-
1
-
-
0036845747
-
Predictors of cancer in repeat extended multisite prostate biopsy in men with previous negative extended multisite biopsy
-
DOI 10.1016/S0090-4295(02)01950-7, PII S0090429502019507
-
BM Mian Y Naya K Okihara, et al. 2002 Predictors of cancer in repeat extended multisite prostate biopsy in men with previous negative extended multisite biopsy Urology 60 836 840 12429311 10.1016/S0090-4295(02)01950-7 (Pubitemid 35300350)
-
(2002)
Urology
, vol.60
, Issue.5
, pp. 836-840
-
-
Mian, B.M.1
Naya, Y.2
Okihara, K.3
Vakar-Lopez, F.4
Troncoso, P.5
Babaian R.Joseph6
-
2
-
-
0036090461
-
Serial biopsy results in prostate cancer screening study
-
KA Roehl JA Antenor WJ Catalona 2002 Serial biopsy results in prostate cancer screening study J Urol 167 2435 2439 11992052 10.1016/S0022-5347(05) 64999-3 (Pubitemid 34533140)
-
(2002)
Journal of Urology
, vol.167
, Issue.6
, pp. 2435-2439
-
-
Roehl, K.A.1
Antenor, J.A.V.2
Catalona, W.J.3
-
3
-
-
73749085789
-
Magnetic resonance imaging guided prostate biopsy in men with repeat negative biopsies and increased prostate specific antigen
-
20006859 10.1016/j.juro.2009.10.022 1:CAS:528:DC%2BC3cXitVSrt7c%3D
-
T Hambrock DM Somford C Hoeks, et al. 2010 Magnetic resonance imaging guided prostate biopsy in men with repeat negative biopsies and increased prostate specific antigen J Urol 183 520 527 20006859 10.1016/j.juro.2009.10.022 1:CAS:528:DC%2BC3cXitVSrt7c%3D
-
(2010)
J Urol
, vol.183
, pp. 520-527
-
-
Hambrock, T.1
Somford, D.M.2
Hoeks, C.3
-
4
-
-
77956303151
-
The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies
-
20964192 10.1118/1.3475945
-
MG Schouten J Ansems WKJ Renema, et al. 2010 The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies Med Phys 37 4744 4750 20964192 10.1118/1.3475945
-
(2010)
Med Phys
, vol.37
, pp. 4744-4750
-
-
Schouten, M.G.1
Ansems, J.2
Renema, W.K.J.3
-
5
-
-
0027401642
-
Localized prostate cancer: Relationship of tumor volume to clinical significance for treatment of prostate cancer
-
TA Stamey FS Freiha JE McNeal, et al. 1993 Localized prostate cancer. Relationship of tumor volume to clinical significance for treatment of prostate cancer Cancer 71 933 938 7679045 10.1002/1097-0142(19930201)71:3+<933::AID- CNCR2820711408>3.0.CO;2-L 1:STN:280:DyaK3s7ltlOntQ%3D%3D (Pubitemid 23049614)
-
(1993)
Cancer
, vol.71
, Issue.3 SUPPL.
