메뉴 건너뛰기




Volumn 4, Issue 5, 2012, Pages 501-510

Application of LC-high-resolution MS with 'intelligent' data mining tools for screening reactive drug metabolites

Author keywords

[No Author keywords available]

Indexed keywords

CLOZAPINE; DICLOFENAC; DRUG METABOLITE; GLUTATHIONE; MENTHOFURAN; PARACETAMOL; PULEGONE; TICLOPIDINE;

EID: 84858391360     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.12.5     Document Type: Review
Times cited : (16)

References (35)
  • 1
    • 79953314978 scopus 로고    scopus 로고
    • Managing the challenge of chemically reactive metabolites in drug development
    • nExcellent review on approaches for handling metabolic activation of drug candidates in drug development.
    • Park BK, Boobis A, Clarke S et al. Managing the challenge of chemically reactive metabolites in drug development. Nat. Rev. Drug Discov. 10(4), 292-306 (2011). nExcellent review on approaches for handling metabolic activation of drug candidates in drug development.
    • (2011) Nat. Rev. Drug Discov. , vol.10 , Issue.4 , pp. 292-306
    • Park, B.K.1    Boobis, A.2    Clarke, S.3
  • 2
    • 70349103856 scopus 로고    scopus 로고
    • A zone classification system for risk assessment of idiosyncratic drug toxicity using daily dose and covalent binding
    • nDemonstration of a potential correlation of the extent of covalent binding and daily dose with observed clinical toxicity.
    • Nakayama S, Atsumi R, Takakusa H et al. A zone classification system for risk assessment of idiosyncratic drug toxicity using daily dose and covalent binding. Drug Metab. Dispos. 37(9), 1970-1977 (2009). nDemonstration of a potential correlation of the extent of covalent binding and daily dose with observed clinical toxicity.
    • (2009) Drug Metab. Dispos. , vol.37 , Issue.9 , pp. 1970-1977
    • Nakayama, S.1    Atsumi, R.2    Takakusa, H.3
  • 3
    • 38949088196 scopus 로고    scopus 로고
    • Metabolism and toxicity of drugs. Two decades of progress in industrial drug metabolism
    • Baillie TA. Metabolism and toxicity of drugs. Two decades of progress in industrial drug metabolism. Chem. Res. Toxicol. 21(1), 129-137 (2008
    • (2008) Chem. Res. Toxicol. , vol.21 , Issue.1 , pp. 129-137
    • Baillie, T.A.1
  • 4
    • 1642281756 scopus 로고    scopus 로고
    • Drug-protein adducts: An industry perspective on minimizing the potential for drug bioactivation in drug discovery and development
    • nOverview of strategies for minimizing the potential for metabolic activation in drug discovery and development.
    • Evans DC, Watt AP, Nicoll-Griffith DA, Baillie TA. Drug-protein adducts: An industry perspective on minimizing the potential for drug bioactivation in drug discovery and development. Chem. Res. Toxicol. 17(1), 3-16 (2004). nOverview of strategies for minimizing the potential for metabolic activation in drug discovery and development.
    • (2004) Chem. Res. Toxicol. , vol.17 , Issue.1 , pp. 3-16
    • Evans, D.C.1    Watt, A.P.2    Nicoll-Griffith, D.A.3    Baillie, T.A.4
  • 5
    • 59649106977 scopus 로고    scopus 로고
    • Recent advances in applications of liquid chromatography-tandem mass spectrometry to the analysis of reactive drug metabolites
    • nExcellent review on the analtytical techniques for the screening of reactive drug metabolites by LC-MS/MS.
    • Ma S, Zhu M. Recent advances in applications of liquid chromatography-tandem mass spectrometry to the analysis of reactive drug metabolites. Chem. Biol. Interact. 179(1), 25-37 (2009). nExcellent review on the analtytical techniques for the screening of reactive drug metabolites by LC-MS/MS.
