메뉴 건너뛰기




Volumn 46, Issue 12, 2011, Pages 2097-2099

Backscatter factor measurements for kilovoltage X-ray beams using thermoluminescent dosimeters (TLDs)

Author keywords

Backscatter factors; Kilovoltage x ray beams; Monte Carlo; Thermoluminescent dosimeters

Indexed keywords

ABSORBED DOSE; BACKSCATTER FACTORS; EGSNRC MONTE CARLO; EXPERIMENTAL MEASUREMENTS; LIF:MG , TI; LIF:MG ,CU ,P; MONTE CARLO; MONTE CARLO CALCULATION; MONTE CARLO SIMULATION; THERMOLUMINESCENT DOSIMETERS; TLD-100; TLD-100H; X RAY BEAM; X-RAY FLUENCE;

EID: 82355173121     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2011.08.019     Document Type: Conference Paper
Times cited : (12)

References (18)
  • 2
    • 58149269275 scopus 로고    scopus 로고
    • Study of the formalism used to determine the absorbed dose for low-energy x-ray beams
    • U. Chica, M. Anguiano, and A.M. Lallena Study of the formalism used to determine the absorbed dose for low-energy x-ray beams Physics in Medicine and Biology 53 23 2008 6963 6977
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.23 , pp. 6963-6977
    • Chica, U.1    Anguiano, M.2    Lallena, A.M.3
  • 3
    • 0031943186 scopus 로고    scopus 로고
    • Lithium borate TLD for determining the backscatter factors for low- energy x rays: Comparison with chamber-based and Monte Carlo derived values
    • D. Coudin, and G. Marinello Lithium borate TLD for determining the backscatter factors for low- energy x rays: comparison with chamber-based and Monte Carlo derived values Medical Physics 25 3 1998 347 353
    • (1998) Medical Physics , vol.25 , Issue.3 , pp. 347-353
    • Coudin, D.1    Marinello, G.2
  • 4
    • 0021131849 scopus 로고
    • Backscatter factors for x-rays generated at voltages between 10 and 100 kV
    • B. Grosswendt Backscatter factors for x-rays generated at voltages between 10 and 100 kV Physics in Medicine and Biology 29 5 1984 579 591
    • (1984) Physics in Medicine and Biology , vol.29 , Issue.5 , pp. 579-591
    • Grosswendt, B.1
  • 5
    • 0025140589 scopus 로고
    • Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size
    • B. Grosswendt Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size Physics in Medicine and Biology 35 9 1990 1233 1245
    • (1990) Physics in Medicine and Biology , vol.35 , Issue.9 , pp. 1233-1245
    • Grosswendt, B.1
  • 6
    • 0025178893 scopus 로고
    • Measurement of backscatter factors for low energy radiotherapy (0.1-2.0 mm Al HVL) using thermoluminescence dosimetry
    • R.M. Harrison Measurement of backscatter factors for low energy radiotherapy (0.1-2.0 mm Al HVL) using thermoluminescence dosimetry Physics in Medicine and Biology 35 9 1990 1247
    • (1990) Physics in Medicine and Biology , vol.35 , Issue.9 , pp. 1247
    • Harrison, R.M.1
  • 8
    • 27144551316 scopus 로고    scopus 로고
    • A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
    • R. Hill, L. Holloway, and C. Baldock A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams Physics in Medicine and Biology 50 21 2005 N331 N344
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.21
    • Hill, R.1    Holloway, L.2    Baldock, C.3
  • 9
    • 77955229090 scopus 로고    scopus 로고
    • The Bland-Altman analysis: Does it have a role in assessing radiation dosimeter performance relative to an established standard?
    • R.F. Hill, P.S. Tofts, and C. Baldock The Bland-Altman analysis: Does it have a role in assessing radiation dosimeter performance relative to an established standard? Radiation Measurements 45 7 2010 810 815
    • (2010) Radiation Measurements , vol.45 , Issue.7 , pp. 810-815
    • Hill, R.F.1    Tofts, P.S.2    Baldock, C.3
  • 10
    • 76149125204 scopus 로고    scopus 로고
    • An investigation of backscatter factors for kilovoltage x-rays: A comparison between Monte Carlo simulations and Gafchromic EBT film measurements
    • J. Kim, R. Hill, E. Claridge MacKonis, and Z. Kuncic An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements Physics in Medicine and Biology 55 3 2010 783 797
    • (2010) Physics in Medicine and Biology , vol.55 , Issue.3 , pp. 783-797
    • Kim, J.1    Hill, R.2    Claridge MacKonis, E.3    Kuncic, Z.4
  • 11
    • 0024355954 scopus 로고
    • Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140 kV
    • S.C. Klevenhagen Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140 kV Physics in Medicine and Biology 34 12 1989 1871 1882
    • (1989) Physics in Medicine and Biology , vol.34 , Issue.12 , pp. 1871-1882
    • Klevenhagen, S.C.1
  • 12
    • 0029846001 scopus 로고    scopus 로고
    • The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential)
    • S.C. Klevenhagen, R.J. Aukett, R.M. Harrison, C. Moretti, A.E. Nahum, and K.E. Rosser The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential) Physics in Medicine and Biology 41 12 1996 2605 2625
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.12 , pp. 2605-2625
    • Klevenhagen, S.C.1    Aukett, R.J.2    Harrison, R.M.3    Moretti, C.4    Nahum, A.E.5    Rosser, K.E.6
  • 13
    • 0034973266 scopus 로고    scopus 로고
    • AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
    • C.M. Ma, C.W. Coffey, L.A. DeWerd, C. Liu, R. Nath, and S.M. Seltzer AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology Medical Physics 28 6 2001 868 893
    • (2001) Medical Physics , vol.28 , Issue.6 , pp. 868-893
    • Ma, C.M.1    Coffey, C.W.2    Dewerd, L.A.3    Liu, C.4    Nath, R.5    Seltzer, S.M.6
  • 14
    • 0344267664 scopus 로고    scopus 로고
    • Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams
    • C.M. Ma, and J.P. Seuntjens Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams Physics in Medicine and Biology 44 1 1999 131 143
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.1 , pp. 131-143
    • Ma, C.M.1    Seuntjens, J.P.2
  • 15
    • 0031855026 scopus 로고    scopus 로고
    • A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams
    • P.N. Mobit, A.E. Nahum, and P.M. Lest A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams Physics in Medicine and Biology 43 8 1998 2015 2032
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.8 , pp. 2015-2032
    • Mobit, P.N.1    Nahum, A.E.2    Lest, P.M.3
  • 16
    • 82355176727 scopus 로고    scopus 로고
    • Response of TL dosimeters outside the edge of a 6 MV Linac beam and its implications on patient dosimetry. in
    • V. Nelson Response of TL dosimeters outside the edge of a 6 MV Linac beam and its implications on patient dosimetry. In IFMBE Proceedings 2007 2079 2082
    • (2007) IFMBE Proceedings , pp. 2079-2082
    • Nelson, V.1
  • 17
    • 51849167775 scopus 로고    scopus 로고
    • Kilovoltage x-ray dosimetry-an experimental comparison between different dosimetry protocols
    • M.A.P. Rosenschold, P. Nilsson, and T. Knoos Kilovoltage x-ray dosimetry-an experimental comparison between different dosimetry protocols Physics in Medicine and Biology 53 16 2008 4431 4442
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.16 , pp. 4431-4442
    • Rosenschold, M.A.P.1    Nilsson, P.2    Knoos, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.