-
1
-
-
60449094498
-
Heart disease and stroke statistics-2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee
-
Lloyd-Jones D, Adams R, Carnethon M, De Simone G, Ferguson TB, et al. (2009) Heart disease and stroke statistics-2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation 119: e21-181.
-
(2009)
Circulation
, vol.119
-
-
Lloyd-Jones, D.1
Adams, R.2
Carnethon, M.3
de Simone, G.4
Ferguson, T.B.5
-
2
-
-
0038247924
-
Total artificial hearts: bridge to transplantation
-
Copeland JG, Arabia FA, Tsau PH, Nolan PE, McClellan D, et al. (2003) Total artificial hearts: bridge to transplantation. Cardiol Clin 21: 101-113.
-
(2003)
Cardiol Clin
, vol.21
, pp. 101-113
-
-
Copeland, J.G.1
Arabia, F.A.2
Tsau, P.H.3
Nolan, P.E.4
McClellan, D.5
-
3
-
-
34548183335
-
Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies
-
Alemu Y, Bluestein D, (2007) Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. Artif Organs 31: 677-688.
-
(2007)
Artif Organs
, vol.31
, pp. 677-688
-
-
Alemu, Y.1
Bluestein, D.2
-
4
-
-
0001960147
-
-
New York, Springer and Verlag
-
Hellums JD, Peterson DM, Stathopoulos NA, Moake JL, Giorgio TD, (1987) Studies on the mechanisms of shear-induced platelet activation New York Springer and Verlag.
-
(1987)
Studies on the Mechanisms of Shear-Induced Platelet Activation
-
-
Hellums, J.D.1
Peterson, D.M.2
Stathopoulos, N.A.3
Moake, J.L.4
Giorgio, T.D.5
-
5
-
-
0028500967
-
1993 Whitaker Lecture: biorheology in thrombosis research
-
Hellums JD, (1994) 1993 Whitaker Lecture: biorheology in thrombosis research. Ann Biomed Eng 22: 445-455.
-
(1994)
Ann Biomed Eng
, vol.22
, pp. 445-455
-
-
Hellums, J.D.1
-
6
-
-
4544287269
-
Flow-induced platelet activation in a Mechanical Heart Valve
-
Bluestein D, Yin W, Affeld K, Jesty J, (2004) Flow-induced platelet activation in a Mechanical Heart Valve. J Heart Valve Dis 13: 501-508.
-
(2004)
J Heart Valve Dis
, vol.13
, pp. 501-508
-
-
Bluestein, D.1
Yin, W.2
Affeld, K.3
Jesty, J.4
-
7
-
-
9044221761
-
Ex vivo phase 1 evaluation of the DeBakey/NASA axial flow ventricular assist device
-
Kawahito K, Damm G, Benkowski R, Aber G, Bacak J, et al. (1996) Ex vivo phase 1 evaluation of the DeBakey/NASA axial flow ventricular assist device. Artif Organs 20: 47-52.
-
(1996)
Artif Organs
, vol.20
, pp. 47-52
-
-
Kawahito, K.1
Damm, G.2
Benkowski, R.3
Aber, G.4
Bacak, J.5
-
8
-
-
0042917714
-
Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation
-
Goldstein DJ, (2003) Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation. Circulation 108 (Suppl 1): II 272-277.
-
(2003)
Circulation
, vol.108
, Issue.SUPPL. 1
, pp. 272-277
-
-
Goldstein, D.J.1
-
9
-
-
38349187878
-
Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements
-
Nobili M, Sheriff J, Morbiducci U, Redaelli A, Bluestein D, (2008) Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements. ASAIO J 54: 64-72.
-
(2008)
ASAIO J
, vol.54
, pp. 64-72
-
-
Nobili, M.1
Sheriff, J.2
Morbiducci, U.3
Redaelli, A.4
Bluestein, D.5
-
10
-
-
0033566160
-
Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin
-
Jesty J, Bluestein D, (1999) Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin. Anal Biochem 272: 64-70.
-
(1999)
Anal Biochem
, vol.272
, pp. 64-70
-
-
Jesty, J.1
Bluestein, D.2
-
11
-
-
0034837086
-
Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
-
Apel J, Paul R, Klaus S, Siess T, Reul H, (2001) Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. Artif Organs 25: 341-347.
