메뉴 건너뛰기




Volumn 1, Issue 7, 2009, Pages 1243-1257

Matrix effect elimination during LC - MS/MS bioanalytical method development

Author keywords

[No Author keywords available]

Indexed keywords

PROTEIN;

EID: 79952020424     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.09.117     Document Type: Review
Times cited : (118)

References (70)
  • 1
    • 0000648747 scopus 로고
    • Investigations of the electrospray interface for liquid chromatography/mass spectrometry
    • Ikonomou MG, Blades AT, Kebarle P. Investigations of the electrospray interface for liquid chromatography/mass spectrometry. Anal. Chem. 62, 957-967 (1990).
    • (1990) Anal. Chem. , vol.62 , pp. 957-967
    • Ikonomou, M.G.1    Blades, A.T.2    Kebarle, P.3
  • 2
    • 12044253267 scopus 로고
    • From ions in solution to ions in the gas phase - The mechanism of electrospray mass spectrometry
    • Kebarle P, Tang L. From ions in solution to ions in the gas phase -the mechanism of electrospray mass spectrometry. Anal. Chem. 65(22), 972A-986A (1993).
    • (1993) Anal. Chem. , vol.65 , Issue.22
    • Kebarle, P.1    Tang, L.2
  • 3
    • 0030298387 scopus 로고    scopus 로고
    • Quantification of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry. A study of ion suppression
    • Buhrman DL, Price PI, Rudewicz PJ. Quantification of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry. A study of ion suppression. J. Am. Soc. Mass. Spectrom. 7, 1099-1105 (1996).
    • (1996) J. Am. Soc. Mass. Spectrom. , vol.7 , pp. 1099-1105
    • Buhrman, D.L.1    Price, P.I.2    Rudewicz, P.J.3
  • 4
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski BK, Constanzer ML, Chavez-Eng CM. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal. Chem. 75(13), 3019-3030 (2003).
    • (2003) Anal. Chem. , vol.75 , Issue.13 , pp. 3019-3030
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 5
    • 14844313671 scopus 로고    scopus 로고
    • Matrix effects: The Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry
    • Taylor PJ. Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. Clin. Biochem. 38(4), 328-334 (2005).
    • (2005) Clin. Biochem. , vol.38 , Issue.4 , pp. 328-334
    • Taylor, P.J.1
  • 6
    • 67650133971 scopus 로고    scopus 로고
    • Validation of bioanalytical LC-MS/MS assays. Evaluation of matrix effects
    • Van Eeckhaut A, Lanckmans K, Sarre S, Smolders I, Michotte Y. Validation of bioanalytical LC-MS/MS assays. Evaluation of matrix effects. J. Chromatogr. B 877(23), 2198-2207 (2009).
    • (2009) J. Chromatogr. B , vol.877 , Issue.23 , pp. 2198-2207
    • Van Eeckhaut, A.1    Lanckmans, K.2    Sarre, S.3    Smolders, I.4    Michotte, Y.5
  • 7
    • 33947396093 scopus 로고    scopus 로고
    • Comparison of atmospheric pressure photoionization and atmospheric pressure chemical ionization for normal-phase LC/MS chiral analysis of pharmaceuticals
    • Cai S-S, Karl A. Hanold KA, Syage JA. Comparison of atmospheric pressure photoionization and atmospheric pressure chemical ionization for normal-phase LC/MS chiral analysis of pharmaceuticals. Anal. Chem. 79, 2491-2498 (2007).
    • (2007) Anal. Chem. , vol.79 , pp. 2491-2498
    • Cai, S.-S.1    Karl, A.2    Hanold, K.A.3    Syage, J.A.4
  • 8
    • 18144398163 scopus 로고    scopus 로고
    • Chiral liquid chromatography-tandem mass spectrometric methods for stereoisomeric pharmaceutical determinations
    • Chen J, Korfmacher WA, Hsieh Y. Chiral liquid chromatography-tandem mass spectrometric methods for stereoisomeric pharmaceutical determinations. J. Chromatogr. B 820, 1-8 (2005).
