메뉴 건너뛰기




Volumn 101, Issue 4, 2012, Pages 239-245

Dual- versus single-coil implantable defibrillator leads: Review of the literature

Author keywords

Defibrillation threshold; Dual coil; Implantable cardioverter defibrillator; Lead; Lead extraction; Single coil

Indexed keywords

CARDIAC RESYNCHRONIZATION THERAPY; CARDIAC RESYNCHRONIZATION THERAPY DEVICE; DEFIBRILLATION; DEFIBRILLATOR; DUAL COIL DEFIBRILLATOR; ELECTRODE; FOLLOW UP; HEART RIGHT ATRIUM; HUMAN; IMPLANTATION; PATIENT SAFETY; PECTORAL MUSCLE; PULSE GENERATOR; RELIABILITY; REPRODUCIBILITY; REVIEW; SINGLE COIL DEFIBRILLATOR; SUPERIOR CAVA VEIN;

EID: 84860835382     PISSN: 18610684     EISSN: 18610692     Source Type: Journal    
DOI: 10.1007/s00392-011-0407-z     Document Type: Review
Times cited : (24)

References (67)
  • 2
    • 70349528282 scopus 로고    scopus 로고
    • The implantable cardioverter-defibrillator lead: Principles, progress, and promises
    • Haqqani HM, Mond HG (2009) The implantable cardioverter-defibrillator lead: principles, progress, and promises. Pacing Clin Electrophysiol 32:1336-1353
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 1336-1353
    • Haqqani, H.M.1    Mond, H.G.2
  • 3
    • 34248530016 scopus 로고    scopus 로고
    • Transvenous implantable cardioverter-defibrillator leads
    • Maisel WH (2007) Transvenous implantable cardioverter-defibrillator leads. The weakest link. Circulation 115:2461-2463
    • (2007) The Weakest Link. Circulation , vol.115 , pp. 2461-2463
    • Maisel, W.H.1
  • 4
    • 44449150680 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillator lead performance
    • Maisel WH, Kramer DB (2008) Implantable cardioverter-defibrillator lead performance. Circulation 117(2721):2723
    • (2008) Circulation , vol.117 , Issue.2721 , pp. 2723
    • Maisel, W.H.1    Kramer, D.B.2
  • 5
    • 44449116247 scopus 로고    scopus 로고
    • Necessity for surgical revision of defibrillator leads implanted long-term: Causes and management
    • DOI 10.1161/CIRCULATIONAHA.107.740670, PII 0000301720080527000005
    • Eckstein J, Koller MT, Zabel M, Kalusche D, Schaer BA, Osswald S, Sticherling C (2008) Necessity for surgical revision of defibrillator leads implanted long-term. Causes and management. Circulation 117:2727-2733 (Pubitemid 351770453)
    • (2008) Circulation , vol.117 , Issue.21 , pp. 2727-2733
    • Eckstein, J.1    Koller, M.T.2    Zabel, M.3    Kalusche, D.4    Schaer, B.A.5    Osswald, S.6    Sticherling, C.7
  • 6
    • 58849127733 scopus 로고    scopus 로고
    • "Home monitoring" for early detection of implantable cardioverter-defibrillator failure: A single-center prospective observational study
    • Hauck M, Bauer A, Voss F, Weretka S, Katus HA, Becker R (2009) "Home monitoring" for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98:19-24
    • (2009) Clin Res Cardiol , vol.98 , pp. 19-24
    • Hauck, M.1    Bauer, A.2    Voss, F.3    Weretka, S.4    Katus, H.A.5    Becker, R.6
  • 7
    • 34248579318 scopus 로고    scopus 로고
    • Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years
    • DOI 10.1161/CIRCULATIONAHA.106.663807
    • Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, Weisse U, Seidl K (2007) Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation 115:2474-2480 (Pubitemid 46763220)
    • (2007) Circulation , vol.115 , Issue.19 , pp. 2474-2480
    • Kleemann, T.1    Becker, T.2    Doenges, K.3    Vater, M.4    Senges, J.5    Schneider, S.6    Saggau, W.7    Weisse, U.8    Seidl, K.9
  • 8
    • 58149088992 scopus 로고    scopus 로고
    • A changing scenario in the clinical use of implantable defibrillators: The need for long-term data on lead performance
