메뉴 건너뛰기




Volumn 94, Issue 9, 1996, Pages 2278-2284

Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms

Author keywords

charge burping; defibrillation; waves

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CARDIOVERSION; DEFIBRILLATION; DOG; HEART ARRHYTHMIA; HEART CONDUCTION; HEART MUSCLE POTENTIAL; HEART MUSCLE REFRACTORY PERIOD; NONHUMAN; PRIORITY JOURNAL;

EID: 0029828038     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.94.9.2278     Document Type: Article
Times cited : (64)

References (45)
  • 1
    • 0023792839 scopus 로고
    • Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs
    • Chapman P, Vetter J, Souza J, Troupp P, Wetherbee J, Hoffmann R. Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs. J Am Coll Cardiol. 1988;12:739-745.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 739-745
    • Chapman, P.1    Vetter, J.2    Souza, J.3    Troupp, P.4    Wetherbee, J.5    Hoffmann, R.6
  • 2
    • 0024538635 scopus 로고
    • Improved internal defibrillation efficacy with a biphasic waveform
    • Fain ES, Sweeney MB, Franz MR. Improved internal defibrillation efficacy with a biphasic waveform. Am Heart J. 1989;117:358-364.
    • (1989) Am Heart J , vol.117 , pp. 358-364
    • Fain, E.S.1    Sweeney, M.B.2    Franz, M.R.3
  • 3
    • 0024448644 scopus 로고
    • A prospective, randomized evaluation of biphasic vs monophasic pulses on defibrillation efficacy in humans
    • Bardy G, Ivey I, Allen M, Johnson G, Mehra R, Greene H. A prospective, randomized evaluation of biphasic vs monophasic pulses on defibrillation efficacy in humans. J Am Coll Cardiol. 1989;14:728-733.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 728-733
    • Bardy, G.1    Ivey, I.2    Allen, M.3    Johnson, G.4    Mehra, R.5    Greene, H.6
  • 4
    • 0024552857 scopus 로고
    • Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform
    • Winkle RA, Mead H, Ruder MA, Gaudiani V, Buch WS, Pless B, Sweeney M, Schmidt P. Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform. Am Heart J. 1989;117:122-127.
    • (1989) Am Heart J , vol.117 , pp. 122-127
    • Winkle, R.A.1    Mead, H.2    Ruder, M.A.3    Gaudiani, V.4    Buch, W.S.5    Pless, B.6    Sweeney, M.7    Schmidt, P.8
  • 6
    • 0028263225 scopus 로고
    • Mechanisms of electrical defibrillation: Impact of new experimental defibrillator waveforms
    • Blanchard S, Ideker R. Mechanisms of electrical defibrillation: impact of new experimental defibrillator waveforms. Am Heart J. 1994;127:970-977.
    • (1994) Am Heart J , vol.127 , pp. 970-977
    • Blanchard, S.1    Ideker, R.2
  • 8
    • 0028034988 scopus 로고
    • A minimal model of the single capacitor biphasic defibrillation waveform
    • Kroll M. A minimal model of the single capacitor biphasic defibrillation waveform. Pacing Clin Electrophysiol. 1994;17:1782-1792.
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 1782-1792
    • Kroll, M.1
  • 9
    • 0025637041 scopus 로고
    • Strength-duration and probability of success curves for defibrillation with biphasic waveforms
    • Feeser S, Tang A, Kavanagh K, Rollins D, Smith WM, Wolf P, Ideker R. Strength-duration and probability of success curves for defibrillation with biphasic waveforms. Circulation. 1990;82: 2128-2141.
    • (1990) Circulation , vol.82 , pp. 2128-2141
    • Feeser, S.1    Tang, A.2    Kavanagh, K.3    Rollins, D.4    Smith, W.M.5    Wolf, P.6    Ideker, R.7
  • 10
    • 0023206065 scopus 로고
    • Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms
    • Dixon EG, Tang AS, Wolf PD, Meador JT, Fine MJ, Calfee RV, Ideker RE. Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms. Circulation. 1987;76: 1176-1184.
    • (1987) Circulation , vol.76 , pp. 1176-1184
    • Dixon, E.G.1    Tang, A.S.2    Wolf, P.D.3    Meador, J.T.4    Fine, M.J.5    Calfee, R.V.6    Ideker, R.E.7
  • 11
    • 0024591031 scopus 로고