    • (2005) J. Chromatogr. B , vol.820 , pp. 1-8
    • Chen, J.1    Korfmacher, W.A.2    Hsieh, Y.3
  • 10
    • 36749115028 scopus 로고
    • On the evaporation of small ions from charged droplets
    • Iribarne JV, Thomson BA. On the evaporation of small ions from charged droplets. J. Chem. Phys. 64(6), 2287-2294 (1976).
    • (1976) J. Chem. Phys. , vol.64 , Issue.6 , pp. 2287-2294
    • Iribarne, J.V.1    Thomson, B.A.2
  • 12
    • 51249120304 scopus 로고    scopus 로고
    • State-of - The-art in atmospheric pressure photoionization for LC/MS
    • Robb DB, Blades MW. State-of-the-art in atmospheric pressure photoionization for LC/MS. Analytica Chimica Acta 627, 34-49 (2008).
    • (2008) Analytica Chimica Acta , vol.627 , pp. 34-49
    • Robb, D.B.1    Blades, M.W.2
  • 13
    • 58549107775 scopus 로고    scopus 로고
    • Atmospheric pressure photoionization for coupling liquid-chromatography to mass spectrometry. A review
    • Marchi I, Rudaz S, Veuthey J-L. Atmospheric pressure photoionization for coupling liquid-chromatography to mass spectrometry. A review. Talanta 78, 1-18 (2009).
    • (2009) Talanta , vol.78 , pp. 1-18
    • Marchi, I.1    Rudaz, S.2    Veuthey, J.-L.3
  • 14
    • 7244243966 scopus 로고    scopus 로고
    • Mechanism of [M+H]+ formation in photoionization mass spectrometry
    • Syage J. Mechanism of [M+H]+ formation in photoionization mass spectrometry. J. Am. Soc. Mass Spectrom. 15, 1521-1533 (2004).
    • (2004) J. Am. Soc. Mass Spectrom. , vol.15 , pp. 1521-1533
    • Syage, J.1
  • 15
    • 0023455726 scopus 로고
    • Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometry
    • Bruins AP, Covey TR, Henion JD. Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometry. Anal. Chem. 59, 2642-2646 (1967).
    • (1967) Anal. Chem. , vol.59 , pp. 2642-2646
    • Bruins, A.P.1    Covey, T.R.2    Henion, J.D.3
  • 16
    • 0034254295 scopus 로고    scopus 로고
    • Atmospheric pressure photoionization. An ionization method for liquid chromatography-mass spectrometry
    • Robb DB, Covey TR, Bruins AP. Atmospheric pressure photoionization. an ionization method for liquid chromatography-mass spectrometry. Anal. Chem. 72(15), 3653-3659 (2000).
    • (2000) Anal. Chem. , vol.72 , Issue.15 , pp. 3653-3659
    • Robb, D.B.1    Covey, T.R.2    Bruins, A.P.3
  • 17
    • 0032986050 scopus 로고    scopus 로고
    • The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds
    • Bonfiglio R, King RC, Olah TV, Merkle K. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun. Mass Spectrom. 13(12), 1175-1185 (1999).
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , Issue.12 , pp. 1175-1185
    • Bonfiglio, R.1    King, R.C.2    Olah, T.V.3    Merkle, K.4
  • 18
    • 30444448196 scopus 로고    scopus 로고
    • Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis
    • Matuszewski BK. Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis. J. Chromatogr. B 830(2), 293-300 (2006).
    • (2006) J. Chromatogr. B , vol.830 , Issue.2 , pp. 293-300
    • Matuszewski, B.K.1
  • 19
    • 75149115315 scopus 로고    scopus 로고
    • Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC/MS techniques
    • Salt Lake City, UT, USA 26-30 October
    • Bennett PK, Van Horne KC. Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC/MS techniques. Presented at: American Association of Pharmaceutical Scientists Conference. Salt Lake City, UT, USA, 26-30 October 2003.
    • (2003) American Association of Pharmaceutical Scientists Conference
    • Bennett, P.K.1    Van Horne, K.C.2
  • 20
    • 33645224920 scopus 로고    scopus 로고
    • Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies. Examining lipid matrix ionization effects in plasma
    • Little JL, Wempe MF, Buchanan CM. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies. Examining lipid matrix ionization effects in plasma. J. Chromatogr. B 833(2), 219-230 (2006).