, pp. 933-938
-
-
Stamey, T.A.1
Freiha, F.S.2
McNeal, J.E.3
Redwine, E.A.4
Whittemore, A.S.5
Schmid, H.-P.6
-
6
-
-
0242384764
-
Prostate gland motion and deformation caused by needle placement during brachytherapy
-
DOI 10.1016/S1538-4721(02)00058-2, PII S1538472102000582
-
NN Stone J Roy S Hong, et al. 2002 Prostate gland motion and deformation caused by needle placement during brachytherapy Brachytherapy 1 154 160 15090279 10.1016/S1538-4721(02)00058-2 (Pubitemid 37356902)
-
(2002)
Brachytherapy
, vol.1
, Issue.3
, pp. 154-160
-
-
Stone, N.N.1
Roy, J.2
Hong, S.3
Lo, Y.-C.4
Stock, R.G.5
-
7
-
-
28944433167
-
Measurement of prostate rotation during insertion of needles for brachytherapy
-
DOI 10.1016/j.radonc.2005.09.018, PII S0167814005004299
-
V Lagerburg MA Moerland JJ Lagendijk, et al. 2005 Measurement of prostate rotation during insertion of needles for brachytherapy Radiother Oncol 77 318 323 16289399 10.1016/j.radonc.2005.09.018 (Pubitemid 41785343)
-
(2005)
Radiotherapy and Oncology
, vol.77
, Issue.3
, pp. 318-323
-
-
Lagerburg, V.1
Moerland, M.A.2
Lagendijk, J.J.W.3
Battermann, J.J.4
-
8
-
-
0034653819
-
Needle displacement during HDR brachytherapy in the treatment of prostate cancer
-
DOI 10.1016/S0360-3016(99)00477-0, PII S0360301699004770
-
SJ Damore AM Syed AA Puthawala, et al. 2000 Needle displacement during HDR brachytherapy in the treatment of prostate cancer Int J Radiat Oncol Biol Phys 46 1205 1211 10725633 10.1016/S0360-3016(99)00477-0 1:STN:280: DC%2BD3c7ptFOksg%3D%3D (Pubitemid 30139432)
-
(2000)
International Journal of Radiation Oncology Biology Physics
, vol.46
, Issue.5
, pp. 1205-1211
-
-
Damore, S.J.1
Syed, A.M.N.2
Puthawala, A.A.3
Sharma, A.4
-
9
-
-
79959556966
-
Feasibility of a pneumatically actuated mr-compatible robot for transrectal prostate biopsy guidance
-
doi: 10.1148/radiol.11101106
-
Yakar D, Schouten MG, Bosboom DG et al (2011) Feasibility of a pneumatically actuated mr-compatible robot for transrectal prostate biopsy guidance. Radiology. doi: 10.1148/radiol.11101106
-
(2011)
Radiology
-
-
Yakar, D.1
Schouten, M.G.2
Bosboom, D.G.3
-
10
-
-
37349032479
-
Interactive frontend (IFE): A platform for graphical MR scanner control and scan automation
-
SR Lorenz KJ Kirchberg S Zuehlsdorff, et al. 2005 Interactive frontend (IFE): a platform for graphical MR scanner control and scan automation Proc Intl Soc Mag Reson Med 13 2170
-
(2005)
Proc Intl Soc Mag Reson Med
, vol.13
, pp. 2170
-
-
Lorenz, S.R.1
Kirchberg, K.J.2
Zuehlsdorff, S.3
-
11
-
-
38949092065
-
Pulse sequences and system interfaces for interventional and real-time MRI
-
DOI 10.1002/jmri.21268
-
SR Yutzy JL Duerk 2008 Pulse sequences and system interfaces for interventional and real-time MRI J Magn Reson Imaging 27 267 275 18219681 10.1002/jmri.21268 (Pubitemid 351214036)
-
(2008)
Journal of Magnetic Resonance Imaging
, vol.27
, Issue.2
, pp. 267-275
-
-
Yutzy, S.R.1
Duerk, J.L.2
-
12
-
-
12344276502
-
MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: Initial results
-
DOI 10.1148/radiol.2342031887
-
D Beyersdorff A Winkel B Hamm, et al. 2005 MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results Radiology 234 576 581 15616117 10.1148/radiol.2342031887 (Pubitemid 40139933)
-
