-
1
-
-
0014078493
-
Production of deep focal lesions by focused ultrasound current status
-
Lele PP (1967) Production of deep focal lesions by focused ultrasound current status. Ultrasonics 5:105-112
-
(1967)
Ultrasonics
, vol.5
, pp. 105-112
-
-
Lele, P.P.1
-
2
-
-
0033630061
-
Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough
-
Dodd GD, Soulen MC, Kane RA, Livraghi T, Lees WR, Yamashita Y, Gillams AR, Karahan OI, Rhim H (2000) Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough. Radiographics 20(1):9-27
-
(2000)
Radiographics
, vol.20
, Issue.1
, pp. 9-27
-
-
Dodd, G.D.1
Soulen, M.C.2
Kane, R.A.3
Livraghi, T.4
Lees, W.R.5
Yamashita, Y.6
Gillams, A.R.7
Karahan, O.I.8
Rhim, H.9
-
3
-
-
33746268104
-
Hepatocellular carcinoma
-
Marrero JA (2006) Hepatocellular carcinoma. Curr Opin Gastroenterol 22(3):248-253
-
(2006)
Curr Opin Gastroenterol
, vol.22
, Issue.3
, pp. 248-253
-
-
Marrero, J.A.1
-
4
-
-
33746253170
-
Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients
-
Memarsadeghi M, Schmook T, Remzi M, Weber M, Potscher G, Lammer J, Kettenbach J (2006) Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients. Eur J Radiol 59(2):183-189
-
(2006)
Eur J Radiol
, vol.59
, Issue.2
, pp. 183-189
-
-
Memarsadeghi, M.1
Schmook, T.2
Remzi, M.3
Weber, M.4
Potscher, G.5
Lammer, J.6
Kettenbach, J.7
-
5
-
-
34047236045
-
Experimental and clinical radiofrequency ablation: Proposal for standardized description of coagulation size and geometry
-
Mulier S, Ni Y, Frich L, Burdio F, Denys AL, De Wispelaere JF, Dupas B, Habib N, Hoey M, Jansen MC, Lacrosse M, Leveillee R, Miao Y, Mulier P, Mutter D, Ng KK, Santambrogio R, Stippel D, Tamaki K, van Gulik TM, Marchal G, Michel L (2007) Experimental and clinical radiofrequency ablation: Proposal for standardized description of coagulation size and geometry. Ann Surg Oncol
-
(2007)
Ann Surg Oncol
-
-
Mulier, S.1
Ni, Y.2
Frich, L.3
Burdio, F.4
Denys, A.L.5
De Wispelaere, J.F.6
Dupas, B.7
Habib, N.8
Hoey, M.9
Jansen, M.C.10
Lacrosse, M.11
Leveillee, R.12
Miao, Y.13
Mulier, P.14
Mutter, D.15
Ng, K.K.16
Santambrogio, R.17
Stippel, D.18
Tamaki, K.19
van Gulik, T.M.20
Marchal, G.21
Michel, L.22
more..