    • (2006) J. Chromatogr. B , vol.833 , Issue.2 , pp. 219-230
    • Little, J.L.1    Wempe, M.F.2    Buchanan, C.M.3
  • 21
    • 67650357558 scopus 로고    scopus 로고
    • Phospholipids in liquid chromatography/mass spectrometry bioanalysis. Comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with the matrix effects
    • Xia YQ, Jemal M. Phospholipids in liquid chromatography/mass spectrometry bioanalysis. Comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with the matrix effects. Rapid Commun. Mass Spectrom. 23, 2125-2138 (2009).
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , pp. 2125-2138
    • Xia, Y.Q.1    Jemal, M.2
  • 22
    • 0032011562 scopus 로고    scopus 로고
    • Matrix effect in quantitative LC/MS/MS analyses of biological fluids. A method for determination of finasteride in human plasma at picogram per milliliter concentrations
    • Matuszewski BK, Constanzer ML, Chavez-Eng CM. Matrix effect in quantitative LC/MS/MS analyses of biological fluids. A method for determination of finasteride in human plasma at picogram per milliliter concentrations. Anal. Chem. 70(5), 882-889 (1998).
    • (1998) Anal. Chem. , vol.70 , Issue.5 , pp. 882-889
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 23
    • 8444250979 scopus 로고    scopus 로고
    • Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures
    • Souverain S, Rudaz S, Veuthey JL. Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures. J. Chromatogr. A 1058(1-2), 61-66 (2004).
    • (2004) J. Chromatogr. A , vol.1058 , Issue.1-2 , pp. 61-66
    • Souverain, S.1    Rudaz, S.2    Veuthey, J.L.3
  • 24
    • 0142195729 scopus 로고    scopus 로고
    • Matrix effect in bio-analysis of illicit drugs with LC-MS/MS. Influence of ionization type, sample preparation, and biofluid
    • Dams R, Huestis MA, Lambert WE, Murphy CM. Matrix effect in bio-analysis of illicit drugs with LC-MS/MS. influence of ionization type, sample preparation, and biofluid. J. Am. Soc. Mass Spectrom. 14(11), 1290-1294 (2003).
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , Issue.11 , pp. 1290-1294
    • Dams, R.1    Huestis, M.A.2    Lambert, W.E.3    Murphy, C.M.4
  • 25
    • 0037214121 scopus 로고    scopus 로고
    • Investigation of matrix effects in bioanalytical highperformance liquid chromatography-tandem mass spectrometric assays application to drug discovery
    • Mei H, Hsieh Y, Nardo C et al. Investigation of matrix effects in bioanalytical highperformance liquid chromatography-tandem mass spectrometric assays. application to drug discovery. Rapid Commun. Mass Spectrom. 17(1), 97-103 (2003).
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.1 , pp. 97-103
    • Mei, H.1    Hsieh, Y.2    Nardo, C.3
  • 26
    • 25144469720 scopus 로고    scopus 로고
    • A study of common discovery dosing formulation components and their potential for causing time-dependent matrix effects in highperformance liquid chromatography-tandem mass spectrometry assays
    • Xu X, Mei H, Wang S et al. A study of common discovery dosing formulation components and their potential for causing time-dependent matrix effects in highperformance liquid chromatography-tandem mass spectrometry assays. Rapid Commun. Mass Spectrom. 19(18), 2643-2650 (2005).
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , Issue.18 , pp. 2643-2650
    • Xu, X.1    Mei, H.2    Wang, S.3
  • 27
    • 0037073086 scopus 로고    scopus 로고
    • Atmospheric pressure photoionization liquid chromatographic-mass spectrometric determination of idoxifene and its metabolites in human plasma
    • Yang C, Henion J. Atmospheric pressure photoionization liquid chromatographic-mass spectrometric determination of idoxifene and its metabolites in human plasma. J. Chromatogr. A 970(1-2), 155-165 (2002).
