Distal Right Ventricular Coil Position Reduces Defibrillation Thresholds

Author keywords

Defibrillation threshold; Implantable cardioverter defibrillator

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COHORT ANALYSIS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEFIBRILLATION; DEFIBRILLATOR; ELECTRIC CURRENT; ELECTRIC POTENTIAL; ELECTRODE; ENERGY RESOURCE; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART RIGHT VENTRICLE; HEART VENTRICLE FIBRILLATION; HUMAN; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZATION; RANDOMIZED CONTROLLED TRIAL; SEX DIFFERENCE; SUPERIOR CAVA VEIN;

EID: 0242719735     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8167.2003.03205.x     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic drug therapy with implantable defibrillator in patients resuscitated from near fatal ventricular arrhythmias
    • The Antiarrhythmics Versus Implantable Defibrillators (AVID) Investigators: A comparison of antiarrhythmic drug therapy with implantable defibrillator in patients resuscitated from near fatal ventricular arrhythmias. N Engl J Med 1997;337:1576-1583.
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 3
    • 0033576804 scopus 로고    scopus 로고
    • A randomized study of the prevention of sudden death in patients with coronary artery disease
    • Multicenter Unsustained Tachycardia Trial Investigators
    • Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G: A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med 1999;341:1882-1890.
    • (1999) N Engl J Med , vol.341 , pp. 1882-1890
    • Buxton, A.E.1    Lee, K.L.2    Fisher, J.D.3    Josephson, M.E.4    Prystowsky, E.N.5    Hafley, G.6
  • 5
    • 0031018040 scopus 로고    scopus 로고
    • A multicenter, randomized trial comparing an active can implantable defibrillator with a passive can system
    • Jewel Active Can Investigators.
    • Haffajee C, Martin D, Bhandari A, Bardy GH, DeSouza C, Kuehlkamp V, Church T: A multicenter, randomized trial comparing an active can implantable defibrillator with a passive can system. Jewel Active Can Investigators. Pacing Clin Electrophysiol 1997;20:215-219.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 215-219
    • Haffajee, C.1    Martin, D.2    Bhandari, A.3    Bardy, G.H.4    DeSouza, C.5    Kuehlkamp, V.6    Church, T.7
  • 6
    • 0030237562 scopus 로고    scopus 로고
    • Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system
    • Gold MR, Foster AH, Shorofsky SR: Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system. Am J Cardiol 1996;78:540-543.
    • (1996) Am J Cardiol , vol.78 , pp. 540-543
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 9
    • 0031945621 scopus 로고    scopus 로고
    • Effect of shock polarity on biphasic defibrillation thresholds using an active pectoral lead system
    • Olsovsky MR, Shorofsky SR, Gold MR: Effect of shock polarity on biphasic defibrillation thresholds using an active pectoral lead system. J Cardiovasc Electrophysiol 1998;9:350-354.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 350-354
    • Olsovsky, M.R.1    Shorofsky, S.R.2    Gold, M.R.3
  • 11
    • 0026657534 scopus 로고
    • Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study
    • Epstein AE, Ellenbogen KA, Kirk KA, Kay GN, Dailey SM, Plumb VJ: Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study. Circulation 1992;86:1206-1216.
    • (1992) Circulation , vol.86 , pp. 1206-1216
    • Epstein, A.E.1    Ellenbogen, K.A.2    Kirk, K.A.3    Kay, G.N.4    Dailey, S.M.5    Plumb, V.J.6
  • 12
    • 0034881409 scopus 로고    scopus 로고
    • Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: Results from active can versus array trials I and II
    • Gradaus R, Block M, Seidl K, Brunn J, Isgro F, Hammel D, Hauer B, Breithardt G, Bocker D: Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: Results from active can versus array trials I and II. J Cardiovasc Electrophysiol 2001;12:921-927.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 921-927
    • Gradaus, R.1    Block, M.2    Seidl, K.3    Brunn, J.4    Isgro, F.5    Hammel, D.6    Hauer, B.7    Breithardt, G.8    Bocker, D.9
  • 13
    • 17144451468 scopus 로고    scopus 로고
    • Effect of a single element subcutaneous array electrode added to a transvenous electrode configuration on the defibrillation field and the defibrillation threshold
    • Kuhlkamp V, Dornberger V, Khalighi K, Mewis C, Suchalla R, Ziemer G, Seipel L: Effect of a single element subcutaneous array electrode added to a transvenous electrode configuration on the defibrillation field and the defibrillation threshold. Pacing Clin Electrophysiol 1998;21:2596-2605.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2596-2605
    • Kuhlkamp, V.1    Dornberger, V.2    Khalighi, K.3    Mewis, C.4    Suchalla, R.5    Ziemer, G.6    Seipel, L.7
  • 14
    • 0242597359 scopus 로고    scopus 로고
    • Effect of RV electrode position on ventricular DFTs by finite element analysis in a human thorax model
    • Min X, Mehra R: Effect of RV electrode position on ventricular DFTs by finite element analysis in a human thorax model. Pacing Clin Electrophysiol 1997;20:1149.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 1149
    • Min, X.1    Mehra, R.2
  • 16
