메뉴 건너뛰기




Volumn 45, Issue 7, 2012, Pages 1675-1688

Smart sensors/actuators for biomedical applications: Review

Author keywords

Actuators; Biosensors; CNTs; MEMS; Smart implants

Indexed keywords

ANTIBIOTIC THERAPY; ARTIFICIAL JOINT; BACTERIAL BIOFILM; BIOMEDICAL APPLICATIONS; CHRONIC INFECTION; CLINICAL EXPERIENCE; CNTS; CONTINUOUS MONITORING; DETECTION METHODS; HIP ARTHROPLASTIES; IMPLANTABLE BIOSENSORS; IMPLANTABLE DEVICES; ORTHOPEDIC IMPLANT; QUALITY OF LIFE; RETINA IMPLANTS; SURGICAL PROCEDURES; TECHNICAL DESIGN; TOTAL KNEE ARTHROPLASTY;

EID: 84861795027     PISSN: 02632241     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.measurement.2012.02.006     Document Type: Review
Times cited : (73)

References (132)
  • 2
    • 54349086594 scopus 로고    scopus 로고
    • Microfabricated implants for applications in therapeutic delivery, tissue engineering, and biosensing
    • K.M. Ainslie, and T.A. Desai Microfabricated implants for applications in therapeutic delivery, tissue engineering, and biosensing Lab Chip 8 2008 1864 1878
    • (2008) Lab Chip , vol.8 , pp. 1864-1878
    • Ainslie, K.M.1    Desai, T.A.2
  • 3
    • 45749156017 scopus 로고    scopus 로고
    • In vitro immunogenicity of silicon-based micro- and nanostructured surfaces
    • K.M. Ainslie, S.L. Tao, K.C. Popat, and T.A. Desai In vitro immunogenicity of silicon-based micro- and nanostructured surfaces ACS Nano 2 2008 1076 1084
    • (2008) ACS Nano , vol.2 , pp. 1076-1084
    • Ainslie, K.M.1    Tao, S.L.2    Popat, K.C.3    Desai, T.A.4
  • 4
    • 33845907391 scopus 로고    scopus 로고
    • Improved performance of the potentiometric biosensor for the determination of creatinine
    • DOI 10.1080/00032710600952341, PII VN50752761494112
    • C.D. Rasmussen, J.E.T. Andersen, and B. Zachau-Christiansen Improved performance of the potentiometric biosensor for the determination of creatinine Anal. Lett. 52 2007 39 52 (Pubitemid 46025424)
    • (2007) Analytical Letters , vol.40 , Issue.1 , pp. 39-52
    • Rasmussen, C.D.1    Andersen, J.E.T.2    Zachau-Christiansen, B.3
  • 7
    • 59949084531 scopus 로고    scopus 로고
    • Controlling acute inflammation with fast releasing dexamethasone-PLGA microsphere/PVA hydrogel composites for implantable devices
    • U. Bhardwaj, R. Sura, F. Papadimitrakopoulos, and D.J. Burgess Controlling acute inflammation with fast releasing dexamethasone-PLGA microsphere/PVA hydrogel composites for implantable devices J. Diabetes Sci. Technol. 1 2007 8 17
    • (2007) J. Diabetes Sci. Technol. , vol.1 , pp. 8-17
    • Bhardwaj, U.1    Sura, R.2    Papadimitrakopoulos, F.3    Burgess, D.J.4
  • 8
    • 84861796146 scopus 로고    scopus 로고
    • acedido 15.06.10
    • Biacore. < http://www.biacore.com > (acedido 15.06.10).
    • Biacore
  • 14
    • 34447555613 scopus 로고    scopus 로고
    • An in vitro study of the potential of carbon nanotubes and nanofibres to induce inflammatory mediators and frustrated phagocytosis
    • DOI 10.1016/j.carbon.2007.05.011, PII S0008622307002114
    • D.M. Brown, I.A. Kinloch, U. Bangert, A.H. Windle, D.M. Walter, G.S. Walker, C.A. Scotchford, K. Donaldson, and V. Stone An in vitro study of the potential of carbon nanotubes and nanofibres to induce inflammatory mediators and frustrated phagocytosis Carbon 45 2007 1743 1756 (Pubitemid 47069251)
    • (2007) Carbon , vol.45 , Issue.9 , pp. 1743-1756
    • Brown, D.M.1    Kinloch, I.A.2    Bangert, U.3    Windle, A.H.4    Walter, D.M.5    Walker, G.S.6    Scotchford, C.A.7    Donaldson, K.8    Stone, V.9
  • 15
    • 0031335056 scopus 로고    scopus 로고
    • A surface plasmon resonance sensor probe based on retro-reflection
    • PII S0925400597002906
    • C.P. Cahill, K.S. Johnston, and S.S. Yee A surface plasmon resonance sensor probe based on retro-reflection Sens. Actuators, B 45 1997 161 166 (Pubitemid 127433062)
    • (1997) Sensors and Actuators, B: Chemical , vol.45 , Issue.2 , pp. 161-166
    • Cahill, C.P.1    Johnston, K.S.2    Yee, S.S.3
  • 16
    • 33846292259 scopus 로고    scopus 로고
    • Temperature dependent piezoresistive effect of multi-walled carbon nanotube films
    • DOI 10.1016/j.diamond.2006.07.008, PII S0925963506002457
    • C.L. Cao, C.G. Hu, Y.F. Xiong, X.Y. Han, Y. Xi, and J. Miao Temperature dependent piezoresistive effect of multi-walled carbon nanotube films Diam. Relat. Mater. 16 2007 388 392 (Pubitemid 46123944)
    • (2007) Diamond and Related Materials , vol.16 , Issue.2 , pp. 388-392
    • Cao, C.L.1    Hu, C.G.2    Xiong, Y.F.3    Han, X.Y.4    Xi, Y.5    Miao, J.6
  • 18
    • 0020154939 scopus 로고
    • Multicoated gratings: A differential formalism applicable in the entire optical region
    • J. Chandezon, M.T. Dupuis, G. Cornet, and D. Maystre Multicoated gratings: a differential formalism applicable in the entire optical region J. Opt. Soc. Am. 72 1982 839 846
    • (1982) J. Opt. Soc. Am. , vol.72 , pp. 839-846
    • Chandezon, J.1    Dupuis, M.T.2    Cornet, G.3    Maystre, D.4
  • 19
    • 38849203749 scopus 로고    scopus 로고
    • Electrochemical DNA biosensors based on palladium nanoparticles combined with carbon nanotubes
    • Z. Chang, H. Fan, K. Zhao, M. Chen, P. He, and Y. Fang Electrochemical DNA biosensors based on palladium nanoparticles combined with carbon nanotubes Electroanalysis 20 2008 131 136
    • (2008) Electroanalysis , vol.20 , pp. 131-136
    • Chang, Z.1    Fan, H.2    Zhao, K.3    Chen, M.4    He, P.5    Fang, Y.6
  • 20
    • 84861806993 scopus 로고    scopus 로고
    • 20th December acedido 01.06.10
    • Martin Chaplin, Amperometric Biosensors, 20th December 2004. < http://www1.lsbu.ac.uk/biology/enztech/amperometric.html > (acedido 01.06.10).
