메뉴 건너뛰기




Volumn 5, Issue 5, 2011, Pages 439-448

CMOS amperometric instrumentation and packaging for biosensor array applications

Author keywords

Biosensor array; biosensor packaging; CMOS amperometry; CMOS potentiostat

Indexed keywords

AMPEROMETRIC; AMPEROMETRY; BIOSENSOR ARRAYS; CLEANING PROCESS; CMOS INSTRUMENTATION; COMMERCIAL INSTRUMENTS; CONSTANT POTENTIAL; ELECTROCHEMICAL MEASUREMENTS; GOLD ELECTRODES; LINEAR RESOLUTIONS; MIXED SIGNAL INTEGRATED CIRCUITS; ON-CHIP ELECTRODES; POTASSIUM FERRICYANIDE; POTENTIOSTATS; PROGRAMMABLE CHIPS; PULSE VOLTAMMETRY; READ-OUT CIRCUIT; SCAN RANGE; SCAN RATES; STIMULUS RATES; TEST ENVIRONMENT;

EID: 80155165313     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2011.2171339     Document Type: Conference Paper
Times cited : (67)

References (36)
  • 1
    • 33749521210 scopus 로고    scopus 로고
    • On-chip electrochemical analysis system using nanoelectrodes and bioelectronic CMOS chip
    • May
    • X. Zhu and C. H. Ahn, "On-chip electrochemical analysis system using nanoelectrodes and bioelectronic CMOS chip," IEEE Sensors J., vol. 6, no. 6, pp. 1280-1287, May 2006.
    • (2006) IEEE Sensors J. , vol.6 , Issue.6 , pp. 1280-1287
    • Zhu, X.1    Ahn, C.H.2
  • 2
    • 0034430663 scopus 로고    scopus 로고
    • Analysis of heavymetal ions using mercury microelectrodes and a solid-state reference electrode on a Si wafer
    • Dec.
    • K. S. Yun, H. J. Kim, S. Joo, J. Kwak, and E. Yoon, "Analysis of heavymetal ions using mercury microelectrodes and a solid-state reference electrode on a Si wafer," Jpn. J. Appl. Phys. 1, vol. 39, no. 39, pp. 7159-7163, Dec. 2000.
    • (2000) Jpn. J. Appl. Phys. 1 , vol.39 , Issue.39 , pp. 7159-7163
    • Yun, K.S.1    Kim, H.J.2    Joo, S.3    Kwak, J.4    Yoon, E.5
  • 3
    • 10444230343 scopus 로고    scopus 로고
    • Afully electronic DNA sensor with 128 positions and in-pixel A/D conversion
    • Dec.
    • M. S. Schienle et al., "Afully electronic DNA sensor with 128 positions and in-pixel A/D conversion," IEEE J. Solid-State Circuits, vol. 39, no. 39, pp. 2438-2445, Dec. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.39 , pp. 2438-2445
    • Schienle, M.S.1
  • 4
    • 9144251670 scopus 로고    scopus 로고
    • A 128 × 128 CMOS biosensor array for extracellular recording of neural activity
    • B. Eversmann et al., "A 128 × 128 CMOS biosensor array for extracellular recording of neural activity," IEEE J. Solid-State Circuits, vol. 38, no. 38, pp. 2306-2317, 2003.
    • (2003) IEEE J. Solid-State Circuits , vol.38 , Issue.38 , pp. 2306-2317
    • Eversmann, B.1
  • 5
    • 52249087107 scopus 로고    scopus 로고
    • A real-time multi-channel monitoring system for stem cell culture process
    • Jun.
    • X. Yue et al., "A real-time multi-channel monitoring system for stem cell culture process," IEEE Trans. Biomed. Circuits Syst., vol. 2, no. 2, pp. 66-77, Jun. 2008.
    • (2008) IEEE Trans. Biomed. Circuits Syst. , vol.2 , Issue.2 , pp. 66-77
    • Yue, X.1
  • 6
    • 57849118481 scopus 로고    scopus 로고
    • Biosensor systems in standrard CMOS processes fact or fiction?
    • B. Jang and A. Hassibi, "Biosensor systems in standrard CMOS processes fact or fiction?," in Proc. IEEE Symp. Industrial Electronics, 2008, pp. 2045-2050.
    • (2008) Proc. IEEE Symp. Industrial Electronics , pp. 2045-2050
    • Jang, B.1    Hassibi, A.2
  • 8
    • 70349268229 scopus 로고    scopus 로고
    • A frequency shift CMOS magnetic biosensor array with single-bead sensitivity and no external maget
