메뉴 건너뛰기




Volumn 30, Issue 4, 2007, Pages 269-273

Radiochromic film for verification of superficial x-ray backscatter factors

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; EXTRAPOLATION; RADIOTHERAPY; THERMOLUMINESCENCE; THIN FILMS;

EID: 38649124380     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178436     Document Type: Article
Times cited : (23)

References (16)
  • 1
    • 0029846001 scopus 로고    scopus 로고
    • The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology
    • IPEMB
    • IPEMB, The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology. Phys Med Biol. 41, 2605-25, 1996.
    • (1996) Phys Med Biol , vol.41 , pp. 2605-2625
  • 2
    • 20044379949 scopus 로고    scopus 로고
    • Aukett, R. J., Burns, J. E., Greener, A. G., Harrison, R. M., Moretti, C., Nahum, A. E. and Rosser, K. E.; IPEM Working Party. 2005 Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL). Phys Med Biol.50, 2739-48, 2005.
    • Aukett, R. J., Burns, J. E., Greener, A. G., Harrison, R. M., Moretti, C., Nahum, A. E. and Rosser, K. E.; IPEM Working Party. 2005 Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL). Phys Med Biol.50, 2739-48, 2005.
  • 3
    • 0019948998 scopus 로고
    • The build up of backscatter in the energy range 1mm to 8mm Al HVT
    • Klevenhagen, S., The build up of backscatter in the energy range 1mm to 8mm Al HVT Phys Med Biol 27, 1035-1043, 1982.
    • (1982) Phys Med Biol , vol.27 , pp. 1035-1043
    • Klevenhagen, S.1
  • 4
    • 0024355954 scopus 로고
    • Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140kv
    • Klevenhagen, S. C., Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140kv. Phys Med Biol 34, 1871-1882, 1989.
    • (1989) Phys Med Biol , vol.34 , pp. 1871-1882
    • Klevenhagen, S.C.1
  • 5
    • 0031943186 scopus 로고    scopus 로고
    • Lithium borate TLD for determining the backscatter factors for low-energy x rays: Comparison with chamber-based and Monte Carlo derived values
    • Coudin, D. and Marinello, G., Lithium borate TLD for determining the backscatter factors for low-energy x rays: Comparison with chamber-based and Monte Carlo derived values, Med Phys. 25, 347-53, 1998.
    • (1998) Med Phys , vol.25 , pp. 347-353
    • Coudin, D.1    Marinello, G.2
  • 6
    • 0031812771 scopus 로고    scopus 로고
    • Superficial and orthovoltage x-ray beam dosimetry
    • Podgorsak, E. B., Gosselin, M. and Evans, M. D., Superficial and orthovoltage x-ray beam dosimetry, Med Phys. 25, 1206-11, 1998.
    • (1998) Med Phys , vol.25 , pp. 1206-1211
    • Podgorsak, E.B.1    Gosselin, M.2    Evans, M.D.3
  • 7
    • 0025140589 scopus 로고
    • Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size
    • Grosswendt, B., Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size, Phys Med Biol 35, 1233-1245, 1990.
    • (1990) Phys Med Biol , vol.35 , pp. 1233-1245
    • Grosswendt, B.1
  • 8
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp - 10 MVp X-ray range
    • Butson, M. J., Cheung, T. and Yu, K. N., Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp - 10 MVp X-ray range, Applied Radiation and Isotopes, 64, 60-62, 2006.
    • (2006) Applied Radiation and Isotopes , vol.64 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, K.N.3
  • 9
    • 33745242546 scopus 로고    scopus 로고
    • Skin entrance radiation dose in an interventional radiology procedure
    • Chu, R. Y., Thomas, G. and Maqbool, F., Skin entrance radiation dose in an interventional radiology procedure. Health Phys. 91(1):41-6, 2006.
    • (2006) Health Phys , vol.91 , Issue.1 , pp. 41-46
    • Chu, R.Y.1    Thomas, G.2    Maqbool, F.3
  • 12
    • 85036966711 scopus 로고    scopus 로고
    • International specialty Products web page
    • International specialty Products web page: http://www.ispcorp.com/ products/dosimetry/index.html
  • 13
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations
    • Constantinou, C., Attix, F. H. and Paliwal, B. R., A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations Med. Phys. 9 436-441, 1982.
    • (1982) Med. Phys , vol.9 , pp. 436-441
    • Constantinou, C.1    Attix, F.H.2    Paliwal, B.R.3
  • 14
    • 27144551316 scopus 로고    scopus 로고
    • A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
    • Hill, R., Holloway, L. and Baldock, C., A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams, Phys. Med. Biol. 50 N331-N344, 2005.
    • (2005) Phys. Med. Biol , vol.50
    • Hill, R.1    Holloway, L.2    Baldock, C.3
  • 16
    • 0030334814 scopus 로고    scopus 로고
    • Smith, C. W., Orthovoltage X-ray beams (0.5 mm-4.0 mm Cu HVL). BJR Suppl. 25 24-38, 1996.
    • Smith, C. W., Orthovoltage X-ray beams (0.5 mm-4.0 mm Cu HVL). BJR Suppl. 25 24-38, 1996.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.