1
-
-
84957374439
-
Eine neu elecktrokunstand
-
Reiter R. Eine neu elecktrokunstand. Grenzgebeiter der Medicin 1948, 1:133-135.
-
(1948)
Grenzgebeiter der Medicin
, vol.1
, pp. 133-135
-
-
Reiter, R.1
-
2
-
-
33750521878
-
Control of powered upper limb prstheses
-
Wiley-IEEE, New Jersey, USA, Merletti R, Parker P
-
Parker P, Englehart K, Hudgins B. Control of powered upper limb prstheses. Electromyography: physiology, engineering, and noninvasive applications 2004, 453-475. Wiley-IEEE, New Jersey, USA, Merletti R, Parker P.
-
(2004)
Electromyography: physiology, engineering, and noninvasive applications
, pp. 453-475
-
-
Parker, P.1
Englehart, K.2
Hudgins, B.3
-
4
-
-
78650360525
-
Control of hand prostheses using peripheral information
-
Micera S, Carpaneto J, Raspopovic S. Control of hand prostheses using peripheral information. Biomed Eng, IEEE Rev in 2010, 3:48-68.
-
(2010)
Biomed Eng, IEEE Rev in
, vol.3
, pp. 48-68
-
-
Micera, S.1
Carpaneto, J.2
Raspopovic, S.3
-
5
-
-
0019463654
-
Experience with Swedish multifunctional prosthetic hands controlled by pattern recognition of multiple myoelectric signals
-
Almström C, Herberts P, Körner L. Experience with Swedish multifunctional prosthetic hands controlled by pattern recognition of multiple myoelectric signals. Int Orthopaedics 1981, 5:15-21.
-
(1981)
Int Orthopaedics
, vol.5
, pp. 15-21
-
-
Almström, C.1
Herberts, P.2
Körner, L.3
-
6
-
-
34247366472
-
A comparison of surface and intramuscular myoelectric signal classification
-
Hargrove LJ, Englehart K, Hudgins B. A comparison of surface and intramuscular myoelectric signal classification. IEEE Trans Bio-Med Eng 2007, 54(5):847-853.
-
(2007)
IEEE Trans Bio-Med Eng
, vol.54
, Issue.5
, pp. 847-853
-
-
Hargrove, L.J.1
Englehart, K.2
Hudgins, B.3
-
7
-
-
27644591279
-
A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
-
Navarro X, Krueger TB, Lago N, Micera S, Stieglitz T, Dario P. A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripheral Nervous Syst: JPNS 2005, 10(3):229-258.
-
(2005)
J Peripheral Nervous Syst: JPNS
, vol.10
, Issue.3
, pp. 229-258
-
-
Navarro, X.1
Krueger, T.B.2
Lago, N.3
Micera, S.4
Stieglitz, T.5
Dario, P.6
-
8
-
-
50249084472
-
Neural stimulation and recording electrodes
-
10.1146/annurev.bioeng.10.061807.160518, 18429704
-
Cogan SF. Neural stimulation and recording electrodes. Annu Rev Biomed Eng 2008, 10:275-309. 10.1146/annurev.bioeng.10.061807.160518, 18429704.
-
(2008)
Annu Rev Biomed Eng
, vol.10
, pp. 275-309
-
-
Cogan, S.F.1
-
9
-
-
35648932395
-
Implantable microscale neural interfaces
-
10.1007/s10544-006-9045-z, 17252207
-
Cheung KC. Implantable microscale neural interfaces. Biomed Microdevices 2007, 9(6):923-938. 10.1007/s10544-006-9045-z, 17252207.
-
(2007)
Biomed Microdevices
, vol.9
, Issue.6
, pp. 923-938
-
-
Cheung, K.C.1
-
10
-
-
79960791840
-
Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use
-
Scheme E, Englehart K. Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use. J Rehabilitation Res Dev 2011, 48(6):643.
-
(2011)
J Rehabilitation Res Dev
, vol.48
, Issue.6
, pp. 643
-
-
Scheme, E.1
Englehart, K.2
-
11
-
-
0037731758
-
Comparative Analysis of Microprocessors in Upper Limb Prosthetics
-
Lake C, Miguelez J. Comparative Analysis of Microprocessors in Upper Limb Prosthetics. J Prosthet Orthot 2003, 15(2).
-
(2003)
J Prosthet Orthot
, vol.15
, Issue.2
-
-
Lake, C.1
Miguelez, J.2
-
12
-
-
0345896884
-
Selective activation of the nervous system for motor system neural prostheses
-
CRC Press, Boca Raton, USA, Horia-Nicolai LT, Lakhmi CJ
-
Grill WM. Selective activation of the nervous system for motor system neural prostheses. Intelligent systems and technologies in rehabilitation engineering 2001, CRC Press, Boca Raton, USA, Horia-Nicolai LT, Lakhmi CJ.
-
(2001)
Intelligent systems and technologies in rehabilitation engineering
-
-
Grill, W.M.1
-
13
-
-
14844282710
-
-
John Wiley & Sons, New Jersey, USA
-
Merletti R, Parker P. Electromyography: Physiology, Engineering, and Noninvasive Applications 2004, John Wiley & Sons, New Jersey, USA.
-
(2004)
Electromyography: Physiology, Engineering, and Noninvasive Applications
-
-
Merletti, R.1
Parker, P.2
-
14
-
-
79955629423
-
Biocompatibility of intracortical microelectrodes: current status and future prospects
-
May
-
Marin C, Fernández E. Biocompatibility of intracortical microelectrodes: current status and future prospects. Front Neuroengineering 2010, 3(May):1-6.
-
(2010)
Front Neuroengineering
, vol.3
, pp. 1-6
-
-
Marin, C.1
Fernández, E.2
-
15
-
-
26444445003
-
Response of brain tissue to chronically implanted neural electrodes
-
10.1016/j.jneumeth.2005.08.015, 16198003, Tresco P a
-
Polikov VS, Reichert WM, . Tresco P a Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods 2005, 148:1-18. 10.1016/j.jneumeth.2005.08.015, 16198003, Tresco P a.
-
(2005)
J Neurosci Methods
, vol.148
, pp. 1-18
-
-
Polikov, V.S.1
Reichert, W.M.2
-
17
-
-
0019291425
-
Implantable electrical and mechanical interfaces with nerve and muscle
-
10.1007/BF02363438, 7027837
-
Hoffer J, Loeb G. Implantable electrical and mechanical interfaces with nerve and muscle. Ann Biomed Eng 1980, 8:351-360. 10.1007/BF02363438, 7027837.
-
(1980)
Ann Biomed Eng
, vol.8
, pp. 351-360
-
-
Hoffer, J.1
Loeb, G.2
-
18
-
-
0022590426
-
Recruitment properties of monopolar and bipolar epimysial electrodes
-
10.1007/BF02364648, 3706855
-
Grandjean P, Mortimer J. Recruitment properties of monopolar and bipolar epimysial electrodes. Ann Biomed Eng 1986, 14:53-66. 10.1007/BF02364648, 3706855.
-
(1986)
Ann Biomed Eng
, vol.14
, pp. 53-66
-
-
Grandjean, P.1
Mortimer, J.2
-
19
-
-
33744454924
-
An Implanted Upper Extremity Neuroprosthesis Utilizing Myoelectric Control
-
Arlington, 16-19 Mar.
-
Kilgore K, Peckham P, Montague F, Hart R, Bryden A, Keith M, Hoyen H, Bhadra N. An Implanted Upper Extremity Neuroprosthesis Utilizing Myoelectric Control. Proc 2nd Int IEEE EMBS, Conference on Neural Engineering 2005, Arlington, 16-19 Mar..
