메뉴 건너뛰기




Volumn 13, Issue 1, 2011, Pages

Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: Head to head comparison and validation at 1.5 T and 3 T

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AORTA FLOW; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; CORONARY ARTERY BLOOD FLOW; FEMALE; HEART STROKE VOLUME; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; MALE; NORMAL HUMAN; PEAK EXPIRATORY FLOW; PRIORITY JOURNAL; PULMONARY ARTERY; QUANTITATIVE ANALYSIS; THREE DIMENSIONAL IMAGING; VALIDATION STUDY; AORTA; BLOOD FLOW; BLOOD FLOW VELOCITY; COMPARATIVE STUDY; LUNG CIRCULATION; METHODOLOGY; MYOCARDIAL PERFUSION IMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; PREDICTIVE VALUE; REFERENCE VALUE; REPRODUCIBILITY; STATISTICAL MODEL; SWEDEN; TIME;

EID: 84857015934     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-13-55     Document Type: Article
Times cited : (92)

References (35)
  • 1
    • 0029339826 scopus 로고
    • A segmented K-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding
    • 10.1002/jmri.1880050405 7549200
    • A segmented K-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding. Thomsen C, Cortsen M, Sondergaard L, Henriksen O, Stahlberg F, J Magn Reson Imaging 1995 5 393 401 10.1002/jmri.1880050405 7549200
    • (1995) J Magn Reson Imaging , vol.5 , pp. 393-401
    • Thomsen, C.1    Cortsen, M.2    Sondergaard, L.3    Henriksen, O.4    Stahlberg, F.5
  • 2
    • 51649099259 scopus 로고    scopus 로고
    • Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: Board of trustees task force on standardized protocols
    • 10.1186/1532-429X-10-35 18605997
    • Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols. Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E, J Cardiovasc Magn Reson 2008 10 35 10.1186/1532-429X-10-35 18605997
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 35
    • Kramer, C.M.1    Barkhausen, J.2    Flamm, S.D.3    Kim, R.J.4    Nagel, E.5
  • 3
    • 0033045531 scopus 로고    scopus 로고
    • Left-to-right cardiac shunts: Comparison of measurements obtained with MR velocity mapping and with radionuclide angiography
    • Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography. Arheden H, Holmqvist C, Thilen U, Hanseus K, Bjorkhem G, Pahlm O, Laurin S, Stahlberg F, Radiology 1999 211 453 458 10228528 (Pubitemid 29206815)
    • (1999) Radiology , vol.211 , Issue.2 , pp. 453-458
    • Arheden, H.1    Holmqvist, C.2    Thilen, U.3    Hanseus, K.4    Bjorkhem, G.5    Pahim, O.6    Laurin, S.7    Stahlberg, F.8
  • 4
    • 34547113317 scopus 로고    scopus 로고
    • The quantitative relationship between longitudinal and radial function in left, right, and total heart pumping in humans
    • DOI 10.1152/ajpheart.01376.2006
    • The quantitative relationship between longitudinal and radial function in left, right, and total heart pumping in humans. Carlsson M, Ugander M, Heiberg E, Arheden H, Am J Physiol Heart Circ Physiol 2007 293 636 644 10.1152/ajpheart.01376.2006 17307988 (Pubitemid 47105125)
    • (2007) American Journal of Physiology - Heart and Circulatory Physiology , vol.293 , Issue.1
    • Carlsson, M.1    Ugander, M.2    Heiberg, E.3    Arheden, H.4
  • 5
    • 77949314852 scopus 로고    scopus 로고
    • Flow measurement by cardiovascular magnetic resonance: A multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements
    • 10.1186/1532-429X-12-5 20074359
    • Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements. Gatehouse PD, Rolf MP, Graves MJ, Hofman MB, Totman J, Werner B, Quest RA, Liu Y, von Spiczak J, Dieringer M, et al. J Cardiovasc Magn Reson 2010 12 5 10.1186/1532-429X-12-5 20074359
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 5