    • (2002) J. Chromatogr. A , vol.970 , Issue.1-2 , pp. 155-165
    • Yang, C.1    Henion, J.2
  • 28
    • 0031793048 scopus 로고    scopus 로고
    • Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection
    • Fu I, Woolf EJ, Matuszewski BK. Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection. J. Pharm. Biomed. Anal. 18(3), 347-357 (1998).
    • (1998) J. Pharm. Biomed. Anal. , vol.18 , Issue.3 , pp. 347-357
    • Fu, I.1    Woolf, E.J.2    Matuszewski, B.K.3
  • 29
    • 33749329911 scopus 로고    scopus 로고
    • Moving from fast to ballistic gradient in liquid chromatography/tandem mass spectrometry pharmaceutical bioanalysis. Matrix effect and chromatographic evaluations
    • De Nardi C, Bonelli F. Moving from fast to ballistic gradient in liquid chromatography/tandem mass spectrometry pharmaceutical bioanalysis. Matrix effect and chromatographic evaluations. Rapid Commun. Mass Spectrom. 20(18), 2709-2716 (2006).
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , Issue.18 , pp. 2709-2716
    • De Nardi, C.1    Bonelli, F.2
  • 30
    • 0037234906 scopus 로고    scopus 로고
    • Post-column infusion study of the 'dosing vehicle effect' in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples
    • Shou WZ, Naidong W. Post-column infusion study of the 'dosing vehicle effect' in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples. Rapid Commun. Mass Spectrom. 17(6), 589-597 (2003).
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.6 , pp. 589-597
    • Shou, W.Z.1    Naidong, W.2
  • 31
    • 35448994851 scopus 로고    scopus 로고
    • Monitoring phospholipids for assessment of matrix effects in a liquid chromatography-tandem mass spectrometry method for hydrocodone and pseudoephedrine in human plasma
    • Ismaiel OA, Halquist MS, Elmamly MY, Shalaby A, Karnes HT. Monitoring phospholipids for assessment of matrix effects in a liquid chromatography-tandem mass spectrometry method for hydrocodone and pseudoephedrine in human plasma. J. Chromatogr. B 859(1), 84-93 (2007).
    • (2007) J. Chromatogr. B , vol.859 , Issue.1 , pp. 84-93
    • Ismaiel, O.A.1    Halquist, M.S.2    Elmamly, M.Y.3    Shalaby, A.4    Karnes, H.T.5
  • 32
    • 34249721558 scopus 로고    scopus 로고
    • Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
    • Chambers E, Wagrowski-Diehl DM, Lu Z, Mazzeo JR. Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses. J. Chromatogr. B 852(1-2), 22-34 (2007).
    • (2007) J. Chromatogr. B , vol.852 , Issue.1-2 , pp. 22-34
    • Chambers, E.1    Wagrowski-Diehl, D.M.2    Lu, Z.3    Mazzeo, J.R.4
  • 33
    • 84906657454 scopus 로고    scopus 로고
    • Effect of pH on the quantification and ion suppression of basic drugs in samples of biological origin by RP LC-ESI+-MS/MS
    • Denver, CO, USA, 1-5 June
    • Farkas T, Peng L. Effect of pH on the quantification and ion suppression of basic drugs in samples of biological origin by RP LC-ESI+-MS/MS. Presented at: 56th American Society for Mass Spectrometry Conference. Denver, CO, USA, 1-5 June 2008.
    • (2008) 56th American Society for Mass Spectrometry Conference
    • Farkas, T.1    Peng, L.2
  • 34
    • 42749093674 scopus 로고    scopus 로고
    • Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters
    • Van de Steene JC, Lambert WE. Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters. J. Am. Soc. Mass Spectrom. 19(5), 713-718 (2008).
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , Issue.5 , pp. 713-718
    • Van De Steene, J.C.1    Lambert, W.E.2
  • 35
    • 84906657464 scopus 로고    scopus 로고
    • Effect of sample preparation and chromatographic separation on matrix effects in quantitative bioanalysis
    • York, UK, 4-7 September
    • Gibb I, Sprake E, Preece S. Effect of sample preparation and chromatographic separation on matrix effects in quantitative bioanalysis. Presented at: British Mass Spectrometry Society 28th Annual Meeting. York, UK, 4-7 September 2005.