-
6
-
-
0037372845
-
MR imaging-guided focused ultrasound surgery of uterine leiomyomas: A feasibility study
-
Mar
-
Tempany CM, Stewart EA, McDannold N, Quade BJ, Jolesz FA, Hynynen K (2003) MR imaging-guided focused ultrasound surgery of uterine leiomyomas: A feasibility study. Radiology 226(3):897-905. Mar
-
(2003)
Radiology
, vol.226
, Issue.3
, pp. 897-905
-
-
Tempany, C.M.1
Stewart, E.A.2
McDannold, N.3
Quade, B.J.4
Jolesz, F.A.5
Hynynen, K.6
-
7
-
-
30344483219
-
Clinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids
-
Stewart EA, Rabinovici J, Tempany CMC, Inbar Y, Regan L, Gastout B, Hesley G, Kim HS, Hengst S, Gedroye WM (2006) Clinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids. Fertil Steril 85(1):22-29
-
(2006)
Fertil Steril
, vol.85
, Issue.1
, pp. 22-29
-
-
Stewart, E.A.1
Rabinovici, J.2
Tempany, C.M.C.3
Inbar, Y.4
Regan, L.5
Gastout, B.6
Hesley, G.7
Kim, H.S.8
Hengst, S.9
Gedroye, W.M.10
-
8
-
-
33745221857
-
Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
-
Furusawa H, Namba K, Thomsen S, Akiyama F, Bendet A, Tanaka C, Yasuda Y, Nakahara H (2006) Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness. J Am Coll Surg 203(1):54-63
-
(2006)
J Am Coll Surg
, vol.203
, Issue.1
, pp. 54-63
-
-
Furusawa, H.1
Namba, K.2
Thomsen, S.3
Akiyama, F.4
Bendet, A.5
Tanaka, C.6
Yasuda, Y.7
Nakahara, H.8
-
9
-
-
20844453598
-
The use of MR imaging guided focused ultrasound in breast cancer patients; A preliminary phase one study and review
-
Zippel DB, Papa MZ (2005) The use of MR imaging guided focused ultrasound in breast cancer patients; a preliminary phase one study and review. Breast Cancer 12:32-38
-
(2005)
Breast Cancer
, vol.12
, pp. 32-38
-
-
Zippel, D.B.1
Papa, M.Z.2
-
10
-
-
33645455996
-
Five years experience of transrectal high-intensity focused ultrasound using the Sonablate device in the treatment of localized prostate cancer
-
Uchida T, Ohkusa H, Yamashita H, Shoji S, Nagata Y, Hyodo T, Satoh T (2006) Five years experience of transrectal high-intensity focused ultrasound using the Sonablate device in the treatment of localized prostate cancer. Int J Urol 13(3):228-233
-
(2006)
Int J Urol
, vol.13
, Issue.3
, pp. 228-233
-
-
Uchida, T.1
Ohkusa, H.2
Yamashita, H.3
Shoji, S.4
Nagata, Y.5
Hyodo, T.6
Satoh, T.7
-
11
-
-
1642601566
-
High-intensity focused ultrasound for the treatment of liver tumours
-
Kennedy JE, Wu F, ter Haar GR, Gleeson FV, Phillips RR, Middleton MR, Cranston D (2004) High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics 42(1-9):931-935
-
(2004)
Ultrasonics
, vol.42
, Issue.1-9
, pp. 931-935
-
-
Kennedy, J.E.1
Wu, F.2
ter Haar, G.R.3
Gleeson, F.V.4
Phillips, R.R.5
Middleton, M.R.6
Cranston, D.7
-
12
-
-
33644931912
-
Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound
-
Hacker A, Michel MS, Marlinghaus E, Kohrmann KU, Alken P (2006) Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound. BJU Int 97(4):779-785
-
(2006)
BJU Int
, vol.97
, Issue.4
, pp. 779-785
-
-
Hacker, A.1
Michel, M.S.2
Marlinghaus, E.3
Kohrmann, K.U.4
Alken, P.5
-
13
-
-
32144433521
-
Non-invasive ablation of high intensity focused ultrasound for the treatment of patients with malignant bone tumours
-
Wu F, Wang ZB et al (2003) Non-invasive ablation of high intensity focused ultrasound for the treatment of patients with malignant bone tumours. J Bone Joint Surg (Br) 87-B(Issue Supp I):4
-
(2003)
J Bone Joint Surg (Br)
