메뉴 건너뛰기




Volumn 9, Issue 8, 2007, Pages 651-656

Laser-assisted lead extraction: The European experience

Author keywords

Excimer; Extraction; ICD leads; Laser pacemaker leads; Ultraviolet

Indexed keywords

LIPID; PROTEIN;

EID: 34547945157     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eum098     Document Type: Article
Times cited : (122)

References (19)
  • 1
    • 0036380363 scopus 로고    scopus 로고
    • Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads
    • Esposito M, Kennergren C, Holmström N, Nilsson S, Eckerdal J, Thomsen R Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads. J Biomed Mater Res 2002; 63:548-58.
    • (2002) J Biomed Mater Res , vol.63 , pp. 548-558
    • Esposito, M.1    Kennergren, C.2    Holmström, N.3    Nilsson, S.4    Eckerdal, J.5    Thomsen, R.6
  • 3
    • 0030043470 scopus 로고    scopus 로고
    • Three-year experience with a stylet for lead extraction:a multicenter study
    • Alt E, Neuzner J, Binner L et al. Three-year experience with a stylet for lead extraction:a multicenter study. Pacing Clin Electrophysiol 1996; 19:18-25.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 18-25
    • Alt, E.1    Neuzner, J.2    Binner, L.3
  • 6
    • 0026017955 scopus 로고
    • Intravascular techniques for extraction of permanent pacemaker leads
    • Byrd CL, Schwartz SJ, Hedin N. Intravascular techniques for extraction of permanent pacemaker leads. J Thorac Cardiovasc Surg 1991;101 989-97.
    • (1991) J Thorac Cardiovasc Surg , vol.101 , pp. 989-997
    • Byrd, C.L.1    Schwartz, S.J.2    Hedin, N.3
  • 7
    • 0026800758 scopus 로고
    • Lead extraction. Indications and techniques
    • Byrd CL, Schwartz SJ, Hedin N. Lead extraction. Indications and techniques. Cardiol Clin 1992;10:735-48.
    • (1992) Cardiol Clin , vol.10 , pp. 735-748
    • Byrd, C.L.1    Schwartz, S.J.2    Hedin, N.3
  • 8
    • 0013607943 scopus 로고    scopus 로고
    • Lead extraction:TEn year experience
    • Byrd CL. Lead extraction:TEn year experience. Pacing Clin Electrophysiol 1997;4(Pt. 2):1110.
    • (1997) Pacing Clin Electrophysiol , vol.4 , Issue.PART. 2 , pp. 1110
    • Byrd, C.L.1
  • 10
    • 0026008588 scopus 로고
    • Development of a new technique for explantation of chronic transvenous pacemaker leads:fIve initial case studies
    • Goode LB, Byrd CL, Wilkoff BL et al. Development of a new technique for explantation of chronic transvenous pacemaker leads:fIve initial case studies. Biomed Instrum Technol 1991;25:50-3.
    • (1991) Biomed Instrum Technol , vol.25 , pp. 50-53
    • Goode, L.B.1    Byrd, C.L.2    Wilkoff, B.L.3
  • 11
  • 12
    • 0018929031 scopus 로고
    • Removal of infected entrapped pacemaker electrodes by continuous traction (author's transl)
    • Schmidt G, Wirtzfeld A, Himmler FC et al. Removal of infected entrapped pacemaker electrodes by continuous traction (author's transl). Dtsch Med Wochenschr 1980;105:1609-14.
    • (1980) Dtsch Med Wochenschr , vol.105 , pp. 1609-1614
    • Schmidt, G.1    Wirtzfeld, A.2    Himmler, F.C.3
  • 14
    • 0000277822 scopus 로고    scopus 로고
    • Clinical study of the laser sheath: Results of the PLEXES Trial
    • Byrd CL, Wilkoff BL, Love CJ et al. Clinical study of the laser sheath: Results of the PLEXES Trial. Pacing Clin Electrophysiol 1997;4(Pt. 2):1053.
    • (1997) Pacing Clin Electrophysiol , vol.4 , Issue.PART. 2 , pp. 1053
    • Byrd, C.L.1    Wilkoff, B.L.2    Love, C.J.3
  • 15
    • 0036090518 scopus 로고    scopus 로고
    • Clinical study of the laser sheath for lead extraction: The total experience in the United States
    • Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C. Clinical study of the laser sheath for lead extraction: The total experience in the United States. Pacing Clin Electrophysiol 2002;25:804-8.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 804-808
    • Byrd, C.L.1    Wilkoff, B.L.2    Love, C.J.3    Sellers, T.D.4    Reiser, C.5
  • 16
    • 0031983656 scopus 로고    scopus 로고
    • Large laser sheaths for pacing and defibrillator lead removal
    • Reiser C, Taylor KD, Lippincott RA. Large laser sheaths for pacing and defibrillator lead removal. Lasers Surg Med 1998;22:42-5.
    • (1998) Lasers Surg Med , vol.22 , pp. 42-45
    • Reiser, C.1    Taylor, K.D.2    Lippincott, R.A.3
  • 17
    • 0032814953 scopus 로고    scopus 로고
    • Excimer laser assisted extraction of permanent pacemaker and ICD leads:pResent experiences of a European multi-centre study
    • Kennergren C et al. Excimer laser assisted extraction of permanent pacemaker and ICD leads:pResent experiences of a European multi-centre study. Eur J Cardiothorac Surg 1999;15(6):856-60.
    • (1999) Eur J Cardiothorac Surg , vol.15 , Issue.6 , pp. 856-860
    • Kennergren, C.1
  • 18
    • 0031881567 scopus 로고    scopus 로고
    • First European experience using excimer laser for the extraction of permanent pacemaker leads
    • Kennergren C. First European experience using excimer laser for the extraction of permanent pacemaker leads. Pacing Clin Electrophysiol 1998;21:268-70.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 268-270
    • Kennergren, C.1
  • 19
    • 0031755323 scopus 로고    scopus 로고
    • Learning curve characteristics of pacing lead extraction with a laser sheath
    • Bracke FA, Meijer A, Van Gelder B. Learning curve characteristics of pacing lead extraction with a laser sheath. Pacing Clin Electrophysiol 1998;21:2309-13.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2309-2313
    • Bracke, F.A.1    Meijer, A.2    Van Gelder, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.