-
(2005)
Proc 2nd Int IEEE EMBS, Conference on Neural Engineering
-
-
Kilgore, K.1
Peckham, P.2
Montague, F.3
Hart, R.4
Bryden, A.5
Keith, M.6
Hoyen, H.7
Bhadra, N.8
-
20
-
-
2942673164
-
Performance of Epimysial Stimulating Electrodes in the Lower Extremities of Individuals with Spinal Cord Injury
-
10.1109/TNSRE.2004.827224, 15218941
-
Uhlir JP, Triolo RJ, John A, Davis J, Bieri C. Performance of Epimysial Stimulating Electrodes in the Lower Extremities of Individuals with Spinal Cord Injury. IEEE Trans Neural Syst Rehabil Eng 2004, 12(2):279-287. 10.1109/TNSRE.2004.827224, 15218941.
-
(2004)
IEEE Trans Neural Syst Rehabil Eng
, vol.12
, Issue.2
, pp. 279-287
-
-
Uhlir, J.P.1
Triolo, R.J.2
John, A.3
Davis, J.4
Bieri, C.5
-
21
-
-
0034792999
-
Neuroprostheses for the Upper Extremity
-
10.1002/micr.1049, 11746557
-
Keith M. Neuroprostheses for the Upper Extremity. Microsurgery 2001, 21:256-263. 10.1002/micr.1049, 11746557.
-
(2001)
Microsurgery
, vol.21
, pp. 256-263
-
-
Keith, M.1
-
22
-
-
0347622775
-
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis
-
Kilgore KL, Peckham PH, Keith MW, Montague FW, Hart RL, Gazdik MM, Bryden AM, Snyder S, Stage TG. Durability of implanted electrodes and leads in an upper-limb neuroprosthesis. J Rehabilitation Res Dev 2003, 40(6):457-468.
-
(2003)
J Rehabilitation Res Dev
, vol.40
, Issue.6
, pp. 457-468
-
-
Kilgore, K.L.1
Peckham, P.H.2
Keith, M.W.3
Montague, F.W.4
Hart, R.L.5
Gazdik, M.M.6
Bryden, A.M.7
Snyder, S.8
Stage, T.G.9
-
23
-
-
0034744263
-
BION system for distributed neural prosthetic interfaces
-
10.1016/S1350-4533(01)00011-X, 11344003
-
Loeb GE, Peck R, Moore WH, Hood K. BION system for distributed neural prosthetic interfaces. Med Eng Phys 2001, 23:9-18. 10.1016/S1350-4533(01)00011-X, 11344003.
-
(2001)
Med Eng Phys
, vol.23
, pp. 9-18
-
-
Loeb, G.E.1
Peck, R.2
Moore, W.H.3
Hood, K.4
-
24
-
-
60549108959
-
Implantable Myoelectric Sensors (IMES) for Intramuscular Electromyogram Recording
-
3157946, 19224729
-
Farrell T, Weir R. Implantable Myoelectric Sensors (IMES) for Intramuscular Electromyogram Recording. IEEE Trans Biomed Eng 2009, 56:159-171. 3157946, 19224729.
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, pp. 159-171
-
-
Farrell, T.1
Weir, R.2
-
25
-
-
33846908797
-
Technical Details of the Implantable Myoelectric Sensor (IMES), System for Multifunction Prosthesis Control
-
Weir R, Troyk P, DeMichele G, Kerns D. Technical Details of the Implantable Myoelectric Sensor (IMES), System for Multifunction Prosthesis Control. Conf Proc IEEE Eng Med Biol Soc 2005, 7:7337-7340.
-
(2005)
Conf Proc IEEE Eng Med Biol Soc
, vol.7
, pp. 7337-7340
-
-
Weir, R.1
Troyk, P.2
DeMichele, G.3
Kerns, D.4
-
26
-
-
77955641917
-
Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors
-
Baker JJ, Scheme E, Englehart K, Hutchinson DT, Greger B. Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors. IEEE Trans Neural Syst Rehabil Eng 2010, 18(4):424-432.
-
(2010)
IEEE Trans Neural Syst Rehabil Eng
, vol.18
, Issue.4
, pp. 424-432
-
-
Baker, J.J.1
Scheme, E.2
Englehart, K.3
Hutchinson, D.T.4
Greger, B.5
-
27
-
-
1542377573
-
First Clinical Experience with BION Implants for Therapeutic Electrical Stimulation
-
Salter ACD, Bagg SD, Creasy JL, Romano C, Romano D, Richmond FJ, Loeb GE. First Clinical Experience with BION Implants for Therapeutic Electrical Stimulation. Neuromodulation: Technol Neural Interface 2004, 7:38-47.
-
(2004)
Neuromodulation: Technol Neural Interface
, vol.7
, pp. 38-47
-
-
Salter, A.C.D.1
Bagg, S.D.2
Creasy, J.L.3
Romano, C.4
Romano, D.5
Richmond, F.J.6
Loeb, G.E.7
-
28
-
-
0024116463
-
A Spiral Nerve Cuff Electrode for Peripheral Nerve Stimulation
-
10.1109/10.8670, 3198136
-
Naples G, Mortimer J, Scheiner A, Sweeney J. A Spiral Nerve Cuff Electrode for Peripheral Nerve Stimulation. IEEE Trans Biomed Eng 1988, 35(11):905-916. 10.1109/10.8670, 3198136.
-
(1988)
IEEE Trans Biomed Eng
, vol.35
, Issue.11
, pp. 905-916
-
-
Naples, G.1
Mortimer, J.2
Scheiner, A.3
Sweeney, J.4
-
29
-
-
0032374065
-
Stability of Input-Output Properties of Chronically Implanted Multiple Contact Nerve Cuff Stimulating Electrodes
-
10.1109/86.736150, 9865883
-
Grill W, Mortimer J. Stability of Input-Output Properties of Chronically Implanted Multiple Contact Nerve Cuff Stimulating Electrodes. IEEE Trans Rehabil Eng 1998, 6(4):364-373. 10.1109/86.736150, 9865883.
-
(1998)
IEEE Trans Rehabil Eng
, vol.6
, Issue.4
, pp. 364-373
-
-
Grill, W.1
Mortimer, J.2
-
30
-
-
0032916091
-
Cuff Electrodes for Long-Term Recording of Natural Sensory Information
-
10.1109/51.765194, 10337568
-
Struijk J, Thornsen M, Lorsen J, Sinkjaer T. Cuff Electrodes for Long-Term Recording of Natural Sensory Information. IEEE Eng Med Biol Mag 1999, 18(3):91-99. 10.1109/51.765194, 10337568.
-
(1999)
IEEE Eng Med Biol Mag
, vol.18
, Issue.3
, pp. 91-99
-
-
Struijk, J.1
Thornsen, M.2
Lorsen, J.3
Sinkjaer, T.4
-
31
-
-
0030066135
-
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
-
10.1016/0165-0270(95)00123-9, 8869489
-
Loeb G, Peck R. Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J Neurosci Methods 1996, 64:95-103. 10.1016/0165-0270(95)00123-9, 8869489.
-
(1996)
J Neurosci Methods
, vol.64
, pp. 95-103
-
-
Loeb, G.1
Peck, R.2
-
32
-
-
0021800935
-
Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up
-
Waters R, McNeal D, Faloon W, Clifford B. Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up. J Bone Jt Surg 1985, 67(5):792-793.
-
(1985)
J Bone Jt Surg
, vol.67
, Issue.5
, pp. 792-793
-
-
Waters, R.1
McNeal, D.2
Faloon, W.3
Clifford, B.4
-
33
-
-
80052732296
-
Electrodes and chronic optic nerve stimulation
-
Delbeke J. Electrodes and chronic optic nerve stimulation. Biocybernetics Biomed Eng 2011, 31(3):81-94.
-
(2011)
Biocybernetics Biomed Eng
, vol.31
, Issue.3
, pp. 81-94
-
-
Delbeke, J.1
-
34
-
-
0020031364
-
Long-Term Pain Control by Direct Peripheral-Nerve Stimulation
-
Nashold B, Goldner J, Mullen J, Bright D. Long-Term Pain Control by Direct Peripheral-Nerve Stimulation. J Bone Jt Surg 1982, 64-A:1-10.