    • Boriani G, Biffi M, Marziali A, Diemberger I, Martignani C (2009) A changing scenario in the clinical use of implantable defibrillators: the need for long-term data on lead performance. Europace 11:1-3
    • (2009) Europace , vol.11 , pp. 1-3
    • Boriani, G.1    Biffi, M.2    Marziali, A.3    Diemberger, I.4    Martignani, C.5
  • 9
    • 58149086015 scopus 로고    scopus 로고
    • Performance and survival of transvenous defibrillation leads: Need for a European data registry
    • Goette A, Cantu F, van Erven L, Geelen P, Halimi F, Merino JL, Morgan JM et al (2009) Performance and survival of transvenous defibrillation leads: need for a European data registry. Europace 11:31-34
    • (2009) Europace , vol.11 , pp. 31-34
    • Goette, A.1    Cantu, F.2    Van Erven, L.3    Geelen, P.4    Halimi, F.5    Merino, J.L.6    Morgan, J.M.7
  • 11
    • 64649087022 scopus 로고    scopus 로고
    • Increasing hazard of Sprint Fidelis implantable cardioverter- defibrillator lead failure
    • Hauser RG, Hayes DL (2009) Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure. Heart Rhythm 6:605-610
    • (2009) Heart Rhythm , vol.6 , pp. 605-610
    • Hauser, R.G.1    Hayes, D.L.2
  • 12
    • 64649099576 scopus 로고    scopus 로고
    • Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads
    • Ellis CR, Rottman JN (2009) Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads. Heart Rhythm 6:619-624
    • (2009) Heart Rhythm , vol.6 , pp. 619-624
    • Ellis, C.R.1    Rottman, J.N.2
  • 13
    • 84860837134 scopus 로고    scopus 로고
    • Boston Scientific, Inc.; Medtronic, Inc.; St. Jude Medical, Inc
    • 2010 Product performance reports. Boston Scientific, Inc.; Medtronic, Inc.; St. Jude Medical, Inc
    • 2010 Product Performance Reports
  • 16
    • 0030220823 scopus 로고    scopus 로고
    • Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator
    • DOI 10.1016/S0735-1097(96)00157-X
    • Bardy GH, Yee R, Jung W (1996) Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators. J Am Coll Cardiol 28:400-410 (Pubitemid 26274335)
    • (1996) Journal of the American College of Cardiology , vol.28 , Issue.2 , pp. 400-410
    • Bardy, G.H.1    Yee, R.2    Jung, W.3
  • 17
    • 0033780310 scopus 로고    scopus 로고
    • Implantable cardioverter/defibrillator: Longterm stability of the defibrillation threshold with a unipolar electrode configuration (active can)
    • Knuefermann P, Wolpert C, Spehl S, Korte T, Manz M, Lüderitz B, Jung W (2000) Implantable cardioverter/defibrillator: longterm stability of the defibrillation threshold with a unipolar electrode configuration (active can). Z Kardiol 89:774-780
    • (2000) Z Kardiol , vol.89 , pp. 774-780
    • Knuefermann, P.1    Wolpert, C.2    Spehl, S.3    Korte, T.4    Manz, M.5    Lüderitz, B.6    Jung, W.7
  • 19
    • 0030717468 scopus 로고    scopus 로고
    • Lead system optimization for transvenous defibrillation
    • DOI 10.1016/S0002-9149(97)00633-4, PII S0002914997006334
    • Gold MR, Foster AH, Shorofsky SR (1997) Lead system optimization for transvenous defibrillation. Am J Cardiol 80: 1163-1167 (Pubitemid 27467404)
    • (1997) American Journal of Cardiology , vol.80 , Issue.9 , pp. 1163-1167
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 22
    • 26244466834 scopus 로고    scopus 로고
    • Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can
    • Lubinski A, Lewicka-Nowak E, Zienciuk A, Krolak T, Kempa M, Pazdyga A, Raczak C, Swiatecka G (2005) Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can. Kardiol Pol 63:234-241
    • (2005) Kardiol Pol , vol.63 , pp. 234-241