    • Ventricular defibrillation using biphasic waveforms: The importance of phasic defibrillation
    • Tang A, Yabe S, Wharton J, Dolker M, Smith W, Ideker R. Ventricular defibrillation using biphasic waveforms: the importance of phasic defibrillation. J Am Coll Cardiol. 1989;13:207-214.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 207-214
    • Tang, A.1    Yabe, S.2    Wharton, J.3    Dolker, M.4    Smith, W.5    Ideker, R.6
  • 12
    • 0029020832 scopus 로고
    • Responses of the transmembrane potential of myocardial cells during a shock
    • Zhou X, Rollins D, Smith W, Ideker R. Responses of the transmembrane potential of myocardial cells during a shock. J Cardiovasc Electrophysiol. 1995;6:252-263.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 252-263
    • Zhou, X.1    Rollins, D.2    Smith, W.3    Ideker, R.4
  • 14
    • 0028926798 scopus 로고
    • Optimal truncation of defibrillation pulses
    • Irnich W. Optimal truncation of defibrillation pulses. Pacing Clin Electrophysiol. 1995;18:673-688.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 673-688
    • Irnich, W.1
  • 16
    • 0028850822 scopus 로고
    • A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF 65% capacitance pulses using a unipolar defibrillation system
    • Bardy G, Poole J, Kudenchuk P, Dolack G, Raitt M, Jones G, Mehra R, Troutman C, Anderson J, Johnson G. A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF 65% capacitance pulses using a unipolar defibrillation system. Circulation. 1995;91:91-95.
    • (1995) Circulation , vol.91 , pp. 91-95
    • Bardy, G.1    Poole, J.2    Kudenchuk, P.3    Dolack, G.4    Raitt, M.5    Jones, G.6    Mehra, R.7    Troutman, C.8    Anderson, J.9    Johnson, G.10
  • 17
    • 0028110428 scopus 로고
    • Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators
    • Swerdlow C, Kass R, Hwang C, Chen P-S, Raissi S. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators. Circulation. 1994;90:1840-1846.
    • (1994) Circulation , vol.90 , pp. 1840-1846
    • Swerdlow, C.1    Kass, R.2    Hwang, C.3    Chen, P.-S.4    Raissi, S.5
  • 18
    • 0017801155 scopus 로고
    • Effect of pentobarbital anesthesia on ventricular defibrillation threshold in dogs
    • Babbs C. Effect of pentobarbital anesthesia on ventricular defibrillation threshold in dogs. Am Heart J. 1978;95:331-337.
    • (1978) Am Heart J , vol.95 , pp. 331-337
    • Babbs, C.1
  • 19
    • 0018742975 scopus 로고
    • The effect of prolonged pentobarbital anesthesia on cardiac electrophysiology and inotropy of the dog heart in situ
    • Amlie J, Owren T. The effect of prolonged pentobarbital anesthesia on cardiac electrophysiology and inotropy of the dog heart in situ. Acta Pharmacol Toxicol. 1979;44:264-271.
    • (1979) Acta Pharmacol Toxicol , vol.44 , pp. 264-271
    • Amlie, J.1    Owren, T.2
  • 20
    • 0028817517 scopus 로고
    • Low voltage shocks have a significantly higher tilt of the internal electric field than do high voltage shocks
    • Brewer J, Tvedt M, Adams T, Kroll M. Low voltage shocks have a significantly higher tilt of the internal electric field than do high voltage shocks. Pacing Clin Electrophysiol. 1995;18(pt II):214-220.
    • (1995) Pacing Clin Electrophysiol , vol.18 , Issue.2 PT , pp. 214-220
    • Brewer, J.1    Tvedt, M.2    Adams, T.3    Kroll, M.4
  • 21
    • 0024206230 scopus 로고
    • Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs
    • Chapman PD, Wetherbee JN, Vetter JW, Troup P, Souza J. Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs. Pacing Clin Electrophysiol. 1988;11:1045-1050.
    • (1988) Pacing Clin Electrophysiol , vol.11 , pp. 1045-1050
    • Chapman, P.D.1    Wetherbee, J.N.2    Vetter, J.W.3    Troup, P.4    Souza, J.5
  • 22
    • 0027243277 scopus 로고
    • A minimal model of the monophasic defibrillation pulse
    • Kroll M. A minimal model of the monophasic defibrillation pulse. Pacing Clin Electrophysiol. 1993;16:769-777.