    • Feb.
    • H. Wang, Y. Chen, A. Hassibi, A. Scherer, and A. Hajimiri, "A frequency shift CMOS magnetic biosensor array with single-bead sensitivity and no external maget," in Proc. IEEE Int. Solid-State Circuits Conf., Feb. 2009, pp. 438-439.
    • (2009) Proc. IEEE Int. Solid-State Circuits Conf. , pp. 438-439
    • Wang, H.1    Chen, Y.2    Hassibi, A.3    Scherer, A.4    Hajimiri, A.5
  • 9
    • 33847330225 scopus 로고    scopus 로고
    • Electrochemical array microsystem with integrated potentiostat
    • Irvine, CA, Oct.
    • J. Zhang, Y. Huang, N. Trombly, C. Yang, and A. Mason, "Electrochemical array microsystem with integrated potentiostat," in Proc. IEEE Int. Conf. Sensors, Irvine, CA, Oct. 2005, pp. 385-388.
    • (2005) Proc. IEEE Int. Conf. Sensors , pp. 385-388
    • Zhang, J.1    Huang, Y.2    Trombly, N.3    Yang, C.4    Mason, A.5
  • 10
    • 77749327015 scopus 로고    scopus 로고
    • Amperometric electrochemical microsystem for a miniaturized protein biosensor array
    • Jun.
    • C. Yang, Y. Huang, B. L. Hassler, R. M. Worden, and A. J. Mason, "Amperometric electrochemical microsystem for a miniaturized protein biosensor array," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 3, pp. 160-168, Jun. 2009.
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.3 , pp. 160-168
    • Yang, C.1    Huang, Y.2    Hassler, B.L.3    Worden, R.M.4    Mason, A.J.5
  • 11
    • 70349459619 scopus 로고    scopus 로고
    • Fully integrated 7-order frequency range quadrature sinusoid signal generator
    • Oct.
    • C. Yang and A. Mason, "Fully integrated 7-order frequency range quadrature sinusoid signal generator," IEEE Trans. Instrum. Meas., vol. 58, no. 58, pp. 3481-3489, Oct. 2009.
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.58 , pp. 3481-3489
    • Yang, C.1    Mason, A.2
  • 12
    • 70350608305 scopus 로고    scopus 로고
    • Compact low power impedance-to-digital converter for sensor array microsystems
    • Oct.
    • C. Yang, S. R. Jadhav, M. R.Worden, and A. J. Mason, "Compact low power impedance-to-digital converter for sensor array microsystems," IEEE J. Solid-State Circuits, vol. 44, no. 44, pp. 2844-2855, Oct. 2009.
    • (2009) IEEE J. Solid-State Circuits , vol.44 , Issue.44 , pp. 2844-2855
    • Yang, C.1    Jadhav, S.R.2    Worden, M.R.3    Mason, A.J.4
  • 15
    • 13144277621 scopus 로고    scopus 로고
    • Encapsulation of ISFET sensor chips
    • W. Oelßner et al., "Encapsulation of ISFET sensor chips," Sens. Actuators B, Chem., vol. 105, no. 105, pp. 104-117, 2005.
    • (2005) Sens. Actuators B, Chem. , vol.105 , Issue.105 , pp. 104-117
    • Oelßner, W.1
  • 16
    • 33847335094 scopus 로고    scopus 로고
    • Novel direct-write CMOS-bsed laboratory-on-chip design, assembly and experimental results
    • Feb.
    • E. Ghafar-Zadeh, M. Sawan, and D. Therriault, "Novel direct-write CMOS-bsed laboratory-on-chip design, assembly and experimental results," Sens. Actuators A, Phys., vol. 134, no. 134, pp. 27-36, Feb. 2007.
    • (2007) Sens. Actuators A, Phys. , vol.134 , Issue.134 , pp. 27-36
    • Ghafar-Zadeh, E.1    Sawan, M.2    Therriault, D.3
  • 17
    • 76849101071 scopus 로고    scopus 로고
    • Switch-matrix-based high-density microelectrode array in CMOS technology
    • U. Frey et al., "Switch-matrix-based high-density microelectrode array in CMOS technology," IEEE J. Solid-State Circuits, vol. 45, no. 45, pp. 467-482, 2010.
    • (2010) IEEE J. Solid-State Circuits , vol.45 , Issue.45 , pp. 467-482
