메뉴 건너뛰기




Volumn 13, Issue 3, 2004, Pages 501-508

Flow-induced platelet activation in mechanical heart valves

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; HEART ASSIST DEVICE; HEART VALVE PROSTHESIS; HUMAN; MATERIALS TESTING; MECHANICAL STRESS; PULSATILE FLOW; THROMBOCYTE ACTIVATION;

EID: 4544287269     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (87)

References (22)
  • 1
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure, the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group
    • Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end- stage heart failure, the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. N Engl J Med 2001;345:1435-1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 2
    • 0003797436 scopus 로고
    • National Heart, Lung and Blood Institute Working Group on Blood Material Interactions. Bethesda, MD, NIH Publication No. 85-2185
    • Guidelines for Blood-material Interactions. National Heart, Lung and Blood Institute Working Group on Blood Material Interactions. Bethesda, MD, NIH Publication No. 85-2185,1985
    • (1985) Guidelines for Blood-material Interactions
  • 3
    • 0023226236 scopus 로고
    • Thrombotic and bleeding complications of prosthetic heart valves
    • Edmunds LH, Jr. Thrombotic and bleeding complications of prosthetic heart valves. Ann Thorac Surg 1987;44:430-445
    • (1987) Ann Thorac Surg , vol.44 , pp. 430-445
    • Edmunds Jr., L.H.1
  • 4
    • 0342326101 scopus 로고    scopus 로고
    • Directions for improvement of substitute heart valves: National Heart, Lung, and Blood Institute's Working Group Report on Heart Valves
    • Edmunds LH, Jr., Mckinlay S, Anderson JM, et al. Directions for improvement of substitute heart valves: National Heart, Lung, and Blood Institute's Working Group Report on Heart Valves. J Biomed Materials Res 1997;38:263-266
    • (1997) J Biomed Materials Res , vol.38 , pp. 263-266
    • Edmunds Jr., L.H.1    Mckinlay, S.2    Anderson, J.M.3
  • 5
    • 0002762220 scopus 로고
    • Fluid dynamic and hemorhe-ologic considerations
    • Slack SM, Turitto VT. Fluid dynamic and hemorhe-ologic considerations. Cardiovasc Pathol 1993;2(3 suppl.):11S-21S
    • (1993) Cardiovasc Pathol , vol.2 , Issue.3 SUPPL.
    • Slack, S.M.1    Turitto, V.T.2
  • 6
    • 0020587057 scopus 로고
    • Platelet alpha granule depletion: Findings in patients with prosthetic heart valves and following cardiopulmonary bypass surgery
    • Pumphrey CW, Dawes J. Platelet alpha granule depletion: Findings in patients with prosthetic heart valves and following cardiopulmonary bypass surgery. Thromb Res 1983;30:257-264
    • (1983) Thromb Res , vol.30 , pp. 257-264
    • Pumphrey, C.W.1    Dawes, J.2
  • 7
    • 0027162867 scopus 로고
    • In vitro hematological testing of rotary blood pumps: Remarks on standardization and data interpretation
    • Müller MR, Schima H, Engelhardt H, et al. In vitro hematological testing of rotary blood pumps: Remarks on standardization and data interpretation. Artif Org 1993;17:103-110
    • (1993) Artif Org , vol.17 , pp. 103-110
    • Müller, M.R.1    Schima, H.2    Engelhardt, H.3
  • 8
    • 0035085186 scopus 로고    scopus 로고
    • The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus
    • Travis BR, Marzec UM, Ellis JT, et al. The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus. J Heart Valve Dis 2001;10:228-238
    • (2001) J Heart Valve Dis , vol.10 , pp. 228-238
    • Travis, B.R.1    Marzec, U.M.2    Ellis, J.T.3
  • 9
    • 0024852292 scopus 로고
    • Mathematical analysis of mural thrombogenesis: Concentration profiles of platelet-activating agents and effects of viscous shear flow
    • Folie BJ, Mclntire LV. Mathematical analysis of mural thrombogenesis: Concentration profiles of platelet-activating agents and effects of viscous shear flow. Biophys J 1989;56:1121-1141
    • (1989) Biophys J , vol.56 , pp. 1121-1141
    • Folie, B.J.1    Mclntire, L.V.2
  • 12
    • 0031105449 scopus 로고    scopus 로고