    • (2005) British Mass Spectrometry Society 28th Annual Meeting
    • Gibb, I.1    Sprake, E.2    Preece, S.3
  • 36
    • 84906657460 scopus 로고    scopus 로고
    • Ultra low level endogenous peptide quantitation using two-dimensional reverse-phase/normal-phase LC-LC-MS/MS
    • Merrimac, WI, USA, 9-13 July
    • Grant RP, Wagner AD. Ultra low level endogenous peptide quantitation using two-dimensional reverse-phase/normal-phase LC-LC-MS/MS. Presented at: 8th Land O'Lakes Bioanalytical Conference. Merrimac, WI, USA, 9-13 July 2007.
    • (2007) 8th Land O'Lakes Bioanalytical Conference
    • Grant, R.P.1    Wagner, A.D.2
  • 37
    • 0036006205 scopus 로고    scopus 로고
    • Different quantitation approaches for xenobiotics in human urine samples by liquid chromatography/electrospray tandem mass spectrometry
    • Sancho JV, Pozo OJ, López FJ, Hernández F. Different quantitation approaches for xenobiotics in human urine samples by liquid chromatography/electrospray tandem mass spectrometry. Rapid Commun. Mass Spectrom. 16(7), 639-645 (2002).
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , Issue.7 , pp. 639-645
    • Sancho, J.V.1    Pozo, O.J.2    López, F.J.3    Hernández, F.4
  • 38
    • 0034930266 scopus 로고    scopus 로고
    • LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices
    • Choi BK, Hercules DM, Gusev AI. LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices. Fresenius J. Anal. Chem. 369, 370-377 (2001).
    • (2001) Fresenius J. Anal. Chem. , vol.369 , pp. 370-377
    • Choi, B.K.1    Hercules, D.M.2    Gusev, A.I.3
  • 39
    • 77950787286 scopus 로고    scopus 로고
    • Selection of HILIC columns to handle matrix effect due to phospholipids
    • Mess JN, Côté C, Bergeron A, Furtado M, Garofolo F. Selection of HILIC columns to handle matrix effect due to phospholipids. Bioanalysis. 1(1), 57-62 (2009).
    • (2009) Bioanalysis. , vol.1 , Issue.1 , pp. 57-62
    • Mess, J.N.1    Côté, C.2    Bergeron, A.3    Furtado, M.4    Garofolo, F.5
  • 40
    • 84906707325 scopus 로고    scopus 로고
    • Comparison of diatomaceous earth liquid extraction versus liquid-liquid extraction for plasma assays using LC-MS/MS
    • Denver, CO, USA, 1-5 June
    • Brus TS. Comparison of diatomaceous earth liquid extraction versus liquid-liquid extraction for plasma assays using LC-MS/MS. Presented at: 56th American Society for Mass Spectrometry Conference. Denver, CO, USA, 1-5 June 2008.
    • (2008) 56th American Society for Mass Spectrometry Conference
    • Brus, T.S.1
  • 41
    • 34548132362 scopus 로고    scopus 로고
    • Minimizing matrix effects in the development of a method for the determination of salmeterol in human plasma by LC-MS/MS at low pg/ml concentration levels
    • Capka V, Carter SJ. Minimizing matrix effects in the development of a method for the determination of salmeterol in human plasma by LC-MS/MS at low pg/ml concentration levels. J. Chromatogr. B 856(1-2), 285-293 (2007).
    • (2007) J. Chromatogr. B , vol.856 , Issue.1-2 , pp. 285-293
    • Capka, V.1    Carter, S.J.2
  • 43
    • 84906690841 scopus 로고    scopus 로고
    • Selection of buffer additives for liquid-liquid extraction (LLE) procedure to remove matrix effect due to phospholipids
    • Philadelphy, PA, USA, 31 May-4, June
    • Bergeron M, Lahaie M, Furtado M, Garofolo F. Selection of buffer additives for liquid-liquid extraction (LLE) procedure to remove matrix effect due to phospholipids. Presented at: 57th American Society for Mass Spectrometry Conference. Philadelphy, PA, USA, 31 May-4 June 2009.