-
(1982)
J Bone Jt Surg
, vol.64 A
, pp. 1-10
-
-
Nashold, B.1
Goldner, J.2
Mullen, J.3
Bright, D.4
-
35
-
-
84866182956
-
Treatment Of Obstructive Sleep Apnea With Unilateral Hypoglossal Nerve Stimulation
-
Walsh J, Maddison K, Baker V, Tesfayesus W, Hillman D, Eastwood P. Treatment Of Obstructive Sleep Apnea With Unilateral Hypoglossal Nerve Stimulation. Am J Respir Crit Care Med 2010, 181:A5393.
-
(2010)
Am J Respir Crit Care Med
, vol.181
-
-
Walsh, J.1
Maddison, K.2
Baker, V.3
Tesfayesus, W.4
Hillman, D.5
Eastwood, P.6
-
36
-
-
0030130946
-
Neural signals for command control and feedback in functional neuromuscular stimulation: A review
-
Hoffer J, Stein R, Haugland M, Sinkjaer T, Durfee W, Schwartz A, Loeb G, Kantor C. Neural signals for command control and feedback in functional neuromuscular stimulation: A review. J Rehabil Res Dev 1996, 33(2):145-157.
-
(1996)
J Rehabil Res Dev
, vol.33
, Issue.2
, pp. 145-157
-
-
Hoffer, J.1
Stein, R.2
Haugland, M.3
Sinkjaer, T.4
Durfee, W.5
Schwartz, A.6
Loeb, G.7
Kantor, C.8
-
37
-
-
0030739613
-
Spiral nerve cuff electrode for recordings of respiratory output
-
Sahin M, Haxhiu M, Durand D, Dreshaj I. Spiral nerve cuff electrode for recordings of respiratory output. J Appl Physiol 1997, 83:317-322.
-
(1997)
J Appl Physiol
, vol.83
, pp. 317-322
-
-
Sahin, M.1
Haxhiu, M.2
Durand, D.3
Dreshaj, I.4
-
38
-
-
0028386171
-
Skin Contact Force Information in Sensory Nerve Signals Recorded by Implanted Cuff Electrodes
-
Haugland M, Hoffer J, Sinkjaer T. Skin Contact Force Information in Sensory Nerve Signals Recorded by Implanted Cuff Electrodes. IEEE Trans Rehabil Eng 1994, 2:18-28.
-
(1994)
IEEE Trans Rehabil Eng
, vol.2
, pp. 18-28
-
-
Haugland, M.1
Hoffer, J.2
Sinkjaer, T.3
-
39
-
-
42949129200
-
Effects of consecutive slips in nerve signals recorded by implanted cuff electrode
-
10.1016/j.medengphy.2007.05.007, 17600750
-
Tong K, Ronga W, Li L, Cao J. Effects of consecutive slips in nerve signals recorded by implanted cuff electrode. Med Eng Phys 2008, 30:460-465. 10.1016/j.medengphy.2007.05.007, 17600750.
-
(2008)
Med Eng Phys
, vol.30
, pp. 460-465
-
-
Tong, K.1
Ronga, W.2
Li, L.3
Cao, J.4
-
40
-
-
0033016663
-
Control of FES thumb Force Using Slip Information Obtained from the Cutaneous Electroneurogram in Quadriplegic Man
-
10.1109/86.769412, 10391592
-
Haugland M, Lickel A, Haase J, Sinkjaer T. Control of FES thumb Force Using Slip Information Obtained from the Cutaneous Electroneurogram in Quadriplegic Man. IEEE Trans Rehabil Eng 1999, 7(2):215-227. 10.1109/86.769412, 10391592.
-
(1999)
IEEE Trans Rehabil Eng
, vol.7
, Issue.2
, pp. 215-227
-
-
Haugland, M.1
Lickel, A.2
Haase, J.3
Sinkjaer, T.4
-
41
-
-
0029510632
-
Cutaneous Whole Nerve Recordings Used for Correction of Footdrop in Hemiplegic Man
-
Haugland M, Sinkjaer T. Cutaneous Whole Nerve Recordings Used for Correction of Footdrop in Hemiplegic Man. IEEE Trans Rehabil Eng 1995, 3(4):307-317.
-
(1995)
IEEE Trans Rehabil Eng
, vol.3
, Issue.4
, pp. 307-317
-
-
Haugland, M.1
Sinkjaer, T.2
-
42
-
-
0028365834
-
Natural neural sensing and artificial muscle control in man
-
Haugland M
-
Sinkjæ R, Haase J, . Haugland M Natural neural sensing and artificial muscle control in man. Exp Brain Res 1994, 98(3):542-545. Haugland M.
-
(1994)
Exp Brain Res
, vol.98
, Issue.3
, pp. 542-545
-
-
Sinkjæ, R.1
Haase, J.2
-
43
-
-
77951210257
-
On the identification of sensory information from mixed nerves by using single-channel cuff electrodes
-
Raspopovic S, Carpaneto J, Udina E, Navarro X, Micera S. On the identification of sensory information from mixed nerves by using single-channel cuff electrodes. J Neuroengineering Rehabil 2010, 7:17.
-
(2010)
J Neuroengineering Rehabil
, vol.7
, pp. 17
-
-
Raspopovic, S.1
Carpaneto, J.2
Udina, E.3
Navarro, X.4
Micera, S.5
-
44
-
-
0025453330
-
A Nerve Cuff Technique for Selective Excitation of Peripheral Nerve Trunk Regions
-
Sweeney J, Ksienski D, Mortimer J. A Nerve Cuff Technique for Selective Excitation of Peripheral Nerve Trunk Regions. J Appl Physiol 1990, 37(7):706-715.
-
(1990)
J Appl Physiol
, vol.37
, Issue.7
, pp. 706-715
-
-
Sweeney, J.1
Ksienski, D.2
Mortimer, J.3
-
45
-
-
0024637198
-
Recruitment Data for Nerve Cuff Electrodes: Implications for Design of Implantable Stimulators
-
10.1109/10.19851, 2921067
-
McNeal D, Baker L, Symons J. Recruitment Data for Nerve Cuff Electrodes: Implications for Design of Implantable Stimulators. IEEE Trans Biomed Eng 1989, 36(3):301-308. 10.1109/10.19851, 2921067.
-
(1989)
IEEE Trans Biomed Eng
, vol.36
, Issue.3
, pp. 301-308
-
-
McNeal, D.1
Baker, L.2
Symons, J.3
-
46
-
-
0016766025
-
Principles underlying new methods for chronic neural recording
-
Stein R, Charles D, Davis L, Jhamandas J, Mannard A, Nichols T. Principles underlying new methods for chronic neural recording. Can J Neurol Sci 1975, 2(3):235-244.
-
(1975)
Can J Neurol Sci
, vol.2
, Issue.3
, pp. 235-244
-
-
Stein, R.1
Charles, D.2
Davis, L.3
Jhamandas, J.4
Mannard, A.5
Nichols, T.6
-
47
-
-
0034283149
-
An Improved Configuration for the Reduction of EMG in Electrode Cuff Recordings: A Theoretical Approach
-
10.1109/10.867963, 11008430
-
Rahal M, Winter J, Taylor J, Donaldson N. An Improved Configuration for the Reduction of EMG in Electrode Cuff Recordings: A Theoretical Approach. IEEE Trans Biomed Eng 2000, 47(9):1281-1284. 10.1109/10.867963, 11008430.