    • Frey, U.1
  • 18
    • 0025505831 scopus 로고
    • Encapsulation of chemically sensitive field-effect transistors with photocurable epoxy resins
    • C. Dumschat et al., "Encapsulation of chemically sensitive field-effect transistors with photocurable epoxy resins," Sens. Actuators B, Chem., vol. 2, no. 2, pp. 271-276, 1990.
    • (1990) Sens. Actuators B, Chem. , vol.2 , Issue.2 , pp. 271-276
    • Dumschat, C.1
  • 19
    • 34247855843 scopus 로고    scopus 로고
    • Design, fabrication, and testing of a hybrid CMOS/PDMS microsystem for cel lculture andincubation
    • Mar.
    • J. M. B. Christen and A. G. Andreou, "Design, fabrication, and testing of a hybrid CMOS/PDMS microsystem for cel lculture andincubation," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 1, pp. 3-18, Mar. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst. , vol.1 , Issue.1 , pp. 3-18
    • Christen, J.M.B.1    Andreou, A.G.2
  • 21
    • 21644486576 scopus 로고    scopus 로고
    • Novel integrated electrochemical nano-biochip for toxicity detection in water
    • R. Popovtzer et al., "Novel integrated electrochemical nano-biochip for toxicity detection in water," Nano Lett., vol. 5, no. 5, pp. 1023-1027, 2005.
    • (2005) Nano Lett. , vol.5 , Issue.5 , pp. 1023-1027
    • Popovtzer, R.1
  • 23
    • 65849245590 scopus 로고    scopus 로고
    • CMOS microelectrode array for electrochemical lab-on-a-cihp applications
    • Jun.
    • S. Hwang et al., "CMOS microelectrode array for electrochemical lab-on-a-cihp applications," IEEE J. Sensors, vol. 9, no. 9, pp. 609-615, Jun. 2009.
    • (2009) IEEE J. Sensors , vol.9 , Issue.9 , pp. 609-615
    • Hwang, S.1
  • 24
    • 48849089317 scopus 로고    scopus 로고
    • Active CMOS sensor array for electrochemical biomolecular detection
    • Aug.
    • P. M. Levine, P. Gong, R. Levicky, and K. L. Shepard, "Active CMOS sensor array for electrochemical biomolecular detection," IEEE J. Solid-State Circuits, vol. 43, no. 43, pp. 1859-1871, Aug. 2008.
    • (2008) IEEE J. Solid-State Circuits , vol.43 , Issue.43 , pp. 1859-1871
    • Levine, P.M.1    Gong, P.2    Levicky, R.3    Shepard, K.L.4
  • 25
    • 33845641002 scopus 로고    scopus 로고
    • A programmable 0.18-uμm CMOS electrochemical sensor microarray for biomolecular detection
    • Dec.
    • A. Hassibi and T. H. Lee, "A programmable 0.18-uμm CMOS electrochemical sensor microarray for biomolecular detection," IEEE J. Sensors, vol. 6, no. 6, pp. 1380-1388, Dec. 2006.
    • (2006) IEEE J. Sensors , vol.6 , Issue.6 , pp. 1380-1388
    • Hassibi, A.1    Lee, T.H.2
  • 26
    • 78649733463 scopus 로고    scopus 로고
    • Adigital CMOS-based 24 × 16 sensor array platform for fully automatic electrochemical DNA detection
    • P. Kruppa et al., "Adigital CMOS-based 24 × 16 sensor array platform for fully automatic electrochemical DNA detection," Biosen. Bioelectron., vol. 26, no. 26, pp. 1414-1419, 2010.
    • (2010) Biosen. Bioelectron. , vol.26 , Issue.26 , pp. 1414-1419
    • Kruppa, P.1
  • 27
    • 77749317040 scopus 로고    scopus 로고
    • A redox-enzyme-based electrochemical biosensor with a CMOS integrated bipotentiastat
    • Beijing, China, Nov.
    • Y. Huang and A. J. Mason, "A redox-enzyme-based electrochemical biosensor with a CMOS integrated bipotentiastat," in Proc. IEEE Biomedical Circuits Systems Conf., Beijing, China, Nov. 2009, pp. 29-32.
    • (2009) Proc. IEEE Biomedical Circuits Systems Conf. , pp. 29-32
    • Huang, Y.1    Mason, A.J.2
