Volumn 53, Issue 16, 2008, Pages 4431-4442

Kilovoltage x-ray dosimetry - An experimental comparison between different dosimetry protocols

Author keywords

[No Author keywords available]

Indexed keywords

BACKSCATTERING; COPPER; DOSIMETERS; DOSIMETRY; FLUID DYNAMICS; FLUID MECHANICS; MANAGEMENT SCIENCE; MATHEMATICAL MODELS; MONTE CARLO METHODS; NUCLEAR ENGINEERING;

EID: 51849167775     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/16/014     Document Type: Article
Times cited : (23)

References (24)
  • 1
    • 33746511273 scopus 로고    scopus 로고
    • Absorbed dose determination in external beam radiotherapy: An international Code of Practice for dosimetry based on standards of absorbed dose to water
    • Andreo P, Burns D T, Hohlfeld K, Huq M S, Kanai T, Laitano F, Smyth V G and Vynckier S 2000 Absorbed dose determination in external beam radiotherapy: an international Code of Practice for dosimetry based on standards of absorbed dose to water IAEA TRS-398 (Vienna: IAEA)
    • (2000) IAEA TRS-398
    • Andreo, P.1    Burns, D.T.2    Hohlfeld, K.3    Huq, M.S.4    Kanai, T.5    Laitano, F.6    Smyth, V.G.7    Vynckier, S.8
  • 3
    • 20044379949 scopus 로고    scopus 로고
    • Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL)
    • Aukett R J, Burns J E, Greener A G, Harrison R M, Moretti C, Nahum A E and Rosser K E (IPEM Working Party) 2005 Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL) Phys. Med. Biol. 50 2739-48
    • (2005) Phys. Med. Biol. , vol.50 , Issue.12 , pp. 2739-2748
    • Aukett, R.J.1    Burns, J.E.2    Greener, A.G.3    Harrison, R.M.4    Moretti, C.5    Nahum, A.E.6    Rosser, K.E.7
  • 4
    • 0011074428 scopus 로고    scopus 로고
    • Central axis depth dose data for use in radiotherapy
    • BJR 1996 Central axis depth dose data for use in radiotherapy Br. J. Radiol. (Suppl 25)
    • (1996) Br. J. Radiol. , Issue.SUPPL. 25
  • 5
    • 0033679098 scopus 로고    scopus 로고
    • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy
    • Björk P, Knöös T and Nilsson P 2000 Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy Med. Phys. 27 2580-8
    • (2000) Med. Phys. , vol.27 , Issue.11 , pp. 2580-2588
    • Björk, P.1    Knöös, T.2    Nilsson, P.3
  • 6
    • 0031858318 scopus 로고    scopus 로고
    • A simple test device for electrometers
    • Blad B, Wendel P and Nilsson P 1998 A simple test device for electrometers Phys. Med. Biol. 43 2385-91
    • (1998) Phys. Med. Biol. , vol.43 , Issue.8 , pp. 2385-2391
    • Blad, B.1    Wendel, P.2    Nilsson, P.3
  • 9
    • 0034911960 scopus 로고    scopus 로고
    • Performance assessment of the Gulmay D3300 kilovoltage x-ray therapy unit
    • Evans P A, Moloney A J and Mountford P J 2001 Performance assessment of the Gulmay D3300 kilovoltage x-ray therapy unit Br. J. Radiol. 74 537-47
    • (2001) Br. J. Radiol. , vol.74 , Issue.882 , pp. 537-547
    • Evans, P.A.1    Moloney, A.J.2    Mountford, P.J.3
  • 11
    • 0021131849 scopus 로고
    • Backscatter factors for x-rays generated at voltages between 10 and 100 kV
    • Grosswendt B 1984 Backscatter factors for x-rays generated at voltages between 10 and 100 kV Phys. Med. Biol. 29 579-91
    • (1984) Phys. Med. Biol. , vol.29 , Issue.5 , pp. 579-591
    • Grosswendt, B.1
  • 12
    • 0025140589 scopus 로고
    • Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size
    • Grosswendt B 1990 Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size Phys. Med. Biol. 35 1233-45
    • (1990) Phys. Med. Biol. , vol.35 , Issue.9 , pp. 1233-1245
    • Grosswendt, B.1
  • 13
    • 0027402558 scopus 로고