-
(2000)
IEEE Trans Biomed Eng
, vol.47
, Issue.9
, pp. 1281-1284
-
-
Rahal, M.1
Winter, J.2
Taylor, J.3
Donaldson, N.4
-
48
-
-
0031659840
-
Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: a stereological study of myelinated and unmyelinated axons
-
10.1007/s004010050907, 9797001
-
Larsen JO, Thomsen M, Haugland M, Sinkjær T. Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: a stereological study of myelinated and unmyelinated axons. Acta Neuropathologica 1998, 96(4):365-378. 10.1007/s004010050907, 9797001.
-
(1998)
Acta Neuropathologica
, vol.96
, Issue.4
, pp. 365-378
-
-
Larsen, J.O.1
Thomsen, M.2
Haugland, M.3
Sinkjær, T.4
-
49
-
-
0035850967
-
Effects of chronic nerve cuff and intramuscular electrodes on rat triceps surae motor units
-
Carp J, Chen X, Sheikh H, Wolpaw J. Effects of chronic nerve cuff and intramuscular electrodes on rat triceps surae motor units. Neuroscience Letters 2001, 312(2001):1-4.
-
(2001)
Neuroscience Letters
, vol.312
, Issue.2001
, pp. 1-4
-
-
Carp, J.1
Chen, X.2
Sheikh, H.3
Wolpaw, J.4
-
50
-
-
0035154578
-
Neural morphological effects of long-term implantation of the self-sizing spiral cuff nerve electrode
-
10.1007/BF02345271, 11214279
-
Romero E, Denef J, Delbeke J, Robert A, Veraart C. Neural morphological effects of long-term implantation of the self-sizing spiral cuff nerve electrode. Med Biol Eng Comput 2001, 39:90-100. 10.1007/BF02345271, 11214279.
-
(2001)
Med Biol Eng Comput
, vol.39
, pp. 90-100
-
-
Romero, E.1
Denef, J.2
Delbeke, J.3
Robert, A.4
Veraart, C.5
-
51
-
-
0029325943
-
Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prostheses
-
Mortimer T, Agnew W, Horch K. Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prostheses. IEEE Trans Rehabil Eng 1995, 3(2):145-154.
-
(1995)
IEEE Trans Rehabil Eng
, vol.3
, Issue.2
, pp. 145-154
-
-
Mortimer, T.1
Agnew, W.2
Horch, K.3
-
52
-
-
0032583236
-
Visual sensations produced by optic nerve stimulation using an implanted self-sizing spiral cuff electrode
-
10.1016/S0006-8993(98)00977-9, 9824694
-
Veraart C, Raftopoulos C, Mortimer JT, Delbeke J, Pins D, Michaux G, Vanlierde A, Parrini S, Wanet-Defalque MC. Visual sensations produced by optic nerve stimulation using an implanted self-sizing spiral cuff electrode. Brain Res 1998, 813:181-186. 10.1016/S0006-8993(98)00977-9, 9824694.
-
(1998)
Brain Res
, vol.813
, pp. 181-186
-
-
Veraart, C.1
Raftopoulos, C.2
Mortimer, J.T.3
Delbeke, J.4
Pins, D.5
Michaux, G.6
Vanlierde, A.7
Parrini, S.8
Wanet-Defalque, M.C.9
-
53
-
-
1642277187
-
Biocompatibility of planitium-metallized silicone rubber: in vivo and in vitro evaluation
-
Romero E, Denef J, Delbeke J, Robert A, Veraart C. Biocompatibility of planitium-metallized silicone rubber: in vivo and in vitro evaluation. J Biomater Sci Polymer Edn 2004, 15(2):173-188.
-
(2004)
J Biomater Sci Polymer Edn
, vol.15
, Issue.2
, pp. 173-188
-
-
Romero, E.1
Denef, J.2
Delbeke, J.3
Robert, A.4
Veraart, C.5
-
54
-
-
0032256015
-
New nerve cuff electrode based on a shape memory alloy armature
-
Crampon MA, Sawan M, Brailovski V, Trochu F. New nerve cuff electrode based on a shape memory alloy armature. Proc 20th Int Conf IEEE EMBS 1998, 20(5):2556-2559.
-
(1998)
Proc 20th Int Conf IEEE EMBS
, vol.20
, Issue.5
, pp. 2556-2559
-
-
Crampon, M.A.1
Sawan, M.2
Brailovski, V.3
Trochu, F.4
-
55
-
-
84942596405
-
Designing and fabricating micro-pressure sensors for spiral cuff electrodes
-
, Capri Island, 20-22 Mar.
-
Lin C, Ju M, Soung B, Tseng C. Designing and fabricating micro-pressure sensors for spiral cuff electrodes. 2003, 197-199. , Capri Island, 20-22 Mar..
-
(2003)
, pp. 197-199
-
-
Lin, C.1
Ju, M.2
Soung, B.3
Tseng, C.4
-
56
-
-
0141509902
-
Artefact Reduction With Alternative Cuff Configurations
-
10.1109/TBME.2003.817633, 14560769
-
Andreasen L, Struijk JJ. Artefact Reduction With Alternative Cuff Configurations. IEEE Trans Biomed Eng 2003, 50(10):1160-1166. 10.1109/TBME.2003.817633, 14560769.
-
(2003)
IEEE Trans Biomed Eng
, vol.50
, Issue.10
, pp. 1160-1166
-
-
Andreasen, L.1
Struijk, J.J.2
-
57
-
-
0002797562
-
Techniques to study spinal cord peripheral nerve, and muscle activity in freely moving animmals
-
Hoffer J. Techniques to study spinal cord peripheral nerve, and muscle activity in freely moving animmals. Neurometh 1990, 15:65-145.
-
(1990)
Neurometh
, vol.15
, pp. 65-145
-
-
Hoffer, J.1
-
58
-
-
0036994474
-
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
-
Tyler D, Durand D. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. Neural Syst Rehabilitation Eng, IEEE Trans on 2002, 10(4):294-303.
-
(2002)
Neural Syst Rehabilitation Eng, IEEE Trans on
, vol.10
, Issue.4
, pp. 294-303
-
-
Tyler, D.1
Durand, D.2
-
59
-
-
23844501514
-
Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode
-
Yoo PB, Durand DM. Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Bio-Med Eng 2005, 52(8):1461-9.
-
(2005)
IEEE Trans Bio-Med Eng
, vol.52
, Issue.8
, pp. 1461-1469
-
-
Yoo, P.B.1
Durand, D.M.2
-
60
-
-
77950969109
-
Motion control of the rabbit ankle joint using a flat interface nerve electrode
-
IEEE, Minniapolis
-
Park H, Durand DM. Motion control of the rabbit ankle joint using a flat interface nerve electrode. Conf Proc IEEE Eng Med Biol Soc 2009, 6789-92. IEEE, Minniapolis.
-
(2009)
Conf Proc IEEE Eng Med Biol Soc
, pp. 6789-6792
-
-
Park, H.1
Durand, D.M.2
-
61
-
-
77949890676
-
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
-
10.1088/1741-2560/7/2/026006, 2915830, 20208125
-
Schiefer M, Polasek KH, Triolo RJ, Pinault GCJ, Tyler DJ. Selective stimulation of the human femoral nerve with a flat interface nerve electrode. J Neural Eng 2010, 7(2):26006. 10.1088/1741-2560/7/2/026006, 2915830, 20208125.
-
(2010)
J Neural Eng
, vol.7
, Issue.2
, pp. 26006
-
-
Schiefer, M.1
Polasek, K.H.2
Triolo, R.J.3
Pinault, G.C.J.4
Tyler, D.J.5
-
62
-
-
29644439037
-
Direct Neural Sensory Feedback and Control of a Prosthetic Arm
-
10.1109/TNSRE.2005.856072, 16425828
-
Dhillon G, Horch K. Direct Neural Sensory Feedback and Control of a Prosthetic Arm. IEEE Trans Neural Syst Rehabil Eng 2005, 13(4):468-472. 10.1109/TNSRE.2005.856072, 16425828.
