메뉴 건너뛰기




Volumn 1, Issue 1, 2009, Pages 1263-1266

An Autonomous, Capacitive Sensor Based and Battery Powered Internal Bladder Pressure Monitoring System

Author keywords

Battery operated; Capacitive sensor; Implantable; Internal bladder pressure; Minimal invasive

Indexed keywords

BATTERY OPERATED; BATTERY POWERED; CAPACITIVE SENSOR; LITHIUM CELLS; OFF-LINE MONITORING; PRESSURE MONITORING SYSTEM; SENSOR INTERFACE;

EID: 71549161131     PISSN: 18766196     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/j.proche.2009.07.315     Document Type: Conference Paper
Times cited : (13)

References (9)
  • 1
    • 0346848838 scopus 로고    scopus 로고
    • Noninvasive Techniques For The Measurement of Isovolumetric Bladder Pressure
    • Blake C., and Abrams P. Noninvasive Techniques For The Measurement of Isovolumetric Bladder Pressure. J Urol 171 (2004) 12-19
    • (2004) J Urol , vol.171 , pp. 12-19
    • Blake, C.1    Abrams, P.2
  • 2
    • 33744520670 scopus 로고    scopus 로고
    • Variation in Invasive and Noninvasive Measurements of Isovolumetric Bladder Pressure and Categorization of Obstruction According to Bladder Volume
    • Harding C.K., Robson W., Drinnan M.J., Ramsden P.D., Griffiths C., and Pickard R.S. Variation in Invasive and Noninvasive Measurements of Isovolumetric Bladder Pressure and Categorization of Obstruction According to Bladder Volume. J Urol 176 (2006) 172-176
    • (2006) J Urol , vol.176 , pp. 172-176
    • Harding, C.K.1    Robson, W.2    Drinnan, M.J.3    Ramsden, P.D.4    Griffiths, C.5    Pickard, R.S.6
  • 3
    • 71549120453 scopus 로고    scopus 로고
    • Coosemans J. Wireless and Battery-less Medical Monitoring Devices. PhD 2008, Katholieke Universiteit Leuven.
    • Coosemans J. Wireless and Battery-less Medical Monitoring Devices. PhD 2008, Katholieke Universiteit Leuven.
  • 4
    • 59949093110 scopus 로고    scopus 로고
    • Development of a Fully Implantable Wireless Pressure Monitoring System
    • Tan R., McClure T., Lin C.K., Jea D., Dabiri F., Massey T., et al. Development of a Fully Implantable Wireless Pressure Monitoring System. Biomed Microdevices 11 (2009) 259-264
    • (2009) Biomed Microdevices , vol.11 , pp. 259-264
    • Tan, R.1    McClure, T.2    Lin, C.K.3    Jea, D.4    Dabiri, F.5    Massey, T.6
  • 6
    • 24944435756 scopus 로고    scopus 로고
    • An Autonomous Bladder Pressure Monitoring System
    • Coosemans J., and Puers R. An Autonomous Bladder Pressure Monitoring System. Sensors and Actuators A: Physical 123-124 (2005) 155-161
    • (2005) Sensors and Actuators A: Physical , vol.123-124 , pp. 155-161
    • Coosemans, J.1    Puers, R.2
  • 7
    • 0027611922 scopus 로고
    • Capacitive Sensors: When and How to Use Them
    • Puers R. Capacitive Sensors: When and How to Use Them. Sensors and Actuators A: Physical 37-38 (1993) 93-105
    • (1993) Sensors and Actuators A: Physical , vol.37-38 , pp. 93-105
    • Puers, R.1
  • 8
    • 44949086462 scopus 로고    scopus 로고
    • A Low-Cost and Highly Integrated Fiber Optical Pressure Sensor System. and Actuators A: Physical
    • Ceyssens F, Driesen M, Wouters K, Puers R. A Low-Cost and Highly Integrated Fiber Optical Pressure Sensor System. and Actuators A: Physical 2008;145-146:81-6.
    • (2008) , vol.145-146 , pp. 81-86
    • Ceyssens, F.1    Driesen, M.2    Wouters, K.3    Puers, R.4
  • 9
    • 26844460048 scopus 로고    scopus 로고
    • On the Optimization of Ultra Low Power Front-End Interfaces for Capacitive Sensors
    • Bracke W., Merken P., Puers R., and Van Hoof C. On the Optimization of Ultra Low Power Front-End Interfaces for Capacitive Sensors. Sensors and Actuators A: Physical 117 (2005) 273-285
    • (2005) Sensors and Actuators A: Physical , vol.117 , pp. 273-285
    • Bracke, W.1    Merken, P.2    Puers, R.3    Van Hoof, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.