메뉴 건너뛰기




Volumn 34, Issue 7, 2012, Pages 914-919

Orientation of orthotropic material properties in a femur FE model: A method based on the principal stresses directions

Author keywords

Orthotropic axes orientation; Principal stress; Proximal femur; Subject specific bone FE model; Wolff's law

Indexed keywords

ANATOMICAL STRUCTURES; ANISOTROPIC MATERIAL; FE MODEL; FINITE ELEMENTS; GAIT CYCLES; HETEROGENEOUS MATERIALS; MECHANICAL BEHAVIOR; ORTHOTROPIC BEHAVIOR; ORTHOTROPIC MATERIAL PROPERTIES; ORTHOTROPIC MATERIALS; ORTHOTROPIC PROPERTIES; PHYSIOLOGICAL LOADS; PRINCIPAL STRESS; PROXIMAL FEMUR; STRAIN DISTRIBUTIONS; WOLFF'S LAW;

EID: 84864555436     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2011.10.008     Document Type: Article
Times cited : (49)

References (31)
  • 1
    • 0036140349 scopus 로고    scopus 로고
    • A contact model with ingrowth control for bone remodeling around cementless stems
    • Fernandes P.R., Folgado J., Jacobs C., Pellegrini V. A contact model with ingrowth control for bone remodeling around cementless stems. Journal of Biomechanics 2002, 35(2):167-176.
    • (2002) Journal of Biomechanics , vol.35 , Issue.2 , pp. 167-176
    • Fernandes, P.R.1    Folgado, J.2    Jacobs, C.3    Pellegrini, V.4
  • 2
    • 33947618631 scopus 로고    scopus 로고
    • Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads
    • Little J.P., Taddei F., Viceconti M., Murray D.W., Gill H.S. Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads. Clinical Biomechanics 2007, 22(4):440-448.
    • (2007) Clinical Biomechanics , vol.22 , Issue.4 , pp. 440-448
    • Little, J.P.1    Taddei, F.2    Viceconti, M.3    Murray, D.W.4    Gill, H.S.5
  • 3
    • 38349060664 scopus 로고    scopus 로고
    • Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro
    • Schileo E., Taddei F., Cristofolini L., Viceconti M. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro. Journal of Biomechanics 2008, 41:356-367.
    • (2008) Journal of Biomechanics , vol.41 , pp. 356-367
    • Schileo, E.1    Taddei, F.2    Cristofolini, L.3    Viceconti, M.4
  • 4
    • 34250796220 scopus 로고    scopus 로고
    • The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements
    • Taddei F., Schileo E., Helgason B., Cristofolini L., Viceconti M. The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. Medical Engineering and Physics 2007, 29(9):973-979.
    • (2007) Medical Engineering and Physics , vol.29 , Issue.9 , pp. 973-979
    • Taddei, F.1    Schileo, E.2    Helgason, B.3    Cristofolini, L.4    Viceconti, M.5
  • 5
    • 55549143621 scopus 로고    scopus 로고
    • The effect of the density-modulus relationship selected to apply material properties in a finite element model of long bone
    • Austman R.L., Milner J.S., Holdsworth D.W., Dunning C.E. The effect of the density-modulus relationship selected to apply material properties in a finite element model of long bone. Journal of Biomechanics 2008, 41(15):3171-3176.
    • (2008) Journal of Biomechanics , vol.41 , Issue.15 , pp. 3171-3176
    • Austman, R.L.1    Milner, J.S.2    Holdsworth, D.W.3    Dunning, C.E.4
  • 6
    • 2942724172 scopus 로고    scopus 로고
    • The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity
    • Dong X.N., Guo X.E. The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity. Journal of Biomechanics 2004, 37(8):1281-1287.
    • (2004) Journal of Biomechanics , vol.37 , Issue.8 , pp. 1281-1287
    • Dong, X.N.1    Guo, X.E.2
  • 7
    • 0021213283 scopus 로고
    • A continuous wave technique for the measurement of the elastic properties of cortical bone