  • 28
    • 41549137931 scopus 로고    scopus 로고
    • Electrochemical biosensors-sensor principles and architectures
    • D. Grieshaber, R. MacKenzie, J. Voros, and E. Reimhult, "Electrochemical biosensors-sensor principles and architectures," Sens. Actuators B, Chem., vol. 8, no. 8, pp. 1400-1458, 2008.
    • (2008) Sens. Actuators B, Chem. , vol.8 , Issue.8 , pp. 1400-1458
    • Grieshaber, D.1    MacKenzie, R.2    Voros, J.3    Reimhult, E.4
  • 29
    • 4444313518 scopus 로고    scopus 로고
    • Carbon nanotube-chitosan system for electrochemical sensing basd on dehydrogenase enzymes
    • M. Zhang, A. Smith, and W. Gorski, "Carbon nanotube-chitosan system for electrochemical sensing basd on dehydrogenase enzymes," Anal. Chem., vol. 76, no. 76, pp. 5045-5050, 2004.
    • (2004) Anal. Chem. , vol.76 , Issue.76 , pp. 5045-5050
    • Zhang, M.1    Smith, A.2    Gorski, W.3
  • 30
    • 43049173742 scopus 로고    scopus 로고
    • Fabrication of highly insulating tethered bilayer lipid membrane using yeast cell membrane fractions for measuring ion channel activity
    • S. R. Jadhav, D. Sui, M. R. Garavito, and M. R. Worden, "Fabrication of highly insulating tethered bilayer lipid membrane using yeast cell membrane fractions for measuring ion channel activity," J. Colloid Interface Sci., vol. 322, no. 322, pp. 465-472, 2008.
    • (2008) J. Colloid Interface Sci. , vol.322 , Issue.322 , pp. 465-472
    • Jadhav, S.R.1    Sui, D.2    Garavito, M.R.3    Worden, M.R.4
  • 31
    • 0035954484 scopus 로고    scopus 로고
    • Tethered mono- and bilayer lipid membranes on Au and Hg
    • P. Krysinski et al., "Tethered mono- and bilayer lipid membranes on Au and Hg," Langmuir, vol. 17, no. 17, pp. 3852-3857, 2001.
    • (2001) Langmuir , vol.17 , Issue.17 , pp. 3852-3857
    • Krysinski, P.1
  • 32
    • 80155176348 scopus 로고    scopus 로고
    • Texas Instruments, DDC 118: Octal current Input, 20-bit Analog-to- Digital Converter, 2009
    • Texas Instruments, DDC 118: Octal current Input, 20-bit Analog-to- Digital Converter, 2009.
  • 33
    • 29044444845 scopus 로고    scopus 로고
    • A CMOSintegrated microinstrument for trace detection of heavy metals
    • Dec.
    • S. M. Martin, F. H. Gebara, B. J. Larivee, and R. B. Brown, "A CMOSintegrated microinstrument for trace detection of heavy metals," IEEE J. Solid-State Circuits, vol. 40, no. 40, pp. 2777-2786, Dec. 2005.
    • (2005) IEEE J. Solid-State Circuits , vol.40 , Issue.40 , pp. 2777-2786
    • Martin, S.M.1    Gebara, F.H.2    Larivee, B.J.3    Brown, R.B.4
  • 34
    • 77749306609 scopus 로고    scopus 로고
    • Thermal control microsystem for protein characterization and sensing
    • Beijing, China, Nov.
    • X. Liu, L. Li, and A. J. Mason, "Thermal control microsystem for protein characterization and sensing," in Proc. IEEE Biomedical Circuits Systems Conf., Beijing, China, Nov. 2009, pp. 277-280.
    • (2009) Proc. IEEE Biomedical Circuits Systems Conf. , pp. 277-280
    • Liu, X.1    Li, L.2    Mason, A.J.3
  • 36
    • 77955358821 scopus 로고    scopus 로고
    • Wafer-level parylene packaging with integrated RF electronics for wireless retinal prostheses
    • Aug.
    • W. Li et al., "Wafer-level parylene packaging with integrated RF electronics for wireless retinal prostheses," IEEE J. Microelectromech. Syst., vol. 19, no. 19, pp. 735-742, Aug. 2010.
    • (2010) IEEE J. Microelectromech. Syst. , vol.19 , Issue.19 , pp. 735-742
    • Li, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.