메뉴 건너뛰기




Volumn 52, Issue 5, 2004, Pages 1110-1117

Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations

Author keywords

Arterial input function; Contrast agent; Dynamic MRI; Gd DTPA; Pharmacokinetic model

Indexed keywords

HISTOLOGY; KINETIC PARAMETERS; MAGNETIC RESONANCE IMAGING; TISSUE; TRACERS;

EID: 7544225845     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20243     Document Type: Article
Times cited : (96)

References (27)
  • 1
    • 0022135246 scopus 로고
    • Regional cerebral blood flow: Estimation by means of nonmetabolized diffusible tracers - An overview
    • Kety SS. Regional cerebral blood flow: estimation by means of nonmetabolized diffusible tracers - an overview. Semin Nucl Med 1985;15:324-328.
    • (1985) Semin Nucl Med , vol.15 , pp. 324-328
    • Kety, S.S.1
  • 2
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. I. Fundamental concepts
    • Tofts PS, Kermode AG. Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. I. Fundamental concepts. Magn Reson Med 1991;17:357-367.
    • (1991) Magn Reson Med , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 4
    • 0035428054 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MRI studies in oncology with an emphasis on quantification, validation and human studies
    • Padhani AR, Husband JE. Dynamic contrast-enhanced MRI studies in oncology with an emphasis on quantification, validation and human studies. Clin Radiol 2001;56:607-620.
    • (2001) Clin Radiol , vol.56 , pp. 607-620
    • Padhani, A.R.1    Husband, J.E.2
  • 5
    • 0008610371 scopus 로고    scopus 로고
    • Pitfalls in the measurement of tissue permeability over short-scales using a low temporal resolution blood input function
    • New York
    • Parker GJ, Tanner SF, Leach MO. Pitfalls in the measurement of tissue permeability over short-scales using a low temporal resolution blood input function. In: Proceedings of the 4th Annual Meeting of ISMRM, New York, 1996. p 1582.
    • (1996) Proceedings of the 4th Annual Meeting of ISMRM , pp. 1582
    • Parker, G.J.1    Tanner, S.F.2    Leach, M.O.3
  • 6
    • 0032845185 scopus 로고    scopus 로고
    • Multicompartment analysis of gadolinium chelate kinetics: Blood-tissue exchange in mammary tumors as monitored by dynamic MR imaging
    • Port RE, Knopp MV, Hoffmann U, Milker-Zabel S, Brix G. Multicompartment analysis of gadolinium chelate kinetics: blood-tissue exchange in mammary tumors as monitored by dynamic MR imaging. J Magn Reson Imaging 1999;10:233-241.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 233-241
    • Port, R.E.1    Knopp, M.V.2    Hoffmann, U.3    Milker-Zabel, S.4    Brix, G.5
  • 7
    • 0029761382 scopus 로고    scopus 로고
    • Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging
    • Fritz-Hansen T, Rostrup E, Larsson HB, Sondergaard L, Ring P, Henriksen O. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging. Magn Reson Med 1996;36:225-231.
    • (1996) Magn Reson Med , vol.36 , pp. 225-231
    • Fritz-Hansen, T.1    Rostrup, E.2    Larsson, H.B.3    Sondergaard, L.4    Ring, P.5    Henriksen, O.6
  • 8
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 9
    • 0028917193 scopus 로고
    • Pharmacokinetic mapping of the breast: A new method for dynamic MR mammography
    • Hoffmann U, Brix G, Knopp MV, Hess T, Lorenz WJ. Pharmacokinetic mapping of the breast: a new method for dynamic MR mammography. Magn Reson Med 1995;33:506-514.
    • (1995) Magn Reson Med , vol.33 , pp. 506-514
    • Hoffmann, U.1    Brix, G.2    Knopp, M.V.3    Hess, T.4    Lorenz, W.J.5
  • 10
    • 0031797063 scopus 로고    scopus 로고
    • An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: II. Experimental validation
    • St Lawrence KS, Lee TY. An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: II. Experimental validation. J Cereb Blood Flow Metab 1998;18:1378-1385.
    • (1998) J Cereb Blood Flow Metab , vol.18 , pp. 1378-1385
