-
1
-
-
12044253267
-
From ions in solution to ions in the gas phase - The mechanism of electrospray mass spectrometry
-
Kebarle P, Tang L. From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry. Anal. Chem. 65(22), 972A-986A (1993).
-
(1993)
Anal. Chem
, vol.65
, Issue.22
-
-
Kebarle, P.1
Tang, L.2
-
2
-
-
40649095122
-
Characterization of serum albumin and lysoPCs as major contributors to plasma sample matrix effects on electrospray ionisation efficiency
-
Montreal, Canada, 8-12 June
-
Ahnoff M, Wurzer A, Lindmark B, Jussila R. Characterization of serum albumin and lysoPCs as major contributors to plasma sample matrix effects on electrospray ionisation efficiency. Presented at: 51st American Society of Mass Spectrometry Conference. Montreal, Canada, 8-12 June 2003
-
(2003)
51st American Society of Mass Spectrometry Conference
-
-
Ahnoff, M.1
Wurzer, A.2
Lindmark, B.3
Jussila, R.4
-
3
-
-
75149115315
-
Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC-MS techniques
-
Salt Lake City, UT, USA, 26-30 October
-
Bennett PK, Van Horne KC. Identification of the major endogenous and persistent compounds in plasma, serum and tissue that cause matrix effects with electrospray LC-MS techniques. Presented at: American Association of Pharmaceutical Scientists Annual Meeting and Exposition. Salt Lake City, UT, USA, 26-30 October 2003
-
(2003)
American Association of Pharmaceutical Scientists Annual Meeting and Exposition
-
-
Bennett, P.K.1
Van Horne, K.C.2
-
4
-
-
79952020424
-
Matrix effect elimination during LC-MS/MS bioanalytical method development
-
Ct C, Bergeron A, Mess JN, Furtado M, Garofolo F. Matrix effect elimination during LC-MS/MS bioanalytical method development. Bioanalysis 1(7), 1243-1257 (2009
-
(2009)
Bioanalysis
, vol.1
, Issue.7
, pp. 1243-1257
-
-
Ct, C.1
Bergeron, A.2
Mess, J.N.3
Furtado, M.4
Garofolo, F.5
-
5
-
-
79953242803
-
Assessing the matrix effects of hemolyzed samples in bioanalysis
-
Hughes NC, Bajaj N, Fan J, Wong EYK. Assessing the matrix effects of hemolyzed samples in bioanalysis. Bioanalysis 1(6), 1057-1066, (2009).
-
(2009)
Bioanalysis
, vol.1
, Issue.6
, pp. 1057-1066
-
-
Hughes, N.C.1
Bajaj, N.2
Fan, J.3
Eyk, W.4
-
6
-
-
34249721558
-
Systematic and comprehensive strategy for reducing matrix effects in LC-MS/MS analyses
-
Chambers E, Wagrowski-Diehl DM, Lu Z, Mazzeo JR
-
Chambers E, Wagrowski-Diehl DM, Lu Z, Mazzeo JR. Systematic and comprehensive strategy for reducing matrix effects in LC-MS/MS analyses. J. Chromatogr B Analyt. Technol. Biomed. Life Sci. 852(1-2), 22-34 (2007
-
(2007)
J. Chromatogr B Analyt. Technol. Biomed. Life Sci.
, vol.852
, Issue.1-2
, pp. 22-34
-
-
-
7
-
-
13544272687
-
Minimization of ion suppression in LC-MS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE)
-
DOI 10.1016/j.jpba.2004.10.035
-
Shen JX, Motyka RJ, Roach JP, Hayes RN. Minimization of ion suppression in LC-MS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE). J. Pharma. Biomed. Anal. 37, 359-367 (2005). (Pubitemid 40222308)
-
(2005)
Journal of Pharmaceutical and Biomedical Analysis
, vol.37
, Issue.2
, pp. 359-367
-
-
Shen, J.X.1
Motyka, R.J.2
Roach, J.P.3
Hayes, R.N.4
-
8
-
-
70649090289
-
Strategy of accelerated method development for high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with mass spectrometry
-
Liu G, Snapp HM, Ji QC, Arnold ME. Strategy of accelerated method development for high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with mass spectrometry. Anal. Chem. 81(22), 9225-9232 (2009).
