Volumn 59, Issue 1, 2012, Pages 45-49

In vivo imaging and spectroscopy of dynamic metabolism using simultaneous 13C and 1H MRI

Author keywords

Gadolinium; intracellular; magnetic resonance (MR); metabolism; pyruvate

Indexed keywords

CONTRAST AGENT; HYPERPOLARIZED; IN-VIVO; IN-VIVO IMAGING; INTRACELLULAR; INTRACELLULAR COMPARTMENTS; INTRACELLULAR SPACES; KINETIC MODELING; KINETIC MODELS; METABOLIC RATES; NOVEL TECHNIQUES; PYRUVATES; SEQUENTIAL INJECTION; SIMULTANEOUS ACQUISITION;

EID: 84555190713     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2011.2161988     Document Type: Article
Times cited : (26)

References (17)
  • 6
    • 70849085768 scopus 로고    scopus 로고
    • Kinetics of hyperpo-larized 13C1-pyruvate transport and metabolism in living human breast cancer cells
    • T. Harris, G. Eliyahu, L. Frydman, and H. Degani, "Kinetics of hyperpo-larized 13C1-pyruvate transport and metabolism in living human breast cancer cells," Proc. Nat. Acad. Sci., vol. 106, no. 43, pp. 18131-18136, 2009.
    • (2009) Proc. Nat. Acad. Sci. , vol.106 , Issue.43 , pp. 18131-18136
    • Harris, T.1    Eliyahu, G.2    Frydman, L.3    Degani, H.4
  • 11
    • 0344117718 scopus 로고    scopus 로고
    • 1 measurements
    • DOI 10.1002/(SICI)1522-2594(199910)42:4<746::AID-MRM17>3.0.CO;2-U
    • G. O. Cron, G. Santyr, and F. Kelcz, "Accurate and rapid quantitative dynamic contrast-enhanced breast MR imaging using spoiled gradient-recalled echoes and bookend T1 measurements," Magn. Reson. Med., vol. 42, no. 4, pp. 746-753, 1999. (Pubitemid 29468305)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.4 , pp. 746-753
    • Cron, G.O.1    Santyr, G.2    Kelcz, F.3
  • 12
    • 68949210569 scopus 로고    scopus 로고
    • Modulating the relaxivity of hyperpolarized substrates with gadolinium contrast agents
    • C. Gabellieri, M. O. Leach, and T. R. Eykyn, "Modulating the relaxivity of hyperpolarized substrates with gadolinium contrast agents," Contrast Media Molecular Imag., vol. 4, no. 3, pp. 143-147, 2009.
    • (2009) Contrast Media Molecular Imag. , vol.4 , Issue.3 , pp. 143-147
    • Gabellieri, C.1    Leach, M.O.2    Eykyn, T.R.3
  • 13
    • 84555179542 scopus 로고    scopus 로고
    • Dual-tuned 1H/13C orthogonal double solenoid volume coil for simultaneous acquisition in small animals in vivo
    • L. C. Bell, E. T. Peterson, J. W. Gordon, S. B. Fain, and K. N. Kurpad, "Dual-tuned 1H/13C orthogonal double solenoid volume coil for simultaneous acquisition in small animals in vivo," in Proc Int. Soc. Magn. Reson. Med., 2010, p. 7112.
    • Proc Int. Soc. Magn. Reson. Med. , vol.2010 , pp. 7112
    • Bell, L.C.1    Peterson, E.T.2    Gordon, J.W.3    Fain, S.B.4    Kurpad, K.N.5
  • 14
    • 0017851927 scopus 로고
    • On the use of windows for harmonic analysis with the discrete Fourier transform
    • F. J. Harris, "On the use of windows for harmonic analysis with the discrete Fourier transform," Proc. IEEE, vol. 66, no. 1, pp. 51-83, 1978. (Pubitemid 8338069)
    • (1978) Proceedings of the IEEE , vol.66 , Issue.1 , pp. 51-83
    • Harris, F.J.1
  • 15
    • 57249097670 scopus 로고    scopus 로고
    • An efficient algorithm for automatic phase correction of NMR spectra based on entropy minimization
    • L. Chen, Z. Weng, L. Goh, and M. Garland, "An efficient algorithm for automatic phase correction of NMR spectra based on entropy minimization," J. Magn. Reson., vol. 158, no. 1-2, pp. 164-168, 2002.
    • (2002) J. Magn. Reson. , vol.158 , Issue.1-2 , pp. 164-168
    • Chen, L.1    Weng, Z.2    Goh, L.3    Garland, M.4
  • 17
    • 7544225845 scopus 로고    scopus 로고
    • Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations
    • DOI 10.1002/mrm.20243
    • C. Yang, G. S. Karczmar, M. Medved, and W. M. Stadler, "Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations," Magn. Reson. Med., vol. 52, no. 5, pp. 1110-1117, 2004. (Pubitemid 39453285)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.5 , pp. 1110-1117
    • Yang, C.1    Karczmar, G.S.2    Medved, M.3    Stadler, W.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.