, vol.87 B
, Issue.SUPPL. I
, pp. 4
-
-
Wu, F.1
Wang, Z.B.2
-
14
-
-
0036743188
-
High-intensity focused ultrasound in patients with late-stage pancreatic carcinoma
-
Wang X, Sun J (2002) High-intensity focused ultrasound in patients with late-stage pancreatic carcinoma. Chin Med J (Engl) 115(9):1332-1335
-
(2002)
Chin Med J (Engl)
, vol.115
, Issue.9
, pp. 1332-1335
-
-
Wang, X.1
Sun, J.2
-
15
-
-
0042474524
-
Image-guided control of transgene expression based on local hyperthermia
-
Guilhon E, Quesson B, Moraud-Gaudry F, de Verneuil H, Canioni P, Salomir R, Voisin P, Moonen CTW (2003) Image-guided control of transgene expression based on local hyperthermia. J Molecular Imaging 2(1):11-17
-
(2003)
J Molecular Imaging
, vol.2
, Issue.1
, pp. 11-17
-
-
Guilhon, E.1
Quesson, B.2
Moraud-Gaudry, F.3
de Verneuil, H.4
Canioni, P.5
Salomir, R.6
Voisin, P.7
Moonen, C.T.W.8
-
16
-
-
0031912284
-
On the feasibility of MRI-guided focused ultrasound for local induction of gene expression
-
Madio DP, Van Gelderen P, DesPres D, Olson AW, de Zwart JA, Fawcett TW, Holbrook N, Mandel M, Moonen CTW (1998) On the feasibility of MRI-guided focused ultrasound for local induction of gene expression. J Magn Reson Imaging 8:101-104
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 101-104
-
-
Madio, D.P.1
Van Gelderen, P.2
DesPres, D.3
Olson, A.W.4
de Zwart, J.A.5
Fawcett, T.W.6
Holbrook, N.7
Mandel, M.8
Moonen, C.T.W.9
-
18
-
-
33745686043
-
Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI
-
Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24:152-159
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 152-159
-
-
Lepetit-Coiffe, M.1
Quesson, B.2
Seror, O.3
Dumont, E.4
Le Bail, B.5
Moonen, C.T.W.6
Trillaud, H.7
-
19
-
-
0020629894
-
Temperature distribution measurements in two-dimensional NMR imaging
-
Parker DL, Smith V, Sheldon P, Crooks LE, Fussell L (1983) Temperature distribution measurements in two-dimensional NMR imaging. Med Phys 10(3):321-325
-
(1983)
Med Phys
, vol.10
, Issue.3
, pp. 321-325
-
-
Parker, D.L.1
Smith, V.2
Sheldon, P.3
Crooks, L.E.4
Fussell, L.5
-
20
-
-
0029942580
-
Dynamic T1-weighted magnetic resonance imaging of interstitial laser photocoagulation in the liver: Observationson in vivo temperature sensitivity
-
Fried MP, Morrison PR, Hushek SG, Kernahan GA, Jolesz FA (1996) Dynamic T1-weighted magnetic resonance imaging of interstitial laser photocoagulation in the liver: Observations on in vivo temperature sensitivity. Lasers Surg Med 18(4):410-419
-
(1996)
Lasers Surg Med
, vol.18
, Issue.4
, pp. 410-419
-
-
Fried, M.P.1
Morrison, P.R.2
Hushek, S.G.3
Kernahan, G.A.4
Jolesz, F.A.5
-
21
-
-
0031933418
-
Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle
-
Graham SJ, Bronskill MJ, Henkelman RM (1998) Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle. Magn Reson Med 39(2):198-203
-
(1998)
Magn Reson Med
, vol.39
, Issue.2
, pp. 198-203
-
-
Graham, S.J.1
Bronskill, M.J.2
Henkelman, R.M.3
-
22
-
-
0024370936
-
Temperature mapping with MR imaging of molecular diffusion: Application to hyperthermia
-
Le Bihan D, Delannoy J, Levin RL (1989) Temperature mapping with MR imaging of molecular diffusion: Application to hyperthermia. Radiology 171(3):853-867
-
(1989)
Radiology
, vol.171
, Issue.3
, pp. 853-867
-
-
Le Bihan, D.1
Delannoy, J.2
Levin, R.L.3
-
23
-
-
0028854080
-
Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle
-
