메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 421-429

Early Clinical Results of a High-Flexion, Posterior-Stabilized, Mobile-Bearing Total Knee Arthroplasty. A US Investigational Device Exemption Trial.

Author keywords

High flexion mobile bearing and fixed bearing knees; Investigational device exemption trial; Total knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; FEMALE; FIXED BEARING KNEE; FOLLOW UP; HUMAN; IMPLANT; KNEE FUNCTION; KNEE SOCIETY ASSESSMENT AND FUNCTION SCORE; MAJOR CLINICAL STUDY; MALE; MOBILE BEARING KNEE; ORTHOPEDICS; POSTOPERATIVE COMPLICATION; PROSPECTIVE STUDY; RADIOGRAPHY; SCORING SYSTEM; SURVIVAL; TOTAL KNEE REPLACEMENT;

EID: 84857117760     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2011.06.011     Document Type: Article
Times cited : (20)

References (39)
  • 1
    • 52049086064 scopus 로고    scopus 로고
    • High-flexion total knee arthroplasty
    • 7
    • Long W.J., Scuderi G.R. High-flexion total knee arthroplasty. J Arthroplasty 2008, 23(7 Suppl):6.
    • (2008) J Arthroplasty , vol.23 , Issue.SUPPL. , pp. 6
    • Long, W.J.1    Scuderi, G.R.2
  • 3
    • 33749151610 scopus 로고    scopus 로고
    • The P.F.C. sigma RP-F TKA designed for improved performance: a matched-pair study
    • 9
    • Gupta S.K., Ranawat A.S., Shah V., et al. The P.F.C. sigma RP-F TKA designed for improved performance: a matched-pair study. Orthopedics 2006, 29(9 Suppl):S49.
    • (2006) Orthopedics , vol.29 , Issue.SUPPL.
    • Gupta, S.K.1    Ranawat, A.S.2    Shah, V.3
  • 4
    • 21444455369 scopus 로고    scopus 로고
    • Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study
    • Kim Y.H., Sohn K.S., Kim J.S. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am 2005, 87:1470.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1470
    • Kim, Y.H.1    Sohn, K.S.2    Kim, J.S.3
  • 5
    • 27744594858 scopus 로고    scopus 로고
    • Comparison of range of motion of high-flexion prosthesis and mobile-bearing prosthesis in total knee arthroplasty
    • 10
    • Seon J.K., Song E.K., Lee J.Y. Comparison of range of motion of high-flexion prosthesis and mobile-bearing prosthesis in total knee arthroplasty. Orthopedics 2005, 28(10 Suppl):s1247.
    • (2005) Orthopedics , vol.28 , Issue.SUPPL.
    • Seon, J.K.1    Song, E.K.2    Lee, J.Y.3
  • 6
    • 34047222100 scopus 로고    scopus 로고
    • Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery
    • Bin S.I., Nam T.S. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 2007, 15:350.
    • (2007) Knee Surg Sports Traumatol Arthrosc , vol.15 , pp. 350
    • Bin, S.I.1    Nam, T.S.2
  • 7
    • 23044441339 scopus 로고    scopus 로고
    • The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up
    • Huang H.T., Su J.Y., Wang G.J. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 2005, 20:674.
    • (2005) J Arthroplasty , vol.20 , pp. 674
    • Huang, H.T.1    Su, J.Y.2    Wang, G.J.3
  • 8
    • 53849148920 scopus 로고    scopus 로고
    • The NexGen LPS-flex to the knee prosthesis at a minimum of three years
    • Kim T.H., Lee D.H., Bin S.I. The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 2008, 90:1304.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1304
    • Kim, T.H.1    Lee, D.H.2    Bin, S.I.3
  • 9
    • 58249102104 scopus 로고    scopus 로고
    • Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement
    • Ng F.Y., Wong H.L., Yau W.P., et al. Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement. Int Orthop 2008, 32:795.