    • Lubinski, A.1    Lewicka-Nowak, E.2    Zienciuk, A.3    Krolak, T.4    Kempa, M.5    Pazdyga, A.6    Raczak, C.7    Swiatecka, G.8
  • 23
    • 39649098463 scopus 로고    scopus 로고
    • Optimization of superior vena cava coil position and usage for transvenous defibrillation
    • Gold M, Val-Mejias J, Lennan RB, Tummala R, Goyal S, Kluger J et al (2008) Optimization of superior vena cava coil position and usage for transvenous defibrillation. Heart Rhythm 5: 394-399
    • (2008) Heart Rhythm , vol.5 , pp. 394-399
    • Gold, M.1    Val-Mejias, J.2    Lennan, R.B.3    Tummala, R.4    Goyal, S.5    Kluger, J.6
  • 24
    • 0028197691 scopus 로고
    • Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode
    • Bardy GH, Dolack L, Kudenchuk PJ, Poole JE, Mehra R, Johnson G (1994) Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation 89:1090-1093 (Pubitemid 24076533)
    • (1994) Circulation , vol.89 , Issue.3 , pp. 1090-1093
    • Bardy, G.H.1    Dolack, G.L.2    Kudenchuk, P.J.3    Poole, J.E.4    Mehra, R.5    Johnson, G.6
  • 26
    • 0034944467 scopus 로고    scopus 로고
    • Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: Defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements
    • DOI 10.1053/eupc.2001.0169
    • Schulte B, Sperzel J, Carlsson J, Schwarz T, Ehrlich W, Pitschner HF, Neuzner J (2001) Dual-coil versus single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements. Europace 3:177-180 (Pubitemid 32624493)
    • (2001) Europace , vol.3 , Issue.3 , pp. 177-180
    • Schulte, B.1    Sperzel, J.2    Carlsson, J.3    Schwarz, T.4    Ehrlich, W.5    Pitschner, H.F.6    Neuzner, J.7
  • 27
    • 0042701466 scopus 로고    scopus 로고
    • A randomized prospective study of single coil versus dual coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy
    • DOI 10.1046/j.1460-9592.2003.t01-1-00253.x
    • Rinaldi CA, Simon RDB, Geelen P, Reek P, Baszko A, Kuehl M, Gill JS (2003) A randomized prospective study of single-coil versus dual-coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy. Pacing Clin Electrophysiol 26:1684-1690 (Pubitemid 36936743)
    • (2003) PACE - Pacing and Clinical Electrophysiology , vol.26 , Issue.8 , pp. 1684-1690
    • Rinaldi, C.A.1    Simon, R.D.B.2    Geelen, P.3    Reek, S.4    Baszko, A.5    Kuehl, M.6    Gill, J.S.7
  • 28
    • 12144291388 scopus 로고    scopus 로고
    • Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds
    • DOI 10.1111/j.1540-8159.2004.00439.x
    • Rüb N, Schweitzer O, Mewis C, Kettering K, Kuehlkamp V (2004) Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds. Pacing Clin Electrophysiol 27:346-351 (Pubitemid 38352514)
    • (2004) PACE - Pacing and Clinical Electrophysiology , vol.27 , Issue.3 , pp. 346-351
    • Rub, N.1    Doernberger, V.2    Smits, K.3    Schweitzer, O.4    Mewis, C.5    Kettering, K.6    Kuehlkamp, V.7
  • 30
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the Low Energy Safety Study (LESS)
    • DOI 10.1161/01.CIR.0000015508.59749.F5
    • Gold MR, Higgins S, Klein R, Gilliam R, Kopelman H, Hessen S, Payne J, Strickberger SA, Breiter D, Hahn S (2002) Efficacy and temporal stability of reduced safety margins for ventricular defibrillation. Primary results from the Low Energy Safety Study (LESS). Circulation 105:2043-2048 (Pubitemid 34465266)
    • (2002) Circulation , vol.105 , Issue.17 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3    Gilliam, F.R.4    Kopelman, H.5    Hessen, S.6    Payne, J.7    Strickberger, S.A.8    Breiter, D.9    Hahn, S.10
  • 31
    • 77749320077 scopus 로고    scopus 로고
    • Does defibrillation threshold increase as left ventricular ejection fraction decreases?
