Volumn 14, Issue 1, 2007, Pages 2079-2082

Response of TL dosimeters outside the field edge of a 6 MV linac beam and its implication on patient dosimetry

Author keywords

Dosemeters; Linear accelerator; Thermoluminescence

Indexed keywords

BIOMEDICAL ENGINEERING; DOSIMETERS; DOSIMETRY; LINEAR ACCELERATORS; LITHIUM COMPOUNDS; RISK PERCEPTION; SENSITIVITY ANALYSIS; TUMORS; X RAY DETECTORS;

EID: 82355176727     PISSN: 16800737     EISSN: 14339277     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-36841-0_524     Document Type: Conference Paper
Times cited : (4)

References (6)
  • 1
    • 4644348621 scopus 로고    scopus 로고
    • Near surface photon energy spectra out a 6 MV field edge
    • Edwards CR and Mountford PJ (2004) Near surface photon energy spectra out a 6 MV field edge. Phys Med Biol. 49:N293–N301.
    • (2004) Phys Med Biol , vol.49 , pp. N293-N301
    • Edwards, C.R.1    Mountford, P.J.2
  • 2
    • 4644367203 scopus 로고    scopus 로고
    • Variation in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: Implications for clinical dosimetry
    • Duggan, L, Hood C, Warren-Forward H, et al. (2004) Variation in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry. Phys Med Biol. 49:3831–3845.
    • (2004) Phys Med Biol , vol.49 , pp. 3831-3845
    • Duggan, L.1    Hood, C.2    Warren-Forward, H.3
  • 3
    • 0031441616 scopus 로고    scopus 로고
    • The response of a MOSFET, p-type semiconductor and LiF TLD to quasimonoenergetic x-rays
    • Edwards CR, Green S, Palethorpe JE et al (1997) The response of a MOSFET, p-type semiconductor and LiF TLD to quasimonoenergetic x-rays. Phys. Med. Biol. 42:2383-2391.
    • (1997) Phys. Med. Biol , vol.42 , pp. 2383-2391
    • Edwards, C.R.1    Green, S.2    Palethorpe, J.E.3
  • 4
    • 0031855026 scopus 로고    scopus 로고
    • A Monte Carlo study of the quality dependence factors for common TLD materials in photon and electron beams
    • Mobit PN, Nahum AE, Mayles P (1998) A Monte Carlo study of the quality dependence factors for common TLD materials in photon and electron beams. Phys. Med. Biol. 43:2015-2032.
    • (1998) Phys. Med. Biol , vol.43 , pp. 2015-2032
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 5
    • 0031773177 scopus 로고    scopus 로고
    • Dose response of various radiation detectors synchrotron radiation
    • Kron T, Duggan L, Smith T, et al (1998) Dose response of various radiation detectors synchrotron radiation. Phys. Med. Biol. 43:3235-3259.
    • (1998) Phys. Med. Biol , vol.43 , pp. 3235-3259
    • Kron, T.1    Duggan, L.2    Smith, T.3
  • 6
    • 0027257649 scopus 로고
    • Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosemeters
    • Olko P, Bilski P, Ryba E et al (1993) Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosemeters. Radiat. Prot. Dosim. 52:31-35.
    • (1993) Radiat. Prot. Dosim , vol.52 , pp. 31-35
    • Olko, P.1    Bilski, P.2    Ryba, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.