메뉴 건너뛰기




Volumn 11, Issue 1, 2009, Pages

Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: Comparison of flow measurements from 3D and 2D acquisitions

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANISOTROPY; AORTA FLOW; ARTICLE; ASCENDING AORTA; CARDIOVASCULAR SYSTEM EXAMINATION; COMPARATIVE STUDY; COMPUTER PROGRAM; CONTROLLED STUDY; ELECTROCARDIOGRAM; FEMALE; FLOW MEASUREMENT; FLOW RATE; HUMAN; IN VITRO STUDY; IN VIVO STUDY; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PULMONARY VALVE; QUANTITATIVE ANALYSIS; RESPIRATORY AIRFLOW; RETROSPECTIVE STUDY; STEADY STATE; THREE DIMENSIONAL IMAGING; VALVULAR HEART DISEASE; BLOOD FLOW VELOCITY; CORONARY ARTERY BLOOD FLOW; METHODOLOGY;

EID: 67049137997     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-11-3     Document Type: Article
Times cited : (49)

References (24)
  • 1
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M: Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002, 22: 651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 2
    • 0023199386 scopus 로고
    • Magnetic resonance velocity mapping: Clinical application of a new technique
    • Underwood SR, Firmin DN, Klipstein RH, Rees RS, Longmore DB: Magnetic resonance velocity mapping: clinical application of a new technique. Br Heart J 1987, 57: 404-412. (Pubitemid 17069264)
    • (1987) British Heart Journal , vol.57 , Issue.5 , pp. 404-412
    • Underwood, S.R.1    Firmin, D.N.2    Klipstein, R.H.3
  • 4
    • 0029964796 scopus 로고    scopus 로고
    • Temporally resolved 3D phase-contrast imaging
    • DOI 10.1002/mrm.1910360521
    • Wigstrom L, Sjoqvist L, Wranne B: Temporally resolved 3D phase-contrast imaging. Magn Reson Med 1996, 36: 800-803. (Pubitemid 26376721)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.5 , pp. 800-803
    • Wigstrom, L.1    Sjoqvist, L.2    Wranne, B.3
  • 6
    • 21244487801 scopus 로고    scopus 로고
    • Three-dimensional, isotropic MRI: A unified approach to quantification and visualization in congenital heart disease
    • DOI 10.1007/s10554-004-4018-x
    • Sorensen TS, Beerbaum P, Korperich H, Pedersen EM: Threedimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease. Int J Cardiovasc Imaging 2005, 21: 283-292. (Pubitemid 40895335)
    • (2005) International Journal of Cardiovascular Imaging , vol.21 , Issue.2-3 , pp. 283-292
    • Sorensen, T.S.1    Beerbaum, P.2    Korperich, H.3    Pedersen, E.M.4
  • 8
    • 0035028867 scopus 로고    scopus 로고
    • Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping
    • DOI 10.1002/jmri.1097
    • Kozerke S, Hasenkam JM, Pedersen EM, Boesiger P: Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping. J Magn Reson Imaging 2001, 13: 690-698. (Pubitemid 32381846)
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , Issue.5 , pp. 690-698
    • Kozerke, S.1    Michael Hasenkam, J.2    Pedersen, E.M.3    Boesiger, P.4
  • 9
    • 0031397482 scopus 로고    scopus 로고
    • Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: The effects of age and coronary artery disease
    • Bogren HG, Mohiaddin RH, Kilner PJ, Jimenez-Borreguero LJ, Yang GZ, Firmin DN: Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: the effects of age and coronary artery disease. J Magn Reson Imaging 1997, 7: 784-793.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 784-793
    • Bogren, H.G.1    Mohiaddin, R.H.2    Kilner, P.J.3    Jimenez-Borreguero, L.J.4    Yang, G.Z.5    Firmin, D.N.6
  • 10
    • 37349004799 scopus 로고    scopus 로고
    • Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    • DOI 10.1002/jmri.21082
