메뉴 건너뛰기




Volumn 27, Issue 3, 2008, Pages 510-515

Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST)

Author keywords

Ejection fraction; k t BLAST; Left ventricular mass; Left ventricular volumes; Magnetic resonance imaging (MRI); Myocardial function

Indexed keywords

ACCURACY; ADULT; ARTICLE; BREATH HOLDING; CONFIDENCE INTERVAL; CORRELATION COEFFICIENT; DIAGNOSTIC IMAGING; FEMALE; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGING SYSTEM; INTERMETHOD COMPARISON; KAPPA T SPACE BROAD USE LINEAR ACQUISITION SPEED UP IMAGING; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; THREE DIMENSIONAL CINE STEADY STATE FREE PRECESSION; THREE DIMENSIONAL IMAGING; TIME; VOLUNTEER;

EID: 40449090449     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21200     Document Type: Article
Times cited : (30)

References (25)
  • 1
    • 0020526130 scopus 로고    scopus 로고
    • Risk stratification and survival after myocardial infarction. N Engl J Med 1983;309:331-336.
    • Risk stratification and survival after myocardial infarction. N Engl J Med 1983;309:331-336.
  • 2
    • 0000531635 scopus 로고    scopus 로고
    • Cardiovascular death and left ventricular remodeling two years after myocardial infarction: Baseline predictors and impact of long-term use of captopril: information from the Survival and Ventricular Enlargement (SAVE) trial
    • St John SM, Pfeffer MA, Moye L, et al. Cardiovascular death and left ventricular remodeling two years after myocardial infarction: baseline predictors and impact of long-term use of captopril: information from the Survival and Ventricular Enlargement (SAVE) trial. Circulation 1997;96:3294-3299.
    • (1997) Circulation , vol.96 , pp. 3294-3299
    • St John, S.M.1    Pfeffer, M.A.2    Moye, L.3
  • 3
    • 0034517838 scopus 로고    scopus 로고
    • Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance
    • Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2000;2:271-278.
    • (2000) J Cardiovasc Magn Reson , vol.2 , pp. 271-278
    • Bellenger, N.G.1    Davies, L.C.2    Francis, J.M.3    Coats, A.J.4    Pennell, D.J.5
  • 4
    • 0012710659 scopus 로고    scopus 로고
    • Assessment of cardiac function
    • Manning WJ, Pennell DJ, editors, 1st edition. Philadelphia: Churchill Livingstone;
    • Bellenger NG, Pennell DJ. Assessment of cardiac function. In: Manning WJ, Pennell DJ, editors. Cardiovascular magnetic resonance. 1st edition. Philadelphia: Churchill Livingstone; 2002. p 103.
    • (2002) Cardiovascular magnetic resonance , pp. 103
    • Bellenger, N.G.1    Pennell, D.J.2
  • 5
    • 0002332264 scopus 로고    scopus 로고
    • Echocardiography and Doppler ultrasound
    • Garson A, Bricker JT, Fisher DJ, Neish SR, editors, 2nd edition. Philadelphia: Williams & Wilkins;
    • Geva T. Echocardiography and Doppler ultrasound. In: Garson A, Bricker JT, Fisher DJ, Neish SR, editors. The science and practice of pediatric cardiology, 2nd edition. Philadelphia: Williams & Wilkins; 1997. p 832 ff.
    • (1997) The science and practice of pediatric cardiology
    • Geva, T.1
  • 6
    • 0036206953 scopus 로고    scopus 로고
    • MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters
    • Miller S, Simonetti OP, Carr J, Kramer U, Finn JP. MR imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 2002;223:263-269.
    • (2002) Radiology , vol.223 , pp. 263-269
    • Miller, S.1    Simonetti, O.P.2    Carr, J.3    Kramer, U.4    Finn, J.P.5
  • 7
    • 0036104746 scopus 로고    scopus 로고
    • Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ. Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular differences and reproducibility. Radiology 2002;223.789-797.
    • Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ. Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 2002;223.789-797.
  • 8
    • 19944434275 scopus 로고    scopus 로고
    • Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences
    • Kunz RP, Oellig F, Krummenauer F, et al. Assessment of left ventricular function by breath-hold cine MR imaging: comparison of different steady-state free precession sequences. J Magn Reson Imaging 2005;21:140-148.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 140-148
    • Kunz, R.P.1    Oellig, F.2    Krummenauer, F.3
  • 9
    • 0032731734 scopus 로고    scopus 로고