    • Gatehouse, P.D.1    Rolf, M.P.2    Graves, M.J.3    Hofman, M.B.4    Totman, J.5    Werner, B.6    Quest, R.A.7    Liu, Y.8    Von Spiczak, J.9    Dieringer, M.10
  • 7
    • 79953304124 scopus 로고    scopus 로고
    • Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
    • 10.1186/1532-429X-13-7 21235751
    • Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. Markl M, Kilner PJ, Ebbers T, J Cardiovasc Magn Reson 2011 13 7 10.1186/1532-429X-13-7 21235751
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 7
    • Markl, M.1    Kilner, P.J.2    Ebbers, T.3
  • 8
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI With High Frame Rate Exploiting Spatiotemporal Correlations
    • DOI 10.1002/mrm.10611
    • k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Tsao J, Boesiger P, Pruessmann KP, Magn Reson Med 2003 50 1031 1042 10.1002/mrm.10611 14587014 (Pubitemid 37356583)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.5 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 10
    • 65249130632 scopus 로고    scopus 로고
    • Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST with SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta
    • 10.1002/jmri.21706 19306404
    • Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST With SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta. Stadlbauer A, van der Riet W, Globits S, Crelier G, Salomonowitz E, Journal of Magnetic Resonance Imaging 2009 29 817 824 10.1002/jmri.21706 19306404
    • (2009) Journal of Magnetic Resonance Imaging , vol.29 , pp. 817-824
    • Stadlbauer, A.1    Van Der Riet, W.2    Globits, S.3    Crelier, G.4    Salomonowitz, E.5
  • 11
    • 31944438177 scopus 로고    scopus 로고
    • Feasibility of k-t BLAST technique for measuring "seven- dimensional" fluid flow
    • DOI 10.1002/jmri.20494
    • Feasibility of k-t BLAST technique for measuring "seven- dimensional" fluid flow. Marshall I, J Magn Reson Imaging 2006 23 189 196 10.1002/jmri.20494 16416437 (Pubitemid 43191073)
    • (2006) Journal of Magnetic Resonance Imaging , vol.23 , Issue.2 , pp. 189-196
    • Marshall, I.1
  • 12
    • 77953872385 scopus 로고    scopus 로고
    • Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-t BLAST
    • 19581063
    • Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-t BLAST. Stadlbauer A, van der Riet W, Crelier G, Salomonowitz E, European Journal of Radiology 2010 75 15 E21 19581063
    • (2010) European Journal of Radiology , vol.75
    • Stadlbauer, A.1    Van Der Riet, W.2    Crelier, G.3    Salomonowitz, E.4
  • 13
    • 58149188386 scopus 로고    scopus 로고
    • Mitral valve and tricuspid valve blood flow: Accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking
    • 10.1148/radiol.2492080146 18849503
    • Mitral valve and tricuspid valve blood flow: accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking. Westenberg JJ, Roes SD, Ajmone Marsan N, Binnendijk NM, Doornbos J, Bax JJ, Reiber JH, de Roos A, van der Geest RJ, Radiology 2008 249 792 800 10.1148/radiol.2492080146 18849503
    • (2008) Radiology , vol.249 , pp. 792-800
    • Westenberg, J.J.1    Roes, S.D.2    Ajmone Marsan, N.3    Binnendijk, N.M.4    Doornbos, J.5    Bax, J.J.6    Reiber, J.H.7    De Roos, A.8    Van Der Geest, R.J.9
  • 14
    • 17844403299 scopus 로고    scopus 로고
    • In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal-to-noise ratios
    • DOI 10.1002/jmri.20275
    • In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios. Lotz J, Doker R, Noeske R, Schuttert M, Felix R, Galanski M, Gutberlet M, Meyer GP, J Magn Reson Imaging 2005 21 604 610 10.1002/jmri.20275 15834905 (Pubitemid 40586760)