    • Val-Mejias JE, Oza A (2010) Does defibrillation threshold increase as left ventricular ejection fraction decreases? Europace 12:385-388
    • (2010) Europace , vol.12 , pp. 385-388
    • Val-Mejias, J.E.1    Oza, A.2
  • 32
    • 79953790513 scopus 로고    scopus 로고
    • Defibrillation testing at the time of implantable cardioverter defibrillator implantation: Results of the European Heart Rhythm Association survey
    • Morgan JM, Marinskis G (2011) Defibrillation testing at the time of implantable cardioverter defibrillator implantation: results of the European Heart Rhythm Association survey. Europace 13:581-582
    • (2011) Europace , vol.13 , pp. 581-582
    • Morgan, J.M.1    Marinskis, G.2
  • 33
    • 34547887245 scopus 로고    scopus 로고
    • Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: A nation-wide survey
    • DOI 10.1093/europace/eum083
    • Brigniole M, Raciti G, Bongiorni MG, Da Martine G, Favale S, Gasparini M, Luise R, Ochetta E, Prolemer A (2007) Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: a nation-wide survey. Europace 9:540-543 (Pubitemid 47249446)
    • (2007) Europace , vol.9 , Issue.7 , pp. 540-543
    • Brignole, M.1    Raciti, G.2    Bongiorni, M.G.3    De Martino, G.4    Favale, S.5    Gasparini, M.6    Luise, R.7    Occhetta, E.8    Proclemer, A.9
  • 38
    • 48249102680 scopus 로고    scopus 로고
    • Right pectoral implantable cardioverter defibrillators: Role of the proximal (SVC) coil
    • Varma N, Efimov I (2008) Right pectoral implantable cardioverter defibrillators: role of the proximal (SVC) coil. Pacing Clin Electrophysiol 31:1025-1035
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1025-1035
    • Varma, N.1    Efimov, I.2
  • 39
    • 0028864523 scopus 로고
    • Elevated defibrillation thresholds when right sided venous access is used for nonthoracotomy implantable defibrillator lead implantation
    • for the Endotak investigators
    • Epstein AE, Kay N, Plumb VJ, Voshage-Stahl L, Hull ML, for the Endotak investigators (1995) Elevated defibrillation thresholds when right sided venous access is used for nonthoracotomy implantable defibrillator lead implantation. J Cardiovasc Electrophysiol 6:979-986
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 979-986
    • Epstein, A.E.1    Kay, N.2    Plumb, V.J.3    Voshage-Stahl, L.4    Hull, M.L.5
  • 40
    • 0032782613 scopus 로고    scopus 로고
    • Defibrillation thresholds are increased by right-sided implantation of totally transvenous implantable cardioverter defibrillators
    • DOI 10.1111/j.1540-8159.1999.tb00599.x
    • Friedman PA, Rasmussen MJ, Grice S, Trusty J, Glikson M, Stanton MS (1999) Defibrillation thresholds are increased by right-sided implantation of totally transvenous implantable cardioverter defibrillators. Pacing Clin Electrophysiol 22: 1186-1192 (Pubitemid 29382333)
    • (1999) PACE - Pacing and Clinical Electrophysiology , vol.22 , Issue.8 , pp. 1186-1192
    • Friedman, P.A.1    Rasmussen, M.J.2    Grice, S.3    Trusty, J.4    Glikson, M.5    Stanton, M.S.6
  • 41
    • 34447281719 scopus 로고    scopus 로고
    • Comparison of defibrillation efficacy and survival associated with right versus left pectoral placement for mplantable defibrillators
    • DOI 10.1016/j.amjcard.2007.02.087, PII S0002914907007126