-
(2001)
Artif Organs
, vol.25
, pp. 341-347
-
-
Apel, J.1
Paul, R.2
Klaus, S.3
Siess, T.4
Reul, H.5
-
12
-
-
77956393128
-
Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve
-
Alemu Y, Girdhar G, Xenos M, Sheriff J, Jesty J, et al. (2010) Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve. ASAIO J 56: 389-396.
-
(2010)
ASAIO J
, vol.56
, pp. 389-396
-
-
Alemu, Y.1
Girdhar, G.2
Xenos, M.3
Sheriff, J.4
Jesty, J.5
-
13
-
-
77955560669
-
Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs
-
Xenos M, Girdhar G, Alemu Y, Jesty J, Slepian M, et al. (2010) Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. J Biomech 43: 2400-2409.
-
(2010)
J Biomech
, vol.43
, pp. 2400-2409
-
-
Xenos, M.1
Girdhar, G.2
Alemu, Y.3
Jesty, J.4
Slepian, M.5
-
14
-
-
0034074215
-
Development and clinical application of the MicroMed DeBakey VAD
-
Noon GP, Morley D, Irwin S, Benkowski R, (2000) Development and clinical application of the MicroMed DeBakey VAD. Curr Opin Cardiol 15: 166-171.
-
(2000)
Curr Opin Cardiol
, vol.15
, pp. 166-171
-
-
Noon, G.P.1
Morley, D.2
Irwin, S.3
Benkowski, R.4
-
15
-
-
0020847040
-
Aspects of computer simulation of liquid-fuelled combustors
-
Gosman AD, Ioannides E, (1983) Aspects of computer simulation of liquid-fuelled combustors. AIAA J Energy 7: 482-490.
-
(1983)
AIAA J Energy
, vol.7
, pp. 482-490
-
-
Gosman, A.D.1
Ioannides, E.2
-
16
-
-
0028372478
-
Simulation of transition with a two-equation turbulence model
-
Wilcox DC, (1994) Simulation of transition with a two-equation turbulence model. AIAA J 32: 247-255.
-
(1994)
AIAA J
, vol.32
, pp. 247-255
-
-
Wilcox, D.C.1
-
17
-
-
79951553780
-
Numerical investigation of the effects of channel geometry on platelet activation and blood damage
-
Wu J, Yun BM, Fallon AM, Hanson SR, Aidun CK, et al. (2011) Numerical investigation of the effects of channel geometry on platelet activation and blood damage. Ann Biomed Eng 39: 897-910.
-
(2011)
Ann Biomed Eng
, vol.39
, pp. 897-910
-
-
Wu, J.1
Yun, B.M.2
Fallon, A.M.3
Hanson, S.R.4
Aidun, C.K.5
-
19
-
-
36549028303
-
Small pumps for ventricular assistance: progress in mechanical circulatory support
-
Frazier OH, Jacob LP, (2007) Small pumps for ventricular assistance: progress in mechanical circulatory support. Cardiol Clin 25: 553-564;
-
(2007)
Cardiol Clin
, vol.25
, pp. 553-564
-
-
Frazier, O.H.1
Jacob, L.P.2
-
20
-
-
48449103802
-
Microhaemodynamics within the blade tip clearance of a centrifugal turbodynamic blood pump
-
Antaki JF, Diao CG, Shu FJ, Wu JC, Zhao R, et al. (2008) Microhaemodynamics within the blade tip clearance of a centrifugal turbodynamic blood pump. Proc Inst Mech Eng H 222: 573-581.
-
(2008)
Proc Inst Mech Eng H
, vol.222
, pp. 573-581
-
-
Antaki, J.F.1
Diao, C.G.2
Shu, F.J.3
Wu, J.C.4
Zhao, R.5
-
21
-
-
66449137870
-
Parametric study of blade tip clearance, flow rate, and impeller speed on blood damage in rotary blood pump
-
Kim NJ, Diao C, Ahn KH, Lee SJ, Kameneva MV, et al. (2009) Parametric study of blade tip clearance, flow rate, and impeller speed on blood damage in rotary blood pump. Artif Organs 33: 468-474.
-
(2009)
Artif Organs
, vol.33
, pp. 468-474
-
-
Kim, N.J.1
Diao, C.2
Ahn, K.H.3
Lee, S.J.4
Kameneva, M.V.5
-
22
-
-
77949675918
-
Shape optimization of the diffuser blade of an axial blood pump by computational fluid dynamics
-
Zhu L, Zhang X, Yao Z, (2010) Shape optimization of the diffuser blade of an axial blood pump by computational fluid dynamics. Artif Organs 34: 185-192.
