메뉴 건너뛰기




Volumn 12, Issue 3, 2010, Pages 385-388

Does defibrillation threshold increase as left ventricular ejection fraction decreases?

Author keywords

Defibrillation threshold; Ejection fraction; Implantable cardioverter defibrillator

Indexed keywords

AGED; ARTICLE; DEFIBRILLATION; DEFIBRILLATOR; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; WAVEFORM;

EID: 77749320077     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eup408     Document Type: Article
Times cited : (13)

References (22)
  • 1
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implantable defibrillator in patients with coronary disease at high risk for ventricular arrhythmia
    • Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H et al. Improved survival with an implantable defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med 1996;355:1933-40.
    • (1996) N Engl J Med , vol.355 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3    Daubert, J.P.4    Higgins, S.L.5    Klein, H.6
  • 3
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3    Klein, H.4    Wilber, D.J.5    Cannom, D.S.6
  • 4
    • 0037245915 scopus 로고    scopus 로고
    • High defibrillation thresholds in transvenous biphasic implantable defibrillators: Clinical predictors and prognostic implications
    • Shukla HH, Flaker GC, Jayam V, Roberts D. High defibrillation thresholds in transvenous biphasic implantable defibrillators: clinical predictors and prognostic implications. PACE 2003;26:44-8.
    • (2003) PACE , vol.26 , pp. 44-48
    • Shukla, H.H.1    Flaker, G.C.2    Jayam, V.3    Roberts, D.4
  • 5
    • 0027176206 scopus 로고
    • Predictors of defibrillation efficacy in patients undergoing epicardial defibrillator implantation: The multicenter Pacemaker-Cardioverter-Defibrillator (PCD) Investigators Group
    • Leitch JW, Yee R. Predictors of defibrillation efficacy in patients undergoing epicardial defibrillator implantation: the multicenter Pacemaker-Cardioverter-Defibrillator (PCD) Investigators Group. J Am Coll Cardiol 1993;21:632-1637.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 632-1637
    • Leitch, J.W.1    Yee, R.2
  • 6
    • 0029032493 scopus 로고
    • Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system
    • Raitt MH, Johnson G, Dolack GL, Poole JE, Kudenchuk PJ, Bardy GH. Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system. J Am Coll Cardiol 1995;25:1576- 83.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1576-1583
    • Raitt, M.H.1    Johnson, G.2    Dolack, G.L.3    Poole, J.E.4    Kudenchuk, P.J.5    Bardy, G.H.6
  • 7
    • 18044362735 scopus 로고    scopus 로고
    • Clinical predictors of defibrillation threshold in patients with implantable cardioverter-defibrillators
    • Lubinski A, Lewicka-Nowak E, Zienciuk A, Krolak T, Kempa M, Pazdyga A et al. Clinical predictors of defibrillation threshold in patients with implantable cardioverter-defibrillators. Kardiol Pol 2005;62:317- 28.
    • (2005) Kardiol Pol , vol.62 , pp. 317-328
    • Lubinski, A.1    Lewicka-Nowak, E.2    Zienciuk, A.3    Krolak, T.4    Kempa, M.5    Pazdyga, A.6
  • 8
    • 0025863246 scopus 로고
    • Patients with a high defibrillation threshold: Clinical characteristics, management, and outcome
    • Pinski SL, Vanerio G, Castle LW, Morant VA, Simmons TW, Trohman RG et al. Patients with a high defibrillation threshold: clinical characteristics, management, and outcome. Am Heart J 1991;122:89-95.
    • (1991) Am Heart J , vol.122 , pp. 89-95
    • Pinski, S.L.1    Vanerio, G.2    Castle, L.W.3    Morant, V.A.4    Simmons, T.W.5    Trohman, R.G.6
  • 9
    • 33846290710 scopus 로고    scopus 로고
    • Fixed duration 'tuned' defibrillation waveforms outperform fixed 50/50% tilt defibrillation waveforms: A randomized, prospective, pair-sampled multicenter study
    • Natarajan S, Henthorn R, Burroughs J, Esberg D, Zweibel S, Ross T et al. Fixed duration 'tuned' defibrillation waveforms outperform fixed 50/50% tilt defibrillation waveforms: a randomized, prospective, pair-sampled multicenter study. Pacing Clin Electrophysiol 2007;30:S139-S142.