    • (2005) Journal of Magnetic Resonance Imaging , vol.21 , Issue.5 , pp. 604-610
    • Lotz, J.1    Doker, R.2    Noeske, R.3    Schuttert, M.4    Felix, R.5    Galanski, M.6    Gutberlet, M.7    Meyer, G.P.8
  • 15
    • 51449112368 scopus 로고    scopus 로고
    • Assessment of fluctuating velocities in disturbed cardiovascular blood flow: In vivo feasibility of generalized phase-contrast MRI
    • 10.1002/jmri.21475 18777557
    • Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. Dyverfeldt P, Kvitting JP, Sigfridsson A, Engvall J, Bolger AF, Ebbers T, J Magn Reson Imaging 2008 28 655 663 10.1002/jmri.21475 18777557
    • (2008) J Magn Reson Imaging , vol.28 , pp. 655-663
    • Dyverfeldt, P.1    Kvitting, J.P.2    Sigfridsson, A.3    Engvall, J.4    Bolger, A.F.5    Ebbers, T.6
  • 16
    • 76949088162 scopus 로고    scopus 로고
    • Design and validation of Segment - Freely available software for cardiovascular image analysis
    • 10.1186/1471-2342-10-1 20064248
    • Design and validation of Segment - freely available software for cardiovascular image analysis. Heiberg E, Sjogren J, Ugander M, Carlsson M, Engblom H, Arheden H, BMC Med Imaging 2010 10 1 10.1186/1471-2342-10-1 20064248
    • (2010) BMC Med Imaging , vol.10 , pp. 1
    • Heiberg, E.1    Sjogren, J.2    Ugander, M.3    Carlsson, M.4    Engblom, H.5    Arheden, H.6
  • 17
    • 24144470505 scopus 로고    scopus 로고
    • Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil
    • DOI 10.1002/mrm.20636
    • Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil. Reeder SB, Wintersperger BJ, Dietrich O, Lanz T, Greiser A, Reiser MF, Glazer GM, Schoenberg SO, Magn Reson Med 2005 54 748 754 10.1002/mrm.20636 16088885 (Pubitemid 41233774)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.3 , pp. 748-754
    • Reeder, S.B.1    Wintersperger, B.J.2    Dietrich, O.3    Lanz, T.4    Greiser, A.5    Reiser, M.F.6    Glazer, G.M.7    Schoenberg, S.O.8
  • 20
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • DOI 10.1097/00004728-200407000-00005
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. Markl M, Draney MT, Hope MD, Levin JM, Chan FP, Alley MT, Pelc NJ, Herfkens RJ, J Comput Assist Tomogr 2004 28 459 468 10.1097/00004728-200407000- 00005 15232376 (Pubitemid 38988812)
    • (2004) Journal of Computer Assisted Tomography , vol.28 , Issue.4 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3    Levin, J.M.4    Chan, F.P.5    Alley, M.T.6    Pelc, N.J.7    Herfkens, R.J.8
  • 21
    • 55749085612 scopus 로고    scopus 로고
    • Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters
    • 10.1002/mrm.21778 18956416
    • Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M, Magn Reson Med 2008 60 1218 1231 10.1002/mrm.21778 18956416
    • (2008) Magn Reson Med , vol.60 , pp. 1218-1231
    • Stalder, A.F.1    Russe, M.F.2    Frydrychowicz, A.3    Bock, J.4    Hennig, J.5    Markl, M.6
  • 22
    • 77956128260 scopus 로고    scopus 로고
    • Tetralogy of fallot: 3D velocity-encoded MR imaging for evaluation of right ventricular valve flow and diastolic function in patients after correction
    • 10.1148/radiol.10092269 20634432
    • Tetralogy of fallot: 3D velocity-encoded MR imaging for evaluation of right ventricular valve flow and diastolic function in patients after correction. van der Hulst AE, Westenberg JJ, Kroft LJ, Bax JJ, Blom NA, de Roos A, Roest AA, Radiology 2010 256 724 734 10.1148/radiol.10092269 20634432
    • (2010) Radiology , vol.256 , pp. 724-734
    • Van Der Hulst, A.E.1    Westenberg, J.J.2    Kroft, L.J.3    Bax, J.J.4    Blom, N.A.5    De Roos, A.6    Roest, A.A.7
  • 23
    • 67049137997 scopus 로고    scopus 로고
    • Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: Comparison of flow measurements from 3D and 2D acquisitions
