메뉴 건너뛰기




Volumn 66, Issue 4, 2011, Pages 489-497

Free breathing 2D multi-slice real-time gradient-echo cardiovascular magnetic resonance imaging: Impact on left ventricular function measurements compared with standard multi-breath hold 2D steady-state free precession imaging

Author keywords

Automated contour detection; Cardiovascular magnetic resonance imaging; Fast imaging; Real time imaging; Steady state free precession imaging (SSFP); Ventricular function

Indexed keywords

ADULT; AGED; ARTICLE; BREATH HOLDING; BREATHING; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; DIAGNOSTIC IMAGING; FEMALE; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HUMAN; IMAGE QUALITY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; REAL TIME ECHOGRAPHY; STEADY STATE FREE PRECESSION IMAGING; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 80052005011     PISSN: 00015385     EISSN: None     Source Type: Journal    
DOI: 10.2143/AC.66.4.2126598     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 0033879659 scopus 로고    scopus 로고
    • Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?
    • Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJ, Cleland JG, Pennell DJ. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 2000; 21: 1387-1396.
    • (2000) Eur Heart J , vol.21 , pp. 1387-1396
    • Bellenger, N.G.1    Burgess, M.I.2    Ray, S.G.3    Lahiri, A.4    Coats, A.J.5    Cleland, J.G.6    Pennell, D.J.7
  • 2
    • 0034517838 scopus 로고    scopus 로고
    • Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance
    • Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2000; 2: 271-278.
    • (2000) J Cardiovasc Magn Reson , vol.2 , pp. 271-278
    • Bellenger, N.G.1    Davies, L.C.2    Francis, J.M.3    Coats, A.J.4    Pennell, D.J.5
  • 3
    • 0842304408 scopus 로고    scopus 로고
    • Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance
    • Grothues F, Moon JC, Bellenger NG, Smith GS, Klein HU, Pennell DJ. Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J 2004; 147: 218-223.
    • (2004) Am Heart J , vol.147 , pp. 218-223
    • Grothues, F.1    Moon, J.C.2    Bellenger, N.G.3    Smith, G.S.4    Klein, H.U.5    Pennell, D.J.6
  • 4
    • 0036642629 scopus 로고    scopus 로고
    • Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    • Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 2002; 90: 29-34.
    • (2002) Am J Cardiol , vol.90 , pp. 29-34
    • Grothues, F.1    Smith, G.C.2    Moon, J.C.3    Bellenger, N.G.4    Collins, P.5    Klein, H.U.6    Pennell, D.J.7
  • 5
    • 28944439999 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance in the quantitative assessment of left ventricular mass, volumes and contractile function
    • Lyne JC, Pennell DJ. Cardiovascular magnetic resonance in the quantitative assessment of left ventricular mass, volumes and contractile function. Coron Artery Dis 2005; 16: 337-343.
    • (2005) Coron Artery Dis , vol.16 , pp. 337-343
    • Lyne, J.C.1    Pennell, D.J.2
  • 6
    • 28844478451 scopus 로고    scopus 로고
    • Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging
    • Hudsmith LE, Petersen SE, Francis JM, Robson MD, Neubauer S. Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging. J Cardiovasc Magn Reson 2005; 7: 775-782.
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 775-782
    • Hudsmith, L.E.1    Petersen, S.E.2    Francis, J.M.3    Robson, M.D.4    Neubauer, S.5
  • 7
    • 33845313632 scopus 로고    scopus 로고
    • Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance
    • Maceira AM, Prasad SK, Khan M, Pennell DJ. Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J 2006; 27: 2879-2888.
    • (2006) Eur Heart J , vol.27 , pp. 2879-2888
    • Maceira, A.M.1    Prasad, S.K.2    Khan, M.3    Pennell, D.J.4
  • 8
    • 33745889016 scopus 로고    scopus 로고
    • Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance
    • Maceira AM, Prasad SK, Khan M, Pennell DJ. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2006; 8: 417-426.
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 417-426
    • Maceira, A.M.1    Prasad, S.K.2    Khan, M.3    Pennell, D.J.4
  • 9
    • 51649099259 scopus 로고    scopus 로고
    • Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: Board of trustees task force on standardized protocols
    • Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E. Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols. J Cardiovasc Magn Reson 2008; 10: 35.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 35
    • Kramer, C.M.1    Barkhausen, J.2    Flamm, S.D.3    Kim, R.J.4    Nagel, E.5
  • 10
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001; 28: 1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 11
    • 0043136288 scopus 로고    scopus 로고
    • Single breath-hold real-time cine MR imaging: Improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm
    • Wintersperger BJ, Nikolaou K, Dietrich O, Rieber J, Nittka M, Reiser MF, Schoenberg SO. Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 2003; 13: 1931-1936.
    • (2003) Eur Radiol , vol.13 , pp. 1931-1936
    • Wintersperger, B.J.1    Nikolaou, K.2    Dietrich, O.3    Rieber, J.4    Nittka, M.5    Reiser, M.F.6    Schoenberg, S.O.7
  • 12
    • 1542373642 scopus 로고    scopus 로고
    • Impact of papillary muscles in ventricular volume and ejection fraction assessment by cardiovascular magnetic resonance
    • Sievers B, Kirchberg S, Bakan A, Franken U, Trappe HJ. Impact of papillary muscles in ventricular volume and ejection fraction assessment by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2004; 6: 9-16.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 9-16