    • (2004) Amperometric Biosensors
    • Chaplin, M.1
  • 22
    • 33846398507 scopus 로고    scopus 로고
    • Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles
    • DOI 10.1016/j.bios.2006.05.022, PII S0956566306002594
    • S. Chen, R. Yuan, Y. Chai, L. Zhang, N. Wang, and X. Li Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles Biosens. Bioelectron. 22 2007 1268 1274 (Pubitemid 46135972)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1268-1274
    • Chen, S.1    Yuan, R.2    Chai, Y.3    Zhang, L.4    Wang, N.5    Li, X.6
  • 24
    • 33847350159 scopus 로고    scopus 로고
    • An implantable capacitive pressure sensor for biomedical applications
    • DOI 10.1016/j.sna.2006.06.007, PII S0924424706004055
    • C. Chiang, C. Klin, and M. Ju An implantable capacitive pressure sensor for biomedical applications Sens. Actuators, A 134 2007 382 388 (Pubitemid 46349570)
    • (2007) Sensors and Actuators, A: Physical , vol.134 , Issue.2 , pp. 382-388
    • Chiang, C.-C.1    K. Lin, C.-C.2    Ju, M.-S.3
  • 26
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • L.C. Clark Jr., and C. Lyons Electrode systems for continuous monitoring in cardiovascular surgery Ann. N. Y. Acad. Sci. 102 1962 29 45
    • (1962) Ann. N. Y. Acad. Sci. , vol.102 , pp. 29-45
    • Clark, Jr.L.C.1    Lyons, C.2
  • 27
    • 0018753690 scopus 로고
    • Pressure sensitivity in anisotropically etched thin-diaphragm pressure-sensors
    • S.K. Clark, and K.D. Wise Pressure sensitivity in anisotropically etched thin-diaphragm pressure-sensors IEEE Trans. Electron Devices 26 1979 1887 1896
    • (1979) IEEE Trans. Electron Devices , vol.26 , pp. 1887-1896
    • Clark, S.K.1    Wise, K.D.2
  • 28
    • 24944435756 scopus 로고    scopus 로고
    • An autonomous bladder pressure monitoring system
    • DOI 10.1016/j.sna.2005.03.040, PII S0924424705001640
    • J. Coosemans, and R. Puers An autonomous bladder pressure monitoring system Sens. Actuators, A 2005 155 161 (Rome) (Pubitemid 41315846)
    • (2005) Sensors and Actuators, A: Physical , vol.123-124 , pp. 155-161
    • Coosemans, J.1    Puers, R.2
  • 29
    • 33745829744 scopus 로고    scopus 로고
    • Integrating wireless ECG monitoring in textiles
    • DOI 10.1016/j.sna.2005.10.052, PII S0924424705006060
    • J. Coosemans, B. Hermans, R. Puers, Integrating wireless ECG monitoring in textiles, in: The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Sens. Actuators, A, Seoul, Korea, 2006, pp. 48-53. (Pubitemid 44037309)
    • (2006) Sensors and Actuators, A: Physical , vol.130-131 , Issue.SPEC. ISS. , pp. 48-53
    • Coosemans, J.1    Hermans, B.2    Puers, R.3
  • 30
    • 10044268634 scopus 로고    scopus 로고
    • Effect of single wall carbon nanotubes on human HEK293 cells
    • DOI 10.1016/j.toxlet.2004.08.015, PII S0378427404004102
    • D. Cui, F. Tian, C.S. Ozkan, M. Wang, and H. Gao Effect of single wall carbon nanotubes on human HEK293 cells Toxicol. Lett. 155 2005 73 85 (Pubitemid 39600739)
    • (2005) Toxicology Letters , vol.155 , Issue.1 , pp. 73-85
    • Cui, D.1    Tian, F.2    Ozkan, C.S.3    Wang, M.4    Gao, H.5
  • 31
    • 0023506193 scopus 로고
    • Detection of immuno-complex formation via surface plasmon resonance on gold-coated diffraction gratings
    • D.C. Cullen, R.G.W. Brown, and C.R. Lowe Detection of immuno-complex formation via surface plasmon resonance on gold-coated diffraction gratings Biosensors 3 1987 211 225
    • (1987) Biosensors , vol.3 , pp. 211-225
    • Cullen, D.C.1    Brown, R.G.W.2    Lowe, C.R.3
  • 32
    • 0025263208 scopus 로고
    • Direct surface plasmon-polariton immunosensor. Preliminary investigation of the non-specific adsorption of serum components to the sensor interface
    • D.C. Cullen, and C.R. Lowe A direct surface plasmon - polariton immunosensor: preliminary investigation of the non-specific adsorption of serum components to the sensor interface Sens. Actuators, B 1 1990 576 579 (Pubitemid 20699542)
    • (1990) Sensors and Actuators, B: Chemical , vol.B1 , Issue.1-6 , pp. 576-579
    • Cullen, D.C.1    Lowe, C.R.2
  • 33
    • 33745140868 scopus 로고    scopus 로고
    • A fully integrated multisite pressure sensor for wireless arterial flow characterization
    • A.D. DeHennis, and D.W. Kensall A fully integrated multisite pressure sensor for wireless arterial flow characterization J. Microelectromech. Syst. 15 2006 678 685
    • (2006) J. Microelectromech. Syst. , vol.15 , pp. 678-685
    • Dehennis, A.D.1    Kensall, D.W.2
  • 34
    • 0026551323 scopus 로고
    • Biospecific interaction analysis using surface plasmon resonance detection applied to kinetic, binding site and concentration analysis
    • L.G. Fägerstam, A.F. Karlsson, R. Karlsson, B. Persson, and I. Rönnberg Biospecific interaction analysis using surface plasmon resonance detection applied to kinetic, binding site and concentration analysis J. Chromatogr. A 597 1992 397 410
    • (1992) J. Chromatogr. A , vol.597 , pp. 397-410
    • Fägerstam, L.G.1    Karlsson, A.F.2    Karlsson, R.3    Persson, B.4    Rönnberg, I.5
  • 37
    • 84975564537 scopus 로고
    • Rigorous coupled-wave analysis of metallic surface-relief gratings
    • M.G. Gaylord, and T.K. Moharam Rigorous coupled-wave analysis of metallic surface-relief gratings J. Opt. Soc. Am. A 3 1986 1780 1787
    • (1986) J. Opt. Soc. Am. A , vol.3 , pp. 1780-1787
    • Gaylord, M.G.1    Moharam, T.K.2
  • 38
    • 0031441254 scopus 로고    scopus 로고
    • Amperometric biosensors for L-alanine and pyruvate assays in biological fluids
    • DOI 10.1016/S0003-2670(97)00491-1, PII S0003267097004911
    • M. Gilis, H. Durliat, and M. Comtat Amperometric biosensors for L-analine and pyruvate assays in biological fluids Anal. Chim. Acta 355 1997 235 240 (Pubitemid 28035489)
    • (1997) Analytica Chimica Acta , vol.355 , Issue.2-3 , pp. 235-240
    • Gilis, M.1    Durliat, H.2    Comtat, M.3
  • 39
    • 0016589855 scopus 로고
    • Low power integrated circuits for an implantable pulsed doppler ultrasonic blood flowmeter
    • R.W. Gill, and J.D. Meindl Low power integrated circuits for an implantable pulsed doppler ultrasonic blood flowmeter IEEE J. Solid-State Circ. 10 1975 464 471
    • (1975) IEEE J. Solid-State Circ. , vol.10 , pp. 464-471
    • Gill, R.W.1    Meindl, J.D.2