    • Gold MR, Shih HT, Herre J, Breiter D, Zhang Y, Schwarz M, for the Low Energy Safety Study Investigators (2007) Comparison of defibrillation efficacy and survival associated with right versus left pectoral placement for implantable defibrillators. Am J Cardiol 100:243-246 (Pubitemid 47041987)
    • (2007) American Journal of Cardiology , vol.100 , Issue.2 , pp. 243-246
    • Gold, M.R.1    Shih, H.-T.2    Herre, J.3    Breiter, D.4    Zhang, Y.5    Schwartz, M.6
  • 42
    • 0031913093 scopus 로고    scopus 로고
    • Comparison of right- and left-sided pectoral implantation parameters with the Jewel active can cardiodefibrillator
    • DOI 10.1111/j.1540-8159.1998.tb00070.x
    • Flaker GC, Tummala R, Wilson J (1998) Comparison of rightand left-sided pectoral implantation parameters with the Jewel Active Can cardiodefibrillator. The World Wide Jewel Investigators. Pacing Clin Electrophysiol 21:447-451 (Pubitemid 28090667)
    • (1998) PACE - Pacing and Clinical Electrophysiology , vol.21 , Issue.2 , pp. 447-451
    • Flaker, G.C.1    Tummala, R.2    Wilson, J.3
  • 45
    • 0029828038 scopus 로고    scopus 로고
    • Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms
    • Swerdlow CD, Fan W, Brewer JE (1996) Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms. Circulation 94:2278-2284 (Pubitemid 26360525)
    • (1996) Circulation , vol.94 , Issue.9 , pp. 2278-2284
    • Swerdlow, C.D.1    Fan, W.2    Brewer, J.E.3
  • 46
    • 77954367840 scopus 로고    scopus 로고
    • From defibrillation theory to clinical implications
    • Irnich W (2010) From defibrillation theory to clinical implications. Pacing Clin Electrophysiol 33:814-825
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 814-825
    • Irnich, W.1
  • 47
    • 77956946087 scopus 로고    scopus 로고
    • Acieving low defibrillation thresholds at implant: Pharmacological influences, RV-coil polarity and position, SVC coil usage and positioning, pulse width settings, and the azygous vein
    • Kroll MW, Schwab JO (2010) Acieving low defibrillation thresholds at implant: pharmacological influences, RV-coil polarity and position, SVC coil usage and positioning, pulse width settings, and the azygous vein. Fundam Clin Pharmacol 24:561-573
    • (2010) Fundam Clin Pharmacol , vol.24 , pp. 561-573
    • Kroll, M.W.1    Schwab, J.O.2
  • 49
    • 0032192087 scopus 로고    scopus 로고
    • Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study
    • DOI 10.1016/S1010-7940(98)00215-2, PII S1010794098002152
    • Winter J, Heil JE, Schumann C, Lin Y, Schannwell CM, Michel U, Schipke JD, Schulte HD, Gams E (1998) Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study. Eur J Cardiothorac Surg 14:419-425 (Pubitemid 28520132)
    • (1998) European Journal of Cardio-thoracic Surgery , vol.14 , Issue.4 , pp. 419-425
    • Winter, J.1    Heil, J.E.2    Schumann, C.3    Lin, Y.4    Schannwell, C.M.5    Michel, U.6    Schipke, J.D.7    Schulte, H.D.8    Gams, E.9
  • 51
    • 3242677680 scopus 로고    scopus 로고
    • Optimization of atrial defibrillation with a dual-coil, active pectoral lead system
    • DOI 10.1046/j.1540-8167.2004.03684.x
    • Rashaba EJ, Shorofsky SR, Peters RW, Gold MR (2004) Optimization of atrial defibrillation with dual-coil, active pectoral lead system. J Cardiovasc Electrophysiol 15:790-794 (Pubitemid 38951852)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.7 , pp. 790-794
    • Rashba, E.J.1    Shorofsky, S.R.2    Peters, R.W.3    Gold, M.R.4
  • 52