    • Sievers, B.1    Kirchberg, S.2    Bakan, A.3    Franken, U.4    Trappe, H.J.5
  • 13
    • 43049160749 scopus 로고    scopus 로고
    • Left ventricular papillary muscles and trabeculae are significant determinants of cardiac MRI volumetric measurements: Effects on clinical standards in patients with advanced systolic dysfunction
    • Weinsaft JW, Cham MD, Janik M, Min JK, Henschke CI, Yankelevitz DF, Devereux RB. Left ventricular papillary muscles and trabeculae are significant determinants of cardiac MRI volumetric measurements: effects on clinical standards in patients with advanced systolic dysfunction. Int J Cardiol 2008; 126: 359-365.
    • (2008) Int J Cardiol , vol.126 , pp. 359-365
    • Weinsaft, J.W.1    Cham, M.D.2    Janik, M.3    Min, J.K.4    Henschke, C.I.5    Yankelevitz, D.F.6    Devereux, R.B.7
  • 14
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985; 12: 232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 15
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides CD, Atalar E, McVeigh ER. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 1997; 38: 852-857.
    • (1997) Magn Reson Med , vol.38 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 51549115936 scopus 로고    scopus 로고
    • Effects of papillary muscles and trabeculae on left ventricular quantification: Increased impact of methodological variability in patients with left ventricular hypertrophy
    • Janik M, Cham MD, Ross MI, Wang Y, Codella N, Min JK, Prince MR, Manoushagian S, Okin PM, Devereux RB, Weinsaft JW. Effects of papillary muscles and trabeculae on left ventricular quantification: increased impact of methodological variability in patients with left ventricular hypertrophy. J Hypertens 2008; 26: 1677-1685.
    • (2008) J Hypertens , vol.26 , pp. 1677-1685
    • Janik, M.1    Cham, M.D.2    Ross, M.I.3    Wang, Y.4    Codella, N.5    Min, J.K.6    Prince, M.R.7    Manoushagian, S.8    Okin, P.M.9    Devereux, R.B.10    Weinsaft, J.W.11
  • 19
    • 51549106357 scopus 로고    scopus 로고
    • Real-time assessment of right and left ventricular volumes and function in patients with congenital heart disease by using high spatiotemporal resolution radial k-t SENSE
    • Muthurangu V, Lurz P, Critchely JD, Deanfield JE, Taylor AM, Hansen MS. Real-time assessment of right and left ventricular volumes and function in patients with congenital heart disease by using high spatiotemporal resolution radial k-t SENSE. Radiology 2008; 248: 782-791.
    • (2008) Radiology , vol.248 , pp. 782-791
    • Muthurangu, V.1    Lurz, P.2    Critchely, J.D.3    Deanfield, J.E.4    Taylor, A.M.5    Hansen, M.S.6
  • 20
    • 0035178084 scopus 로고    scopus 로고
    • Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography
    • Schalla S, Nagel E, Lehmkuhl H, Klein C, Bornstedt A, Schnackenburg B, Schneider U, Fleck E. Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. Am J Cardiol 2001; 87: 95-99.
    • (2001) Am J Cardiol , vol.87 , pp. 95-99
    • Schalla, S.1    Nagel, E.2    Lehmkuhl, H.3    Klein, C.4    Bornstedt, A.5    Schnackenburg, B.6    Schneider, U.7    Fleck, E.8
  • 23
    • 21244461569 scopus 로고    scopus 로고
    • Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients
    • Narayan G, Nayak K, Pauly J, Hu B. Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients. J Magn Reson Imaging 2005; 22: 59-66.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 59-66
    • Narayan, G.1    Nayak, K.2    Pauly, J.3    Hu, B.4
  • 27
    • 77952875698 scopus 로고    scopus 로고
    • Assessment of Left Ventricular Function With Single Breath-hold Highly Accelerated Cine MRI Combined With Guide-point Modeling
    • Heilmaier C, Nassenstein K, Nielles-Vallespin S, Zuehlsdorff S, Hunold P, Barkhausen J. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling. Eur J Radiol 2010; 74: 492-499.
    • (2010) Eur J Radiol , vol.74 , pp. 492-499
    • Heilmaier, C.1    Nassenstein, K.2    Nielles-Vallespin, S.3    Zuehlsdorff, S.4    Hunold, P.5    Barkhausen, J.6
  • 28
    • 33750374573 scopus 로고    scopus 로고
    • Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold
    • Mascarenhas NB, Muthupillai R, Cheong B, Pereyra M, Flamm SD. Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold. AJR Am J Roentgenol 2006; 187: 1235-1239.
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1235-1239
    • Mascarenhas, N.B.1    Muthupillai, R.2    Cheong, B.3    Pereyra, M.4    Flamm, S.D.5
  • 29
    • 63449086330 scopus 로고    scopus 로고
    • Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: Validation and clinical feasibility
    • Corsi C, Veronesi F, Lamberti C, Bardo DM, Jamison EB, Lang RM, Mor-Avi V. Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: validation and clinical feasibility. J Magn Reson Imaging 2009; 29: 560-568.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 560-568
    • Corsi, C.1    Veronesi, F.2    Lamberti, C.3    Bardo, D.M.4    Jamison, E.B.5    Lang, R.M.6    Mor-Avi, V.7
  • 30
    • 33745127684 scopus 로고    scopus 로고
    • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection
    • van Geuns RJ, Baks T, Gronenschild EH, Aben JP, Wielopolski PA, Cademartiri F, de Feyter PJ. Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection. Radiology 2006; 240: 215-221.
    • (2006) Radiology , vol.240 , pp. 215-221
    • van Geuns, R.J.1    Baks, T.2    Gronenschild, E.H.3    Aben, J.P.4    Wielopolski, P.A.5    Cademartiri, F.6    de Feyter, P.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.