    • (2009) 57th American Society for Mass Spectrometry Conference
    • Bergeron, M.1    Lahaie, M.2    Furtado, M.3    Garofolo, F.4
  • 44
    • 84906690839 scopus 로고    scopus 로고
    • Impact of ion suppression by eliminating phospholipids interferences using a generic Turboflow method
    • Indianapolis, IN, USA, 3-7 June
    • Espourteille FA, LaFontaine C. Impact of ion suppression by eliminating phospholipids interferences using a generic Turboflow method. Presented at: 55th American Society for Mass Spectrometry Conference. Indianapolis, IN, USA, 3-7 June 2007.
    • (2007) 55th American Society for Mass Spectrometry Conference
    • Espourteille, F.A.1    Lafontaine, C.2
  • 45
    • 23044514946 scopus 로고    scopus 로고
    • Highthroughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry
    • Zhou S, Zhou H, Larson M et al. Highthroughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 19(15), 2144-2150 (2005).
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , Issue.15 , pp. 2144-2150
    • Zhou, S.1    Zhou, H.2    Larson, M.3
  • 46
    • 34249938957 scopus 로고    scopus 로고
    • Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS
    • Xu RN, Fan L, Rieser MJ, El-Shourbagy TA. Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS. J. Pharm. Biomed. Anal. 44(2), 342-355 (2007).
    • (2007) J. Pharm. Biomed. Anal. , vol.44 , Issue.2 , pp. 342-355
    • Xu, R.N.1    Fan, L.2    Rieser, M.J.3    El-Shourbagy, T.A.4
  • 47
    • 0033018785 scopus 로고    scopus 로고
    • High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings
    • Boos K-S, Grimm C-H. High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings. Trends Anal. Chem. 18(3), 175-180 (1999).
    • (1999) Trends Anal. Chem. , vol.18 , Issue.3 , pp. 175-180
    • Boos, K.-S.1    Grimm, C.-H.2
  • 48
    • 0034859372 scopus 로고    scopus 로고
    • Multidimensional on-line solid-phase extraction (SPE) using restricted access materials (RAM) in combination with molecular imprinted polymers (MIP)
    • Boos K-S, Fleisher CT. Multidimensional on-line solid-phase extraction (SPE) using restricted access materials (RAM) in combination with molecular imprinted polymers (MIP). Fresenius J. Anal. Chem. 371, 16-20 (2001).
    • (2001) Fresenius J. Anal. Chem. , vol.371 , pp. 16-20
    • Boos, K.-S.1    Fleisher, C.T.2
  • 49
    • 79953651190 scopus 로고    scopus 로고
    • Reduction of phospholipid matrix effects in electrospray ionization by adding colloidal silica and manganese(II) chloride
    • Seattle, WA, USA, 28 May-1, June
    • Schoener D, Noren M, Lehman J, Lin P. Reduction of phospholipid matrix effects in electrospray ionization by adding colloidal silica and manganese(II) chloride. Presented at: 54th American Society for Mass Spectrometry Conference. Seattle, WA, USA, 28 May-1 June 2006.
    • (2006) 54th American Society for Mass Spectrometry Conference
    • Schoener, D.1    Noren, M.2    Lehman, J.3    Lin, P.4
  • 50
    • 84906657458 scopus 로고    scopus 로고
    • Eliminating chromatography using high-throuphput electrophoretic sample preparation in quantitative bioanalysis
    • Denver, CO, USA 1-5 June
    • Grant RP, Holland P, Rappold B, Katz B, Norris J. Eliminating chromatography using high-throuphput electrophoretic sample preparation in quantitative bioanalysis. Presented at: 56th American Society for Mass Spectrometry Conference. Denver, CO, USA, 1-5 June 2008.
    • (2008) 56th American Society for Mass Spectrometry Conference
    • Grant, R.P.1    Holland, P.2    Rappold, B.3    Katz, B.4    Norris, J.5
  • 51
    • 70349163904 scopus 로고    scopus 로고
    • A novel strategy for reducing phospholipids-based matrix effect in LC-ESI-MS bioanalysis by means of HybridSPE
    • DOI: 10.1016/j.jpba.2009.05.037, Epub ahead of print
    • Pucci V, Di Palma S, Alfieri A, Bonelli F, Monteagudo E. A novel strategy for reducing phospholipids-based matrix effect in LC-ESI-MS bioanalysis by means of HybridSPE. J. Pharm. Biomed. Anal. DOI: 10.1016/j.jpba.2009.05.037 (2009) (Epub ahead of print).