De Poorter J, De Wagter C, De Deene Y, Thomsen C, Stahlberg F, Achten E (1995) Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle. Magn Reson Med 33(1):74-81
-
(1995)
Magn Reson Med
, vol.33
, Issue.1
, pp. 74-81
-
-
De Poorter, J.1
De Wagter, C.2
De Deene, Y.3
Thomsen, C.4
Stahlberg, F.5
Achten, E.6
-
24
-
-
0028785052
-
A precise and fast temperature mapping using water proton chemical shift
-
Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K et al (1995) A precise and fast temperature mapping using water proton chemical shift. Magn Reson Med 34(6):814-823
-
(1995)
Magn Reson Med
, vol.34
, Issue.6
, pp. 814-823
-
-
Ishihara, Y.1
Calderon, A.2
Watanabe, H.3
Okamoto, K.4
Suzuki, Y.5
Kuroda, K.6
-
25
-
-
0033962907
-
Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue
-
Peters RD, Henkelman RM (2000) Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue. Magn Reson Med 43:62-71
-
(2000)
Magn Reson Med
, vol.43
, pp. 62-71
-
-
Peters, R.D.1
Henkelman, R.M.2
-
26
-
-
0031886917
-
Three-dimensional monitoring of small temperature changes for therapeutic hyperthermia using MR
-
Wlodarczyk W, Boroschewski R, Hentschel M, Wust P, Monich G, Felix R (1998) Three-dimensional monitoring of small temperature changes for therapeutic hyperthermia using MR. J Magn Reson Imaging 8(1):165-174
-
(1998)
J Magn Reson Imaging
, vol.8
, Issue.1
, pp. 165-174
-
-
Wlodarczyk, W.1
Boroschewski, R.2
Hentschel, M.3
Wust, P.4
Monich, G.5
Felix, R.6
-
27
-
-
0033818660
-
Magnetic resonance temperature imaging for guidance of thermotherapy
-
Quesson B, de Zwart JA, Moonen CTW (2000) Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 12(4):525-533
-
(2000)
J Magn Reson Imaging
, vol.12
, Issue.4
, pp. 525-533
-
-
Quesson, B.1
de Zwart, J.A.2
Moonen, C.T.W.3
-
29
-
-
0032769191
-
Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation
-
de Zwart JA, Vimeux FC, Delalande C, Canioni P, Moonene CT (1999) Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation. Magn Reson Med 42(1):53-59
-
(1999)
Magn Reson Med
, vol.42
, Issue.1
, pp. 53-59
-
-
de Zwart, J.A.1
Vimeux, F.C.2
Delalande, C.3
Canioni, P.4
Moonene, C.T.5
-
30
-
-
0031951478
-
MRI evaluation of thermal ablation of tumors with focused ultrasound
-
McDannold N, Hynynen K, Wolf D, Wolf G, Jolesz F (1998) MRI evaluation of thermal ablation of tumors with focused ultrasound. J Magn Reson Ig 8:91-100
-
(1998)
J Magn Reson Ig
, vol.8
, pp. 91-100
-
-
McDannold, N.1
Hynynen, K.2
Wolf, D.3
Wolf, G.4
Jolesz, F.5
-
31
-
-
0028339895
-
MR temperature mapping of focused ultrasound surgery
-
Cline HE, Hynynen K, Hardy CJ, Watkins RD, Schenck JF, Jolesz FA (1994) MR temperature mapping of focused ultrasound surgery. Magn Reson Med 31:628-636
-
(1994)
Magn Reson Med
, vol.31
, pp. 628-636
-
-
Cline, H.E.1
Hynynen, K.2
Hardy, C.J.3
Watkins, R.D.4
Schenck, J.F.5
Jolesz, F.A.6
-
32
-
-
33749171081
-
Palliative treatments for patients with inoperable gastroesophageal cancers
-
Popat S, Lopez J, Chan S, Waters J, Cominos M, Rutter D, Hill ME (2006) Palliative treatments for patients with inoperable gastroesophageal cancers. Int J Palliat Nurs 12(7):306-317
-
(2006)
Int J Palliat Nurs
, vol.12
, Issue.7
, pp. 306-317
-
-
Popat, S.1
Lopez, J.2
Chan, S.3
Waters, J.4
Cominos, M.5
Rutter, D.6
Hill, M.E.7
-
33
-
-
33645536583
-
Palliative endoscopic treatments for esophageal cancers
-