(2005)
Radiology
, vol.234
, Issue.2
, pp. 576-581
-
-
Beyersdorff, D.1
Winkel, A.2
Hamm, B.3
Lenk, S.4
Loening, S.A.5
Taupitz, M.6
-
13
-
-
20744456885
-
Prostate cancer: Precision of integrating functional MR imaging with radiation therapy treatment by using fiducial gold markers
-
DOI 10.1148/radiol.2361040560
-
HJ Huisman JJ Fütterer EN van Lin, et al. 2005 Prostate cancer: precision of integrating functional MR imaging with radiation therapy treatment by using fiducial gold markers Radiology 236 311 317 15983070 10.1148/radiol.2361040560 (Pubitemid 40853328)
-
(2005)
Radiology
, vol.236
, Issue.1
, pp. 311-317
-
-
Huisman, H.J.1
Futterer, J.J.2
Van Lin, E.N.J.T.3
Welmers, A.4
Scheenen, T.W.J.5
Van Dalen, J.A.6
Visser, A.G.7
Witjes, J.A.8
Barentsz, J.O.9
-
14
-
-
46349109295
-
MRI-compatible pneumatic robot for transperineal prostate needle placement
-
10.1109/TMECH.2008.924044
-
GS Fischer I Iordachita C Csoma, et al. 2008 MRI-compatible pneumatic robot for transperineal prostate needle placement IEEE/ASME Trans Mechatron 13 295 305 10.1109/TMECH.2008.924044
-
(2008)
IEEE/ASME Trans Mechatron
, vol.13
, pp. 295-305
-
-
Fischer, G.S.1
Iordachita, I.2
Csoma, C.3
-
15
-
-
72049085532
-
Integrated navigation and control software system for MRI-guided robotic prostate interventions
-
19699057 10.1016/j.compmedimag.2009.07.004
-
J Tokuda GS Fischer SP DiMaio, et al. 2010 Integrated navigation and control software system for MRI-guided robotic prostate interventions Comput Med Imaging Graph 34 3 8 19699057 10.1016/j.compmedimag.2009.07.004
-
(2010)
Comput Med Imaging Graph
, vol.34
, pp. 3-8
-
-
Tokuda, J.1
Fischer, G.S.2
Dimaio, S.P.3
-
16
-
-
44449165969
-
Transperineal prostate intervention: Robot for fully automated MR imaging-system description and proof of principle in a canine model
-
18430882 10.1148/radiol.2472070737
-
M Muntener A Patriciu D Petrisor, et al. 2008 Transperineal prostate intervention: robot for fully automated MR imaging-system description and proof of principle in a canine model Radiology 247 543 549 18430882 10.1148/radiol.2472070737
-
(2008)
Radiology
, vol.247
, pp. 543-549
-
-
Muntener, M.1
Patriciu, A.2
Petrisor, D.3
-
17
-
-
76849094511
-
MRI-guided robotic system for transperineal prostate interventions: Proof of principle
-
20145293 10.1088/0031-9155/55/5/N02
-
MR van den Bosch MR Moman VM van Vulpen, et al. 2010 MRI-guided robotic system for transperineal prostate interventions: proof of principle Phys Med Biol 55 N133 N140 20145293 10.1088/0031-9155/55/5/N02
-
(2010)
Phys Med Biol
, vol.55
-
-
Van Den Bosch, M.R.1
Moman, M.R.2
Van Vulpen, V.M.3
-
18
-
-
79956294511
-
MR-compatible assistance system for biopsy in a high-field-strength system: Initial results in patients with suspicious prostate lesions
-
10.1148/radiol.11101559
-
S Zangos A Melzer K Eichler 2011 MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions Radiology 59 903 10 10.1148/radiol.11101559
-
(2011)
Radiology
, vol.59
, pp. 903-10
-
-
Zangos, S.1
Melzer, A.2
Eichler, K.3
-
19
-
-
78349236679
-
Accuracy validation for MRI-guided robotic prostate biopsy
-
Xu H, Lasso A, Vikal S et al (2010) Accuracy validation for MRI-guided robotic prostate biopsy. Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling 7625:762517-762518