    • 0028919682 scopus 로고
    • Implantable cardioverter defibrillator lead technology: Improved performance and lower defibrillation thresholds
    • Lang DJ, Heil JE Hahn SJ, Lindstrom CC, Derfus DL: Implantable cardioverter defibrillator lead technology: Improved performance and lower defibrillation thresholds. Pacing Clin Electrophysiol 1995;18:548-559.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 548-559
    • Lang, D.J.1    Heil, J.E.2    Hahn, S.J.3    Lindstrom, C.C.4    Derfus, D.L.5
  • 18
    • 0032192087 scopus 로고    scopus 로고
    • Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study
    • Winter J, Heil JE, Schumann C, Lin Y, Schannwell CM, Michel U, Schipke JD, Schulte HD, Gams E: Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study. Eur J Cardiothoracic Surg 1998;14:419-425.
    • (1998) Eur J Cardiothoracic Surg , vol.14 , pp. 419-425
    • Winter, J.1    Heil, J.E.2    Schumann, C.3    Lin, Y.4    Schannwell, C.M.5    Michel, U.6    Schipke, J.D.7    Schulte, H.D.8    Gams, E.9
  • 19
    • 0000455715 scopus 로고
    • Sensing strategies dramatically affect defibrillation efficacy of endocardial based lead systems in swine
    • Heil JE, Kenknight BH, Derfus DL, Lang DJ: Sensing strategies dramatically affect defibrillation efficacy of endocardial based lead systems in swine. Pacing Clin Electrophysiol 1994;17:785.
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 785
    • Heil, J.E.1    Kenknight, B.H.2    Derfus, D.L.3    Lang, D.J.4
  • 23
    • 0025860727 scopus 로고
    • Characterization of refractory period extension by transcardiac shock
    • Sweeney RJ, Gill RM, Reid PR: Characterization of refractory period extension by transcardiac shock. Circulation 1991;83:2057-2066.
    • (1991) Circulation , vol.83 , pp. 2057-2066
    • Sweeney, R.J.1    Gill, R.M.2    Reid, P.R.3
  • 24
    • 0034117903 scopus 로고    scopus 로고
    • Virtual electrodes and deexcitation: New insights into fibrillation induction and defibrillation
    • Efimov IR, Gray RA, Roth BJ: Virtual electrodes and deexcitation: New insights into fibrillation induction and defibrillation. J Cardiovasc Electrophysiol 2000;11:339-353.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 339-353
    • Efimov, I.R.1    Gray, R.A.2    Roth, B.J.3
  • 25
    • 0032482142 scopus 로고    scopus 로고
    • Virtual electrode-induced phase singularity: A basic mechanism of defibrillation failure
    • Efimov IR, Cheng YN, Van Wagoner DR, Mazgalev T, Tchou PJ: Virtual electrode-induced phase singularity: A basic mechanism of defibrillation failure. Circ Res 1998;82:918-925.
    • (1998) Circ Res , vol.82 , pp. 918-925
    • Efimov, I.R.1    Cheng, Y.N.2    Van Wagoner, D.R.3    Mazgalev, T.4    Tchou, P.J.5
  • 26
    • 0026877545 scopus 로고
    • Defibrillation threshold: Clinical utility and therapeutic implications
    • Singer I, Lang D: Defibrillation threshold: Clinical utility and therapeutic implications. Pacing Clin Electrophysiol 1992;15:932-949.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 932-949
    • Singer, I.1    Lang, D.2
  • 27
    • 0001913657 scopus 로고    scopus 로고
    • Testing of implantable defibrillator functions at implantation
    • Ellenbogen K, ed: Philadelphia: WB Saunders
    • Kroll MW, Tchou PJ: Testing of implantable defibrillator functions at implantation. In Ellenbogen K, ed: Clinical Cardiac Pacing and Defibrillation. Philadelphia: WB Saunders, 2000, pp. 540-561.
    • (2000) Clinical Cardiac Pacing and Defibrillation , pp. 540-561
    • Kroll, M.W.1    Tchou, P.J.2
  • 28
    • 0030041635 scopus 로고    scopus 로고
    • Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators. Prospective comparison of different lead system-device combinations
    • Natale A, Sra J, Axtell K, Akhtar M, Newby K, Kent V, Geiger MJ, Brandon MJ, Kearney MM, Pacifico A: Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators. Prospective comparison of different lead system-device combinations. Circulation 1996;93:91-98.
    • (1996) Circulation , vol.93 , pp. 91-98
    • Natale, A.1    Sra, J.2    Axtell, K.3    Akhtar, M.4    Newby, K.5    Kent, V.6    Geiger, M.J.7    Brandon, M.J.8    Kearney, M.M.9    Pacifico, A.10
  • 29
    • 0032802954 scopus 로고    scopus 로고
    • Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation
    • Cooklin M, Tummala RV, Peters RW, Shorofsky SR, Gold MR: Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation. Am Heart J 1999;138:133-136.
    • (1999) Am Heart J , vol.138 , pp. 133-136
    • Cooklin, M.1    Tummala, R.V.2    Peters, R.W.3    Shorofsky, S.R.4    Gold, M.R.5
  • 30
    • 0029098719 scopus 로고
    • Postshock sensing performance in transvenous defibrillation lead systems: Analysis of detection and redetection of ventricular fibrillation
    • Callans DJ, Swarna US, Schwartzman D, Gottlieb CD, Marchlinski FE: Postshock sensing performance in transvenous defibrillation lead systems: Analysis of detection and redetection of ventricular fibrillation. J Cardiovasc Electrophysiol 1995;6:613-615.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 613-615
    • Callans, D.J.1    Swarna, U.S.2    Schwartzman, D.3    Gottlieb, C.D.4    Marchlinski, F.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.