    • (2009) J. Pharm. Biomed. Anal.
    • Pucci, V.1    Di Palma, S.2    Alfieri, A.3    Bonelli, F.4    Monteagudo, E.5
  • 52
    • 84906690840 scopus 로고    scopus 로고
    • A unique filtration device for matrix interference removal and reduction of ion-suppression in protein precipitated plasma samples
    • New Orleans, LA, USA 1-7 March
    • Jones D, Stubbs R. A unique filtration device for matrix interference removal and reduction of ion-suppression in protein precipitated plasma samples. Presented at: Pittcon Conference. New Orleans, LA, USA, 1-7 March 2008.
    • (2008) Pittcon Conference
    • Jones, D.1    Stubbs, R.2
  • 54
    • 84906657459 scopus 로고    scopus 로고
    • Efficiency, reproducibility, accuracy and linearity evaluation of filtration plates during protein precipitation to remove phospholipids in bioanalysis by LC-MS/MS
    • Philadelphia, PA, USA, 31 May-4, June
    • Dicaire C, Furtado M, Garofolo F. Efficiency, reproducibility, accuracy and linearity evaluation of filtration plates during protein precipitation to remove phospholipids in bioanalysis by LC-MS/MS. Presented at: 57th American Society for Mass Spectrometry Conference. Philadelphia, PA, USA, 31 May-4 June 2009.
    • (2009) 57th American Society for Mass Spectrometry Conference
    • Dicaire, C.1    Furtado, M.2    Garofolo, F.3
  • 56
    • 53049083215 scopus 로고    scopus 로고
    • Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: Evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma
    • Wu ST, Schoener D, Jemal M. Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma. Rapid Commun. Mass Spectrom. 22, 2873-2881 (2008).
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , pp. 2873-2881
    • Wu, S.T.1    Schoener, D.2    Jemal, M.3
  • 57
    • 0037257041 scopus 로고    scopus 로고
    • Application of co-eluting structural analog internal standards for expanded linear dynamic range in liquid chromatography/electrospray mass spectrometry
    • Shi G. Application of co-eluting structural analog internal standards for expanded linear dynamic range in liquid chromatography/electrospray mass spectrometry. Rapid Commun. Mass Spectrom. 17(3), 202-206 (2003).
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.3 , pp. 202-206
    • Shi, G.1
  • 58
    • 13444293453 scopus 로고    scopus 로고
    • Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: Necessity or not?
    • Stokvis E, Rosing H, Beijnen JH. Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not? Rapid Commun. Mass Spectrom. 19(3), 401-407 (2005).
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , Issue.3 , pp. 401-407
    • Stokvis, E.1    Rosing, H.2    Beijnen, J.H.3
  • 59
    • 33947724473 scopus 로고    scopus 로고
    • Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry
    • Lanckmans K, Sarre S, Smolders I, Michotte Y. Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 21(7), 1187-1195 (2007).
    • (2007) Rapid Commun. Mass Spectrom. , vol.21 , Issue.7 , pp. 1187-1195
    • Lanckmans, K.1    Sarre, S.2    Smolders, I.3    Michotte, Y.4
  • 60
    • 0043270582 scopus 로고    scopus 로고
    • Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: Method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard
    • Jemal M, Schuster A, Whigan DB. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard. Rapid Commun. Mass Spectrom. 17(15), 1723-1734 (2003).
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.15 , pp. 1723-1734
    • Jemal, M.1    Schuster, A.2    Whigan, D.B.3
  • 61
    • 4344625870 scopus 로고    scopus 로고
    • A study of matrix effects on an LC-MS/MS assay for olanzapine and desmethyl olanzapine
    • Chin C, Zhang ZP, Karnes HT. A study of matrix effects on an LC-MS/MS assay for olanzapine and desmethyl olanzapine. J. Pharm. Biomed. Anal. 35(5), 1149-1167 (2004).