    • (1993) Pacing Clin Electrophysiol , vol.16 , pp. 769-777
    • Kroll, M.1
  • 23
    • 10244263615 scopus 로고
    • The chronaxie time and its practical importance
    • Irnich W. The chronaxie time and its practical importance. Pacing Clin Electrophysiol. 1980;8:870-888.
    • (1980) Pacing Clin Electrophysiol , vol.8 , pp. 870-888
    • Irnich, W.1
  • 24
    • 0028758204 scopus 로고
    • A Bayesian up-down estimator of the 80% effective defibrillation dose
    • Piscataway, NJ: IEEE/EMBS Conference
    • Malkin R, Compos A, Raymond L, Bernstein R. A Bayesian up-down estimator of the 80% effective defibrillation dose. Proc IEEE/EMBS Conference. Piscataway, NJ: IEEE/EMBS Conference; 1994:23-24.
    • (1994) Proc IEEE/EMBS Conference , pp. 23-24
    • Malkin, R.1    Compos, A.2    Raymond, L.3    Bernstein, R.4
  • 26
    • 10244253989 scopus 로고
    • Defibrillation efficacy estimation using Bayesian estimation theory
    • Malkin R, Pilkington T. Defibrillation efficacy estimation using Bayesian estimation theory. IEEE Trans Biomed Eng. 1993;179-182.
    • (1993) IEEE Trans Biomed Eng , pp. 179-182
    • Malkin, R.1    Pilkington, T.2
  • 27
    • 0024210171 scopus 로고
    • An up-down algorithm for estimation of the cardiac ventricular defibrillation threshold
    • McDaniel W, Schuder J. An up-down algorithm for estimation of the cardiac ventricular defibrillation threshold. Med Instrum. 1988;22:286-292.
    • (1988) Med Instrum , vol.22 , pp. 286-292
    • McDaniel, W.1    Schuder, J.2
  • 28
    • 58149369424 scopus 로고
    • Implantable cardioverters and defibrillators
    • Troup P. Implantable cardioverters and defibrillators. Curr Probl Cardiol. 1989;14:679-815.
    • (1989) Curr Probl Cardiol , vol.14 , pp. 679-815
    • Troup, P.1
  • 29
    • 85025401780 scopus 로고
    • On the intensity-time relations for stimulation by electric currents. I
    • Blair H. On the intensity-time relations for stimulation by electric currents. I. J Gen Physiol. 1932;15:709-729.
    • (1932) J Gen Physiol , vol.15 , pp. 709-729
    • Blair, H.1
  • 30
    • 33749948620 scopus 로고
    • On the intensity-time relations for stimulation by electric currents, II
    • Blair H. On the intensity-time relations for stimulation by electric currents, II. J Gen Physiol. 1932;15:731-755.
    • (1932) J Gen Physiol , vol.15 , pp. 731-755
    • Blair, H.1
  • 31
    • 0019206011 scopus 로고
    • Bipolar catheter defibrillation in dogs using trapezoidal waveforms of various tilts
    • Wessale J, Bourland J, Tacker W, Geddes L. Bipolar catheter defibrillation in dogs using trapezoidal waveforms of various tilts. J Electrocardiol. 1980;13:359-366.
    • (1980) J Electrocardiol , vol.13 , pp. 359-366
    • Wessale, J.1    Bourland, J.2    Tacker, W.3    Geddes, L.4
  • 32
    • 0342293176 scopus 로고
    • Strength duration curves for short time constant truncated exponential monophasic waveforms
    • Abstract
    • Walker R, Walcott G, Smith W, Ideker R. Strength duration curves for short time constant truncated exponential monophasic waveforms. Pacing Clin Electrophysiol. 1993;16:915. Abstract.
    • (1993) Pacing Clin Electrophysiol , vol.16 , pp. 915
    • Walker, R.1    Walcott, G.2    Smith, W.3    Ideker, R.4
  • 33
    • 0016506815 scopus 로고
    • Amplitude-duration relation for direct ventricular defibrillation with rectangular current pulses
    • Koning G, Schneider H, Hoelen A. Amplitude-duration relation for direct ventricular defibrillation with rectangular current pulses. Med Biol Eng. 1975;13:388-395.
    • (1975) Med Biol Eng , vol.13 , pp. 388-395
    • Koning, G.1    Schneider, H.2    Hoelen, A.3
  • 35
    • 0029431225 scopus 로고
    • Biphasic shocks induce more uniform repolarization than monophasic shocks in a cardiac cellular field excitation model