    • Ashman R.B., Cowin S.C., Van Buskirk W.C., Rice J.C. A continuous wave technique for the measurement of the elastic properties of cortical bone. Journal of Biomechanics 1984, 17(5):349-361.
    • (1984) Journal of Biomechanics , vol.17 , Issue.5 , pp. 349-361
    • Ashman, R.B.1    Cowin, S.C.2    Van Buskirk, W.C.3    Rice, J.C.4
  • 8
    • 0034308380 scopus 로고    scopus 로고
    • Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur
    • Wirtz D.C., Schiffers N., Pandorf T., Radermacher K., Weichert D., Forst R. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. Journal of Biomechanics 2000, 33(10):1325-1330.
    • (2000) Journal of Biomechanics , vol.33 , Issue.10 , pp. 1325-1330
    • Wirtz, D.C.1    Schiffers, N.2    Pandorf, T.3    Radermacher, K.4    Weichert, D.5    Forst, R.6
  • 9
    • 31744434246 scopus 로고    scopus 로고
    • Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions
    • Peng L., Bai J., Zeng X., Zhou Y. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions. Medical Engineering and Physics 2006, 28(3):227-233.
    • (2006) Medical Engineering and Physics , vol.28 , Issue.3 , pp. 227-233
    • Peng, L.1    Bai, J.2    Zeng, X.3    Zhou, Y.4
  • 12
    • 68449096754 scopus 로고    scopus 로고
    • Biomechanical study of mandible bone supporting a four-implant retained bridge finite element analysis of the influence of bone anisotropy and foodstuff position
    • Bonnet A.S., Postaire M., Lipinski P. Biomechanical study of mandible bone supporting a four-implant retained bridge finite element analysis of the influence of bone anisotropy and foodstuff position. Medical Engineering and Physics 2009, 31(7):806-815.
    • (2009) Medical Engineering and Physics , vol.31 , Issue.7 , pp. 806-815
    • Bonnet, A.S.1    Postaire, M.2    Lipinski, P.3
  • 13
    • 77954033185 scopus 로고    scopus 로고
    • Some factors that affect the comparison between isotropic and orthotropic inhomogeneous finite element material models of femur
    • Yang H., Ma X., Guo T. Some factors that affect the comparison between isotropic and orthotropic inhomogeneous finite element material models of femur. Medical Engineering and Physics 2010, 32(6):553-560.
    • (2010) Medical Engineering and Physics , vol.32 , Issue.6 , pp. 553-560
    • Yang, H.1    Ma, X.2    Guo, T.3
  • 14
    • 33847703730 scopus 로고    scopus 로고
    • Quantifying anisotropy of trabecular bone from gray-level images
    • Tabor Z., Rokita E. Quantifying anisotropy of trabecular bone from gray-level images. Bone 2007, 40(4):966-972.
    • (2007) Bone , vol.40 , Issue.4 , pp. 966-972
    • Tabor, Z.1    Rokita, E.2
  • 15
    • 64749083649 scopus 로고    scopus 로고
    • Inhomogeneous, orthotropic material model for the cortical structure of long bones modeled on the basis of clinical CT or density data
    • Schneider R., Faust G., Hindenlang U., Helwig P. Inhomogeneous, orthotropic material model for the cortical structure of long bones modeled on the basis of clinical CT or density data. Computer Methods in Applied Mechanical Engineering 2009, 198(27-29):2167-2174.
    • (2009) Computer Methods in Applied Mechanical Engineering , vol.198 , Issue.27-29 , pp. 2167-2174
    • Schneider, R.1    Faust, G.2    Hindenlang, U.3    Helwig, P.4
  • 17
    • 50249121160 scopus 로고    scopus 로고
    • Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses
    • Baca V., Horak Z., Mikulenka P., Dzupa V. Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses. Medical Engineering and Physics 2008, 30(7):924-930.
    • (2008) Medical Engineering and Physics , vol.30 , Issue.7 , pp. 924-930