  • 40
    • 0028313712 scopus 로고
    • Fabrication and characterization of a screen-printed disposable amperometric cholesterol biosensor
    • M.A.T. Gilmartin, and J.P. Hart Fabrication and characterization of a screen-printed disposable amperometric cholesterol biosensor The Analyst 119 1994 2331 2336
    • (1994) The Analyst , vol.119 , pp. 2331-2336
    • Gilmartin, M.A.T.1    Hart, J.P.2
  • 41
    • 57649228421 scopus 로고    scopus 로고
    • A fully implantable multi-channel biotelemetry system for measurement of blood flow and temperature: A first evaluation in the green sturgeon
    • A. Grans, M. Axelsson, K. Pitsillides, C. Olsson, J. Hojesjo, R.C. Kaufman, and J.J. Cech Jr. A fully implantable multi-channel biotelemetry system for measurement of blood flow and temperature: a first evaluation in the green sturgeon Hydrobiologia 619 2009 11 25
    • (2009) Hydrobiologia , vol.619 , pp. 11-25
    • Grans, A.1    Axelsson, M.2    Pitsillides, K.3    Olsson, C.4    Hojesjo, J.5    Kaufman, R.C.6    Cech, Jr.J.J.7
  • 42
    • 33847412681 scopus 로고    scopus 로고
    • Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples
    • DOI 10.1016/j.bios.2006.10.007, PII S0956566306004982, Selected Papers from the Ninth World Congress On Biosensors
    • M. Gutierrez, S. Alegret, and M. del Valle Potenciometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples Biosens. Bioelectron. 22 2007 2171 2178 (Pubitemid 46349665)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2171-2178
    • Gutierrez, M.1    Alegret, S.2    Del Valle, M.3
  • 44
    • 0030082486 scopus 로고    scopus 로고
    • Fibre-optic sensor based on surface plasmon resonance
    • J. Homola, and R. Slavik Fibre-optic sensor based on surface plasmon resonance Electron. Lett. 32 1996 480 482 (Pubitemid 126515260)
    • (1996) Electronics Letters , vol.32 , Issue.5 , pp. 480-482
    • Homola, J.1    Slavik, R.2
  • 45
    • 0030351110 scopus 로고    scopus 로고
    • Surface plasmon resonance sensor based on planar light pipe: Theoretical optimization analysis
    • DOI 10.1016/S0925-4005(97)80130-X, PII S0925400596019983
    • J. Homola, and S.S. Yee Surface plasmon resonance sensor based on planar light pipe: theoretical optimization analysis Sens. Actuators, B 37 1996 145 150 (Pubitemid 126394726)
    • (1996) Sensors and Actuators, B: Chemical , vol.37 , Issue.3 , pp. 145-150
    • Homola, J.1    Yee, S.S.2
  • 46
    • 0031164149 scopus 로고    scopus 로고
    • On the sensitivity of surface plasmon resonance sensors with spectral interrogation
    • PII S0925400597001238
    • J. Homola On the sensitivity of surface plasmon resonance sensors with spectral interrogation Sens. Actuators, B 41 1997 207 211 (Pubitemid 127409891)
    • (1997) Sensors and Actuators, B: Chemical , vol.41 , Issue.1-3 , pp. 207-211
    • Homola, J.1
  • 47
    • 0030931102 scopus 로고    scopus 로고
    • A temporary local energy pool coupled to neuronal activity: Fluctuations of extracellular lactate levels in rat brain monitored with rapid-response enzyme-based sensor
    • Y. Hu, and G.S. Wilson A temporary local energy pool coupled to neuronal activity: fluctuations of extracellular lactate levels in rat brain monitored with rapid-response enzyme-based sensor J. Neurochem. 69 1997 1484 1490 (Pubitemid 27406949)
    • (1997) Journal of Neurochemistry , vol.69 , Issue.4 , pp. 1484-1490
    • Hu, Y.1    Wilson, G.S.2
  • 49
    • 32044469813 scopus 로고    scopus 로고
    • Toxicology of carbon nanomaterials: Status, trends, and perspectives on the special issue
    • DOI 10.1016/j.carbon.2005.12.023, PII S0008622306000157, Toxicology of Carbon Nanimaterials
    • R.H. Hurt, M. Monthioux, and A. Kane Toxicology of carbon nanomaterials: status, trends, and perspectives on the special issue Carbon 44 2006 1028 1033 (Pubitemid 43202159)
    • (2006) Carbon , vol.44 , Issue.6 , pp. 1028-1033
    • Hurt, R.H.1    Monthioux, M.2    Kane, A.3
  • 50
    • 14744304334 scopus 로고    scopus 로고
    • Cytotoxicity of carbon nanomaterials: Single-wall nanotube, multi-wall nanotube, and fullerene
    • DOI 10.1021/es048729l
    • G. Jia, H. Wang, L. Yan, X. Wang, R. Pei, T. Yan, Y. Zhao, and X. Guo Cytotoxicity of carbon nanomaterials: single-wall nanotube, multi-wall nanotube, and fullerene Environ. Sci. Technol. 39 2005 1378 1383 (Pubitemid 40333400)
    • (2005) Environmental Science and Technology , vol.39 , Issue.5 , pp. 1378-1383
    • Jia, G.1    Wang, H.2    Yan, L.3    Wang, X.4    Pei, R.5    Yan, T.6    Zhao, Y.7    Guo, X.8
  • 51
    • 0027575999 scopus 로고
    • Fiber-optic chemical sensor based on surface plasmon resonance
    • R.C. Jorgenson, and S.S. Yee A fiber-optic chemical sensor based on surface plasmon resonance Sens. Actuators, B 12 1993 213 220 (Pubitemid 23708558)
    • (1993) Sensors and Actuators, B: Chemical , vol.B12 , Issue.3 , pp. 213-220
    • Jorgenson, R.C.1    Yee, S.S.2
  • 52
    • 0028375706 scopus 로고
    • Development of a prototype gas sensor using surface plasmon resonance on gratings
    • M.J. Jory, P.S. Vukusic, and J.R. Sambles Development of a prototype gas sensor using surface plasmon resonance on gratings Sens. Actuators, B 17 1994 203 209
    • (1994) Sens. Actuators, B , vol.17 , pp. 203-209
    • Jory, M.J.1    Vukusic, P.S.2    Sambles, J.R.3
  • 53
    • 30044441620 scopus 로고    scopus 로고
    • V-type nerve agent detection using a carbon nanotube-based amperometric enzyme electrode
    • DOI 10.1021/ac051052f
    • K.A. Joshi, M. Prouza, M. Kum, J. Wang, J. Tang, R. Haddon, W. Chen, and A. Mulchandani V-type nerve agent detection using a carbon nanotube-based amperometric enzyme electrode Anal. Chem. 78 2006 331 336 (Pubitemid 43050171)
    • (2006) Analytical Chemistry , vol.78 , Issue.1 , pp. 331-336
    • Joshi, K.A.1    Prouza, M.2    Kum, M.3    Wang, J.4    Tang, J.5    Haddon, R.6    Chen, W.7    Mulchandani, A.8
  • 55
    • 71549161131 scopus 로고    scopus 로고
    • An autonomous, capacitive sensor based and battery powered internal bladder pressure monitoring system
    • P. Jourand, R. Puers, An autonomous, capacitive sensor based and battery powered internal bladder pressure monitoring system, in: Eurosensors XXIII Conference, Procedia Chemistry, 2009, pp. 1263-1266.