    • (2008) Int Orthop , vol.32 , pp. 795
    • Ng, F.Y.1    Wong, H.L.2    Yau, W.P.3
  • 10
    • 38749144044 scopus 로고    scopus 로고
    • A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components
    • Nutton R.W., van der Linden M.L., Rowe P.J., et al. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Joint Surg Br 2008, 90:37.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 37
    • Nutton, R.W.1    van der Linden, M.L.2    Rowe, P.J.3
  • 11
    • 54449095118 scopus 로고    scopus 로고
    • Patient-reported outcome correlates with knee function after a single-design mobile-bearing TKA
    • Argenson J.N., Parratte S., Ashour A., et al. Patient-reported outcome correlates with knee function after a single-design mobile-bearing TKA. Clin Orthop Relat Res 2008, 466:2669.
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 2669
    • Argenson, J.N.1    Parratte, S.2    Ashour, A.3
  • 12
    • 74249117351 scopus 로고    scopus 로고
    • Achieving deep flexion after primary total knee arthroplasty
    • Tarabichi S., Tarabichi Y., Hawari M. Achieving deep flexion after primary total knee arthroplasty. J Arthroplasty 2010, 25:219.
    • (2010) J Arthroplasty , vol.25 , pp. 219
    • Tarabichi, S.1    Tarabichi, Y.2    Hawari, M.3
  • 13
    • 56249120212 scopus 로고    scopus 로고
    • Clinical and radiological results of high flex total knee arthroplasty: a 5 year follow-up
    • Wohlrab D., Hube R., Zeh A., et al. Clinical and radiological results of high flex total knee arthroplasty: a 5 year follow-up. Arch Orthop Trauma Surg 2009, 129:21.
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 21
    • Wohlrab, D.1    Hube, R.2    Zeh, A.3
  • 14
    • 0032710278 scopus 로고    scopus 로고
    • An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics
    • Jones V.C., Barton D.C., Fitzpatrick D.P., et al. An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics. Biomed Mater Eng 1999, 9:189.
    • (1999) Biomed Mater Eng , vol.9 , pp. 189
    • Jones, V.C.1    Barton, D.C.2    Fitzpatrick, D.P.3
  • 15
    • 68649124107 scopus 로고    scopus 로고
    • Meta-analysis comparing outcomes of fixed-bearing and mobile-bearing prostheses in total knee arthroplasty
    • Oh K.J., Pandher D.S., Lee S.H., et al. Meta-analysis comparing outcomes of fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. J Arthroplasty 2009, 24:873.
    • (2009) J Arthroplasty , vol.24 , pp. 873
    • Oh, K.J.1    Pandher, D.S.2    Lee, S.H.3
  • 16
    • 77951296421 scopus 로고    scopus 로고
    • Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis
    • Smith T.O., Ejtehadi F., Nichols R., et al. Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2010, 18:325.
    • (2010) Knee Surg Sports Traumatol Arthrosc , vol.18 , pp. 325
    • Smith, T.O.1    Ejtehadi, F.2    Nichols, R.3
  • 17
    • 57749094144 scopus 로고    scopus 로고
    • High-flexion implants in primary total knee arthroplasty: a meta-analysis
    • Gandhi R., Tso P., Davey J.R., et al. High-flexion implants in primary total knee arthroplasty: a meta-analysis. Knee 2009, 16:14.
    • (2009) Knee , vol.16 , pp. 14
    • Gandhi, R.1    Tso, P.2    Davey, J.R.3
  • 18
    • 68349109649 scopus 로고    scopus 로고
    • High-flexion total knee arthroplasty: a systematic review
    • Murphy M., Journeaux S., Russell T. High-flexion total knee arthroplasty: a systematic review. Int Orthop 2009, 33:887.
    • (2009) Int Orthop , vol.33 , pp. 887
    • Murphy, M.1    Journeaux, S.2    Russell, T.3
  • 19
    • 10444232753 scopus 로고    scopus 로고
    • In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty
    • Argenson J.N., Scuderi G.R., Komistek R.D., et al. In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 2005, 38:277.