    • 10.1186/1532-429X-11-3 19232119
    • Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions. Brix L, Ringgaard S, Rasmusson A, Sorensen TS, Kim WY, J Cardiovasc Magn Reson 2009 11 3 10.1186/1532-429X-11-3 19232119
    • (2009) J Cardiovasc Magn Reson , vol.11 , pp. 3
    • Brix, L.1    Ringgaard, S.2    Rasmusson, A.3    Sorensen, T.S.4    Kim, W.Y.5
  • 24
    • 57149120524 scopus 로고    scopus 로고
    • Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR
    • 10.1002/mrm.21763 19025882
    • Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR. Johnson KM, Lum DP, Turski PA, Block WF, Mistretta CA, Wieben O, Magn Reson Med 2008 60 1329 1336 10.1002/mrm.21763 19025882
    • (2008) Magn Reson Med , vol.60 , pp. 1329-1336
    • Johnson, K.M.1    Lum, D.P.2    Turski, P.A.3    Block, W.F.4    Mistretta, C.A.5    Wieben, O.6
  • 26
    • 78651496022 scopus 로고    scopus 로고
    • Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: Comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging
    • 10.3174/ajnr.A2457 20947642
    • Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging. Chang W, Landgraf B, Johnson KM, Kecskemeti S, Wu Y, Velikina J, Rowley H, Wieben O, Mistretta C, Turski P, AJNR Am J Neuroradiol 2011 32 54 59 10.3174/ajnr.A2457 20947642
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 54-59
    • Chang, W.1    Landgraf, B.2    Johnson, K.M.3    Kecskemeti, S.4    Wu, Y.5    Velikina, J.6    Rowley, H.7    Wieben, O.8    Mistretta, C.9    Turski, P.10
  • 27
    • 77950372132 scopus 로고    scopus 로고
    • Bicuspid aortic valve: Four-dimensional MR evaluation of ascending aortic systolic flow patterns
    • 10.1148/radiol.09091437 20308444
    • Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns. Hope MD, Hope TA, Meadows AK, Ordovas KG, Urbania TH, Alley MT, Higgins CB, Radiology 2010 255 53 61 10.1148/radiol.09091437 20308444
    • (2010) Radiology , vol.255 , pp. 53-61
    • Hope, M.D.1    Hope, T.A.2    Meadows, A.K.3    Ordovas, K.G.4    Urbania, T.H.5    Alley, M.T.6    Higgins, C.B.7
  • 31
    • 79958031481 scopus 로고    scopus 로고
    • Quantification of presystolic blood flow organization and energetics in the human left ventricle
    • 10.1152/ajpheart.00993.2010 21421820
    • Quantification of presystolic blood flow organization and energetics in the human left ventricle. Eriksson J, Dyverfeldt P, Engvall J, Bolger AF, Ebbers T, Carlhall CJ, Am J Physiol Heart Circ Physiol 2011 300 2135 2141 10.1152/ajpheart.00993.2010 21421820
    • (2011) Am J Physiol Heart Circ Physiol , vol.300 , pp. 82135-82141
    • Eriksson, J.1    Dyverfeldt, P.2    Engvall, J.3    Bolger, A.F.4    Ebbers, T.5    Carlhall, C.J.6
  • 32
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • DOI 10.1002/mrm.20713
    • Image reconstruction in SNR units: a general method for SNR measurement. Kellman P, McVeigh ER, Magn Reson Med 2005 54 1439 1447 10.1002/mrm.20713 16261576 (Pubitemid 41740773)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.6 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2
  • 33
  • 35
    • 79954583890 scopus 로고    scopus 로고
    • Retrospectively gated cardiac cine imaging with temporal and spatial acceleration
    • 10.1016/j.mri.2011.01.003 21398063
    • Retrospectively gated cardiac cine imaging with temporal and spatial acceleration. Madore B, Hoge WS, Chao TC, Zientara GP, Chu R, Magn Reson Imaging 2011 29 457 469 10.1016/j.mri.2011.01.003 21398063
    • (2011) Magn Reson Imaging , vol.29 , pp. 457-469
    • Madore, B.1    Hoge, W.S.2    Chao, T.C.3    Zientara, G.P.4    Chu, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.