    • (2009) Eurosensors XXIII Conference, Procedia Chemistry , pp. 1263-1266
    • Jourand, P.1    Puers, R.2
  • 56
    • 0034308297 scopus 로고    scopus 로고
    • Creatinine biosensors: Principles and designs
    • A.J. Killard, and M.R. Smyth Creatinine biosensors: principles and designs TIBTECH 18 2000 433 437
    • (2000) TIBTECH , vol.18 , pp. 433-437
    • Killard, A.J.1    Smyth, M.R.2
  • 57
    • 11144289645 scopus 로고    scopus 로고
    • A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair
    • T. Koivistoinen, S. Junnila, A. Värri, T. Kööbi, A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair, in: Proceedings of 26th Conference, IEEE EMBS, 2004, pp. 2069-2029.
    • (2004) Proceedings of 26th Conference, IEEE EMBS , pp. 2069-2029
    • T. Koivistoinen1
  • 58
    • 0000504383 scopus 로고    scopus 로고
    • Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance
    • A.A. Kolomenskii, P.D. Gershon, and H.A. Schuessler Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance Appl. Opt. 36 1997 6539 6547 (Pubitemid 127743042)
    • (1997) Applied Optics , vol.36 , Issue.25 , pp. 6539-6547
    • Kolomenskii, A.A.1    Gershon, P.D.2    Schuessler, H.A.3
  • 59
    • 0023791131 scopus 로고
    • Surface plasmon resonance immunosensors: Sensitivity considerations
    • R.P.H. Kooyman, H. Kolkman, J.V. Gent, and J. Greve Surface plasmon resonance immunosensors: sensitivity considerations Anal. Chim. Acta 213 1988 35 45
    • (1988) Anal. Chim. Acta , vol.213 , pp. 35-45
    • Kooyman, R.P.H.1    Kolkman, H.2    Gent, J.V.3    Greve, J.4
  • 60
    • 36549004634 scopus 로고    scopus 로고
    • Biomolecules-carbon nanotubes doped conducting polymer nanocomposites and their sensor application
    • DOI 10.1016/j.talanta.2007.08.047, PII S0039914007006145, Micro- and Nanotechnology in Electrochemical Detection Science - dedicated to Professor Joseph Wang on the occasion of his 60th birthday MNED 2007 SI
    • M.C. Kum, K.A. Joshi, W. Chen, N.V. Myung, and A. Mulchandani Biomolecules-carbon nanotubes doped conducting polymer nanocomposites and their sensor application Talanta 74 2007 370 375 (Pubitemid 350192530)
    • (2007) Talanta , vol.74 , Issue.3 , pp. 370-375
    • Kum, M.C.1    Joshi, K.A.2    Chen, W.3    Myung, N.V.4    Mulchandani, A.5
  • 61
    • 33646241796 scopus 로고    scopus 로고
    • Electrocatalytic activity of bamboo-structured carbon nanotubes paste electrode toward hydrogen peroxide
    • F. Kurusu, S. Koide, I. Karube, and M. Gotoh Electrocatalytic activity of bamboo-structured carbon nanotubes paste electrode toward hydrogen peroxide Anal. Lett. 39 2006 903 911
    • (2006) Anal. Lett. , vol.39 , pp. 903-911
    • Kurusu, F.1    Koide, S.2    Karube, I.3    Gotoh, M.4
  • 63
    • 0028530371 scopus 로고
    • A waveguide-coupled surface-plasmon sensor for an aqueous environment
    • C.R. Lavers, and J.S. Wilkinson A waveguide-coupled surface-plasmon sensor for an aqueous environment Sens. Actuators, B 22 1994 75 81
    • (1994) Sens. Actuators, B , vol.22 , pp. 75-81
    • Lavers, C.R.1    Wilkinson, J.S.2
  • 64
    • 0027559885 scopus 로고
    • Principles of biosensing with an extended coupling matrix and surface plasmon resonance
    • B. Liedberg, I. Lundström, and E. Stenberg Principles of biosensing with an extended coupling matrix and surface plasmon resonance Sens. Actuators, B 11 1993 63 72
    • (1993) Sens. Actuators, B , vol.11 , pp. 63-72
    • Liedberg, B.1    Lundström, I.2    Stenberg, E.3
  • 65
    • 1442348967 scopus 로고    scopus 로고
    • Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
    • DOI 10.1021/nl0347233
    • Y. Lin, F. Lu, Y. Tu, and Z. Ren Glucose biosensors based on carbon nanotube nanoelectrode ensembles Nano Lett. 4 2004 191 195 (Pubitemid 38292886)
    • (2004) Nano Letters , vol.4 , Issue.2 , pp. 191-195
    • Lin, Y.1    Lu, F.2    Tu, Y.3    Ren, Z.4
  • 66
    • 29244435811 scopus 로고    scopus 로고
    • Glucose biosensor based on the use of a carbon nanotube paste electrode modified with metallic particles
    • DOI 10.1007/s00604-005-0447-z
    • G.L. Luque, N.F. Ferreyra, and G.A. Rivas Glucose biosensor based on the use of a carbon nanotube paste electrode modified with metallic particles Microchim. Acta 152 2006 277 283 (Pubitemid 41827347)
    • (2006) Microchimica Acta , vol.152 , Issue.SPEC. ISS. , pp. 277-283
    • Luque, G.L.1    Ferreyra, N.F.2    Rivas, G.A.3
  • 67
    • 34047136623 scopus 로고    scopus 로고
    • Wearable health systems: From smart technologies to real applications
    • DOI 10.1109/IEMBS.2006.260948, 4030659, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
    • A. Lymberis, L. Gatzoulis, Wearable health systems: from smart technologies to real applications, in: Engineering in Medicine and Biology Society, 28th Annual International Conference of the IEEE EMBS, NY, 2006, pp. 6789-6792. (Pubitemid 46521488)
    • (2006) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , pp. 6789-6792
    • Lymberis, A.1    Gatzoulis, L.2
  • 69
    • 0005836651 scopus 로고    scopus 로고
    • Single- and multi-wall carbon nanotube field-effect transistors
    • DOI 10.1063/1.122477, PII S0003695198001430