-
(2005)
IEEE Trans Neural Syst Rehabil Eng
, vol.13
, Issue.4
, pp. 468-472
-
-
Dhillon, G.1
Horch, K.2
-
63
-
-
80054062765
-
Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
-
Horch K, Meek S, Taylor TG, Hutchinson DT. Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans Neural Syst Rehabil Eng 2011, 19(5):483-489.
-
(2011)
IEEE Trans Neural Syst Rehabil Eng
, vol.19
, Issue.5
, pp. 483-489
-
-
Horch, K.1
Meek, S.2
Taylor, T.G.3
Hutchinson, D.T.4
-
64
-
-
0036381714
-
Long-Term Biocompatibility of Implanted Polymer-Based Intrafascicular Electrodes
-
Lawrence SM, Larsen JO, Horch KW, Riso R, Sinkjaer T. Long-Term Biocompatibility of Implanted Polymer-Based Intrafascicular Electrodes. J Biomed Mater Res (Appl Biomater) 2002, 63:501-506.
-
(2002)
J Biomed Mater Res (Appl Biomater)
, vol.63
, pp. 501-506
-
-
Lawrence, S.M.1
Larsen, J.O.2
Horch, K.W.3
Riso, R.4
Sinkjaer, T.5
-
65
-
-
0026229639
-
Information Contained in Sensory Nerve Recordings Made with Intrafascicular Electrodes
-
10.1109/10.83604, 1743732
-
Lawrence SM, Larsen JO, Horch KW, Riso R, Sinkjaer T. Information Contained in Sensory Nerve Recordings Made with Intrafascicular Electrodes. IEEE Trans Biomed Eng 1991, 38(9):846-850. 10.1109/10.83604, 1743732.
-
(1991)
IEEE Trans Biomed Eng
, vol.38
, Issue.9
, pp. 846-850
-
-
Lawrence, S.M.1
Larsen, J.O.2
Horch, K.W.3
Riso, R.4
Sinkjaer, T.5
-
66
-
-
74049112343
-
An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves
-
Bossi S, Kammer S, Dorge T, Menciassi A, Hoffmann K, Micera S. An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves. IEEE Trans Biomed Eng 2009, 56(11):2701-2706.
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, Issue.11
, pp. 2701-2706
-
-
Bossi, S.1
Kammer, S.2
Dorge, T.3
Menciassi, A.4
Hoffmann, K.5
Micera, S.6
-
67
-
-
0345603127
-
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
-
10.1016/S0165-0270(03)00231-0, 14659819
-
Lawrence S, Dhillon GS, Horch KW. Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode. J Neurosci Methods 2003, 131(1-2):9-26. 10.1016/S0165-0270(03)00231-0, 14659819.
-
(2003)
J Neurosci Methods
, vol.131
, Issue.1-2
, pp. 9-26
-
-
Lawrence, S.1
Dhillon, G.S.2
Horch, K.W.3
-
68
-
-
84055161627
-
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
-
10.1016/j.bios.2010.05.010, 20627510
-
Boretius T, Badia J, Pascual-Font A, Schuettler M, Navarro X, Yoshida K, Stieglitz T. A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. Biosens Bioelectron 2010, 26:62-69. 10.1016/j.bios.2010.05.010, 20627510.
-
(2010)
Biosens Bioelectron
, vol.26
, pp. 62-69
-
-
Boretius, T.1
Badia, J.2
Pascual-Font, A.3
Schuettler, M.4
Navarro, X.5
Yoshida, K.6
Stieglitz, T.7
-
69
-
-
84055184950
-
Activities on PNS Neural Interfaces for the Control of Hand Prostheses
-
IEEE, Boston
-
Carpaneto J, Cutrone A, Bossi S, Sergi P, Citi L, Rigosa J, Rossini PM, Micera S. Activities on PNS Neural Interfaces for the Control of Hand Prostheses. Conf Proc IEEE Eng Med Biol Soc 2011, 4637-4640. IEEE, Boston.
-
(2011)
Conf Proc IEEE Eng Med Biol Soc
, pp. 4637-4640
-
-
Carpaneto, J.1
Cutrone, A.2
Bossi, S.3
Sergi, P.4
Citi, L.5
Rigosa, J.6
Rossini, P.M.7
Micera, S.8
-
70
-
-
77949422852
-
Double nerve intraneural interface implant on a human amputee for robotic hand control
-
Rossini PM, Micera S, Benvenuto A, Carpaneto J, Cavallo G, Citi L, Cipriani C, Denaro L, Denaro V, Di Pino G, Ferreri F, Guglielmelli E, Hoffmann KP, Raspopovic S, Rigosa J, Rossini L, Tombini M, Dario P. Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiology: Official J Int Federation Clin Neurophysiology 2010, 121(5):777-783.
-
(2010)
Clin Neurophysiology: Official J Int Federation Clin Neurophysiology
, vol.121
, Issue.5
, pp. 777-783
-
-
Rossini, P.M.1
Micera, S.2
Benvenuto, A.3
Carpaneto, J.4
Cavallo, G.5
Citi, L.6
Cipriani, C.7
Denaro, L.8
Denaro, V.9
Di Pino, G.10
Ferreri, F.11
Guglielmelli, E.12
Hoffmann, K.P.13
Raspopovic, S.14
Rigosa, J.15
Rossini, L.16
Tombini, M.17
Dario, P.18
-
71
-
-
77949424269
-
Decoding information from neural signals recorded using intraneural electrodes: toward the development of a neurocontrolled hand prosthesis
-
Micera BS, Ieee SM, Citi L, Rigosa J, Carpaneto J, Raspopovic S, Pino GD, Rossini L, Ieee M, Yoshida K, Denaro L, Dario P, Ieee F, Rossini PM. Decoding information from neural signals recorded using intraneural electrodes: toward the development of a neurocontrolled hand prosthesis. Proc IEEE 2010, 98(3):407-417.
-
(2010)
Proc IEEE
, vol.98
, Issue.3
, pp. 407-417
-
-
Micera, B.S.1
Ieee, S.M.2
Citi, L.3
Rigosa, J.4
Carpaneto, J.5
Raspopovic, S.6
Pino, G.D.7
Rossini, L.8
Ieee, M.9
Yoshida, K.10
Denaro, L.11
Dario, P.12
Ieee, F.13
Rossini, P.M.14
-
72
-
-
19944394548
-
Invasive neural prosthesis for neural signal detection and nerve stimulation
-
Gassonn M, Hutt B, Goodhew I, Kyberd P, Warwick K. Invasive neural prosthesis for neural signal detection and nerve stimulation. Int J Adapt Control Signal Process 2005, 19:365-375.
-
(2005)
Int J Adapt Control Signal Process
, vol.19
, pp. 365-375
-
-
Gassonn, M.1
Hutt, B.2
Goodhew, I.3
Kyberd, P.4
Warwick, K.5
-
73
-
-
33846917981
-
Control of Skeletal Muscle Force with Currents Injected Via an Intrafascicular, Microelectrode Array
-
Normann R, McDonnall D, Clark G. Control of Skeletal Muscle Force with Currents Injected Via an Intrafascicular, Microelectrode Array. Conf Proc IEEE Eng Med Biol Soc, Shanghai 2005, 7:7644-7647.
-
(2005)
Conf Proc IEEE Eng Med Biol Soc, Shanghai
, vol.7
, pp. 7644-7647
-
-
Normann, R.1
McDonnall, D.2
Clark, G.3
-
74
-
-
79960798061
-
Long term in vitro functional stability and recording longevity of fully integrated wireless neural interfaces based on the Utah Slant Electrode Array
-
Sharma A, Rieth L, Tathireddy P, Harrison R, Oppermann H, Klein M, Töpper M, Jung E, Normann R, Clark G, Solzbacher F. Long term in vitro functional stability and recording longevity of fully integrated wireless neural interfaces based on the Utah Slant Electrode Array. J Neural Eng 2011, 8(4):1-6.
