-
1
-
-
0029086396
-
Computational flow optimization of rotary blood pump components
-
Antaki JF, Ghattas O, Burgreen GW, He B: Computational flow optimization of rotary blood pump components. Artif Organs 19: 608-615, 1995.
-
(1995)
Artif Organs
, vol.19
, pp. 608-615
-
-
Antaki, J.F.1
Ghattas, O.2
Burgreen, G.W.3
He, B.4
-
2
-
-
0242301758
-
An estimated method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis
-
Yano T, Sekine K, Mitoh A, et al: An estimated method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis. Artif Organs 27: 920-925, 2003.
-
(2003)
Artif Organs
, vol.27
, pp. 920-925
-
-
Yano, T.1
Sekine, K.2
Mitoh, A.3
-
3
-
-
20144363067
-
Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device
-
Burgreen GW, Loree HM II, Bourque K, et al: Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device. Artif Organs 28: 874-880, 2003.
-
(2003)
Artif Organs
, vol.28
, pp. 874-880
-
-
Burgreen, G.W.1
Loree II, H.M.2
Bourque, K.3
-
4
-
-
11144347532
-
Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics
-
Song X, Throckmorton AL, Wood HG, et al: Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics. ASME J Fluids Eng 126: 410-418, 2004.
-
(2004)
ASME J Fluids Eng
, vol.126
, pp. 410-418
-
-
Song, X.1
Throckmorton, A.L.2
Wood, H.G.3
-
5
-
-
0010284955
-
The 'Teaspoon pump', a new centrifugal pump
-
Bauermeister U, Affeld K, Berger E: The 'Teaspoon pump', a new centrifugal pump. ASAIO Abstracts 28: 11-12, 1982.
-
(1982)
ASAIO Abstracts
, vol.28
, pp. 11-12
-
-
Bauermeister, U.1
Affeld, K.2
Berger, E.3
-
6
-
-
0001865519
-
-
Tokyo, Japan Springer Verlag
-
Takeuchi T, Minotopya K, Nishimura K, et al: Experimental Study of Nutating Centrifugal Blood Pump In Vivo. Artificial Heart: 3 Proceedings of Heart and Assist Devices. Tokyo, Japan Springer Verlag, 1990, pp. 93-101.
-
(1990)
Experimental Study of Nutating Centrifugal Blood Pump in Vivo. Artificial Heart: 3 Proceedings of Heart and Assist Devices
, pp. 93-101
-
-
Takeuchi, T.1
Minotopya, K.2
Nishimura, K.3
-
7
-
-
0008582135
-
Recent development of a centrifugal blood pump with a magnetically suspended impeller
-
Presented at the Sendai, Japan, the Japan Society Mechanical Engineers (JSME)
-
Akamatsu T, Nakazeki T: Recent development of a centrifugal blood pump with a magnetically suspended impeller. Presented at the Proceedings of the third JSME-KSME Fluids Engineering Conference, Sendai, Japan, the Japan Society Mechanical Engineers (JSME) 1994, pp. 305-308.
-
(1994)
Proceedings of the Third JSME-KSME Fluids Engineering Conference
, pp. 305-308
-
-
Akamatsu, T.1
Nakazeki, T.2
-
8
-
-
33744695972
-
Fluid dynamics design of Kyoto-NTN magnetically suspended centrifugal blood pump
-
Tsukiya T, Akamatsu T, Ozaki T: Fluid dynamics design of Kyoto- NTN magnetically suspended centrifugal blood pump. ASME FEDSM 97: 3425, 1997.
-
(1997)
ASME FEDSM
, vol.97
, pp. 3425
-
-
Tsukiya, T.1
Akamatsu, T.2
Ozaki, T.3
-
9
-
-
0035013289
-
The angle resolved velocity measurement in the impeller passages of the model biocentrifugal pump
-
Yu SCM, Chua LP, Leo HL: The angle resolved velocity measurement in the impeller passages of the model biocentrifugal pump. Proc Instn Mech Engrs Part C 215: 547-568, 2001.
-
(2001)
Proc Instn Mech Engrs Part C
, vol.215
, pp. 547-568
-
-
Yu, S.C.M.1
Chua, L.P.2
Leo, H.L.3
-
10
-
-
0034173954
-
Measurement of gap pressure and wall shear stress of a blood pump model
-
Chua LP, Akamatsu T: Measurement of gap pressure and wall shear stress of a blood pump model. Med Eng Phys 22: 175-188, 2000.