    • R. Martel, T. Schmidt, H.R. Shea, T. Hertel, and Ph. Avouris Single- and multi-wall carbon nanotube field-effect transistors Appl. Phys. Lett. 73 1998 2447 2449 (Pubitemid 128672420)
    • (1998) Applied Physics Letters , vol.73 , Issue.17 , pp. 2447-2449
    • Martel, R.1    Schmidt, T.2    Shea, H.R.3    Hertel, T.4    Avouris, P.5
  • 70
    • 84975646166 scopus 로고
    • Optical chemical sensor based on surface plasmon measurement
    • K. Matsubara, S. Kawata, and S. Minami Optical chemical sensor based on surface plasmon measurement Appl. Opt. 27 1988 1160 1163
    • (1988) Appl. Opt. , vol.27 , pp. 1160-1163
    • Matsubara, K.1    Kawata, S.2    Minami, S.3
  • 72
    • 0000579677 scopus 로고
    • Fabrication and evaluation of nanoelectrode ensembles
    • V.P. Menon, and C.R. Martin Fabrication and evaluation of nanoelectrode ensembles Anal. Chem. 67 1995 1920 1928
    • (1995) Anal. Chem. , vol.67 , pp. 1920-1928
    • Menon, V.P.1    Martin, C.R.2
  • 73
    • 67349137895 scopus 로고    scopus 로고
    • Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
    • D. Morris, S. Coyle, Y. Wua, K.T. Lau, G. Wallace, and D. Diamond Bio-sensing textile based patch with integrated optical detection system for sweat monitoring Sens. Actuators, B 139 2009 231 236
    • (2009) Sens. Actuators, B , vol.139 , pp. 231-236
    • Morris, D.1    Coyle, S.2    Wua, Y.3    Lau, K.T.4    Wallace, G.5    Diamond, D.6
  • 74
    • 0036178322 scopus 로고    scopus 로고
    • Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine
    • DOI 10.1016/S0956-5663(01)00298-6, PII S0956566301002986
    • I. Moser, G. Jobst, and G.A. Urban Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine Biosens. Bioelectron. 17 2002 297 302 (Pubitemid 34159182)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.4 , pp. 297-302
    • Moser, I.1    Jobst, G.2    Urban, G.A.3
  • 76
    • 65049084081 scopus 로고    scopus 로고
    • Electrochemical immunosensors for interleukin-6. Comparison of carbon nanotube forest and gold nanoparticle platforms
    • B.S. Munge, C.E. Krause, R. Malhotra, V. Patel, J.S. Gutkind, and J.F. Rusling Electrochemical immunosensors for interleukin-6. Comparison of carbon nanotube forest and gold nanoparticle platforms Electrochem. Commun. 11 2009 1009 1012
    • (2009) Electrochem. Commun. , vol.11 , pp. 1009-1012
    • Munge, B.S.1    Krause, C.E.2    Malhotra, R.3    Patel, V.4    Gutkind, J.S.5    Rusling, J.F.6
  • 77
    • 0034282271 scopus 로고    scopus 로고
    • Implementing surface plasmon resonance biosensors in drug discovery
    • D.G. Myszka, and R.L. Rich Implementing surface plasmon resonance biosensors in drug discovery Pharm. Sci. Technol. Today 3 2000 310 317
    • (2000) Pharm. Sci. Technol. Today , vol.3 , pp. 310-317
    • Myszka, D.G.1    Rich, R.L.2
  • 78
    • 0030575296 scopus 로고    scopus 로고
    • Single unit recording capabilities of a 100 microelectrode array
    • DOI 10.1016/S0006-8993(96)00321-6
    • C.T. Nordhausen, E.M. Maynard, and R.A. Normann Single unit recording capabilities of a 100 microelectrode array Brain Res. 726 1996 129 140 (Pubitemid 26292238)
    • (1996) Brain Research , vol.726 , Issue.1-2 , pp. 129-140
    • Nordhausen, C.T.1    Maynard, E.M.2    Normann, R.A.3
  • 79
    • 0020192604 scopus 로고
    • Gas detection by means of surface plasmon resonance
    • DOI 10.1016/0250-6874(82)80008-5
    • C. Nylander, B. Liedberg, and T. Lind Gas detection by means of surface plasmon resonance Sens. Actuators, A 3 1982 79 88 (Pubitemid 13459131)
    • (1982) Sensors and Actuators , vol.3 , Issue.1 , pp. 79-88
    • Nylander, C.1    Liedberg, B.2    Lind, T.3
  • 80
    • 33847367030 scopus 로고    scopus 로고
    • Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes
    • DOI 10.1016/j.bios.2006.09.038, PII S0956566306004908, Selected Papers from the Ninth World Congress On Biosensors
    • J. Okuno, K. Maehashi, K. Kerman, Y. Takamur, K. Matsumoto, and E. Tamiya Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes Biosens. Bioelectron. 22 2007 2377 2381 (Pubitemid 46349662)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2377-2381
    • Okuno, J.1    Maehashi, K.2    Kerman, K.3    Takamura, Y.4    Matsumoto, K.5    Tamiya, E.6
  • 81
    • 78649274147 scopus 로고    scopus 로고
    • A review of the biocompatibility of implantable devices: Current challenges to overcome foreign body response
    • Y. Onuki, U. Bhardwaj, F. Papadimitrakopoulos, and D.J. Burgess A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response J. Diabetes Sci. Technol. 2 2008 1003 1015
    • (2008) J. Diabetes Sci. Technol. , vol.2 , pp. 1003-1015
    • Onuki, Y.1    Bhardwaj, U.2    Papadimitrakopoulos, F.3    Burgess, D.J.4
  • 82
    • 35348968380 scopus 로고    scopus 로고
    • A novel amperometric immunosensor based on layer-by-layer assembly of gold nanoparticles-multi-walled carbon nanotubes-thionine multilayer films on polyelectrolyte surface
    • DOI 10.1016/j.aca.2007.08.052, PII S0003267007016091
    • C. Ou, R. Yuan, Y. Chai, M. Tang, R. Chai, and X. He A novel immunosensor based on layer-by-layer assembly of gold nanoparticles-multi-walled carbon nanotubes-thionine multilayer films on polyelectrolyte surface Anal. Chim. Acta 603 2007 205 213 (Pubitemid 47600119)