    • (2004) J. Pharm. Biomed. Anal. , vol.35 , Issue.5 , pp. 1149-1167
    • Chin, C.1    Zhang, Z.P.2    Karnes, H.T.3
  • 62
    • 33845761419 scopus 로고    scopus 로고
    • Does a stable isotopically labeled internal standard always correct analyte response? A matrix effect study on a LC-MS/MS method for the determination of carvedilol enantiomers in human plasma
    • Wang S, Cyronak M, Yang E. Does a stable isotopically labeled internal standard always correct analyte response? A matrix effect study on a LC-MS/MS method for the determination of carvedilol enantiomers in human plasma. J. Pharm. Biomed. Anal. 43(2), 701-707 (2007).
    • (2007) J. Pharm. Biomed. Anal. , vol.43 , Issue.2 , pp. 701-707
    • Wang, S.1    Cyronak, M.2    Yang, E.3
  • 63
    • 38649118495 scopus 로고    scopus 로고
    • Development and validation of a liquid chromatographic-tandem mass spectrometric method for determination of piperaquine in plasma stable isotope labeled internal standard does not always compensate for matrix effects
    • Lindegardh N, Annerberg A, White NJ, Day NP. Development and validation of a liquid chromatographic-tandem mass spectrometric method for determination of piperaquine in plasma stable isotope labeled internal standard does not always compensate for matrix effects. J. Chromatogr. B. 862(1-2), 227-236 (2008).
    • (2008) J. Chromatogr. B. , vol.862 , Issue.1-2 , pp. 227-236
    • Lindegardh, N.1    Annerberg, A.2    White, N.J.3    Day, N.P.4
  • 64
    • 0036160015 scopus 로고    scopus 로고
    • High-performance liquid chromatographic-tandem mass spectrometric evaluation and determination of stable isotope labeled analogs of rofecoxib in human plasma samples from oral bioavailability studies
    • Chavez-Eng CM, Constanzer ML, Matuszewski BK. High-performance liquid chromatographic-tandem mass spectrometric evaluation and determination of stable isotope labeled analogs of rofecoxib in human plasma samples from oral bioavailability studies. J. Chromatogr. B 767(1), 117-129 (2002).
    • (2002) J. Chromatogr. B , vol.767 , Issue.1 , pp. 117-129
    • Chavez-Eng, C.M.1    Constanzer, M.L.2    Matuszewski, B.K.3
  • 65
    • 84855746886 scopus 로고    scopus 로고
    • Managing phospholipid-based matrix effects in bioanalysis
    • Prague, Czech Republic, 27 August-1, September
    • Bennett PK, Meng M, Capka V. Managing phospholipid-based matrix effects in bioanalysis. Presented at: 17th International Mass Spectrometry Conference. Prague, Czech Republic, 27 August-1 September 2006.
    • (2006) 17th International Mass Spectrometry Conference
    • Bennett, P.K.1    Meng, M.2    Capka, V.3
  • 66
    • 84906657455 scopus 로고    scopus 로고
    • AAPS workshop/conference report -quantitative bioanalytical methods validation and implementation, Best practices for chromatographic and ligand binding assays
    • AAPS workshop/conference report -quantitative bioanalytical methods validation and implementation. Best practices for chromatographic and ligand binding assays 2007 www.aapsj.org/articles/aapsj0901/aapsj0901004/aapsj0901004. pdf
    • (2007)
  • 67
    • 84906657456 scopus 로고    scopus 로고
    • Applied Biosystems
    • Applied Biosystems www.appliedbiosystems.com
  • 68
    • 84906657457 scopus 로고    scopus 로고
    • Thermo Fisher Scientific Inc.
    • Thermo Fisher Scientific Inc. www.thermo.com
  • 69
    • 84906674047 scopus 로고    scopus 로고
    • Sigma-Aldrich Inc.
    • Sigma-Aldrich Inc. www.sigma-aldrich.com
  • 70
    • 84906707324 scopus 로고    scopus 로고
    • Varian Inc.
    • Varian Inc. www.varianinc.com


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.