Dahan L, Ries P, Laugier R, Seitz JF (2006) Palliative endoscopic treatments for esophageal cancers. Gastroenterol Clin Biol 30(2):253-261
-
(2006)
Gastroenterol Clin Biol
, vol.30
, Issue.2
, pp. 253-261
-
-
Dahan, L.1
Ries, P.2
Laugier, R.3
Seitz, J.F.4
-
34
-
-
0035171704
-
MR monitoring of laser-induced lesions of the liver in vivo in a low-field open magnet: Temperature mapping and lesion size prediction
-
Germain D, Chevallier P, Laurent A, Savart M, Wassef M, Saint-Jalmes H (2001) MR monitoring of laser-induced lesions of the liver in vivo in a low-field open magnet: Temperature mapping and lesion size prediction. J Magn Reson Imaging 13(1):42-49
-
(2001)
J Magn Reson Imaging
, vol.13
, Issue.1
, pp. 42-49
-
-
Germain, D.1
Chevallier, P.2
Laurent, A.3
Savart, M.4
Wassef, M.5
Saint-Jalmes, H.6
-
35
-
-
8644285079
-
MR-guided laser-induced thermotherapy (LITT) of liver tumours: Experimental and clinical data
-
Vogl TJ, Straub R, Zangos S, Mack MG, Eichler K (2004) MR-guided laser-induced thermotherapy (LITT) of liver tumours: Experimental and clinical data. Int J Hyperthermia 20(7):713-724
-
(2004)
Int J Hyperthermia
, vol.20
, Issue.7
, pp. 713-724
-
-
Vogl, T.J.1
Straub, R.2
Zangos, S.3
Mack, M.G.4
Eichler, K.5
-
36
-
-
4043063500
-
Laser-induced thermotherapy of lung metastases and primary lung tumors
-
Vogl TJ, Fieguth HG, Eichler K, Straub R, Lehnert T, Zangos S, Mack M (2004) Laser-induced thermotherapy of lung metastases and primary lung tumors. Radiologe 44(7):693-699
-
(2004)
Radiologe
, vol.44
, Issue.7
, pp. 693-699
-
-
Vogl, T.J.1
Fieguth, H.G.2
Eichler, K.3
Straub, R.4
Lehnert, T.5
Zangos, S.6
Mack, M.7
-
37
-
-
17044414086
-
Interventional radiology in Carney triad
-
Vogl TJ, Lehnert T, Wetter A, Mack MG, Wurster MG (2005) Interventional radiology in Carney triad. Eur Radiol 15(4):833-837
-
(2005)
Eur Radiol
, vol.15
, Issue.4
, pp. 833-837
-
-
Vogl, T.J.1
Lehnert, T.2
Wetter, A.3
Mack, M.G.4
Wurster, M.G.5
-
38
-
-
21944442052
-
Hereditary haemorrhagic telangiectasia: State of the art
-
Fiorella ML, Ross DA, White RI, Sabba C, Fiorella R (2004) Hereditary haemorrhagic telangiectasia: State of the art. Acta Otorhinolaryngol Ital 24(6):330-336
-
(2004)
Acta Otorhinolaryngol Ital
, vol.24
, Issue.6
, pp. 330-336
-
-
Fiorella, M.L.1
Ross, D.A.2
White, R.I.3
Sabba, C.4
Fiorella, R.5
-
39
-
-
14944385341
-
Laser-induced Interstitial thermotherapy (LITT) in hepatic metastases of various sizes in an animal model
-
Maataoui A, Qian J, Mack MG, Straub R, Oppermann E, Khan MF, Knappe V, Vogl TJ (2005) Laser-induced Interstitial thermotherapy (LITT) in hepatic metastases of various sizes in an animal model. Rofo 177(3):405-410
-
(2005)
Rofo
, vol.177
, Issue.3
, pp. 405-410
-
-
Maataoui, A.1
Qian, J.2
Mack, M.G.3
Straub, R.4
Oppermann, E.5
Khan, M.F.6
Knappe, V.7
Vogl, T.J.8
-
40
-
-
0033918197
-
Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck
-
Eyrich GK, Bruder E, Hilfiker P, Dubno B, Quick HH, Patak MA, Gratz KW, Sailer HF (2000) Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck. Lasers Surg Med 26(5):467-476
-
(2000)
Lasers Surg Med
, vol.26
, Issue.5
, pp. 467-476
-
-
Eyrich, G.K.1
Bruder, E.2
Hilfiker, P.3
Dubno, B.4
Quick, H.H.5
Patak, M.A.6
Gratz, K.W.7
Sailer, H.F.8
-
41
-
-
33644558226
-
Laser interstitial thermo therapy (LITT) for brain tumors
-
Atsumi H, Matsumae M (2005) Laser interstitial thermo therapy (LITT) for brain tumors. Nippon Rinsho 63(Suppl 9):495-498
-