    • (2007) Analytica Chimica Acta , vol.603 , Issue.2 , pp. 205-213
    • Ou, C.1    Yuan, R.2    Chai, Y.3    Tang, M.4    Chai, R.5    He, X.6
  • 83
    • 12344331232 scopus 로고    scopus 로고
    • Dexamethasone-loaded poly(lactic-co-glycolic) acid microspheres/ poly(vinyl alcohol) hydrogel composite coatings for inflammation control
    • S.D. Patil, F. Papadimitrakopoulos, and D.J. Burgess Dexamethasone-loaded poly(lactic-co-glycolic) acid microspheres/poly(vinyl alcohol) hydrogel composite coatings for inflammation control Diabetes Technol. Therapeutics 6 2004 887 987
    • (2004) Diabetes Technol. Therapeutics , vol.6 , pp. 887-987
    • Patil, S.D.1    Papadimitrakopoulos, F.2    Burgess, D.J.3
  • 84
    • 0026853918 scopus 로고
    • Integrated opto-chemical sensors
    • V.L. Paul Integrated opto-chemical sensors Sens. Actuators, B 8 1992 103 116
    • (1992) Sens. Actuators, B , vol.8 , pp. 103-116
    • Paul, V.L.1
  • 85
    • 0034508087 scopus 로고    scopus 로고
    • E-broidery - Design and fabrication of textile-based computing
    • E.R. Post, M. Orth, P.R. Gershenfeld, and N. Russo E-broidery - design and fabrication of textile-based computing IBM Syst. J. 39 2000 840 860
    • (2000) IBM Syst. J. , vol.39 , pp. 840-860
    • Post, E.R.1    Orth, M.2    Gershenfeld, P.R.3    Russo, N.4
  • 86
    • 4544346167 scopus 로고    scopus 로고
    • Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis
    • A. Radomska, E. Bodenszac, S. Głab, and R. Koncki Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis Talanta 64 2004 603 608
    • (2004) Talanta , vol.64 , pp. 603-608
    • Radomska, A.1    Bodenszac, E.2    Głab, S.3    Koncki, R.4
  • 88
    • 0033955735 scopus 로고    scopus 로고
    • Advances in surface plasmon resonance biosensor analysis
    • DOI 10.1016/S0958-1669(99)00054-3
    • R.L. Rich, and D.G. Myszka Advances in surface plasmon resonance biosensor analysis Curr. Opin. Biotechnol. 11 2000 54 61 (Pubitemid 30099039)
    • (2000) Current Opinion in Biotechnology , vol.11 , Issue.1 , pp. 54-61
    • Rich, R.L.1    Myszka, D.G.2
  • 89
    • 0035152823 scopus 로고    scopus 로고
    • Survey of the year 2000 commercial optical biosensor literature
    • DOI 10.1002/jmr.547
    • R.L. Rich, and D.G. Myszka Survey of the year 2000 commercial optical biosensor literature J. Mol. Recognit. 14 2001 273 294 (Pubitemid 33055840)
    • (2001) Journal of Molecular Recognition , vol.14 , Issue.5 , pp. 273-294
    • Rich, R.L.1    Myszka, D.G.2
  • 90
    • 0036873472 scopus 로고    scopus 로고
    • Survey of the year 2001 commercial optical biosensor literature
    • DOI 10.1002/jmr.598
    • R.L. Rich, and D.G. Myszka Survey of the year 2001 commercial optical biosensor literature J. Mol. Recognit. 15 2002 352 376 (Pubitemid 36107974)
    • (2002) Journal of Molecular Recognition , vol.15 , Issue.6 , pp. 352-376
    • Rich, R.L.1    Myszka, D.G.2
  • 91
    • 36148988796 scopus 로고    scopus 로고
    • Biodegradable micro-osmotic pump for long-term and controlled release of basic fibroblast growth factor
    • DOI 10.1016/j.jconrel.2007.08.024, PII S0168365907004257
    • W.H. Ryu, Z. Huang, F.B. Prinz, S.B. Goodman, and R. Fasching Biodegradable micro-osmotic pump for long-term and controlled release of basic fibroblast growth factor J. Controlled Release 124 2007 98 105 (Pubitemid 350103731)
    • (2007) Journal of Controlled Release , vol.124 , Issue.1-2 , pp. 98-105
    • Ryu, W.1    Huang, Z.2    Prinz, F.B.3    Goodman, S.B.4    Fasching, R.5
  • 92
    • 36348957892 scopus 로고    scopus 로고
    • Implantable stimulator and recording device for artificial prosthesis control
    • DOI 10.1016/j.mejo.2007.10.003, PII S0026269207003060
    • J. Sacristán-Riquelme, and M.T. Osés Implantable stimulator and recording device for artificial prosthesis control Microelectron. J. 38 2007 1135 1149 (Pubitemid 350160759)
    • (2007) Microelectronics Journal , vol.38 , Issue.12 , pp. 1135-1149
    • Sacristan-Riquelme, J.1    Oses, M.T.2
  • 93
    • 0019019666 scopus 로고
    • A monolithic capacitive pressure sensor with pulse-period output
    • C.S. Sander, J.W. Knutti, and J.D. Meindl A monolithic capacitive pressure sensor with pulse-period output IEEE Trans. Electron Devices 27 1980 927 930
    • (1980) IEEE Trans. Electron Devices , vol.27 , pp. 927-930
    • Sander, C.S.1    Knutti, J.W.2    Meindl, J.D.3
  • 94
    • 14744284724 scopus 로고    scopus 로고
    • Development of a creatinine-sensitive sensor for medical analysis
    • DOI 10.1016/j.snb.2004.04.104, PII S0925400504002436, The 17th European Conference on Solid-State Transducers, University of Minho, Guimares, Portugal, September 21-24, 2003
    • W. Sant, M.L. Pourciel-Gouzy, J. Launay, T. Do Conto, R. Colin, A. Martinez, and P. Temple-Boyer Development of a creatinine-sensitive sensor for medical analysis Sens. Actuators, B 103 2004 260 264 (Pubitemid 40329216)
    • (2004) Sensors and Actuators, B: Chemical , vol.103 , Issue.1-2 , pp. 260-264
    • Sant, W.1    Pourciel-Gouzy, M.L.2    Launay, J.3    Do Conto, T.4    Colin, R.5    Martinez, A.6    Temple-Boyer, P.7
  • 95
    • 34547631252 scopus 로고    scopus 로고
    • Determination of phenolic compounds based on co-immobilization of methylene blue and HRP on multi-wall carbon nanotubes