    • (2007) Pacing Clin Electrophysiol , vol.30
    • Natarajan, S.1    Henthorn, R.2    Burroughs, J.3    Esberg, D.4    Zweibel, S.5    Ross, T.6
  • 10
    • 39649098463 scopus 로고    scopus 로고
    • Optimization of superior vena cava coil position and usage for transvenous defibrillation
    • Gold MR, Val-Mejias J, Leman RB, Tummala R, Goyal S, Kluger J et al. Optimization of superior vena cava coil position and usage for transvenous defibrillation. Heart Rhythm 2008;5:394-9.
    • (2008) Heart Rhythm , vol.5 , pp. 394-399
    • Gold, M.R.1    Val-Mejias, J.2    Leman, R.B.3    Tummala, R.4    Goyal, S.5    Kluger, J.6
  • 11
    • 77749299360 scopus 로고    scopus 로고
    • Efficacy of tuned waveforms based on different membrane time constants on defibrillation thresholds: Primary results from the POWER trial
    • Doshi S, Val-Mejias JE, Pittaro M, Reeves R, Boyce K, Payne J et al. Efficacy of tuned waveforms based on different membrane time constants on defibrillation thresholds: primary results from the POWER trial. Europace 2008;10:i100.
    • (2008) Europace , vol.10 , Issue.I100
    • Doshi, S.1    Val-Mejias, J.E.2    Pittaro, M.3    Reeves, R.4    Boyce, K.5    Payne, J.6
  • 13
    • 77749342762 scopus 로고    scopus 로고
    • Defibrillation thresholds in patients with cardiac resynchronization therapy defibrillators
    • Burke SW, Sturdivant LJ, Leman RB, Wharton MJ, Gold MR. Defibrillation thresholds in patients with cardiac resynchronization therapy defibrillators. Heart Rhythm 2006;3:S165.
    • (2006) Heart Rhythm , vol.3
    • Burke, S.W.1    Sturdivant, L.J.2    Leman, R.B.3    Wharton, M.J.4    Gold, M.R.5
  • 15
    • 25444506295 scopus 로고    scopus 로고
    • Do biventricular pacemaker defibrillators patients have higher defibrillation thresholds?
    • Doshi RN, Crandall BG, Osborn JS, Weiss P, Kfoury A, Wang S et al. Do biventricular pacemaker defibrillators patients have higher defibrillation thresholds? Heart Rhythm 2005;2:S243.
    • (2005) Heart Rhythm , vol.2
    • Doshi, R.N.1    Crandall, B.G.2    Osborn, J.S.3    Weiss, P.4    Kfoury, A.5    Wang, S.6
  • 16
    • 77749299358 scopus 로고    scopus 로고
    • Val-Mejias JE, Gold M, Natarajan S, Oza A. Is there a difference in defibrillation thresholds between patients with primary vs. secondary prevention indications? Europace Suppl 2007;9:iii186.
    • Val-Mejias JE, Gold M, Natarajan S, Oza A. Is there a difference in defibrillation thresholds between patients with primary vs. secondary prevention indications? Europace Suppl 2007;9:iii186.
  • 18
    • 20244387585 scopus 로고    scopus 로고
    • Defibrillation threshold testing: Is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    • Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM et al. Defibrillation threshold testing: Is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm 2005;2:456-61.
    • (2005) Heart Rhythm , vol.2 , pp. 456-461
    • Russo, A.M.1    Sauer, W.2    Gerstenfeld, E.P.3    Hsia, H.H.4    Lin, D.5    Cooper, J.M.6
  • 20
    • 33747826289 scopus 로고    scopus 로고
    • Elevated defibrillation thresholds in patients undergoing biventricular defibrillator implantation: Incidence and predictors
    • Mainigi SK, Cooper JM, Russo AM, Nayak HM, Lin D, Dixit S et al. Elevated defibrillation thresholds in patients undergoing biventricular defibrillator implantation: incidence and predictors. Heart Rhythm 2006;3:1010-6.
    • (2006) Heart Rhythm , vol.3 , pp. 1010-1016
    • Mainigi, S.K.1    Cooper, J.M.2    Russo, A.M.3    Nayak, H.M.4    Lin, D.5    Dixit, S.6
  • 22
    • 33646006070 scopus 로고    scopus 로고
    • Benefit of millisecond waveform durations for patients with high defibrillation thresholds
    • Denman RA, Umesan C, Martin PT, Forbes RN, Kroll MW, Anskey EJ et al. Benefit of millisecond waveform durations for patients with high defibrillation thresholds. Heart Rhythm 2006;3:536-41.
    • (2006) Heart Rhythm , vol.3 , pp. 536-541
    • Denman, R.A.1    Umesan, C.2    Martin, P.T.3    Forbes, R.N.4    Kroll, M.W.5    Anskey, E.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.