-
(2009)
Anal. Chem
, vol.81
, Issue.22
, pp. 9225-9232
-
-
Liu, G.1
Snapp, H.M.2
Ji, Q.C.3
Arnold, M.E.4
-
9
-
-
79951750007
-
Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction elution conditions
-
Lahaie M, Mess JN, Furtado M, Garofolo F. Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction elution conditions. Bioanalysis 2(6), 1011-1021 (2010).
-
(2010)
Bioanalysis
, vol.2
, Issue.6
, pp. 1011-1021
-
-
Lahaie, M.1
Mess, J.N.2
Furtado, M.3
Garofolo, F.4
-
10
-
-
79952516009
-
Bioanalytical solutions to acetonitrile shortages
-
Gao H, Williams J, Carrier S, Brummel CL. Bioanalytical solutions to acetonitrile shortages. Bioanalysis 2(9), 1627-1640 (2010).
-
(2010)
Bioanalysis
, vol.2
, Issue.9
, pp. 1627-1640
-
-
Gao, H.1
Williams, J.2
Carrier, S.3
Brummel, C.L.4
-
11
-
-
70349163904
-
A novel strategy for reducing phospholipids-based matrix effect in LC-ESI-MS bioanalysis by means of HybridSPE
-
Pucci V, Palma SD, Alfieri A, Bonelli F, Monteagudo E. A novel strategy for reducing phospholipids-based matrix effect in LC-ESI-MS bioanalysis by means of HybridSPE. J. Pharma. Biomed. Anal. 50(5), 867-871 (2009).
-
(2009)
J. Pharma. Biomed. Anal.
, vol.50
, Issue.5
, pp. 867-871
-
-
Pucci, V.1
Palma, S.D.2
Alfieri, A.3
Bonelli, F.4
Monteagudo, E.5
-
12
-
-
53049083215
-
Plasma phospholipids implicated in the matrix effect observed in liquid chromatography-tandem mass spectrometry bioanalysis: Evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma
-
Wu ST, Schoener D, Jemal M. Plasma phospholipids implicated in the matrix effect observed in liquid chromatography-tandem mass spectrometry bioanalysis: evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma. Rapid Commun. Mass Spectrom. 22, 2873-2881 (2008).
-
(2008)
Rapid Commun. Mass Spectrom
, vol.22
, pp. 2873-2881
-
-
Wu, S.T.1
Schoener, D.2
Jemal, M.3
-
13
-
-
84855746886
-
Managing phospholipid-based matrix effects in bioanalysis
-
Prague, Czech Republic, 27 August-1 September
-
Bennett PK, Meng M, Ĉápka V. Managing phospholipid-based matrix effects in bioanalysis. Presented at: 17th International Mass Spectrometry Conference. Prague, Czech Republic, 27 August-1 September 2006.
-
(2006)
17th International Mass Spectrometry Conference
-
-
Bennett, P.K.1
Meng, M.2
Ĉápka, V.3
-
14
-
-
33645224920
-
Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma
-
Little JL, Wempe MF, Buchanan CM. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: examining lipid matrix ionization effects in plasma. J. Chromatogr B Analyt. Technol. Biomed. Life Sci. 833(2), 219-230 (2006
-
(2006)
J. Chromatogr B Analyt. Technol. Biomed. Life Sci.
, vol.833
, Issue.2
, pp. 219-230
-
-
Little, J.L.1
Wempe, M.F.2
Buchanan, C.M.3
-
15
-
-
84859438514
-
Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluations
-
Ismaiel OA, Halquist MS, Elmamly MY, Shalaby A, Karnes HT. Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluations. J. Chromatogr B Analyt. Technol. Biomed. Life Sci. 875(2), 333-343 (2008).