    • (2005) J Biomech , vol.38 , pp. 277
    • Argenson, J.N.1    Scuderi, G.R.2    Komistek, R.D.3
  • 20
    • 70349248428 scopus 로고    scopus 로고
    • Three-dimensional tibiofemoral kinematics during deep flexion kneeling in a mobile-bearing total knee arthroplasty
    • Nakamura E., Banks S.A., Tanaka A., et al. Three-dimensional tibiofemoral kinematics during deep flexion kneeling in a mobile-bearing total knee arthroplasty. J Arthroplasty 2009, 24:1120.
    • (2009) J Arthroplasty , vol.24 , pp. 1120
    • Nakamura, E.1    Banks, S.A.2    Tanaka, A.3
  • 22
    • 0037786606 scopus 로고    scopus 로고
    • Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis
    • Ritter M.A., Harty L.D., Davis K.E., et al. Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am 2003, 85-A:1278.
    • (2003) J Bone Joint Surg Am , pp. 1278
    • Ritter, M.A.1    Harty, L.D.2    Davis, K.E.3
  • 23
    • 0036992703 scopus 로고    scopus 로고
    • Review article: knee flexion after total knee arthroplasty
    • Chiu K.Y., Ng T.P., Tang W.M., et al. Review article: knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 2002, 10:194.
    • (2002) J Orthop Surg (Hong Kong) , vol.10 , pp. 194
    • Chiu, K.Y.1    Ng, T.P.2    Tang, W.M.3
  • 24
    • 0034962833 scopus 로고    scopus 로고
    • Does modularity affect clinical success? A comparison with a minimum 10-year follow up
    • Brassard M.F., Insall J.N., Scuderi G.R., et al. Does modularity affect clinical success? A comparison with a minimum 10-year follow up. Clin Orthop Relat Res 2001, 26.
    • (2001) Clin Orthop Relat Res , pp. 26
    • Brassard, M.F.1    Insall, J.N.2    Scuderi, G.R.3
  • 25
    • 0023098711 scopus 로고
    • Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines
    • Ecker M.L., Lotke P.A., Windsor R.E., et al. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 1987, 151.
    • (1987) Clin Orthop Relat Res , pp. 151
    • Ecker, M.L.1    Lotke, P.A.2    Windsor, R.E.3
  • 26
    • 33747881586 scopus 로고    scopus 로고
    • A third-generation, posterior-stabilized knee prosthesis: early results after follow-up of 2 to 6 years
    • Fuchs R., Mills E.L., Clarke H.D., et al. A third-generation, posterior-stabilized knee prosthesis: early results after follow-up of 2 to 6 years. J Arthroplasty 2006, 21:821.
    • (2006) J Arthroplasty , vol.21 , pp. 821
    • Fuchs, R.1    Mills, E.L.2    Clarke, H.D.3
  • 27
    • 46149096725 scopus 로고    scopus 로고
    • Radiolucent lines below the tibial component of a total knee replacement (TKR)-a comparison between single-and two-stage cementation techniques
    • Guha A.R., Debnath U.K., Graham N.M. Radiolucent lines below the tibial component of a total knee replacement (TKR)-a comparison between single-and two-stage cementation techniques. Int Orthop 2008, 32:453.
    • (2008) Int Orthop , vol.32 , pp. 453
    • Guha, A.R.1    Debnath, U.K.2    Graham, N.M.3
  • 28
    • 0035208810 scopus 로고    scopus 로고
    • Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years
    • Hartford J.M., Hunt T., Kaufer H. Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years. J Arthroplasty 2001, 16:977.
    • (2001) J Arthroplasty , vol.16 , pp. 977
    • Hartford, J.M.1    Hunt, T.2    Kaufer, H.3
  • 29
    • 84857119491 scopus 로고
    • The effect of position on the detection of radiolucent lines beneath the tibial tray
    • Magee F.P., Weinstein A.M. The effect of position on the detection of radiolucent lines beneath the tibial tray. Transactions 1986, 357.