    • Soble E, Fischler M, Tung L. Biphasic shocks induce more uniform repolarization than monophasic shocks in a cardiac cellular field excitation model. IEEE Trans Biomed Eng. 1995;257-258.
    • (1995) IEEE Trans Biomed Eng , pp. 257-258
    • Soble, E.1    Fischler, M.2    Tung, L.3
  • 36
    • 0026547706 scopus 로고
    • Synchronized repolarization after defibrillation shocks: A possible component of the defibrillation process demonstrated by optical recordings in rabbit hearts
    • Dillon S. Synchronized repolarization after defibrillation shocks: a possible component of the defibrillation process demonstrated by optical recordings in rabbit hearts. Circulation. 1992;85:1865-1878.
    • (1992) Circulation , vol.85 , pp. 1865-1878
    • Dillon, S.1
  • 37
    • 0019230977 scopus 로고
    • Transthoracic ventricular defibrillation in the 100 kg calf with untruncated and truncated exponential stimuli
    • Schuder J, Gold J, Stoekle H, Granberg T, Dettmer J, Larwill M. Transthoracic ventricular defibrillation in the 100 kg calf with untruncated and truncated exponential stimuli. IEEE Trans Biomed Eng. 1980;27:37-43.
    • (1980) IEEE Trans Biomed Eng , vol.27 , pp. 37-43
    • Schuder, J.1    Gold, J.2    Stoekle, H.3    Granberg, T.4    Dettmer, J.5    Larwill, M.6
  • 38
    • 0342293175 scopus 로고
    • The effect of tilt on defibrillation efficacy
    • Abstract
    • Shorofsky S, Foster A, Gold M. The effect of tilt on defibrillation efficacy. J Am Coll Cardiol. 1994;23:86A. Abstract.
    • (1994) J Am Coll Cardiol , vol.23
    • Shorofsky, S.1    Foster, A.2    Gold, M.3
  • 39
    • 10244245470 scopus 로고
    • Sequential pulse defibrillation thresholds in man: Effect of pulse width variation
    • Abstract
    • Bardy G, Ivey T, Stewart R. Sequential pulse defibrillation thresholds in man: effect of pulse width variation. J Am Coll Cardiol. 1987;9:166A. Abstract.
    • (1987) J Am Coll Cardiol , vol.9
    • Bardy, G.1    Ivey, T.2    Stewart, R.3
  • 40
    • 10244239425 scopus 로고
    • Effect of phase 1 tilt on 90 μF biphasic defibrillation waveforms
    • Abstract
    • Hahn S, Heil J, Lin Y, Defus D, Lang D. Effect of phase 1 tilt on 90 μF biphasic defibrillation waveforms. Pacing Clin Electrophysiol. 1995;18:887. Abstract.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 887
    • Hahn, S.1    Heil, J.2    Lin, Y.3    Defus, D.4    Lang, D.5
  • 41
    • 10244257686 scopus 로고
    • Improved efficacy of a biphasic waveform employing a shorter first phase
    • Abstract
    • Hahn S, Heil J, Lin Y, Lang D. Improved efficacy of a biphasic waveform employing a shorter first phase. Circulation. 1994;90 (suppl I):I-228. Abstract.
    • (1994) Circulation , vol.90 , Issue.1 SUPPL.
    • Hahn, S.1    Heil, J.2    Lin, Y.3    Lang, D.4
  • 43
    • 0015063242 scopus 로고
    • Engineering and physiological consideration of direct capacitor-discharge ventricular defibrillation
    • Geddes L, Tacker W. Engineering and physiological consideration of direct capacitor-discharge ventricular defibrillation. Med Biol Eng. 1971;9:185-199.
    • (1971) Med Biol Eng , vol.9 , pp. 185-199
    • Geddes, L.1    Tacker, W.2
  • 44
    • 0025248802 scopus 로고
    • Conduction disturbance caused by high current density electric fields
    • Yabe S, Smith W, Daubert J, Wolf P, Rollins D, Ideker R. Conduction disturbance caused by high current density electric fields. Circ Res. 1990;66:1190-1203.
    • (1990) Circ Res , vol.66 , pp. 1190-1203
    • Yabe, S.1    Smith, W.2    Daubert, J.3    Wolf, P.4    Rollins, D.5    Ideker, R.6
  • 45
    • 0028120785 scopus 로고
    • Dysfunction and safety factor strength-duration curves for biphasic defibrillator waveforms
    • Jones JL, Milne KB. Dysfunction and safety factor strength-duration curves for biphasic defibrillator waveforms. Am J Physiol. 1994;266:H263-H271.
    • (1994) Am J Physiol , vol.266
    • Jones, J.L.1    Milne, K.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.