-
(2010)
Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling
, vol.7625
, pp. 762517-762518
-
-
Xu, H.1
Lasso, A.2
Vikal, S.3
-
20
-
-
84858080901
-
MR to ultrasound registration for image-guided prostate interventions
-
doi: 10.1016/j.media.2010.11.003
-
Hu Y, Ahmed HU, Taylor Z et al (2010) MR to ultrasound registration for image-guided prostate interventions. Med Image Anal. doi: 10.1016/j.media.2010. 11.003
-
(2010)
Med Image Anal
-
-
Hu, Y.1
Ahmed, H.U.2
Taylor, Z.3
-
21
-
-
75749104198
-
Assessment of image registration accuracy in three dimensional transrectal iltrasound guided biopsy
-
20229890 10.1118/1.3298010 1:STN:280:DC%2BC3c7osFWitw%3D%3D
-
VV Karnik A Fenster J Bax, et al. 2010 Assessment of image registration accuracy in three dimensional transrectal iltrasound guided biopsy Med Phys 37 802 813 20229890 10.1118/1.3298010 1:STN:280:DC%2BC3c7osFWitw%3D%3D
-
(2010)
Med Phys
, vol.37
, pp. 802-813
-
-
Karnik, V.V.1
Fenster, A.2
Bax, J.3
-
23
-
-
40449085818
-
Initial clinical experience with real-time transrectal ultrasonography- magnetic resonance imaging fusion-guided prostate biopsy
-
DOI 10.1111/j.1464-410X.2007.07348.x
-
AK Singh J Kruecker S Xu, et al. 2008 Initial clinical experience with real-time transrectal ultrasonography-magnetic resonance imaging fusion-guided prostate biopsy BJU Int 101 842 845 10.1111/j.1464-410X.2007.07348.x (Pubitemid 351347719)
-
(2008)
BJU International
, vol.101
, Issue.7
, pp. 841-845
-
-
Singh, A.K.1
Kruecker, J.2
Xu, S.3
Glossop, N.4
Guion, P.5
Ullman, K.6
Choyke, P.L.7
Wood, B.J.8
-
24
-
-
58149392649
-
Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: Technique and feasibility
-
18791410 10.1097/RLI.0b013e31817d0506
-
T Hambrock JJ Fütterer HJ Huisman, et al. 2008 Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility Invest Radiol 43 686 694 18791410 10.1097/RLI.0b013e31817d0506
-
(2008)
Invest Radiol
, vol.43
, pp. 686-694
-
-
Hambrock, T.1
Fütterer, J.J.2
Huisman, H.J.3
-
25
-
-
78650824222
-
Target motion compensation in MRI-Guided prostate biopsy with static images. EMBS Engineering in Medicine and Biology Society (EMBC)
-
doi: 10.1109
-
Tadayyon H, Lasso A, Gill S et al (2010) Target motion compensation in MRI-Guided prostate biopsy with static images. EMBS Engineering in Medicine and Biology Society (EMBC), Annual International Conference 2010:5416-5419, doi: 10.1109
-
(2010)
Annual International Conference 2010
, pp. 5416-5419
-
-
Tadayyon, H.1
Lasso, A.2
Gill, S.3
-
26
-
-
59049086557
-
The importance of organ geometry and boundary constraints for planning of medical interventions
-
18815068 10.1016/j.medengphy.2008.08.002 1:STN:280:DC%2BD1M7itlCnsw%3D%3D
-
S Misra KJ Macura KT Ramesh, et al. 2009 The importance of organ geometry and boundary constraints for planning of medical interventions Med Eng Phys 31 195 206 18815068 10.1016/j.medengphy.2008.08.002 1:STN:280: DC%2BD1M7itlCnsw%3D%3D
-
(2009)
Med Eng Phys
, vol.31
, pp. 195-206
-
-
Misra, S.1
MacUra, K.J.2
Ramesh, K.T.3
-
27
-
-
33745291957
-
Control of soft tissue deformation during robotic needle insertion
-
DOI 10.1080/13645700600771645, PII P122715046163
-