    • MR imaging of the heart in patients after myocardial infarction: Effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness
    • Cottin Y, Touzery C, Guy F, et al. MR imaging of the heart in patients after myocardial infarction: effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness. Radiology 1999;213:513-520.
    • (1999) Radiology , vol.213 , pp. 513-520
    • Cottin, Y.1    Touzery, C.2    Guy, F.3
  • 11
  • 12
    • 4444266832 scopus 로고    scopus 로고
    • Reduced data acquisition methods in cardiac imaging
    • Kozerke S, Tsao J. Reduced data acquisition methods in cardiac imaging. Top Magn Reson Imaging 2004;15:161-168.
    • (2004) Top Magn Reson Imaging , vol.15 , pp. 161-168
    • Kozerke, S.1    Tsao, J.2
  • 13
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 14
    • 0030966347 scopus 로고    scopus 로고
    • Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
    • McConnell MV, Khasgiwala VC, Savord BJ, et al. Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol 1997;168:1369-1375.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 1369-1375
    • McConnell, M.V.1    Khasgiwala, V.C.2    Savord, B.J.3
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-trueFISP cine cardiac imaging
    • Jung BA, Hennig J, Scheffler K. Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 2002;48:921-925.
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 18
    • 20044385076 scopus 로고    scopus 로고
    • Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models
    • Corsi C, Lamberti C, Catalano O, et al. Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models. J Cardiovasc Magn Reson 2005;7:595-602.
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 595-602
    • Corsi, C.1    Lamberti, C.2    Catalano, O.3
  • 20
    • 0037373294 scopus 로고    scopus 로고
    • Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    • Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU. Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 2003;17:323-329.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 323-329
    • Alfakih, K.1    Plein, S.2    Thiele, H.3    Jones, T.4    Ridgway, J.P.5    Sivananthan, M.U.6
  • 21
    • 0038787546 scopus 로고    scopus 로고
    • Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging
    • Alfakih K, Plein S, Bloomer T, Jones T, Ridgway J, Sivananthan M. Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging. J Magn Reson Imaging 2003;18:25-32.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 25-32
    • Alfakih, K.1    Plein, S.2    Bloomer, T.3    Jones, T.4    Ridgway, J.5    Sivananthan, M.6
  • 22
    • 0037227771 scopus 로고    scopus 로고
    • Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA
    • Huber ME, Paetsch I, Schnackenburg B, et al. Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA. Magn Reson Med 2003;49:115-121.
    • (2003) Magn Reson Med , vol.49 , pp. 115-121
    • Huber, M.E.1    Paetsch, I.2    Schnackenburg, B.3
  • 23
    • 3242757471 scopus 로고    scopus 로고
    • Improved three-dimensional free-breathing coronary magnetic resonance angiography using gadocoletic acid (B-22956) for intravascular contrast enhancement
    • Paetsch I, Huber ME, Bornstedt A, et al. Improved three-dimensional free-breathing coronary magnetic resonance angiography using gadocoletic acid (B-22956) for intravascular contrast enhancement. J Magn Reson Imaging 2004;20:288-293.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 288-293
    • Paetsch, I.1    Huber, M.E.2    Bornstedt, A.3
  • 24
    • 0036708122 scopus 로고    scopus 로고
    • Preliminary report on in vivo coronary MRA at 3 Tesla in humans
    • Stuber M, Botnar RM, Fischer SE, et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 2002;48:425-429.
    • (2002) Magn Reson Med , vol.48 , pp. 425-429
    • Stuber, M.1    Botnar, R.M.2    Fischer, S.E.3
  • 25
    • 31944444882 scopus 로고    scopus 로고
    • Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: Impact of acceleration factors on image quality and volumetric accuracy
    • Wintersperger BJ, Reeder SB, Nikolaou K, et al. Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy. J Magn Reson Imaging 2006;23:222-227.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 222-227
    • Wintersperger, B.J.1    Reeder, S.B.2    Nikolaou, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.