    • Hope TA, Markl M, Wigstrom L, Alley MT, Miller DC, Herfkens RJ: Comparison of flow patterns in ascending aortic aneurysmsand volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 2007, 26: 1471-1479. (Pubitemid 350291274)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.6 , pp. 1471-1479
    • Hope, T.A.1    Markl, M.2    Wigstrom, L.3    Alley, M.T.4    Miller, D.C.5    Herfkens, R.J.6
  • 12
    • 0031830533 scopus 로고    scopus 로고
    • Visualizing blood flow patterns using streamlines, arrows, and particle paths
    • Buonocore MH: Visualizing blood flow patterns using streamlines, arrows, and particle paths. Magn Reson Med 1998, 40: 210-226.
    • (1998) Magn Reson Med , vol.40 , pp. 210-226
    • Buonocore, M.H.1
  • 14
    • 33846158142 scopus 로고    scopus 로고
    • Time-resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging
    • DOI 10.1002/mrm.21109
    • Bammer R, Hope TA, Aksoy M, Alley MT: Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5 T and 3.0 T in combination with parallel imaging. Magn Reson Med 2007, 57: 127-140. (Pubitemid 46075031)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.1 , pp. 127-140
    • Bammer, R.1    Hope, T.A.2    Aksoy, M.3    Alley, M.T.4
  • 16
    • 0032950758 scopus 로고    scopus 로고
    • Construction of a protocol for measuring blood flow by two-dimensional phasecontrast MRA
    • Bakker CJ, Hoogeveen RM, Viergever MA: Construction of a protocol for measuring blood flow by two-dimensional phasecontrast MRA. J Magn Reson Imaging 1999, 9: 119-127.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 119-127
    • Bakker, C.J.1    Hoogeveen, R.M.2    Viergever, M.A.3
  • 19
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • DOI 10.1097/00004728-200407000-00005
    • Markl M, Draney MT, Hope MD, Levin JM, Chan FP, Alley MT, Pelc NJ, Herfkens RJ: Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. J Comput Assist Tomogr 2004, 28: 459-468. (Pubitemid 38988812)
    • (2004) Journal of Computer Assisted Tomography , vol.28 , Issue.4 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3    Levin, J.M.4    Chan, F.P.5    Alley, M.T.6    Pelc, N.J.7    Herfkens, R.J.8
  • 20
    • 3142774861 scopus 로고    scopus 로고
    • Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: A validation study
    • DOI 10.1161/01.CIR.0000134282.35183.AD
    • Sørensen TS, Körperich H, Greil GF, Eichhorn J, Barth P, Meyer H, Pedersen EM, Beerbaum P: Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study. Circulation 2004, 110: 163-169. (Pubitemid 38924584)
    • (2004) Circulation , vol.110 , Issue.2 , pp. 163-169
    • Sorensen, T.S.1    Korperich, H.2    Greil, G.F.3    Eichhorn, J.4    Barth, P.5    Meyer, H.6    Pedersen, E.M.7    Beerbaum, P.8
  • 22
    • 4444266832 scopus 로고    scopus 로고
    • Reduced data acquisition methods in cardiac imaging
    • DOI 10.1097/01.rmr.0000132789.84706.9d
    • Kozerke S, Tsao J: Reduced data acquisition methods in cardiac imaging. Top Magn Reson Imaging 2004, 15: 161-168. (Pubitemid 39187203)
    • (2004) Topics in Magnetic Resonance Imaging , vol.15 , Issue.3 , pp. 161-168
    • Kozerke, S.1    Tsao, J.2
  • 24
    • 0029000972 scopus 로고
    • Vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels
    • Hofman MB, Visser FC, van Rossum AC, Vink QM, Sprenger M, Westerhof N: In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels. Magn Reson Med 1995, 33: 778-784.
    • (1995) Magn Reson Med , vol.33 , pp. 778-784
    • Hofman, M.B.1    Visser, F.C.2    Van Rossum, A.C.3    Vink, Q.M.4    Sprenger, M.5    Westerhof, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.