    • (2009) Chem. Biol. Interact. , vol.179 , Issue.1 , pp. 25-37
    • Ma, S.1    Zhu, M.2
  • 6
    • 33749009806 scopus 로고    scopus 로고
    • Detecting and characterizing reactive metabolites by liquid chromatography/tandem mass spectrometry
    • Ma S, Subramanian R. Detecting and characterizing reactive metabolites by liquid chromatography/tandem mass spectrometry. J. Mass Spectrom. 41(9), 1121-1139 (2006
    • (2006) J. Mass Spectrom. , vol.41 , Issue.9 , pp. 1121-1139
    • Ma, S.1    Subramanian, R.2
  • 7
    • 14844316005 scopus 로고    scopus 로고
    • A high-throughput liquid chromatography/tandem mass spectrometry method for screening glutathione conjugates using exact mass neutral loss acquisition
    • Castro-Perez J, Plumb R, Liang L, Yang E. A high-throughput liquid chromatography/tandem mass spectrometry method for screening glutathione conjugates using exact mass neutral loss acquisition. Rapid Commun. Mass Spectrom. 19(6), 798-804 (2005
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , Issue.6 , pp. 798-804
    • Castro-Perez, J.1    Plumb, R.2    Liang, L.3    Yang, E.4
  • 8
    • 50049128215 scopus 로고    scopus 로고
    • Unbiased high-throughput screening of reactive metabolites on the linear ion trap mass spectrometer using polarity switch and mass tag triggered data-dependent acquisition
    • Yan Z, Caldwell GW, Maher N. Unbiased high-throughput screening of reactive metabolites on the linear ion trap mass spectrometer using polarity switch and mass tag triggered data-dependent acquisition. Anal. Chem. 80(16), 6410-6422 (2008
    • (2008) Anal. Chem. , vol.80 , Issue.16 , pp. 6410-6422
    • Yan, Z.1    Caldwell, G.W.2    Maher, N.3
  • 9
    • 10044279528 scopus 로고    scopus 로고
    • Stable-isotope trapping and high-throughput screenings of reactive metabolites using the isotope MS signature
    • Yan Z, Caldwell GW. Stable-isotope trapping and high-throughput screenings of reactive metabolites using the isotope MS signature. Anal. Chem. 76(23), 6835-6847 (2004
    • (2004) Anal. Chem. , vol.76 , Issue.23 , pp. 6835-6847
    • Yan, Z.1    Caldwell, G.W.2
  • 10
    • 77951262163 scopus 로고    scopus 로고
    • Improved detection of reactive metabolites with a bromine-containing glutathione analog using mass defect and isotope pattern matching
    • Leblanc A, Shiao TC, Roy R, Sleno L. Improved detection of reactive metabolites with a bromine-containing glutathione analog using mass defect and isotope pattern matching. Rapid Commun. Mass Spectrom. 24(9), 1241-1250 (2010
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , Issue.9 , pp. 1241-1250
    • Leblanc, A.1    Shiao, T.C.2    Roy, R.3    Sleno, L.4
  • 12
    • 83655164516 scopus 로고    scopus 로고
    • Enhanced screening of glutathione-trapped reactive metabolites by in-source collision-induced dissociation and extraction of product ion using UHPLC-high resolution mass ppectrometry
    • Zhu X, Kalyanaraman N, Subramanian R. Enhanced screening of glutathione-trapped reactive metabolites by in-source collision-induced dissociation and extraction of product ion using UHPLC-high resolution mass ppectrometry. Anal. Chem. 83(24), 9516-9523 (2011
    • (2011) Anal. Chem. , vol.83 , Issue.24 , pp. 9516-9523
    • Zhu, X.1    Kalyanaraman, N.2    Subramanian, R.3
  • 13
    • 79959958529 scopus 로고    scopus 로고
    • Performance characteristics of a new hybrid quadrupole time-of-flight tandem mass spectrometer (TripleTOF 5600
    • Andrews GL, Simons BL, Young JB, Hawkridge AM, Muddiman DC. Performance characteristics of a new hybrid quadrupole time-of-flight tandem mass spectrometer (TripleTOF 5600). Anal. Chem. 83(13), 5442-5446 (2011
    • (2011) Anal. Chem. , vol.83 , Issue.13 , pp. 5442-5446
    • Andrews, G.L.1    Simons, B.L.2    Young, J.B.3    Hawkridge, A.M.4    Muddiman, D.C.5
  • 14
    • 77955790535 scopus 로고    scopus 로고
    • Fourier transform mass spectrometry for metabolome analysis
    • Junot C, Madalinski G, Tabet JC, Ezan E. Fourier transform mass spectrometry for metabolome analysis. Analyst 135(9), 2203-2219 (2010
    • (2010) Analyst , vol.135 , Issue.9 , pp. 2203-2219
    • Junot, C.1    Madalinski, G.2    Tabet, J.C.3    Ezan, E.4
  • 15
    • 77953362009 scopus 로고    scopus 로고
    • Coupling liquid chromatography to Orbitrap mass spectrometry
    • Makarov A, Scigelova M. Coupling liquid chromatography to Orbitrap mass spectrometry. J. Chromatogr. A 1217(25), 3938-3945 (2010
    • (2010) J. Chromatogr. A , vol.1217 , Issue.25 , pp. 3938-3945
    • Makarov, A.1    Scigelova, M.2
  • 16
    • 77951741252 scopus 로고    scopus 로고
    • Advances in bioanalytical LC-MS using the Orbitrap mass analyzer
    • Scigelova M, Makarov A. Advances in bioanalytical LC-MS using the Orbitrap mass analyzer. Bioanalysis 1(4), 741-754 (2009
    • (2009) Bioanalysis , vol.1 , Issue.4 , pp. 741-754
    • Scigelova, M.1    Makarov, A.2
  • 17
    • 67650494794 scopus 로고    scopus 로고
    • Mass defect filter technique and its applications to drug metabolite identification by high-resolution mass spectrometry
    • nComprehensive review on mass defect filter and its application to metabolite identification.