N Abolhassani R Patel M Moallem 2006 Control of soft tissue deformation during robotic needle insertion Minim Invasive Ther Allied Technol 15 165 176 16785183 10.1080/13645700600771645 (Pubitemid 43931964)
-
(2006)
Minimally Invasive Therapy and Allied Technologies
, vol.15
, Issue.3
, pp. 165-176
-
-
Abolhassani, N.1
Patel, R.2
Moallem, M.3
-
28
-
-
33747026179
-
A new robotic needle insertion method to minimise attendant prostate motion
-
DOI 10.1016/j.radonc.2006.06.013, PII S0167814006002520
-
V Lagerburg MA Moerland VM van Vulpen, et al. 2006 A new robotic needle insertion method to minimise attendant prostate motion Radiother Oncol 80 73 77 16870290 10.1016/j.radonc.2006.06.013 (Pubitemid 44205310)
-
(2006)
Radiotherapy and Oncology
, vol.80
, Issue.1
, pp. 73-77
-
-
Lagerburg, V.1
Moerland, M.A.2
Van Vulpen, M.3
Lagendijk, J.J.W.4
-
29
-
-
33645521830
-
Development of a tapping device: A new needle insertion method for prostate brachytherapy
-
16467585 10.1088/0031-9155/51/4/009 1:STN:280:DC%2BD28%2FotFGquw%3D%3D
-
V Lagerburg MA Moerland MK Konings, et al. 2006 Development of a tapping device: a new needle insertion method for prostate brachytherapy Phys Med Biol 51 891 902 16467585 10.1088/0031-9155/51/4/009 1:STN:280: DC%2BD28%2FotFGquw%3D%3D
-
(2006)
Phys Med Biol
, vol.51
, pp. 891-902
-
-
Lagerburg, V.1
Moerland, M.A.2
Konings, M.K.3
-
30
-
-
34748913702
-
Observations on rotating needle insertions using a brachytherapy robot
-
DOI 10.1088/0031-9155/52/19/021, PII S0031915507515812, 021
-
MA Meltsner NJ Ferrier BR Thomadsen 2007 Observations on rotating needle insertions using a brachytherapy robot Phys Med Biol 52 6027 6037 17881817 10.1088/0031-9155/52/19/021 1:STN:280:DC%2BD2srmt1Kksw%3D%3D (Pubitemid 47485430)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.19
, pp. 6027-6037
-
-
Meltsner, M.A.1
Ferrier, N.J.2
Thomadsen, B.R.3
-
31
-
-
34250003745
-
Focal Cryosurgery: Encouraging Health Outcomes for Unifocal Prostate Cancer
-
DOI 10.1016/j.urology.2007.02.047, PII S0090429507002890
-
EH Lambert K Bolte P Masson, et al. 2007 Focal cryosurgery: encouraging health outcomes for unifocal prostate cancer Urology 69 1117 1120 17572198 10.1016/j.urology.2007.02.047 (Pubitemid 46891597)
-
(2007)
Urology
, vol.69
, Issue.6
, pp. 1117-1120
-
-
Lambert, E.H.1
Bolte, K.2
Masson, P.3
Katz, A.E.4
-
32
-
-
77951623497
-
Focal laser ablation for prostate cancer followed by radical prostatectomy: Validation of focal therapy and imaging accuracy
-
20346578 10.1016/j.eururo.2010.03.008
-
U Lindner N Lawrentschuk RA Weersink, et al. 2010 Focal laser ablation for prostate cancer followed by radical prostatectomy: validation of focal therapy and imaging accuracy Eur Urol 57 1111 1114 20346578 10.1016/j.eururo. 2010.03.008
-
(2010)
Eur Urol
, vol.57
, pp. 1111-1114
-
-
Lindner, U.1
Lawrentschuk, N.2
Weersink, R.A.3
-
33
-
-
34548068889
-
MR thermometry for monitoring tumor ablation
-
DOI 10.1007/s00330-007-0646-6
-
BD de Senneville C Mougenot B Quesson, et al. 2007 MR thermometry for monitoring tumor ablation Eur Radiol 17 2401 2410 17701184 10.1007/s00330-007- 0646-6 (Pubitemid 47288279)
-
(2007)
European Radiology
, vol.17
, Issue.9
, pp. 2401-2410
-
-
Senneville, B.D.1
Mougenot, C.2
Quesson, B.3
Dragonu, I.4
Grenier, N.5
Moonen, C.T.W.6
|