-
(2000)
Med Eng Phys
, vol.22
, pp. 175-188
-
-
Chua, L.P.1
Akamatsu, T.2
-
11
-
-
0242301754
-
Leakage flow measurements in a bio-centrifugal ventricular assist device model
-
Chua LP, Ong KS, Yu SCM, Zhou TM: Leakage flow measurements in a bio-centrifugal ventricular assist device model. Artif Organs 27: 942-959, 2003.
-
(2003)
Artif Organs
, vol.27
, pp. 942-959
-
-
Chua, L.P.1
Ong, K.S.2
Yu, S.C.M.3
Zhou, T.M.4
-
12
-
-
10044288363
-
Leakage flow rate and wall shear stress distributions in a bio-centrifugal ventricular assist device
-
Chua LP, Ong KS, Yu SCM, Zhou TM: Leakage flow rate and wall shear stress distributions in a bio-centrifugal ventricular assist device. ASAIO J 50: 530-536, 2004.
-
(2004)
ASAIO J
, vol.50
, pp. 530-536
-
-
Chua, L.P.1
Ong, K.S.2
Yu, S.C.M.3
Zhou, T.M.4
-
13
-
-
0347658786
-
The issue of numerical uncertainty
-
Presented at CSIRO, Melbourne, Australia, Elsevier BV
-
Freitas CJ: The issue of numerical uncertainty. Presented at the Second International Conference on CFD in the Minerals and Process Industries, CSIRO, Melbourne, Australia, Elsevier BV, 1999, pp. 29-34.
-
(1999)
The Second International Conference on CFD in the Minerals and Process Industries
, pp. 29-34
-
-
Freitas, C.J.1
-
14
-
-
0033918274
-
Numerical analysis of blood flow in the clearance region of a continuous flow artificial heart pump
-
Andrews J, Wood HG, Allaire PE, Olsen DB: Numerical analysis of blood flow in the clearance region of a continuous flow artificial heart pump. Artif Organs 24: 492-500, 2000.
-
(2000)
Artif Organs
, vol.24
, pp. 492-500
-
-
Andrews, J.1
Wood, H.G.2
Allaire, P.E.3
Olsen, D.B.4
-
15
-
-
15444362825
-
Computational analysis of an axial flow pediatric ventricular assist device
-
Throckmorton AL, Untaroiu A, Allaire PE, et al: Computational analysis of an axial flow pediatric ventricular assist device. Artif Organs 28: 881-891, 2004.
-
(2004)
Artif Organs
, vol.28
, pp. 881-891
-
-
Throckmorton, A.L.1
Untaroiu, A.2
Allaire, P.E.3
-
16
-
-
27744605262
-
Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance
-
Untaroiu A, Throckmorton AL, Patel SM, et al: Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance. Artif Organs 29: 581-581, 2005.
-
(2005)
Artif Organs
, vol.29
, pp. 581-581
-
-
Untaroiu, A.1
Throckmorton, A.L.2
Patel, S.M.3
-
18
-
-
0029090222
-
Model for general mechanical blood damage prediction
-
Bludszuweit C: Model for general mechanical blood damage prediction. Artif Organs 19: 583-589, 1995.
-
(1995)
Artif Organs
, vol.19
, pp. 583-589
-
-
Bludszuweit, C.1
-
19
-
-
0025082325
-
Estimation of shear stress-related blood damage in heart valve prostheses-In vitro comparison of 25 aortix valves
-
Giersiepen M, Wurzinger LJ, Opitz R, Reul H: Estimation of shear stress-related blood damage in heart valve prostheses-In vitro comparison of 25 aortix valves. Int J Artif Organs 13: 300-306, 1990.
-
(1990)
Int J Artif Organs
, vol.13
, pp. 300-306
-
-
Giersiepen, M.1
Wurzinger, L.J.2
Opitz, R.3
Reul, H.4
-
20
-
-
60349124009
-
Laser Doppler anemometer measurements of the flow in the impeller blade channels of a centrifugal blood pump
-
Song GL, Chua LP: Laser Doppler anemometer measurements of the flow in the impeller blade channels of a centrifugal blood pump. HKIE Trans 15: 11-16, 2009.
-
(2009)
HKIE Trans
, vol.15
, pp. 11-16
-
-
Song, G.L.1
Chua, L.P.2
-
21
-
-
33744751460
-
Numerical analysis of the inner flow field of a bio-centrifugal blood pump
-
Chua LP, Song GL, Lim TM, Zhou TM: Numerical analysis of the inner flow field of a bio-centrifugal blood pump. Artif Organs 30: 467-477, 2006.
-
(2006)
Artif Organs
, vol.30
, pp. 467-477
-
-
Chua, L.P.1
Song, G.L.2
Lim, T.M.3
Zhou, T.M.4
|