1
-
-
79952013841
-
An overview of matrix effects in liquid chromatography-mass spectrometry
-
nnReview of matrix effects covering their mechanistic causes, evaluation and avoidance
-
Trufelli H, Palma P, Famiglini G, Cappiello A. An overview of matrix effects in liquid chromatography-mass spectrometry. Mass Spectrom. Rev. 30, 491-509 (2011). nnReview of matrix effects covering their mechanistic causes, evaluation and avoidance.
-
(2011)
Mass Spectrom. Rev.
, vol.30
, pp. 491-509
-
-
Trufelli, H.1
Palma, P.2
Famiglini, G.3
Cappiello, A.4
-
2
-
-
12844276773
-
The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue analysis
-
Antignac JP, Wash F, Monteau HD, Brabander FA, Bizet BL. The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue analysis. Anal. Chim. Acta. 529, 129-136 (2005).
-
(2005)
Anal. Chim. Acta.
, vol.529
, pp. 129-136
-
-
Antignac, J.P.1
Wash, F.2
Monteau, H.D.3
Brabander, F.A.4
Bizet, B.L.5
-
3
-
-
79952020424
-
Matrix effect elimination during LC-MS/MS bioanalytical method development
-
nnReview of matrix effects with special emphasis on bioanalytical applications
-
Côté C, Bergeron A, Mess J-N, Furtado M, Garofolo F. Matrix effect elimination during LC-MS/MS bioanalytical method development. Bioanalysis. 1(7), 1243-1257 (2009). nnReview of matrix effects with special emphasis on bioanalytical applications.
-
(2009)
Bioanalysis
, vol.1
, Issue.7
, pp. 1243-1257
-
-
Côté, C.1
Bergeron, A.2
Mess, J-.N.3
Furtado, M.4
Garofolo, F.5
-
4
-
-
40649095122
-
Characterisation of serum albumin and lysoPCs as major contributors to plasma sample matrix effects on electrospray ionization efficiency
-
Montreal, Quebec, Canada, 8-12 June nnIdentified plasma phospholipids as a major cause of matrix effect
-
Ahnoff M, Wurzer A, Lindmark B, Jussila R. Characterisation of serum albumin and lysoPCs as major contributors to plasma sample matrix effects on electrospray ionization efficiency. Proceedings of: The 51st ASMS Conference on Mass Spectrometry and Allied Topics. Montreal, Quebec, Canada, 8-12 June 2003. nnIdentified plasma phospholipids as a major cause of matrix effect.
-
(2003)
Proceedings of: The 51st ASMS Conference on Mass Spectrometry and Allied Topics
-
-
Ahnoff, M.1
Wurzer, A.2
Lindmark, B.3
Jussila, R.4
-
5
-
-
75149115315
-
Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC/MS techniques
-
Salt Lake City, Utah, 26-30 October nnIdentified plasma phospholipids as a major cause of matrix effect
-
Bennett PK, Van Horne KC. Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC/MS techniques. Presented at: American Association of Pharmaceutical Scientists Conference. Salt Lake City, Utah, 26-30 October 2003. nnIdentified plasma phospholipids as a major cause of matrix effect.
-
(2003)
Presented at: American Association of Pharmaceutical Scientists Conference
-
-
Bennett, P.K.1
Van Horne, K.C.2
-
6
-
-
33645224920
-
Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma
-
nnSimple in-source collision-induced dissociation method to monitor glycerophophocholines by LC-MS
-
Little JL, Wempe MF, Buchanan CM. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma. J. Chromatogr. B 833, 219-230 (2006). nnSimple in-source collision-induced dissociation method to monitor glycerophophocholines by LC-MS.
-
(2006)
J. Chromatogr.
, vol.B 833
, pp. 219-230
-
-
Little, J.L.1
Wempe, M.F.2
Buchanan, C.M.3
-
7
-
-
67650357558
-
Phospholipids in liquid chromatography/mass spectrometry bioanalysis: Comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects
-
nnCompares relative merits of three methods for monitoring plasma phospholipids and explores the effect of mobile phase
-
Xia Y-Q, Jemal M. Phospholipids in liquid chromatography/mass spectrometry bioanalysis: Comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects. Rapid Commun. Mass Spectrom. 23, 2125-2138 (2009). nnCompares relative merits of three methods for monitoring plasma phospholipids and explores the effect of mobile phase.
-
(2009)
Rapid Commun. Mass Spectrom
, vol.23
, pp. 2125-2138
-
-
Xia, Y.-Q.1
Jemal, M.2
-
8
-
-
34249721558
-
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
-
DOI 10.1016/j.jchromb.2006.12.030, PII S1570023206010440
-
Chambers E, Wagrowski-Diehl DM, Lu Z, Mazzeo JR. Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses. J. Chromatogr. B 852, 22-34 (2007). (Pubitemid 46830084)
-
(2007)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
, vol.852
, Issue.1-2
, pp. 22-34
-
-
Chambers, E.1
Wagrowski-Diehl, D.M.2
Lu, Z.3
Mazzeo, J.R.4
-
9
-
-
79951750007
-
Garofolo. Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction conditions
-
nIdentified poor elution of phospholipids with 100% acetonitrile in silica-based SPE workflows.
-
Lahaie M, Mess J-N, Furtado M, Garofolo. Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction conditions. Bioanalysis 2(6), 1011-1021 (2010). nIdentified poor elution of phospholipids with 100% acetonitrile in silica-based SPE workflows.