(2005)
Nippon Rinsho
, vol.63
, Issue.SUPPL. 9
, pp. 495-498
-
-
Atsumi, H.1
Matsumae, M.2
-
42
-
-
0033661583
-
Magnetic resonance thermometry for predicting thermal damage: An application of interstitial laser coagulation in an in vivo canine prostate model
-
Peters RD, Chan E, Trachtenberg J, Jothy S, Kapusta L, Kucharczyk W et al (2000) Magnetic resonance thermometry for predicting thermal damage: an application of interstitial laser coagulation in an in vivo canine prostate model. Magn Reson Med 44(6):873-883
-
(2000)
Magn Reson Med
, vol.44
, Issue.6
, pp. 873-883
-
-
Peters, R.D.1
Chan, E.2
Trachtenberg, J.3
Jothy, S.4
Kapusta, L.5
Kucharczyk, W.6
-
43
-
-
0242290981
-
Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion
-
Vigen KK, Daniel BL, Pauly JM, Butts K (2003) Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med 50(5):1003-1010
-
(2003)
Magn Reson Med
, vol.50
, Issue.5
, pp. 1003-1010
-
-
Vigen, K.K.1
Daniel, B.L.2
Pauly, J.M.3
Butts, K.4
-
45
-
-
0025269759
-
Thermal lesions induced by 480 KHz localized current field in guinea pig and pig liver
-
Rossi S, Fornari F, Pathies C, Buscarini L (1990) Thermal lesions induced by 480 KHz localized current field in guinea pig and pig liver. Tumori 76:54-57
-
(1990)
Tumori
, vol.76
, pp. 54-57
-
-
Rossi, S.1
Fornari, F.2
Pathies, C.3
Buscarini, L.4
-
46
-
-
3242783960
-
Standardization of terms and reporting criteria for imageguided tumor ablation
-
author reply 627
-
Nour SG (2004) Standardization of terms and reporting criteria for imageguided tumor ablation. Radiology 232:626-627; author reply 627
-
(2004)
Radiology
, vol.232
, pp. 626-627
-
-
Nour, S.G.1
-
47
-
-
2942724313
-
Large liver tumors: Protocol for radiofrequency ablation and its clinical application in 110 patients-mathematic model, overlapping mode, and electrode placement process
-
Chen MH, Yang W, Yan K et al (2004) Large liver tumors: Protocol for radiofrequency ablation and its clinical application in 110 patients-mathematic model, overlapping mode, and electrode placement process. Radiology 232:260-271
-
(2004)
Radiology
, vol.232
, pp. 260-271
-
-
Chen, M.H.1
Yang, W.2
Yan, K.3
-
48
-
-
3042600909
-
Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound
-
Solbiati L, Ierace T, Tonolini M, Cova L (2004) Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound. Eur Journ Radiol 51(Suppl):S19-S23
-
(2004)
Eur Journ Radiol
, vol.51
, Issue.SUPPL.
-
-
Solbiati, L.1
Ierace, T.2
Tonolini, M.3
Cova, L.4
-
50
-
-
28444468480
-
Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system
-
Gellermann J, Wlodarczyk W, Feussner A, Fahling H, Nadobny J, Hildebrandt B, Felix R, Wust P (2005) Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system. Int J Hyperthermia 21(6):497-513
-
(2005)
Int J Hyperthermia
, vol.21
, Issue.6
, pp. 497-513
-
-
Gellermann, J.1
Wlodarczyk, W.2
Feussner, A.3
Fahling, H.4
Nadobny, J.5
Hildebrandt, B.6
Felix, R.7
Wust, P.8
-
51
-
-
33745686043
-
Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI
-
Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24(1):152-159
-
(2006)
J Magn Reson Imaging
, vol.24
, Issue.1
, pp. 152-159
-
-
Lepetit-Coiffe, M.1
Quesson, B.2
Seror, O.3
Dumont, E.4
Le Bail, B.5
Moonen, C.T.W.6
Trillaud, H.7
-
52
-
-
0035489422
-
Essential techniques for successful radio-frequency thermal ablation of malignant hepatic tumors
-
3rd (spec no): discussion S36-S19
-