    • Zhang H, Zhang D, Ray K, Zhu M. Mass defect filter technique and its applications to drug metabolite identification by high-resolution mass spectrometry. J. Mass Spectrom. 44(7), 999-1016 (2009). nComprehensive review on mass defect filter and its application to metabolite identification.
    • (2009) J. Mass Spectrom. , vol.44 , Issue.7 , pp. 999-1016
    • Zhang, H.1    Zhang, D.2    Ray, K.3    Zhu, M.4
  • 18
    • 0242521617 scopus 로고    scopus 로고
    • A software filter to remove interference ions from drug metabolites in accurate mass liquid chromatography/mass spectrometric analyses
    • Zhang H, Zhang D, Ray K. A software filter to remove interference ions from drug metabolites in accurate mass liquid chromatography/mass spectrometric analyses. J. Mass Spectrom. 38(10), 1110-1112 (2003
    • (2003) J. Mass Spectrom. , vol.38 , Issue.10 , pp. 1110-1112
    • Zhang, H.1    Zhang, D.2    Ray, K.3
  • 19
    • 52649157604 scopus 로고    scopus 로고
    • An algorithm for thorough background subtraction from high-resolution LC-MS data: Application for detection of glutathione-trapped reactive metabolites
    • Zhang H, Yang Y. An algorithm for thorough background subtraction from high-resolution LC-MS data: Application for detection of glutathione-trapped reactive metabolites. J. Mass Spectrom. 43(9), 1181-1190 (2008
    • (2008) J. Mass Spectrom. , vol.43 , Issue.9 , pp. 1181-1190
    • Zhang, H.1    Yang, Y.2
  • 20
    • 66149168573 scopus 로고    scopus 로고
    • A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices
    • nDetailed description of the background subtraction and noise reduction algorithm.
    • Zhu P, Ding W, Tong W, Ghosal A, Alton K, Chowdhury S. A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices. Rapid Commun. Mass Spectrom. 23(11), 1563-1572 (2009). nDetailed description of the background subtraction and noise reduction algorithm.
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , Issue.11 , pp. 1563-1572
    • Zhu, P.1    Ding, W.2    Tong, W.3    Ghosal, A.4    Alton, K.5    Chowdhury, S.6
  • 21
    • 67650757742 scopus 로고    scopus 로고
    • An accurate-mass-based spectral-averaging isotope-pattern-filtering algorithm for extraction of drug metabolites possessing a distinct isotope pattern from LC-MS data
    • nDetailed description of the isotope pattern-filtering algorithm.
    • Zhu P, Tong W, Alton K, Chowdhury S. An accurate-mass-based spectral-averaging isotope-pattern-filtering algorithm for extraction of drug metabolites possessing a distinct isotope pattern from LC-MS data. Anal. Chem. 81(14), 5910-5917 (2009). nDetailed description of the isotope pattern-filtering algorithm.