    • 0032727545 scopus 로고    scopus 로고
    • Atrial defibrillation with a transvenous lead: A randomized comparison of active can shocking pathways
    • Cooklin M, Olsovsky MR, Brockmann RG, Shorofsky SR, Gold MR (1999) Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways. J Am Coll Cardiol 34:358-362
    • (1999) J Am Coll Cardiol , vol.34 , pp. 358-362
    • Cooklin, M.1    Olsovsky, M.R.2    Brockmann, R.G.3    Shorofsky, S.R.4    Gold, M.R.5
  • 53
    • 12144255055 scopus 로고    scopus 로고
    • Clinical predictors of atrial defibrillation thresholds with a dual-coil, active pectoral lead system
    • DOI 10.1016/j.hrthm.2004.10.033, PII S1547527104007647
    • Rashaba EJ, Shorofski SR, Brown T, Peters RW, Gold MR (2005) Clinical predictors of atrial defrillation thresholds with a dual-coil, active pectoral lead system. Heart Rhythm 2:49-54 (Pubitemid 40104309)
    • (2005) Heart Rhythm , vol.2 , Issue.1 , pp. 49-54
    • Rashba, E.J.1    Shorofsky, S.R.2    Brown, T.3    Peters, R.W.4    Gold, M.R.5
  • 55
    • 3042745792 scopus 로고    scopus 로고
    • Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement
    • DOI 10.1016/j.eupc.2003.09.001, PII S1099512903001399
    • Lickfett L, Bitzen A, Arepally A, Nasir K, Wolpert C, Jeong KM, Krause W, Schimpf R, Lewalter T, Calcins H, Jung W, Lüderitz B (2004) Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace 6:25-31 (Pubitemid 38949864)
    • (2004) Europace , vol.6 , Issue.1 , pp. 25-31
    • Lickfett, L.1    Bitzen, A.2    Arepally, A.3    Nasir, K.4    Wolpert, C.5    Jeong, K.-M.6    Krause, U.7    Schimpf, R.8    Lewalter, T.9    Calkins, H.10    Jung, W.11    Luderitz, B.12
  • 56
    • 77953362866 scopus 로고    scopus 로고
    • Complications associated with revision of Sprint Fidelis leads: Report from the Canadian Heart Rhythm Society Device Advisory Committee
    • Parkash R, Crystal E, Bashir J, Simpson C, Birnie D, Sterns L, Exner D (2010) Complications associated with revision of Sprint Fidelis leads: report from the Canadian Heart Rhythm Society Device Advisory Committee. Circulation 121:2384-2387
    • (2010) Circulation , vol.121 , pp. 2384-2387
    • Parkash, R.1    Crystal, E.2    Bashir, J.3    Simpson, C.4    Birnie, D.5    Sterns, L.6    Exner, D.7
  • 57
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart rhythm society expert consensus on facilities, training, indications, and patient management: This document was endorsed by the American Heart Association (AHA)
    • Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Camillo RG, Crossley GH 3rd et al (2009) Transvenous lead extraction: heart rhythm society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm 6:1085-1094
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1094
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3    Bongiorni, M.G.4    Camillo, R.G.5    Crossley III, G.H.6
  • 58
    • 66749148454 scopus 로고    scopus 로고
    • A singlecentre experience of over one thousand lead extractions
    • Kennergren C, Bjurman C, Wiklund R, Gäbel J (2009) A singlecentre experience of over one thousand lead extractions. Europace 11:612-617
    • (2009) Europace , vol.11 , pp. 612-617
    • Kennergren, C.1    Bjurman, C.2    Wiklund, R.3    Gäbel, J.4
  • 59
    • 0036461637 scopus 로고    scopus 로고
    • Malfunction of endocardial defibrillator leads and lead extraction: Where do they meet?