Rhim H, Goldberg SN, Dodd GD 3rd et al (2001) Essential techniques for successful radio-frequency thermal ablation of malignant hepatic tumors. Radiographics 21(spec no):S17-S35; discussion S36-S19
-
(2001)
Radiographics
, vol.21
-
-
Rhim, H.1
Goldberg, S.N.2
Dodd, G.D.3
-
53
-
-
1842557963
-
Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study
-
Aube C, Schmidt D, Brieger J et al (2004) Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study. J Vasc Interv Radiol 15:385-392
-
(2004)
J Vasc Interv Radiol
, vol.15
, pp. 385-392
-
-
Aube, C.1
Schmidt, D.2
Brieger, J.3
-
54
-
-
33747083181
-
An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: Phantom and animal studies
-
Demura K, Morikawa S, Murakami K, Sato K, Shiomi H, Naka S, Kurumi Y, Inubushi T, Tani T (2006) An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: Phantom and animal studies. J Surg Res 135(1):179-186
-
(2006)
J Surg Res
, vol.135
, Issue.1
, pp. 179-186
-
-
Demura, K.1
Morikawa, S.2
Murakami, K.3
Sato, K.4
Shiomi, H.5
Naka, S.6
Kurumi, Y.7
Inubushi, T.8
Tani, T.9
-
55
-
-
33644874363
-
Alternate biplanar MR navigation for microwave ablation of liver tumors
-
Sato K, Morikawa S, Inubushi T, Kurumi Y, Naka S, Haque HA, Demura K, Tani T (2005) Alternate biplanar MR navigation for microwave ablation of liver tumors. Magn Reson Med Sci 4(2):89-94
-
(2005)
Magn Reson Med Sci
, vol.4
, Issue.2
, pp. 89-94
-
-
Sato, K.1
Morikawa, S.2
Inubushi, T.3
Kurumi, Y.4
Naka, S.5
Haque, H.A.6
Demura, K.7
Tani, T.8
-
56
-
-
0000871653
-
Histological and cerebral lesions produced by focused ultrasound
-
Lynn JG, Putman TJ (1944) Histological and cerebral lesions produced by focused ultrasound. Am J Pathol 20:637-649
-
(1944)
Am J Pathol
, vol.20
, pp. 637-649
-
-
Lynn, J.G.1
Putman, T.J.2
-
57
-
-
84939112974
-
MR-guided focused ultrasound surgery
-
Cline HE, Schenck JF, Hynynen K, Watkins RD, Souza SP, Jolesz FA (1992) MR-guided focused ultrasound surgery. J Comput Assist Tomogr 16(6):956-965
-
(1992)
J Comput Assist Tomogr
, vol.16
, Issue.6
, pp. 956-965
-
-
Cline, H.E.1
Schenck, J.F.2
Hynynen, K.3
Watkins, R.D.4
Souza, S.P.5
Jolesz, F.A.6
-
58
-
-
0041411671
-
High power transcranial beam steering for ultrasonic brain therapy
-
Pernot M, Aubry JF, Tanter M, Thomas JL, Fink M (2003) High power transcranial beam steering for ultrasonic brain therapy. Phys Med Biol 48(16):2577-2589
-
(2003)
Phys Med Biol
, vol.48
, Issue.16
, pp. 2577-2589
-
-
Pernot, M.1
Aubry, J.F.2
Tanter, M.3
Thomas, J.L.4
Fink, M.5
-
59
-
-
33746242230
-
Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-a primate study
-
Hynynen K, McDannold N, Clement G, Jolesz FA, Zadicario E, Killiany R, Moore T, Rosen D (2006) Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-a primate study. Eur J Radiol 59(2):149-156
-
(2006)
Eur J Radiol
, vol.59
, Issue.2
, pp. 149-156
-
-
Hynynen, K.1
McDannold, N.2
Clement, G.3
Jolesz, F.A.4
Zadicario, E.5
Killiany, R.6
Moore, T.7
Rosen, D.8
-
60
-
-
33845226808
-
Magnetic resonance imaging-guided, high-intensity focused ultrasound for brain tumor therapy
-
Ram Z, Cohen ZR, Harnof S, Tal S, Faibel M, Nass D, Maier SE, Hadani M, Mardor Y (2006) Magnetic resonance imaging-guided, high-intensity focused ultrasound for brain tumor therapy. Neurosurgery 59(5):949-955
-
(2006)
Neurosurgery
, vol.59
, Issue.5
, pp. 949-955
-
-
Ram, Z.1
Cohen, Z.R.2
Harnof, S.3
Tal, S.4
Faibel, M.5
Nass, D.6
Maier, S.E.7