-
(2008)
J. Chromatogr B Analyt. Technol. Biomed. Life Sci.
, vol.875
, Issue.2
, pp. 333-343
-
-
Ismaiel, O.A.1
Halquist, M.S.2
Elmamly, M.Y.3
Shalaby, A.4
Karnes, H.T.5
-
16
-
-
44749086986
-
Simultaneous determination and quantification of seven major phospholipid classes in human blood using normal-phase liquid chromatography coupled with electrospray mass spectrometry and the application in diabetes nephropathy
-
Pang LQ, Liang QL, Wang YM, Ping L, Luo GA. Simultaneous determination and quantification of seven major phospholipid classes in human blood using normal-phase liquid chromatography coupled with electrospray mass spectrometry and the application in diabetes nephropathy. J. Chromatogr B Analyt. Technol. Biomed. Life Sci. 869(1-2), 118-125 (2008).
-
(2008)
J. Chromatogr B Analyt. Technol. Biomed. Life Sci.
, vol.869
, Issue.1-2
, pp. 118-125
-
-
Pang, L.Q.1
Liang, Q.L.2
Wang, Y.M.3
Ping, L.4
Luo, G.A.5
-
17
-
-
67650357558
-
Phospholipids in liquid chromatography-mass spectrometry bioanalysis: Comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects
-
Xia YQ, Jemal M. Phospholipids in liquid chromatography-mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects. Rapid Commun. Mass Spectrom. 23, 2125-2138 (2009
-
(2009)
Rapid Commun. Mass Spectrom
, vol.23
, pp. 2125-2138
-
-
Xia, Y.Q.1
Jemal, M.2
-
18
-
-
37449010141
-
Comparison of different water-miscible solvents for the preparation of plasma and urine samples in metabolic profiling studies
-
Alzweiri M, Watson DG, Robertson C, Sills GJ, Parkinson JA. Comparison of different water-miscible solvents for the preparation of plasma and urine samples in metabolic profiling studies. Talanta 74(4), 1060-1065 (2008).
-
(2008)
Talanta
, vol.74
, Issue.4
, pp. 1060-1065
-
-
Alzweiri, M.1
Watson, D.G.2
Robertson, C.3
Sills, G.J.4
Parkinson, J.A.5
-
19
-
-
0345360170
-
Chapter 2. Basics of Separation
-
Snyder LR, Kirkland JJ, Glajch JL (Eds). John Wiley & Sons, Inc., USA. Page 24
-
Snyder LR, Kirkland JJ, Glajch JL. Chapter 2. Basics of Separation. In:Practical HPLC Method Development (Second Edition) . Snyder LR, Kirkland JJ, Glajch JL (Eds). John Wiley & Sons, Inc., USA. Page 24 (1997).
-
(1997)
Practical HPLC Method Development (Second Edition)
-
-
Snyder, L.R.1
Kirkland, J.J.2
Glajch, J.L.3
-
20
-
-
0036009111
-
Effects of flow rate on high-throughput quantitative analysis of protein-precipitated plasma using liquid chromatography/tandem mass spectrometry
-
DOI 10.1002/rcm.606
-
Murphy AT, Berna MJ, Holsapple JL, Ackermann BL. Effects of flow rate on high-throughput quantitative analysis of protein-precipitated plasma using liquid chromatography-tandem mass spectrometry. Rapid Commun. Mass Spectrom. 16, 537-543 (2002 (Pubitemid 34205045)
-
(2002)
Rapid Communications in Mass Spectrometry
, vol.16
, Issue.6
, pp. 537-543
-
-
Murphy, A.T.1
Berna, M.J.2
Holsapple, J.L.3
Ackermann, B.L.4
|