-
(2010)
Artif Organs
, vol.34
, pp. 185-192
-
-
Zhu, L.1
Zhang, X.2
Yao, Z.3
-
23
-
-
76849112530
-
Numerical study of a centrifugal blood pump with different impeller profiles
-
Song G, Chua LP, Lim TM, (2010) Numerical study of a centrifugal blood pump with different impeller profiles. ASAIO J 56: 24-29.
-
(2010)
ASAIO J
, vol.56
, pp. 24-29
-
-
Song, G.1
Chua, L.P.2
Lim, T.M.3
-
24
-
-
0030892898
-
Improved flow straighteners reduce thrombus in the NASA/DeBakey axial flow ventricular assist device
-
Kawahito K, Benkowski R, Ohtsubo S, Noon GP, Nose Y, et al. (1997) Improved flow straighteners reduce thrombus in the NASA/DeBakey axial flow ventricular assist device. Artif Organs 21: 339-343.
-
(1997)
Artif Organs
, vol.21
, pp. 339-343
-
-
Kawahito, K.1
Benkowski, R.2
Ohtsubo, S.3
Noon, G.P.4
Nose, Y.5
-
25
-
-
20644438647
-
Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump
-
Chan WK, Wong YW, Ong W, Koh SY, Chong V, (2005) Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump. Artif Organs 29: 250-258.
-
(2005)
Artif Organs
, vol.29
, pp. 250-258
-
-
Chan, W.K.1
Wong, Y.W.2
Ong, W.3
Koh, S.Y.4
Chong, V.5
-
27
-
-
0036266486
-
Platelet activation, aggregation, and life span in calves implanted with axial flow ventricular assist devices
-
Snyder TA, Watach MJ, Litwak KN, Wagner WR, (2002) Platelet activation, aggregation, and life span in calves implanted with axial flow ventricular assist devices. Ann Thorac Surg 73: 1933-1938.
-
(2002)
Ann Thorac Surg
, vol.73
, pp. 1933-1938
-
-
Snyder, T.A.1
Watach, M.J.2
Litwak, K.N.3
Wagner, W.R.4
-
28
-
-
0035100167
-
Clinical experience with the MicroMed DeBakey ventricular assist device
-
discussion S144-136
-
Noon GP, Morley DL, Irwin S, Abdelsayed SV, Benkowski RJ, et al. (2001) Clinical experience with the MicroMed DeBakey ventricular assist device. Ann Thorac Surg 71: S133-138; discussion S144-136.
-
(2001)
Ann Thorac Surg
, vol.71
, pp. 133-138
-
-
Noon, G.P.1
Morley, D.L.2
Irwin, S.3
Abdelsayed, S.V.4
Benkowski, R.J.5
-
29
-
-
0035023421
-
Complications common to ventricular assist device support are rare with 90 days of DeBakey VAD support in calves
-
Fossum TW, Morley D, Olsen DB, Edwards J, Burns G, et al. (2001) Complications common to ventricular assist device support are rare with 90 days of DeBakey VAD support in calves. ASAIO J 47: 288-292.
-
(2001)
ASAIO J
, vol.47
, pp. 288-292
-
-
Fossum, T.W.1
Morley, D.2
Olsen, D.B.3
Edwards, J.4
Burns, G.5
-
30
-
-
0034141909
-
First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation
-
Wieselthaler GM, Schima H, Hiesmayr M, Pacher R, Laufer G, et al. (2000) First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation. Circulation 101: 356-359.
-
(2000)
Circulation
, vol.101
, pp. 356-359
-
-
Wieselthaler, G.M.1
Schima, H.2
Hiesmayr, M.3
Pacher, R.4
Laufer, G.5
-
31
-
-
78751566512
-
Thrombogenic potential of Innovia polymer valves versus Carpentier-Edwards Perimount Magna aortic bioprosthetic valves
-
Claiborne TE, Girdhar G, Gallocher-Lowe S, Sheriff J, Kato YP, et al. (2011) Thrombogenic potential of Innovia polymer valves versus Carpentier-Edwards Perimount Magna aortic bioprosthetic valves. ASAIO J 57: 26-31.
-
(2011)
ASAIO J
, vol.57
, pp. 26-31
-
-
Claiborne, T.E.1
Girdhar, G.2
Gallocher-Lowe, S.3
Sheriff, J.4
Kato, Y.P.5
|