-
(2011)
J Neural Eng
, vol.8
, Issue.4
, pp. 1-6
-
-
Sharma, A.1
Rieth, L.2
Tathireddy, P.3
Harrison, R.4
Oppermann, H.5
Klein, M.6
Töpper, M.7
Jung, E.8
Normann, R.9
Clark, G.10
Solzbacher, F.11
-
75
-
-
79958698885
-
Multiple-input single-output closed-loop isometric force control using asynchronous intrafascicular multi-electrode stimulation
-
Frankel M, Dowden BR, Mathews VJ, Normann R, Clark G, Meek SG. Multiple-input single-output closed-loop isometric force control using asynchronous intrafascicular multi-electrode stimulation. IEEE Trans Neural Syst Rehabil Eng 2011, 19(3):325-332.
-
(2011)
IEEE Trans Neural Syst Rehabil Eng
, vol.19
, Issue.3
, pp. 325-332
-
-
Frankel, M.1
Dowden, B.R.2
Mathews, V.J.3
Normann, R.4
Clark, G.5
Meek, S.G.6
-
76
-
-
84055178939
-
Detection and Classification of Multiple Finger Movements Using a Chronically Implanted Utah Electrode Array
-
IEEE, Boston
-
Egan J, Baker J, House P, Greger B. Detection and Classification of Multiple Finger Movements Using a Chronically Implanted Utah Electrode Array. Conf Proc IEEE Eng Med Biol Soc 2011, 7320-7323. IEEE, Boston.
-
(2011)
Conf Proc IEEE Eng Med Biol Soc
, pp. 7320-7323
-
-
Egan, J.1
Baker, J.2
House, P.3
Greger, B.4
-
77
-
-
84861045873
-
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
-
10.1038/nature10987, 22522928
-
Ethier C, Oby ER, Bauman MJ, Miller LE. Restoration of grasp following paralysis through brain-controlled stimulation of muscles. Nature 2012, 485:368-371. 10.1038/nature10987, 22522928.
-
(2012)
Nature
, vol.485
, pp. 368-371
-
-
Ethier, C.1
Oby, E.R.2
Bauman, M.J.3
Miller, L.E.4
-
78
-
-
33746160271
-
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
-
10.1038/nature04970, 16838014
-
Hochberg LR, Serruya MD, Friehs GM, Mukand J, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 2006, 442(7099):164-171. 10.1038/nature04970, 16838014.
-
(2006)
Nature
, vol.442
, Issue.7099
, pp. 164-171
-
-
Hochberg, L.R.1
Serruya, M.D.2
Friehs, G.M.3
Mukand, J.4
Saleh, M.5
Caplan, A.H.6
Branner, A.7
Chen, D.8
Penn, R.D.9
Donoghue, J.P.10
-
79
-
-
79954552027
-
Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array
-
10.1088/1741-2560/8/2/025027, 21436513
-
Simeral JD, Kim SP, Black MJ, Donoghue JP, Hochberg LR. Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array. J Neural Eng 2011, 8(2):025027. 10.1088/1741-2560/8/2/025027, 21436513.
-
(2011)
J Neural Eng
, vol.8
, Issue.2
, pp. 025027
-
-
Simeral, J.D.1
Kim, S.P.2
Black, M.J.3
Donoghue, J.P.4
Hochberg, L.R.5
-
80
-
-
84859135990
-
Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
-
10.1088/1741-2560/9/2/026028, 22442134
-
Prasad A, Sanchez JC. Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing. J Neural Eng 2012, 9(2):026028. 10.1088/1741-2560/9/2/026028, 22442134.
-
(2012)
J Neural Eng
, vol.9
, Issue.2
, pp. 026028
-
-
Prasad, A.1
Sanchez, J.C.2
-
81
-
-
79959536375
-
Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex
-
10.1088/1741-2560/8/4/045005, 21775782
-
Chestek C, Gilja V, Nuyujukian P, Foster JD, Fan JM, Kaufman MT, Churchland MM, Rivera-Alvidrez Z, Cunningham JP, Ryu SI, Shenoy KV. Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex. J Neural Eng 2011, 8(4):045005. 10.1088/1741-2560/8/4/045005, 21775782.
-
(2011)
J Neural Eng
, vol.8
, Issue.4
, pp. 045005
-
-
Chestek, C.1
Gilja, V.2
Nuyujukian, P.3
Foster, J.D.4
Fan, J.M.5
Kaufman, M.T.6
Churchland, M.M.7
Rivera-Alvidrez, Z.8
Cunningham, J.P.9
Ryu, S.I.10
Shenoy, K.V.11
-
82
-
-
84952654013
-
Geometric design and surface morfology of sieve electrodes, Nerve regeneration and biokompatibility studies
-
, Lyon
-
Wallman L, Rosengren A, Danielsen N, Laurell T. Geometric design and surface morfology of sieve electrodes, Nerve regeneration and biokompatibility studies. 2000, 526-530. , Lyon.
-
(2000)
, pp. 526-530
-
-
Wallman, L.1
Rosengren, A.2
Danielsen, N.3
Laurell, T.4
-
83
-
-
48349101795
-
Nerve Signal Monitoring Using an Implantable Microelectrode
-
, Atlanta, 28-31 Oct.
-
Kim YH, Kim YJ, Ami KM, Lee C. Nerve Signal Monitoring Using an Implantable Microelectrode. 2007, 1140-1143. , Atlanta, 28-31 Oct..
-
(2007)
, pp. 1140-1143
-
-
Kim, Y.H.1
Kim, Y.J.2
Ami, K.M.3
Lee, C.4
-
84
-
-
45149133424
-
Neural Prostheses: Electrophysiological and Histological Evaluation of Central Nervous System Alterations Due to Long-Term Implants of Sieve Electrodes to Peripheral Nerves in Cats
-
Panetsos F, Avendano C, Negredo P, Castro J, Bonacasa V. Neural Prostheses: Electrophysiological and Histological Evaluation of Central Nervous System Alterations Due to Long-Term Implants of Sieve Electrodes to Peripheral Nerves in Cats. IEEE Trans Neural Syst Rehabil Eng 2008, 16(3):223-232.
-
(2008)
IEEE Trans Neural Syst Rehabil Eng
, vol.16
, Issue.3
, pp. 223-232
-
-
Panetsos, F.1
Avendano, C.2
Negredo, P.3
Castro, J.4
Bonacasa, V.5
-
85
-
-
11144291416
-
A sieve electrode as a potential autonomic neural interface for bionic medicine
-
Kawada T, Zheng C, Tanabe S, Uemura T, Sunagawa K, Sugimachi M. A sieve electrode as a potential autonomic neural interface for bionic medicine. Proc 26th Int Conf IEEE EMBS 2004, 2:4318-4321.
-
(2004)
Proc 26th Int Conf IEEE EMBS
, vol.2
, pp. 4318-4321
-
-
Kawada, T.1
Zheng, C.2
Tanabe, S.3
Uemura, T.4
Sunagawa, K.5
Sugimachi, M.6
-
86
-
-
33845577142
-
Regenerative electrodes for interfacing injured peripheral nerves : neurobiological assessment
-
, Pisa
-
Lago N, Udina E, Navarro X. Regenerative electrodes for interfacing injured peripheral nerves : neurobiological assessment. Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on 2006, 1149-1153. , Pisa.
-
(2006)
Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on
, pp. 1149-1153
-
-
Lago, N.1
Udina, E.2
Navarro, X.3
-
87
-
-
84857870473
-
High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation
-
Minev IR, Chew DJ, Delivopoulos E, Fawcett JW, Lacour SP. High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation. J Neural Eng 2012, 9(2):1-7.