    • (2009) Anal. Chem. , vol.81 , Issue.14 , pp. 5910-5917
    • Zhu, P.1    Tong, W.2    Alton, K.3    Chowdhury, S.4
  • 22
    • 35848937158 scopus 로고    scopus 로고
    • Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass spectrometry and mass defect filtering
    • Zhu M, Ma L, Zhang H, Humphreys WG. Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass spectrometry and mass defect filtering. Anal. Chem. 79(21), 8333-8341 (2007
    • (2007) Anal. Chem. , vol.79 , Issue.21 , pp. 8333-8341
    • Zhu, M.1    Ma, L.2    Zhang, H.3    Humphreys, W.G.4
  • 23
    • 77952400154 scopus 로고    scopus 로고
    • Investigation of bioactivation of ticlopidine using linear ion trap/Orbitrap mass spectrometry and an improved mass defect filtering technique
    • Ruan Q, Zhu M. Investigation of bioactivation of ticlopidine using linear ion trap/Orbitrap mass spectrometry and an improved mass defect filtering technique. Chem. Res. Toxicol. 23(5), 909-917 (2010
    • (2010) Chem. Res. Toxicol. , vol.23 , Issue.5 , pp. 909-917
    • Ruan, Q.1    Zhu, M.2
  • 24
    • 80053232023 scopus 로고    scopus 로고
    • High-resolution chromatography/time-of-flight MSE with in silico data mining is an information-rich approach to reactive metabolite screening
    • Barbara JE, Castro-Perez JM. High-resolution chromatography/time-of- flight MSE with in silico data mining is an information-rich approach to reactive metabolite screening. Rapid Commun. Mass Spectrom. 25(20), 3029-3040 (2011
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , Issue.20 , pp. 3029-3040
    • Barbara, J.E.1    Castro-Perez, J.M.2
  • 25
    • 84858395589 scopus 로고    scopus 로고
    • High-throughput screening of drug reactive metabolites using accurate-mass-based background subtraction and noise reduction algorithm
    • Salt Lake City, UT, USA, 23-27 May
    • Ma S, Yuan Y, Lu X et al. High-throughput screening of drug reactive metabolites using accurate-mass-based background subtraction and noise reduction algorithm. Presented at: 58th ASMS Conference on Mass Spectrometry and Allied Topics. Salt Lake City, UT, USA, 23-27 May 2010.
    • (2010) 58th ASMS Conference on Mass Spectrometry and Allied Topics
    • Ma, S.1    Yuan, Y.2    Lu, X.3
  • 26
    • 49049114287 scopus 로고    scopus 로고
    • Rapid screening of glutathione-trapped reactive metabolites by linear ion trap mass spectrometry with isotope pattern-dependent scanning and postacquisition data mining
    • Ma L, Wen B, Ruan Q, Zhu M. Rapid screening of glutathione-trapped reactive metabolites by linear ion trap mass spectrometry with isotope pattern-dependent scanning and postacquisition data mining. Chem. Res. Toxicol. 21(7), 1477-1483 (2008
    • (2008) Chem. Res. Toxicol. , vol.21 , Issue.7 , pp. 1477-1483
    • Ma, L.1    Wen, B.2    Ruan, Q.3    Zhu, M.4
  • 27
    • 64149085994 scopus 로고    scopus 로고
    • Rapid detection and characterization of reactive drug metabolites in vitro using several isotope-labeled trapping agents and ultra-performance liquid chromatography/time-of-flight mass spectrometry
    • Rousu T, Pelkonen O, Tolonen A. Rapid detection and characterization of reactive drug metabolites in vitro using several isotope-labeled trapping agents and ultra-performance liquid chromatography/time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 23(6), 843-855 (2009
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , Issue.6 , pp. 843-855
    • Rousu, T.1    Pelkonen, O.2    Tolonen, A.3
  • 28
    • 42649118458 scopus 로고    scopus 로고
    • A generic method to detect electrophilic intermediates using isotopic pattern triggered data-dependent high-resolution accurate mass spectrometry
    • Lim HK, Chen J, Cook K, Sensenhauser C, Silva J, Evans DC. A generic method to detect electrophilic intermediates using isotopic pattern triggered data-dependent high-resolution accurate mass spectrometry. Rapid Commun. Mass Spectrom. 22(8), 1295-1311 (2008
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , Issue.8 , pp. 1295-1311
    • Lim, H.K.1    Chen, J.2    Cook, K.3    Sensenhauser, C.4    Silva, J.5    Evans, D.C.6
  • 29
    • 84858400637 scopus 로고    scopus 로고
    • A software platform for reactive metabolite detection using low and high resolution mass spectrometry data
    • Salt Lake City, UT, USA, 23-27 May
    • Ruijken MMA. MsXelerator RM: A software platform for reactive metabolite detection using low and high resolution mass spectrometry data. Presented at: 58th ASMS Conference on Mass Spectrometry and Allied Topics. Salt Lake City, UT, USA, 23-27 May 2010.