    • A.S. Santos, A.C. Pereira, M.D.P.T. Sotomayor, C.R.T. Tarley, N. Durán, and L.T. Kubota Determination of phenolic compounds based on co-immobilization of methylene blue and HRP on multi-wall carbon nanotubes Electroanalysis 19 2007 549 554
    • (2007) Electroanalysis , vol.19 , pp. 549-554
    • Santos, A.S.1    Pereira, A.C.2    Sotomayor, M.D.P.T.3    Tarley, C.R.T.4    Durán, N.5    Kubota, L.T.6
  • 97
  • 98
    • 0035894281 scopus 로고    scopus 로고
    • A planar amperometric creatinine biosensor employing an insoluble oxidizing agent for removing redox-active interferences
    • DOI 10.1021/ac010497a
    • J.H. Shin, Y.S. Choi, H.J. Lee, S.H. Choi, J. Ha, I.J. Yoon, H. Nam, and G.S. Cha A planar amperometric creatinine biosensor employing an insoluble oxidizing agent for removing redox-active interferences Anal. Chem. 73 2001 5965 5971 (Pubitemid 34042213)
    • (2001) Analytical Chemistry , vol.73 , Issue.24 , pp. 5965-5971
    • Jae Ho, S.1    Yong, S.C.2    Han, J.L.3    Sung, H.C.4
  • 100
    • 22644443621 scopus 로고    scopus 로고
    • Carbon nanotubes for biomedical applications
    • DOI 10.1109/TNB.2005.850478
    • N. Sinha, and J.T.W. Yeow Carbon nanotubes for biomedical applications IEEE Trans. Nanobiosci. 4 2005 180 195 (Pubitemid 41023599)
    • (2005) IEEE Transactions on Nanobioscience , vol.4 , Issue.2 , pp. 180-195
    • Sinha, N.1    Yeow, J.T.-W.2
  • 101
    • 32044445745 scopus 로고    scopus 로고
    • The biocompatibility of carbon nanotubes
    • DOI 10.1016/j.carbon.2005.10.011, PII S000862230500607X, Toxicology of Carbon Nanimaterials
    • S.K. Smart, A.I. Cassady, G.Q. Lu, and D.J. Martin The biocompatibility of carbon nanotubes Carbon 44 2006 1034 1047 (Pubitemid 43202160)
    • (2006) Carbon , vol.44 , Issue.6 , pp. 1034-1047
    • Smart, S.K.1    Cassady, A.I.2    Lu, G.Q.3    Martin, D.J.4
  • 102
    • 0037163006 scopus 로고    scopus 로고
    • Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane
    • A.P. Soldatkin, J. Montoriol, W. Sant, C. Martelet, and N. Jaffrezic-Renault Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane Talanta 58 2002 351 357
    • (2002) Talanta , vol.58 , pp. 351-357
    • Soldatkin, A.P.1    Montoriol, J.2    Sant, W.3    Martelet, C.4    Jaffrezic-Renault, N.5
  • 103
    • 0000779797 scopus 로고    scopus 로고
    • A theoretical investigation of environmental monitoring using surface plasmon resonance waveguide sensors
    • R. Srivastava, M.N. Weiss, H. Groger, P. Lo, and S.F. Luo A theoretical investigation of environmental monitoring using surface plasmon resonance waveguide sensors Sens. Actuators, A 51 1995 211 217 (Pubitemid 126687763)
    • (1996) Sensors and Actuators, A: Physical , vol.51 , Issue.2-3 , pp. 211-217
    • Weiss, M.N.1    Srivastava, R.2    Groger, H.3    Lo, P.4    Luo, S.-F.5
  • 104
    • 0020659594 scopus 로고
    • Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum
    • T. Suchida, and K. Yoda Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum Clin. Chem. 29 1983 51 55 (Pubitemid 13167619)
    • (1983) Clinical Chemistry , vol.29 , Issue.1 , pp. 51-55
    • Tsuchida, T.1    Yoda, K.2
  • 105
    • 33847250973 scopus 로고    scopus 로고
    • Development of a dual-color optical fiber SPR sensor
    • H. Suzuki, M. Sugimoto, Y. Matsui, and J. Kondoh Development of a dual-color optical fiber SPR sensor IEEE Xplore 2005 865 868
    • (2005) IEEE Xplore , pp. 865-868
    • Suzuki, H.1    Sugimoto, M.2    Matsui, Y.3    Kondoh, J.4
  • 107
  • 108
    • 0018653907 scopus 로고
    • A gas chromatographic air analyzer fabricated on a silicon wafer
    • S.C. Terry, J.H. Jerman, and J.B. Angell A gas chromatographic air analyzer fabricated on a silicon wafer Electron Devices, IEEE Trans. 1979 1880 1886 (Pubitemid 10128644)
    • (1979) IEEE Transactions on Electron Devices , vol.26 , Issue.12 , pp. 1880-1886
    • Terry, S.C.1    Jerman, J.H.2    Angell, J.B.3
  • 112
    • 7944224886 scopus 로고    scopus 로고
    • Screen-printed reference electrodes for potentiometric measurements
    • DOI 10.1016/j.aca.2004.08.056, PII S000326700401116X
    • L. Tymecki, E. Zwierkowska, and R. Koncki Screen-printed reference electrodes for potentiometric measurements Anal. Chim. Acta 526 2004 3 11 (Pubitemid 39470127)
    • (2004) Analytica Chimica Acta , vol.526 , Issue.1 , pp. 3-11
    • Tymecki, L.1    Zwierkowska, E.2    Koncki, R.3
  • 113
    • 0037112649 scopus 로고    scopus 로고
    • Ionomer-coated electrodes and nanoelectrode ensembles as electrochemical environmental sensors: Recent advances and prospects
    • P. Ugo, L.M. Moretto, and F. Vezzà Ionomer-coated electrodes and nanoelectrode ensembles as electrochemical environmental sensors: recent advances and prospects ChemPhysChem 3 2002 917 925
    • (2002) ChemPhysChem , vol.3 , pp. 917-925
    • Ugo, P.1    Moretto, L.M.2    Vezzà, F.3
  • 115
    • 33144490054 scopus 로고    scopus 로고
    • Electrochemical immunosensor for cholera toxin using liposomes and poly(3,4-ethylenedioxythiophene)-coated carbon nanotubes
    • DOI 10.1021/ac051435d
    • S. Viswanathan, Wu Li-chen, Ming-Ray Huang, and Ja-an Annie Ho Electrochemical immunosensor for cholera toxin using liposomes and poly(3,4-ethylenedioxythiophene)-coated carbon nanotubes Anal. Chem. 78 2006 1115 1121 (Pubitemid 43271841)