    • St Lawrence, K.S.1    Lee, T.Y.2
  • 11
    • 0031758817 scopus 로고    scopus 로고
    • A new method for imaging perfusion and contrast extraction fraction: Input functions derived from reference tissues
    • Kovar DA, Lewis M, Karczmar GS. A new method for imaging perfusion and contrast extraction fraction: input functions derived from reference tissues. J Magn Reson Imaging 1998;8:1126-1134.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1126-1134
    • Kovar, D.A.1    Lewis, M.2    Karczmar, G.S.3
  • 12
    • 0031766478 scopus 로고    scopus 로고
    • Capillary diffusion capacity and tissue distribution of pancreatic procolipase in rat
    • Rippe C, Rippe B, Erlanson-Albertsson C. Capillary diffusion capacity and tissue distribution of pancreatic procolipase in rat. Am J Physiol 1998;275(5 Pt 1):G1179-G1184.
    • (1998) Am J Physiol , vol.275 , Issue.5 PART 1
    • Rippe, C.1    Rippe, B.2    Erlanson-Albertsson, C.3
  • 15
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 16
    • 0008335295 scopus 로고
    • Two comments on the estimation of blood flow and central volume from dye-dilution curves
    • Evans RL. Two comments on the estimation of blood flow and central volume from dye-dilution curves. J Appl Physiol 1959;14:457.
    • (1959) J Appl Physiol , vol.14 , pp. 457
    • Evans, R.L.1
  • 18
    • 0001747857 scopus 로고
    • An empirical formula for indicator-dilution curves as obtained in human beings
    • Stow RW, Hetzel PS. An empirical formula for indicator-dilution curves as obtained in human beings. J Appl Physiol 1954;7:161-167.
    • (1954) J Appl Physiol , vol.7 , pp. 161-167
    • Stow, R.W.1    Hetzel, P.S.2
  • 19
    • 0013893605 scopus 로고
    • Applications of the lagged normal density curve as a model for arterial dilution curves
    • Bassingthwaighte JB, Ackerman FH, Wood EH. Applications of the lagged normal density curve as a model for arterial dilution curves. Circ Res 1966;18:398-415.
    • (1966) Circ Res , vol.18 , pp. 398-415
    • Bassingthwaighte, J.B.1    Ackerman, F.H.2    Wood, E.H.3
  • 20
    • 0017651654 scopus 로고
    • Physiology and theory of tracer washout techniques for the estimation of myocardial blood flow: Flow estimation from tracer washout
    • Bassingthwaighte JB. Physiology and theory of tracer washout techniques for the estimation of myocardial blood flow: flow estimation from tracer washout. Prog Cardiovasc Dis 1977;20:165-189.
    • (1977) Prog Cardiovasc Dis , vol.20 , pp. 165-189
    • Bassingthwaighte, J.B.1
  • 21
    • 0029894317 scopus 로고    scopus 로고
    • Approximation of arterial input curve data in MRI estimation of cerebral blood-tumor-barrier leakage: Comparison between Gd-DTPA and 99mTc-DTPA input curves
    • Andersen C, Taagehoj JF, Muhler A, Rehling M. Approximation of arterial input curve data in MRI estimation of cerebral blood-tumor-barrier leakage: comparison between Gd-DTPA and 99mTc-DTPA input curves. Magn Reson Imaging 1996;14:235-241.
    • (1996) Magn Reson Imaging , vol.14 , pp. 235-241
    • Andersen, C.1    Taagehoj, J.F.2    Muhler, A.3    Rehling, M.4
  • 22
    • 0342298515 scopus 로고    scopus 로고
    • Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors
    • Li KL, Zhu XP, Waterton J, Jackson A. Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors. J Magn Reson Imaging 2000;12:347-357.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 347-357
    • Li, K.L.1    Zhu, X.P.2    Waterton, J.3    Jackson, A.4
  • 23
    • 0036199430 scopus 로고    scopus 로고
    • Reproducibility of quantitative dynamic MRI of normal human tissues
    • Padhani AR, Hayes C, Landau S, Leach MO. Reproducibility of quantitative dynamic MRI of normal human tissues. NMR Biomed 2002;15:143-153.
    • (2002) NMR Biomed , vol.15 , pp. 143-153
    • Padhani, A.R.1    Hayes, C.2    Landau, S.3    Leach, M.O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.