Hadani, M.8
Mardor, Y.9
-
61
-
-
33846815451
-
Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound
-
Denis de Senneville B, Mougenot C, Moonen CTW (2007) Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound. Magn Reson Med 57(2):319-330
-
(2007)
Magn Reson Med
, vol.57
, Issue.2
, pp. 319-330
-
-
Denis de Senneville, B.1
Mougenot, C.2
Moonen, C.T.W.3
-
63
-
-
0028839871
-
The rician distribution of noisy MRI data
-
Gudbjartsson H, Patz S (1995) The rician distribution of noisy MRI data. Magn Reson Med 34:910-914
-
(1995)
Magn Reson Med
, vol.34
, pp. 910-914
-
-
Gudbjartsson, H.1
Patz, S.2
-
64
-
-
1542346904
-
Maximum likelihood estimation of signal amplitude and noise variance from MR data
-
Sijbers J, den Dekker AJ (2004) Maximum likelihood estimation of signal amplitude and noise variance from MR data. Magn Reson Med 51:589-594
-
(2004)
Magn Reson Med
, vol.51
, pp. 589-594
-
-
Sijbers, J.1
den Dekker, A.J.2
-
65
-
-
33744607266
-
The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in phantom
-
De Poorter J, De Wagter C, De Deene Y, Thomson C, Stahlberg F, Achten E (1994) The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in phantom. J Magn Reson 103:234-241
-
(1994)
J Magn Reson
, vol.103
, pp. 234-241
-
-
De Poorter, J.1
De Wagter, C.2
De Deene, Y.3
Thomson, C.4
Stahlberg, F.5
Achten, E.6
-
66
-
-
0029738544
-
An evaluation of the effects of susceptibility changes on the water chemical shift method of temperature measurement in human peripheral muscle
-
Young IR, Hajnal JV, Roberts IG, Ling JX, Hill-Cottingham RJ, Oatridge A et al (1996) An evaluation of the effects of susceptibility changes on the water chemical shift method of temperature measurement in human peripheral muscle. Magn Reson Med 36(3):366-374
-
(1996)
Magn Reson Med
, vol.36
, Issue.3
, pp. 366-374
-
-
Young, I.R.1
Hajnal, J.V.2
Roberts, I.G.3
Ling, J.X.4
Hill-Cottingham, R.J.5
Oatridge, A.6
-
67
-
-
7544242319
-
Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point
-
Mougenot C, Salomir R, Palussière J, Grenier N, Moonen CTW (2004) Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point. Magn Reson Med 52:1005-1015
-
(2004)
Magn Reson Med
, vol.52
, pp. 1005-1015
-
-
Mougenot, C.1
Salomir, R.2
Palussière, J.3
Grenier, N.4
Moonen, C.T.W.5
-
68
-
-
0141940275
-
High intensity focused ultrasound: Surgery of the future?
-
Kennedy JE, ter Haar GR, Cranston D (2003) High intensity focused ultrasound: Surgery of the future? Br J Radiol 76(909):590-599
-
(2003)
Br J Radiol
, vol.76
, Issue.909
, pp. 590-599
-
-
Kennedy, J.E.1
ter Haar, G.R.2
Cranston, D.3
-
69
-
-
2942755646
-
Fast frequency mapping with balanced SSFP: Theory and application to proton-resonance frequency shift thermometry
-
Scheffler K (2004) Fast frequency mapping with balanced SSFP: Theory and application to proton-resonance frequency shift thermometry. Magn Reson Med 51(6):1205-1211
-
(2004)
Magn Reson Med
, vol.51
, Issue.6
, pp. 1205-1211
-
-
Scheffler, K.1
-
70
-
-
0033630061
-
Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough
-
Dodd GD, Soulen MC, Kane RA, Livraghi T, Lees WR, Yamashita Y, Gillams AR, Karahan OI, Rhim H (2000) Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough. Radiographics 20(1):9-27
-
(2000)
Radiographics
, vol.20
, Issue.1
, pp. 9-27
-
-
Dodd, G.D.1
Soulen, M.C.2
Kane, R.A.3
Livraghi, T.4
Lees, W.R.5
Yamashita, Y.6
Gillams, A.R.7
Karahan, O.I.8
Rhim, H.9
|