    • (2006) Analytical Chemistry , vol.78 , Issue.4 , pp. 1115-1121
    • Viswanathan, S.1    Wu, L.-C.2    Huang, M.-R.3    Ho, J.-A.A.4
  • 117
    • 0034844040 scopus 로고    scopus 로고
    • Glucose biosensors: 40 Years of advances and challenges
    • DOI 10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-#
    • J. Wang Glucose biosensors: 40 years of advances and challenges Electroanalysis 13 2001 983 988 (Pubitemid 32847325)
    • (2001) Electroanalysis , vol.13 , Issue.12 , pp. 983-988
    • Wang, J.1
  • 118
    • 0036558165 scopus 로고    scopus 로고
    • Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes
    • DOI 10.1021/ac010978u
    • J. Wang, M. Li, Z. Shi, N. Li, and Z. Gu Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes Anal. Chem. 74 2002 1993 1997 (Pubitemid 34465392)
    • (2002) Analytical Chemistry , vol.74 , Issue.9 , pp. 1993-1997
    • Wang, J.1    Li, M.2    Shi, Z.3    Li, N.4    Gu, Z.5
  • 119
    • 0037420379 scopus 로고    scopus 로고
    • Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors
    • DOI 10.1021/ja028951v
    • J. Wang, M. Musameh, and Y. Lin Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors J. Am. Chem. Soc. 125 2003 2408 2409 (Pubitemid 36512224)
    • (2003) Journal of the American Chemical Society , vol.125 , Issue.9 , pp. 2408-2409
    • Wang, J.1    Musameh, M.2    Lin, Y.3
  • 120
    • 0024969501 scopus 로고
    • Signal-to-noise ratio in microelectrode-array-based electrochemical detectors
    • S.G. Weber Signal-to-noise ratio in microelectrode-array-based electrochemical detectors Anal. Chem. 61 1989 295 302
    • (1989) Anal. Chem. , vol.61 , pp. 295-302
    • Weber, S.G.1
  • 121
    • 0030124579 scopus 로고    scopus 로고
    • Experimental investigation of a surface plasmon-based integrated-optic humidity sensor
    • M.N. Weiss, R. Srivastava, and H. Groger Experimental investigation of a surface plasmon-based integrated-optic humidity sensor Electron. Lett. 32 1996 842 843 (Pubitemid 126550724)
    • (1996) Electronics Letters , vol.32 , Issue.9 , pp. 842-843
    • Weiss, M.N.1    Srivastava, R.2    Groger, H.3
  • 123
    • 0029389882 scopus 로고
    • Waveguide surface plasmon resonance sensors
    • R.D. Wilkinson, and J.S. Harris Waveguide surface plasmon resonance sensors Sens. Actuators, B 29 1995 261 267
    • (1995) Sens. Actuators, B , vol.29 , pp. 261-267
    • Wilkinson, R.D.1    Harris, J.S.2
  • 124
    • 34247145825 scopus 로고    scopus 로고
    • Integrated sensors, MEMS, and microsystems: Reflections on a fantastic voyage
    • DOI 10.1016/j.sna.2007.02.013, PII S0924424707000611
    • K.D. Wise Integrated sensors, MEMS, and microsystems: reflections on a fantastic voyage Sens. Actuators, A 136 2007 39 50 (Pubitemid 46590695)
    • (2007) Sensors and Actuators, A: Physical , vol.136 , Issue.1 , pp. 39-50
    • Wise, K.D.1
  • 125
    • 33846281204 scopus 로고    scopus 로고
    • Improving blood compatibility of intravascular oxygen sensors via catalytic decomposition of S-nitrosothiols to generate nitric oxide in situ
    • DOI 10.1016/j.snb.2006.09.025, PII S0925400506006216
    • Y. Wu, A.P. Rojas, G.W. Griffith, A.M. Skrzypchak, N. Lafayette, R.H. Bartlett, and M.E. Meyerhoff Improving blood compatibility of intravascular oxygen sensors via catalytic decomposition of S-nitrosothiols to generate nitric oxide in situ Sens. Actuators, B 121 2007 36 46 (Pubitemid 46123879)
    • (2007) Sensors and Actuators, B: Chemical , vol.121 , Issue.1 , pp. 36-46
    • Wu, Y.1    Rojas, A.P.2    Griffith, G.W.3    Skrzypchak, A.M.4    Lafayette, N.5    Bartlett, R.H.6    Meyerhoff, M.E.7
  • 127
    • 0029885724 scopus 로고    scopus 로고
    • Resolution and sensitivity in surface plasmon microscopy and sensing
    • DOI 10.1016/0956-5663(96)83298-2, Surface Characterization and Optical Sensing Methods in Biosensors
    • E.M. Yeatman Resolution and sensitivity in surface plasmon microscopy and sensing Biosens. Bioelectron. 11 1996 635 649 (Pubitemid 26153673)
    • (1996) Biosensors and Bioelectronics , vol.11 , Issue.6-7 , pp. 635-649
    • Yeatman, E.M.1
  • 129
    • 79956044491 scopus 로고    scopus 로고
    • Generation of continuous and pulsed diagnostic imaging X-ray radiation using a carbon-nanotube-based field-emission cathode
    • G.Z. Yue, Q. Qiu, B. Gao, Y. Cheng, J. Zhang, H. Shimoda, S. Chang, J.P. Lu, and O. Zhou Generation of continuous and pulsed diagnostic imaging X-ray radiation using a carbon-nanotube-based field-emission cathode Appl. Phys. Lett. 81 2002 355 357
    • (2002) Appl. Phys. Lett. , vol.81 , pp. 355-357
    • Yue, G.Z.1    Qiu, Q.2    Gao, B.3    Cheng, Y.4    Zhang, J.5    Shimoda, H.6    Chang, S.7    Lu, J.P.8    Zhou, O.9
  • 132
    • 23944445301 scopus 로고    scopus 로고
    • Developing implantable optical biosensors
    • DOI 10.1016/j.tibtech.2005.07.006, PII S0167779905001952
    • K.J. Ziegler Developing implantable optical biosensors Trends Biotechnol. 23 2005 440 444 (Pubitemid 41188239)
    • (2005) Trends in Biotechnology , vol.23 , Issue.9 , pp. 440-444
    • Ziegler, K.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.