    • Bracke FALE, Meijer A, van Gelder LM (2002) Malfunction of endocardial defibrillator leads and lead extraction: where do they meet? Europace 4:19-24
    • (2002) Europace , vol.4 , pp. 19-24
    • Fale, B.1    Meijer, A.2    Van Gelder, L.M.3
  • 60
    • 77956812591 scopus 로고    scopus 로고
    • Is the transvenous extraction of cardioverter-defibrillator leads more hazardous than of pacemaker leads
    • Malecka B, Kutarski A, Grabowski M (2010) Is the transvenous extraction of cardioverter-defibrillator leads more hazardous than of pacemaker leads. Kardiol Pol 68:884-890
    • (2010) Kardiol Pol , vol.68 , pp. 884-890
    • Malecka, B.1    Kutarski, A.2    Grabowski, M.3
  • 61
    • 0037623303 scopus 로고    scopus 로고
    • Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management
    • DOI 10.1046/j.1540-8167.2003.02500.x
    • Cooper JM, Stephenson EA, Berul CI, Walsh EP, Epstein LM (2003) Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: implications for implantation and management. J Cardiovasc Electrophysiol 14:344-349 (Pubitemid 36529017)
    • (2003) Journal of Cardiovascular Electrophysiology , vol.14 , Issue.4 , pp. 344-349
    • Cooper, J.M.1    Stephenson, E.A.2    Berul, C.I.3    Walsh, E.P.4    Epstein, L.M.5
  • 62
    • 78349263072 scopus 로고    scopus 로고
    • Transvenous extraction performance of expanded polytetrafluoroethylene covered ICD leads in comparison to traditional ICD leads in humans
    • Di Cori A, Bongiorni MG, Zucchelli G, Segreti L, Viani S, Paperini L, Soldati E (2010) Transvenous extraction performance of expanded polytetrafluoroethylene covered ICD leads in comparison to traditional ICD leads in humans. Pacing Clin Electrophysiol 33:1376-1381
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1376-1381
    • Di Cori, A.1    Bongiorni, M.G.2    Zucchelli, G.3    Segreti, L.4    Viani, S.5    Paperini, L.6    Soldati, E.7
  • 63
    • 44349179244 scopus 로고    scopus 로고
    • Extraction of transvenous pacing and ICD leads
    • DOI 10.1111/j.1540-8159.2008.01079.x
    • Smith MC, Love CJ (2008) Extraction of transvenous pacing and ICD leads. Pacing Clin Electrophysiol 31:736-752 (Pubitemid 351749317)
    • (2008) PACE - Pacing and Clinical Electrophysiology , vol.31 , Issue.6 , pp. 736-752
    • Smith, M.C.1    Love, C.J.2
  • 64
    • 77749323179 scopus 로고    scopus 로고
    • Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction
    • Hauser RG, Katsiyiannis WT, Gornick CC, Almquist AK, Kallinen LM (2010) Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction. Europace 12:395-401
    • (2010) Europace , vol.12 , pp. 395-401
    • Hauser, R.G.1    Katsiyiannis, W.T.2    Gornick, C.C.3    Almquist, A.K.4    Kallinen, L.M.5
  • 65
    • 77953849157 scopus 로고    scopus 로고
    • Extraction of cardiac rhythm devices: Indications, techniques and outcomes for the removal of pacemaker and defibrillator leads
    • Farooqi FM, Talsania S, Hamid S, Rinaldi CA (2010) Extraction of cardiac rhythm devices: indications, techniques and outcomes for the removal of pacemaker and defibrillator leads. Int J Clin Pract 64:1140-1147
    • (2010) Int J Clin Pract , vol.64 , pp. 1140-1147
    • Farooqi, F.M.1    Talsania, S.2    Hamid, S.3    Rinaldi, C.A.4
  • 66
    • 77956837825 scopus 로고    scopus 로고
    • Complications and lead extraction in cardiac pacing and defibrillation
    • Bracke F (2008) Complications and lead extraction in cardiac pacing and defibrillation. Neth Heart J 16(Suppl 1):S28-S31
    • (2008) Neth Heart J , vol.16 , Issue.SUPPL. 1
    • Bracke, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.