7
, pp. 590-596
-
-
Bludszuweit, C.1
-
18
-
-
0029090222
-
Model for a general mechanical blood damage prediction
-
Bludszuweit, C. Model for a general mechanical blood damage prediction. Artif. Organs, 1995, 19(7), 583-589.
-
(1995)
Artif. Organs
, vol.19
, Issue.7
, pp. 583-589
-
-
Bludszuweit, C.1
-
19
-
-
26444524441
-
Computational design and experimental performance testing of an axial-flow pediatric: Ventricular assist device
-
Throckmorton, A. L., Lim, D. S., McGulloch, M. A., Jiang, W., Song, X., Allaire, P. E., Wood, H. G., and Olsen, D. B. Computational design and experimental performance testing of an axial-flow pediatric: ventricular assist device. ASAIO J., 2005, 51(5), 629-635.
-
(2005)
ASAIO J
, vol.51
, Issue.5
, pp. 629-635
-
-
Throckmorton, A.L.1
Lim, D.S.2
McGulloch, M.A.3
Jiang, W.4
Song, X.5
Allaire, P.E.6
Wood, H.G.7
Olsen, D.B.8
-
20
-
-
33845422135
-
Microscopic investigation of erythrocyte deformation dynamics
-
Zhao, R., Antaki, J. F., Naik, T., Bachman, T. N., Kameneva, M. V., and Wu, Z. J. Microscopic investigation of erythrocyte deformation dynamics. Biorheology, 2006, 43(6), 747-765.
-
(2006)
Biorheology
, vol.43
, Issue.6
, pp. 747-765
-
-
Zhao, R.1
Antaki, J.F.2
Naik, T.3
Bachman, T.N.4
Kameneva, M.V.5
Wu, Z.J.6
-
21
-
-
26444519934
-
Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization
-
Wu, J., Antaki, J. F., Wagner, W. R., Snyder, T. A., Paden, B. E., and Borovetz, H. S. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization. ASAIO J., 2005, 51(5), 636-643.
-
(2005)
ASAIO J
, vol.51
, Issue.5
, pp. 636-643
-
-
Wu, J.1
Antaki, J.F.2
Wagner, W.R.3
Snyder, T.A.4
Paden, B.E.5
Borovetz, H.S.6
-
22
-
-
0025082325
-
Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves
-
Giersiepen, M., Wurzinger, L. J., Opitz, R., and Reul, H. Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves. Int. J. Artif. Organs, 1990, 13(5), 300-306.
-
(1990)
Int. J. Artif. Organs
, vol.13
, Issue.5
, pp. 300-306
-
-
Giersiepen, M.1
Wurzinger, L.J.2
Opitz, R.3
Reul, H.4
|