    • Baca, V.1    Horak, Z.2    Mikulenka, P.3    Dzupa, V.4
  • 19
    • 0036137448 scopus 로고    scopus 로고
    • Trabecular bone adaptation with an orthotropic material model
    • Miller Z., Fuchs M., Arcan M. Trabecular bone adaptation with an orthotropic material model. Journal of Biomechanics 2002, 35(2):247-256.
    • (2002) Journal of Biomechanics , vol.35 , Issue.2 , pp. 247-256
    • Miller, Z.1    Fuchs, M.2    Arcan, M.3
  • 20
    • 0036135865 scopus 로고    scopus 로고
    • Anisotropic bone remodeling model based on a continuum damage-repair theory
    • Doblaré M., García J.M. Anisotropic bone remodeling model based on a continuum damage-repair theory. Journal of Biomechanics 2002, 35(1):1-17.
    • (2002) Journal of Biomechanics , vol.35 , Issue.1 , pp. 1-17
    • Doblaré, M.1    García, J.M.2
  • 21
    • 64549103367 scopus 로고    scopus 로고
    • Numerical modeling of bone tissue adaptation - a hierarchical approach for bone apparent density and trabecular structure
    • Coelho P.G., Fernandes P.R., Rodrigues H.C., Cardoso J.B., Guedes J.M. Numerical modeling of bone tissue adaptation - a hierarchical approach for bone apparent density and trabecular structure. Journal of Biomechanics 2009, 42(7):830-837.
    • (2009) Journal of Biomechanics , vol.42 , Issue.7 , pp. 830-837
    • Coelho, P.G.1    Fernandes, P.R.2    Rodrigues, H.C.3    Cardoso, J.B.4    Guedes, J.M.5
  • 22
    • 74449087736 scopus 로고    scopus 로고
    • Simulation of orthotropic microstructure remodeling of cancellous bone
    • Kowalczyk P. Simulation of orthotropic microstructure remodeling of cancellous bone. Journal of Biomechanics 2010, 43(3):563-569.
    • (2010) Journal of Biomechanics , vol.43 , Issue.3 , pp. 563-569
    • Kowalczyk, P.1
  • 23
  • 25
    • 7044238389 scopus 로고    scopus 로고
    • The effect of muscle loading on the simulation of bone remodeling in the proximal femur
    • Bitsakos C., Kerner J., Fisher I., Amis A. The effect of muscle loading on the simulation of bone remodeling in the proximal femur. Journal of Biomechanics 2005, 38(1):133-139.
    • (2005) Journal of Biomechanics , vol.38 , Issue.1 , pp. 133-139
    • Bitsakos, C.1    Kerner, J.2    Fisher, I.3    Amis, A.4
  • 28
    • 0028502932 scopus 로고
    • Predicting the compressive mechanical behavior of bone
    • Keller T.S. Predicting the compressive mechanical behavior of bone. Journal of Biomechanics 1994, 27(9):1159-1168.
    • (1994) Journal of Biomechanics , vol.27 , Issue.9 , pp. 1159-1168
    • Keller, T.S.1
  • 30
    • 67650845097 scopus 로고    scopus 로고
    • Metodología para incorporar propiedades de tejido óseo no isotrópico a un modelo de elementos finitos
    • San Antonio T., Ciaccia M., Müller-Karger C., Casanova E. Metodología para incorporar propiedades de tejido óseo no isotrópico a un modelo de elementos finitos. Boletín técnico IMME 2008, 46(3):29-42.
    • (2008) Boletín técnico IMME , vol.46 , Issue.3 , pp. 29-42
    • San Antonio, T.1    Ciaccia, M.2    Müller-Karger, C.3    Casanova, E.4
  • 31
    • 77953523917 scopus 로고    scopus 로고
    • Predicting the yield of the proximal femur using high-order finite-element analysis with inhomogeneous orthotropic material properties
    • Yosibash Z., Tal D., Trabelsi N. Predicting the yield of the proximal femur using high-order finite-element analysis with inhomogeneous orthotropic material properties. Philosophical Transactions of the Royal Society Series A 2010, 368:2707-2723.
    • (2010) Philosophical Transactions of the Royal Society Series A , vol.368 , pp. 2707-2723
    • Yosibash, Z.1    Tal, D.2    Trabelsi, N.3