    • Dependence of the photon backscatter factor for water on irradiation field size and source-to-phantom distances between 1.5 and 10 cm
    • Grosswendt B 1993 Dependence of the photon backscatter factor for water on irradiation field size and source-to-phantom distances between 1.5 and 10 cm Phys. Med. Biol. 38 305-10
    • (1993) Phys. Med. Biol. , vol.38 , Issue.2 , pp. 305-310
    • Grosswendt, B.1
  • 15
    • 0029846001 scopus 로고    scopus 로고
    • The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential)
    • Klevenhagen S C, Aukett R J, Harrison R M, Moretti C, Nahum A E and Rosser K E 1996 The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential) Phys. Med. Biol. 41 2605-25
    • (1996) Phys. Med. Biol. , vol.41 , Issue.12 , pp. 2605-2625
    • Klevenhagen, S.C.1    Aukett, R.J.2    Harrison, R.M.3    Moretti, C.4    Nahum, A.E.5    Rosser, K.E.6
  • 16
    • 34548668945 scopus 로고    scopus 로고
    • Modelling of an orthovoltage x-ray therapy unit with the EGSnrc Monte Carlo package
    • Knöös T, Munck af Rosenschöld P M and Wieslander E 2007 Modelling of an orthovoltage x-ray therapy unit with the EGSnrc Monte Carlo package J. Phys. Conf. Ser. 74 021009
    • (2007) J. Phys. Conf. Ser. , vol.74 , pp. 021009
    • Knöös, T.1    Munck Af Rosenschöld, P.M.2    Wieslander, E.3
  • 17
    • 0031442330 scopus 로고    scopus 로고
    • Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams
    • Li X A, Ma C-M and Salhani D 1997 Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams Phys. Med. Biol. 42 2561-8
    • (1997) Phys. Med. Biol. , vol.42 , Issue.12 , pp. 2561-2568
    • Li, X.A.1    Ma, C.-M.2    Salhani, D.3
  • 18
    • 0034973266 scopus 로고    scopus 로고
    • American Association of Physicists in Medicine. AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
    • Ma C-M, Coffey C W, DeWerd L A, Liu C, Nath R, Seltzer S M and Seuntjens J P 2001 American Association of Physicists in Medicine. AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology Med. Phys. J. 28 868-93
    • (2001) Med. Phys. J. , vol.28 , Issue.6 , pp. 868-893
    • Ma, C.-M.1    Coffey, C.W.2    Dewerd, L.A.3    Liu, C.4    Nath, R.5    Seltzer, S.M.6    Seuntjens, J.P.7
  • 19
    • 0032415881 scopus 로고    scopus 로고
    • Study of dosimetry consistency for kilovoltage x-ray beams
    • Ma C-M, Li X A and Seuntjens J P 1998 Study of dosimetry consistency for kilovoltage x-ray beams Med. Phys. 25 2376-84
    • (1998) Med. Phys. , vol.25 , Issue.12 , pp. 2376-2384
    • Ma, C.-M.1    Li, X.A.2    Seuntjens, J.P.3
  • 20
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy?
    • Mijnheer B J, Battermann J J and Wambersie A 1987 What degree of accuracy is required and can be achieved in photon and neutron therapy? Radiother. Oncol. 8 237-52
    • (1987) Radiother. Oncol. , vol.8 , Issue.1 , pp. 49-252
    • Mijnheer, B.J.1    Battermann, J.J.2    Wambersie, A.3
  • 21
    • 0034120830 scopus 로고    scopus 로고
    • Determination of absorbed dose to water in reference conditions for radiotherapy kilovoltage x-rays between 10 and 300 kV: A comparison of the data in the IAEA, IPEMB, DIN and NCS dosimetry protocols
    • Peixoto J G and Andreo P 2000 Determination of absorbed dose to water in reference conditions for radiotherapy kilovoltage x-rays between 10 and 300 kV: a comparison of the data in the IAEA, IPEMB, DIN and NCS dosimetry protocols Phys. Med. Biol. 45 563-75
    • (2000) Phys. Med. Biol. , vol.45 , Issue.3 , pp. 563-575
    • Peixoto, J.G.1    Andreo, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.