    • Fluid mechanics of flow through a stenosis: Relationship to the development of mural thrombus
    • Bluestein D, Niu L, Schoephoerster RT, Dewanjee MK. Fluid mechanics of flow through a stenosis: Relationship to the development of mural thrombus. Ann Biomed Eng 1997;25:344-356
    • (1997) Ann Biomed Eng , vol.25 , pp. 344-356
    • Bluestein, D.1    Niu, L.2    Schoephoerster, R.T.3    Dewanjee, M.K.4
  • 13
    • 0034177656 scopus 로고    scopus 로고
    • Vortex shedding as a mechanism for free emboli formation in mechanical heart valves
    • Bluestein D, Rambod E, Gharib M. Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. J Biomech Eng 2000;122:125-134
    • (2000) J Biomech Eng , vol.122 , pp. 125-134
    • Bluestein, D.1    Rambod, E.2    Gharib, M.3
  • 14
    • 0036889713 scopus 로고    scopus 로고
    • The role of wake dynamics in enhancing the risk of cardioembolism in mechanical heart valves - A transient and turbulent analysis
    • Bluestein D, Li Y, Krukenkamp IB. The role of wake dynamics in enhancing the risk of cardioembolism in mechanical heart valves - a transient and turbulent analysis. J Biomech 2002;35:1533-1540
    • (2002) J Biomech , vol.35 , pp. 1533-1540
    • Bluestein, D.1    Li, Y.2    Krukenkamp, I.B.3
  • 16
    • 0028414111 scopus 로고
    • Numerical simulation of unsteady laminar flow through a tilting disk heart valve: Prediction of vortex shedding
    • Huang ZJ, Merkle CL, Abdallah S, Tarbell JM. Numerical simulation of unsteady laminar flow through a tilting disk heart valve: Prediction of vortex shedding. J Biomech 1994;27:391-402
    • (1994) J Biomech , vol.27 , pp. 391-402
    • Huang, Z.J.1    Merkle, C.L.2    Abdallah, S.3    Tarbell, J.M.4
  • 17
    • 0035063176 scopus 로고    scopus 로고
    • The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves
    • Grigioni M, Daniele C, D'Avenio G, Barbara V. The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves. J Biomech 2001;34:613-621
    • (2001) J Biomech , vol.34 , pp. 613-621
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Barbara, V.4
  • 18
    • 0023811907 scopus 로고
    • A comparison of phospholipid and platelets in the activation of human factor VIII by thrombin and factor Xa, and in the activation of factor X
    • Neuenschwander P, Jesty J. A comparison of phospholipid and platelets in the activation of human factor VIII by thrombin and factor Xa, and in the activation of factor X. Blood 1988;76:1761-1770
    • (1988) Blood , vol.76 , pp. 1761-1770
    • Neuenschwander, P.1    Jesty, J.2
  • 19
    • 0033566160 scopus 로고    scopus 로고
    • The use of acetylated pro-thrombin as a substrate in the measurement of the procoagulant activity of platelets: Elimination of the feedback activation of platelets by thrombin
    • Jesty J, Bluestein D. The use of acetylated pro- thrombin as a substrate in the measurement of the procoagulant activity of platelets: Elimination of the feedback activation of platelets by thrombin. Anal Biochem 1999;272:64-70
    • (1999) Anal Biochem , vol.272 , pp. 64-70
    • Jesty, J.1    Bluestein, D.2
  • 20
    • 0038627711 scopus 로고    scopus 로고
    • Platelet activation in circulating flow loop: Combined effects of shear stress and exposure time
    • Jesty J, Yin W, Perrotta P, Bluestein D. Platelet activation in circulating flow loop: Combined effects of shear stress and exposure time. Platelets 2003;14:11-17
    • (2003) Platelets , vol.14 , pp. 11-17
    • Jesty, J.1    Yin, W.2    Perrotta, P.3    Bluestein, D.4
  • 22
    • 0033623705 scopus 로고    scopus 로고
    • In vitro cell shearing device to investigate the dynamic response of cells in a controlled hydrodynamic environment
    • Blackman BR, Barbee KA, Thibault LE. In vitro cell shearing device to investigate the dynamic response of cells in a controlled hydrodynamic environment. Ann Biomed Eng 2000;28:363-372
    • (2000) Ann Biomed Eng , vol.28 , pp. 363-372
    • Blackman, B.R.1    Barbee, K.A.2    Thibault, L.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.