-
(2012)
J Neural Eng
, vol.9
, Issue.2
, pp. 1-7
-
-
Minev, I.R.1
Chew, D.J.2
Delivopoulos, E.3
Fawcett, J.W.4
Lacour, S.P.5
-
88
-
-
79958282827
-
Engineering and development of a stable, low-impedance, bioelectrical peripheral nerve interface
-
Egeland B, Urbanchek M, Martin D, Kipke D, Jr WK, Cederna P. Engineering and development of a stable, low-impedance, bioelectrical peripheral nerve interface. J Am Coll Surg 2009, 209(3).
-
(2009)
J Am Coll Surg
, vol.209
, Issue.3
-
-
Egeland, B.1
Urbanchek, M.2
Martin, D.3
Kipke, D.4
Jr, W.K.5
Cederna, P.6
-
89
-
-
81955164189
-
Electrochemical activation and inhibition of neuromuscular systems through modulation of ion concentrations with ion-selective membranes
-
Song YA, Melik R, Rabie AN, Ibrahim AMS, Moses D, Tan A, Han J, Lin SJ. Electrochemical activation and inhibition of neuromuscular systems through modulation of ion concentrations with ion-selective membranes. Nat Mater 2011, 10(10):1-7.
-
(2011)
Nat Mater
, vol.10
, Issue.10
, pp. 1-7
-
-
Song, Y.A.1
Melik, R.2
Rabie, A.N.3
Ibrahim, A.M.S.4
Moses, D.5
Tan, A.6
Han, J.7
Lin, S.J.8
-
90
-
-
77954581072
-
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
-
Kim DH, Viventi J, Amsden JJ, Xiao J, Vigeland L, Kim YS, Blanco JA, Panilaitis B, Frechette ES, Contreras D, Kaplan DL, Omenetto FG, Huang Y, Hwang KC, Zakin MR, Litt B, Rogers JA. Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics. Nat Mater 2010, 9.
-
(2010)
Nat Mater
, vol.9
-
-
Kim, D.H.1
Viventi, J.2
Amsden, J.J.3
Xiao, J.4
Vigeland, L.5
Kim, Y.S.6
Blanco, J.A.7
Panilaitis, B.8
Frechette, E.S.9
Contreras, D.10
Kaplan, D.L.11
Omenetto, F.G.12
Huang, Y.13
Hwang, K.C.14
Zakin, M.R.15
Litt, B.16
Rogers, J.A.17
-
91
-
-
39749179113
-
Online Electromyographic Control of a Robotic Prosthesis
-
Shenoy P, Miller K, Crawford B, Rao R. Online Electromyographic Control of a Robotic Prosthesis. IEEE Trans Biomed Eng 2008, 55(3):1128-1135.
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, Issue.3
, pp. 1128-1135
-
-
Shenoy, P.1
Miller, K.2
Crawford, B.3
Rao, R.4
-
92
-
-
30344465727
-
Myoelectric control of a computer animated hand: A new concept based on the combined use of a tree-structured artificial neural network and a data glove
-
10.1080/03091900512331332546, 16393847
-
Sebelius F, Eriksson L, Balkenius C, Laurell T. Myoelectric control of a computer animated hand: A new concept based on the combined use of a tree-structured artificial neural network and a data glove. J Med Eng Technol 2006, 30:2-10. 10.1080/03091900512331332546, 16393847.
-
(2006)
J Med Eng Technol
, vol.30
, pp. 2-10
-
-
Sebelius, F.1
Eriksson, L.2
Balkenius, C.3
Laurell, T.4
-
93
-
-
47649094596
-
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
-
Oskoei M, Hu H. Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb. IEEE Trans Biomed Eng 2008, 55(8):1956-1965.
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, Issue.8
, pp. 1956-1965
-
-
Oskoei, M.1
Hu, H.2
-
94
-
-
27644466209
-
A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses
-
10.1109/TBME.2005.856295, 16285383
-
Huang Y, Englehart K, Hudgins B, Chan A. A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses. IEEE Trans Biomed Eng 2005, 52(11):1801-1811. 10.1109/TBME.2005.856295, 16285383.
-
(2005)
IEEE Trans Biomed Eng
, vol.52
, Issue.11
, pp. 1801-1811
-
-
Huang, Y.1
Englehart, K.2
Hudgins, B.3
Chan, A.4
-
95
-
-
0042664129
-
A Robust, Real-Time Control Scheme for Multifunction Myoelectric Control
-
10.1109/TBME.2003.813539, 12848352
-
Englehart K, Hudgins B. A Robust, Real-Time Control Scheme for Multifunction Myoelectric Control. IEEE Trans Biomed Eng 2003, 50(7):848-854. 10.1109/TBME.2003.813539, 12848352.
-
(2003)
IEEE Trans Biomed Eng
, vol.50
, Issue.7
, pp. 848-854
-
-
Englehart, K.1
Hudgins, B.2
-
96
-
-
84866161154
-
Wavelet Transforms For Compound Nerve Action Potential Analysis
-
, New Delhi
-
Ramakrishnan A, Sastry R. Wavelet Transforms For Compound Nerve Action Potential Analysis. 1995, 2/7-2/71. , New Delhi.
-
(1995)
-
-
Ramakrishnan, A.1
Sastry, R.2
-
97
-
-
0024178057
-
Neural Network Control of Cybernetic Limb Prostheses
-
Bergantz D, Barad H. Neural Network Control of Cybernetic Limb Prostheses. 10th Int Conf IEEE EMBS 1988, 3:1486-1487.
-
(1988)
10th Int Conf IEEE EMBS
, vol.3
, pp. 1486-1487
-
-
Bergantz, D.1
Barad, H.2
-
98
-
-
84863642373
-
Biologically Inspired Algorithms Applied to Prosthetic Control
-
, Innsbruck
-
Ortiz-Catalan M, Brånemark R, Håkansson B. Biologically Inspired Algorithms Applied to Prosthetic Control. Proc IASTED Int Conf, Biomedical Engineering 2012, 7-15. , Innsbruck.
-
(2012)
Proc IASTED Int Conf, Biomedical Engineering
, pp. 7-15
-
-
Ortiz-Catalan, M.1
Brånemark, R.2
Håkansson, B.3
-
99
-
-
77649305658
-
Multiple binary classifications via linear discriminant analysis for improved controllability of a powered prosthesis
-
Hargrove LJ, Scheme EJ, Englehart KB, Hudgins BS. Multiple binary classifications via linear discriminant analysis for improved controllability of a powered prosthesis. IEEE Trans Neural Syst Rehabil Eng 2010, 18:49-57.
-
(2010)
IEEE Trans Neural Syst Rehabil Eng
, vol.18
, pp. 49-57
-
-
Hargrove, L.J.1
Scheme, E.J.2
Englehart, K.B.3
Hudgins, B.S.4
-
100
-
-
22644440851
-
Refined Myoelectric Control in Below-Elbow Amputees Using Artificial Neural Networks and a Data Glove
-
Sebelius F, Rosén B, Lundborg G. Refined Myoelectric Control in Below-Elbow Amputees Using Artificial Neural Networks and a Data Glove. J Hand Surg 2005, 30A(4):780-789.
-
(2005)
J Hand Surg
, vol.30 A
, Issue.4
, pp. 780-789
-
-
Sebelius, F.1
Rosén, B.2
Lundborg, G.3
-
101
-
-
34247366472
-
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
-
Hargrove L, Englehart K, Hudgins B. A Comparison of Surface and Intramuscular Myoelectric Signal Classification. IEEE Trans Biomed Eng 2007, 54(5):847-853.
-
(2007)
IEEE Trans Biomed Eng
, vol.54
, Issue.5
, pp. 847-853
-
-
Hargrove, L.1
Englehart, K.2
Hudgins, B.3
-
102
-
-
50049093848
-
A Comparison of the Effects of Electrode Implantation and Targeting on Pattern Classification Accuracy for Prosthesis Control
-
3153447, 18713689
-
Farrell T, Weir R. A Comparison of the Effects of Electrode Implantation and Targeting on Pattern Classification Accuracy for Prosthesis Control. IEEE Trans Biomed Eng 2008, 55(9):2198-2211. 3153447, 18713689.