    • (2010) 58th ASMS Conference on Mass Spectrometry and Allied Topics
    • Ruijken, M.M.A.1    MsXelerator, R.M.2
  • 30
    • 18944396519 scopus 로고    scopus 로고
    • Dansyl glutathione as a trapping agent for the quantitative estimation and identification of reactive metabolites
    • Gan J, Harper TW, Hsueh MM, Qu Q, Humphreys WG. Dansyl glutathione as a trapping agent for the quantitative estimation and identification of reactive metabolites. Chem. Res. Toxicol. 18(5), 896-903 (2005
    • (2005) Chem. Res. Toxicol. , vol.18 , Issue.5 , pp. 896-903
    • Gan, J.1    Harper, T.W.2    Hsueh, M.M.3    Qu, Q.4    Humphreys, W.G.5
  • 31
    • 66149104042 scopus 로고    scopus 로고
    • In vitro screening of 50 highly prescribed drugs for thiol adduct formation-comparison of potential for drug-induced toxicity and extent of adduct formation
    • Gan J, Ruan Q, He B, Zhu M, Shyu WC, Humphreys WG. In vitro screening of 50 highly prescribed drugs for thiol adduct formation-comparison of potential for drug-induced toxicity and extent of adduct formation. Chem. Res. Toxicol. 22(4), 690-698 (2009
    • (2009) Chem. Res. Toxicol. , vol.22 , Issue.4 , pp. 690-698
    • Gan, J.1    Ruan, Q.2    He, B.3    Zhu, M.4    Shyu, W.C.5    Humphreys, W.G.6
  • 32
    • 33645469797 scopus 로고    scopus 로고
    • A semiquantitative method for the determination of reactive metabolite conjugate levels in vitro utilizing liquid chromatography-tandem mass spectrometry and novel quaternary ammonium glutathione analogues
    • Soglia JR, Contillo LG, Kalgutkar AS et al. A semiquantitative method for the determination of reactive metabolite conjugate levels in vitro utilizing liquid chromatography-tandem mass spectrometry and novel quaternary ammonium glutathione analogues. Chem. Res. Toxicol. 19(3), 480-490 (2006
    • (2006) Chem. Res. Toxicol. , vol.19 , Issue.3 , pp. 480-490
    • Soglia, J.R.1    Contillo, L.G.2    Kalgutkar, A.S.3
  • 33
    • 38949099990 scopus 로고    scopus 로고
    • Mechanism-based inactivation of human cytochromes P450s: Experimental characterization, reactive intermediates, and clinical implications
    • Hollenberg PF, Kent UM, Bumpus NN. Mechanism-based inactivation of human cytochromes P450s: Experimental characterization, reactive intermediates, and clinical implications. Chem. Res. Toxicol. 21(1), 189-205 (2008
    • (2008) Chem. Res. Toxicol. , vol.21 , Issue.1 , pp. 189-205
    • Hollenberg, P.F.1    Kent, U.M.2    Bumpus, N.N.3
  • 34
    • 79958072363 scopus 로고    scopus 로고
    • Overview of strategies for addressing BRIs in drug discovery: Impact on optimization and design
    • Humphreys WG. Overview of strategies for addressing BRIs in drug discovery: Impact on optimization and design. Chem. Biol. Interact. 192(1-2), 56-59 (2011
    • (2011) Chem. Biol. Interact. , vol.192 , Issue.1-2 , pp. 56-59
    • Humphreys, W.G.1
  • 35
    • 71049174955 scopus 로고    scopus 로고
    • Evaluation of the potential for drug-induced liver injury based on in vitro covalent binding to human liver proteins
    • Usui T, Mise M, Hashizume T, Yabuki M, Komuro S. Evaluation of the potential for drug-induced liver injury based on in vitro covalent binding to human liver proteins. Drug Metab. Dispos. 37(12), 2383-2392 (2009).
    • (2009) Drug Metab. Dispos. , vol.37 , Issue.12 , pp. 2383-2392
    • Usui, T.1    Mise, M.2    Hashizume, T.3    Yabuki, M.4    Komuro, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.