    • (1986) Transactions , vol.357
    • Magee, F.P.1    Weinstein, A.M.2
  • 30
    • 33846069722 scopus 로고    scopus 로고
    • Press-fit condylar design total knee arthroplasty. Fourteen to seventeen-year follow-up
    • Rodricks D.J., Patil S., Pulido P., et al. Press-fit condylar design total knee arthroplasty. Fourteen to seventeen-year follow-up. J Bone Joint Surg Am 2007, 89:89.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 89
    • Rodricks, D.J.1    Patil, S.2    Pulido, P.3
  • 31
    • 33947153843 scopus 로고    scopus 로고
    • Medium-term results with the Press Fit Condylar (PFC) Sigma knee prosthesis. The Wrightington experience
    • Zaki S.H., Rafiq I., Kapoor A., et al. Medium-term results with the Press Fit Condylar (PFC) Sigma knee prosthesis. The Wrightington experience. Acta Orthop Belg 2007, 73:55.
    • (2007) Acta Orthop Belg , vol.73 , pp. 55
    • Zaki, S.H.1    Rafiq, I.2    Kapoor, A.3
  • 32
    • 36348935030 scopus 로고    scopus 로고
    • The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient
    • Kim Y.H., Yoon S.H., Kim J.S. The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient. J Bone Joint Surg Br 2007, 89:1317.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 1317
    • Kim, Y.H.1    Yoon, S.H.2    Kim, J.S.3
  • 33
    • 0034876674 scopus 로고    scopus 로고
    • Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years
    • Sorrells R.B., Stiehl J.B., Voorhorst P.E. Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years. Clin Orthop Relat Res 2001, 182.
    • (2001) Clin Orthop Relat Res , pp. 182
    • Sorrells, R.B.1    Stiehl, J.B.2    Voorhorst, P.E.3
  • 34
    • 71849120376 scopus 로고    scopus 로고
    • The incidence and results of manipulation after primary total knee arthroplasty
    • Rubinstein R.A., DeHaan A. The incidence and results of manipulation after primary total knee arthroplasty. Knee 2010, 17:29.
    • (2010) Knee , vol.17 , pp. 29
    • Rubinstein, R.A.1    DeHaan, A.2
  • 35
    • 47849098790 scopus 로고    scopus 로고
    • The results of knee manipulation for stiffness after total knee arthroplasty with or without an intra-articular steroid injection
    • Sharma V., Maheshwari A.V., Tsailas P.G., et al. The results of knee manipulation for stiffness after total knee arthroplasty with or without an intra-articular steroid injection. Indian J Orthop 2008, 42:314.
    • (2008) Indian J Orthop , vol.42 , pp. 314
    • Sharma, V.1    Maheshwari, A.V.2    Tsailas, P.G.3
  • 36
    • 0031868098 scopus 로고    scopus 로고
    • Participation in sports after total knee replacement
    • Bradbury N., Borton D., Spoo G., et al. Participation in sports after total knee replacement. Am J Sports Med 1998, 26:530.
    • (1998) Am J Sports Med , vol.26 , pp. 530
    • Bradbury, N.1    Borton, D.2    Spoo, G.3
  • 38
    • 33646193989 scopus 로고    scopus 로고
    • Hip, knee, and ankle kinematics of high range of motion activities of daily living
    • Hemmerich A., Brown H., Smith S., et al. Hip, knee, and ankle kinematics of high range of motion activities of daily living. J Orthop Res 2006, 24:770.
    • (2006) J Orthop Res , vol.24 , pp. 770
    • Hemmerich, A.1    Brown, H.2    Smith, S.3
  • 39
    • 0036849535 scopus 로고    scopus 로고
    • What functional activities are important to patients with knee replacements?
    • Weiss J.M., Noble P.C., Conditt M.A., et al. What functional activities are important to patients with knee replacements?. Clin Orthop Relat Res 2002, 172.
    • (2002) Clin Orthop Relat Res , pp. 172
    • Weiss, J.M.1    Noble, P.C.2    Conditt, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.