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, Issue.9
, pp. 2198-2211
-
-
Farrell, T.1
Weir, R.2
-
103
-
-
85013932715
-
-
Elsevier, Academic Press, Massachusetts, USA
-
Sörnmo L, Laguna P. Bioelectrical Signal Processing in Cardiac and Neurological Applications 2005, Elsevier, Academic Press, Massachusetts, USA.
-
(2005)
Bioelectrical Signal Processing in Cardiac and Neurological Applications
-
-
Sörnmo, L.1
Laguna, P.2
-
104
-
-
0019463654
-
Experience with Swedish Multifunctional Prosthetic Hands Controlled by Pattern Recognition of Multiple Myoelectric Signals
-
Almström C, Herberts P, Körner L. Experience with Swedish Multifunctional Prosthetic Hands Controlled by Pattern Recognition of Multiple Myoelectric Signals. Int Orthop 1981, 5:15-21.
-
(1981)
Int Orthop
, vol.5
, pp. 15-21
-
-
Almström, C.1
Herberts, P.2
Körner, L.3
-
105
-
-
36248956103
-
Decoding a New Neural-Machine Interface for Control of Artificial Limbs
-
10.1152/jn.00178.2007, 17728391
-
Zhou P, Lowery MM, Englehart KB, Huang H, Li G, Hargrove L, Dewald JPA, Kuiken TA. Decoding a New Neural-Machine Interface for Control of Artificial Limbs. J Neurophysiol 2007, 98:2974-2982. 10.1152/jn.00178.2007, 17728391.
-
(2007)
J Neurophysiol
, vol.98
, pp. 2974-2982
-
-
Zhou, P.1
Lowery, M.M.2
Englehart, K.B.3
Huang, H.4
Li, G.5
Hargrove, L.6
Dewald, J.P.A.7
Kuiken, T.A.8
-
106
-
-
12144251339
-
The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee
-
Kuiken T, Dumanian G, Lipschutz R, Miller L, Stubblefield K. The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee. Prosthetics Orthotics Int 2004, 28(3):245-253.
-
(2004)
Prosthetics Orthotics Int
, vol.28
, Issue.3
, pp. 245-253
-
-
Kuiken, T.1
Dumanian, G.2
Lipschutz, R.3
Miller, L.4
Stubblefield, K.5
-
107
-
-
0015815599
-
Hand prosthesis control via myoelectric patterns
-
10.3109/17453677308989075, 4771275
-
Herberts P, Almström C, Kadefors R, Lawrence PD. Hand prosthesis control via myoelectric patterns. Acta orthopaedica Scandinavica 1973, 44(4):389-409. 10.3109/17453677308989075, 4771275.
-
(1973)
Acta orthopaedica Scandinavica
, vol.44
, Issue.4
, pp. 389-409
-
-
Herberts, P.1
Almström, C.2
Kadefors, R.3
Lawrence, P.D.4
-
108
-
-
67149128290
-
Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal
-
Jiang N, Englehart KB, Parker P. Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal. IEEE transactions on bio-medical engineering 2009, 56(4):1070-1080.
-
(2009)
IEEE transactions on bio-medical engineering
, vol.56
, Issue.4
, pp. 1070-1080
-
-
Jiang, N.1
Englehart, K.B.2
Parker, P.3
-
109
-
-
84861519478
-
Simultaneous and Proportional Estimation of Hand Kinematics from EMG during Mirrored Movements at Multiple Degrees of Freedom
-
Muceli S, Farina D. Simultaneous and Proportional Estimation of Hand Kinematics from EMG during Mirrored Movements at Multiple Degrees of Freedom. IEEE Trans Neural Syst Rehabil Eng 2012, 20(3):371-8..
-
(2012)
IEEE Trans Neural Syst Rehabil Eng
, vol.20
, Issue.3
-
-
Muceli, S.1
Farina, D.2
-
110
-
-
0018196363
-
Compound action potentials recorded from mammalian peripheral nerves following ligation or resuturing
-
1281773, 370366
-
Davis L, Gordon T, Hoffer J, Jhamandas J, Stein R. Compound action potentials recorded from mammalian peripheral nerves following ligation or resuturing. J Physiol 1978, 285:543-559. 1281773, 370366.
-
(1978)
J Physiol
, vol.285
, pp. 543-559
-
-
Davis, L.1
Gordon, T.2
Hoffer, J.3
Jhamandas, J.4
Stein, R.5
-
111
-
-
0018910595
-
Long-Term Effects of Axotomy on Neural Activity During Cat Locomotion
-
1282889, 7431233
-
Gordon T, Hoffer J, Jhamandas J, Stein R. Long-Term Effects of Axotomy on Neural Activity During Cat Locomotion. J Physiol 1980, 303:243-263. 1282889, 7431233.
-
(1980)
J Physiol
, vol.303
, pp. 243-263
-
-
Gordon, T.1
Hoffer, J.2
Jhamandas, J.3
Stein, R.4
-
112
-
-
0020332045
-
Long-Term Neuroelectric Signal Recording from Severed Nerves
-
DeLuca CJ, Gilmore LD, Bloom LJ, Thomson SJ, Cudworth AL, Glimcher MJ. Long-Term Neuroelectric Signal Recording from Severed Nerves. IEEE Trans Rehabil Eng 1982, BME-29(6):393-403.
-
(1982)
IEEE Trans Rehabil Eng
, vol.BME-29
, Issue.6
, pp. 393-403
-
-
DeLuca, C.J.1
Gilmore, L.D.2
Bloom, L.J.3
Thomson, S.J.4
Cudworth, A.L.5
Glimcher, M.J.6
-
113
-
-
34247563831
-
Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb
-
Jia X, Koenig M, Zhang X, Zhang J, Chen T, Chen Z. Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb. J Hand Surgery 2007, 32(5):657-666.
-
(2007)
J Hand Surgery
, vol.32
, Issue.5
, pp. 657-666
-
-
Jia, X.1
Koenig, M.2
Zhang, X.3
Zhang, J.4
Chen, T.5
Chen, Z.6
-
114
-
-
60249084509
-
Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms
-
Kuiken T, Li G, Lock BA, Lipschutz RDR, Miller LAL, Stubblefield KAK, Englehart KBK. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA: J Am Med Assoc 2009, 301(6):619.
-
(2009)
JAMA: J Am Med Assoc
, vol.301
, Issue.6
, pp. 619
-
-
Kuiken, T.1
Li, G.2
Lock, B.A.3
Lipschutz, R.D.R.4
Miller, L.A.L.5
Stubblefield, K.A.K.6
Englehart, K.B.K.7
-
115
-
-
0027674886
-
Sensory nerve recording for closed-loop control to restore motor functions
-
10.1109/10.247801, 8294127
-
Popovic D, Stein R, Jovanovic K, Dai R, Kostov A, Armstrong W. Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 1993, 40(10):1024-1031. 10.1109/10.247801, 8294127.
-
(1993)
IEEE Trans Biomed Eng
, vol.40
, Issue.10
, pp. 1024-1031
-
-
Popovic, D.1
Stein, R.2
Jovanovic, K.3
Dai, R.4
Kostov, A.5
Armstrong, W.6
-
116
-
-
33846086944
-
Original electronic design to perform epimysial and neural stimulation in paraplegia
-
10.1088/1741-2560/3/4/004, 17124331
-
Guiraud D, Stieglitz T, GT G, Divoux J. Original electronic design to perform epimysial and neural stimulation in paraplegia. J Neural Eng 2006, 3:276-286. 10.1088/1741-2560/3/4/004, 17124331.
-
(2006)
J Neural Eng
, vol.3
, pp. 276-286
-
-
Guiraud, D.1
Stieglitz, T.2
GT, G.3
Divoux, J.4
|