-
(2010)
Bioanalysis
, vol.2
, Issue.6
, pp. 1011-1021
-
-
Lahaie, M.1
Mess, J-.N.2
Furtado, M.3
-
10
-
-
78650650170
-
Recent advances in sample preparation techniques for effective bioanalytical methods
-
Kole PL, Venkatesh G, Kotecha J, Sheshala R. Recent advances in sample preparation techniques for effective bioanalytical methods. Biomed. Chromatogr. 25, 199-217 (2011).
-
(2011)
Biomed. Chromatogr.
, vol.25
, pp. 199-217
-
-
Kole, P.L.1
Venkatesh, G.2
Kotecha, J.3
Sheshala, R.4
-
11
-
-
79960502740
-
Minimizing matrix effects while preserving throughput in LC-MS/MS bioanalysis
-
Ye Z, Tsao H, Gao H, Brummel CL. Minimizing matrix effects while preserving throughput in LC-MS/MS bioanalysis. Bioanalysis 3(14), 1587-1601 (2011).
-
(2011)
Bioanalysis
, vol.3
, Issue.14
, pp. 1587-1601
-
-
Ye, Z.1
Tsao, H.2
Gao, H.3
Brummel, C.L.4
-
12
-
-
84860283283
-
In silico prediction of retention times as a strategy to avoid matrix effects in LC-MS/MS bioanalysis
-
nUse of in silico techniques to predict phospholipid elution
-
Neville D. In silico prediction of retention times as a strategy to avoid matrix effects in LC-MS/MS bioanalysis. Chromatography Today 3(2), 18-20 (2010). nUse of in silico techniques to predict phospholipid elution.
-
(2010)
Chromatography Today
, vol.3
, Issue.2
, pp. 18-20
-
-
Neville, D.1
-
13
-
-
75149185863
-
Systematic LC-MS/MS bioanalytical method development that incorporates plasma phospholipids risk avoidance, usage of incurred sample and well thought-out chromatography
-
Jemal M, Ouyang Z, Xia Y-Q. Systematic LC-MS/MS bioanalytical method development that incorporates plasma phospholipids risk avoidance, usage of incurred sample and well thought-out chromatography. Biomed. Chromatogr. 24, 2-19 (2010).
-
(2010)
Biomed. Chromatogr.
, vol.24
, pp. 2-19
-
-
Jemal, M.1
Ouyang, Z.2
Xia, Y-.Q.3
-
14
-
-
79958110797
-
It is time for a paradigm shift in drug discovery bioanalysis: From SRM to HRMS
-
Ramanathan R, Jemal M, Ramagiri S et al. It is time for a paradigm shift in drug discovery bioanalysis: From SRM to HRMS. J. Mass. Spectrom. 46, 595-601 (2011).
-
(2011)
J. Mass. Spectrom.
, vol.46
, pp. 595-601
-
-
Ramanathan, R.1
Jemal, M.2
Ramagiri, S.3
-
15
-
-
17444400121
-
Solute attributes and molecular interactions contributing to "U-shape" retention on a fluorinated high-performance liquid chromatography stationary phase
-
DOI 10.1016/j.chroma.2004.08.163, 28th International Symposium on High Performance Liquid Separation and Related Techniques
-
Bell DS, Jones AD. Solute attributes and molecular interactions contributing to 'U-shape' retention on a fluorinated high-performance liquid chromatography stationary phase. J. Chromatogr. A 1073, 99-109 (2005). (Pubitemid 40544481)
-
(2005)
Journal of Chromatography A
, vol.1073
, Issue.1-2
, pp. 99-109
-
-
Bell, D.S.1
Jones, A.D.2
-
16
-
-
77956651593
-
Thermodynamic and kinetic characterization of a bridged-ethylene hybrid C18 stationary phase
-
Hupp AM, McGuffin VL. Thermodynamic and kinetic characterization of a bridged-ethylene hybrid C18 stationary phase. J. Chromatogr. A 1217, 6241-6249 (2010).
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 6241-6249
-
-
Hupp, A.M.1
McGuffin, V.L.2
-
17
-
-
53049083215
-
Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: Evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma
-
Wu ST, Schoener D, Jemal M. Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: Evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma. Rapid Commun. Mass Spectrom. 22, 2873-2881 (2008).
-
(2008)
Rapid Commun. Mass Spectrom.
, vol.22
, pp. 2873-2881
-
-
Wu, S.T.1
Schoener, D.2
Jemal, M.3
-
18
-
-
79959899638
-
Glycerophosphocholine molecular species profiling in the biological tissue using UPLC/MS/MS
-
Tang C-H, Tsao P-N, Chen C-Y, Shiao M-S, Wang W-H, Lin C-Y. Glycerophosphocholine molecular species profiling in the biological tissue using UPLC/MS/MS. J. Chromatogr. B 879, 2095-2106 (2011).
-
(2011)
J. Chromatogr. B
, vol.879
, pp. 2095-2106
-
-
Tang, C-.H.1
Tsao, P-.N.2
Chen, C-.Y.3
Shiao, M-.S.4
Wang, W-.H.5
Lin, C-.Y.6
-
19
-
-
0242681897
-
Comparison of the acidity of residual silanol groups in several liquid chromatography columns
-
DOI 10.1016/S0021-9673(02)01899-X, PII S002196730201899X
-
Méndez A, Bosch E, Rosés M, Neue UD. Comparison of the acidity of residual silanol groups in several liquid chromatography columns. J. Chromatogr. A 986, 33-44 (2003). (Pubitemid 36071532)
-
(2003)
Journal of Chromatography A
, vol.986
, Issue.1
, pp. 33-44
-
-
Mendez, A.1
Bosch, E.2
Roses, M.3
Neue, U.D.4
|