메뉴 건너뛰기




Volumn 13, Issue 8, 2003, Pages 1931-1936

Single breath-hold real-time cine MR imaging: Improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm

Author keywords

Heart; Heart volume; MR; MR cine study; MR volume measurement

Indexed keywords

ALGORITHM; ARTICLE; BREATH HOLDING; CALIBRATION; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; HEART DISEASE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART VOLUME; HUMAN; IMAGING SYSTEM; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; STEADY STATE;

EID: 0043136288     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-003-1982-9     Document Type: Article
Times cited : (86)

References (19)
  • 1
    • 0036178522 scopus 로고    scopus 로고
    • Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR imaging
    • Barkhausen J, Goyen M, Ruhm SG, Eggebrecht H, Debatin JF, Ladd ME (2002) Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR imaging. Am J Roentgenol 178:731-735
    • (2002) Am. J. Roentgenol. , vol.178 , pp. 731-735
    • Barkhausen, J.1    Goyen, M.2    Ruhm, S.G.3    Eggebrecht, H.4    Debatin, J.F.5    Ladd, M.E.6
  • 2
    • 0036511609 scopus 로고    scopus 로고
    • Cardiac function: MR evaluation in one breath-hold with real-time true fast imaging with steady-state precession
    • Lee VS, Resnick D, Bundy JM, Simonetti OP, Lee P, Weinreb JC (2002) Cardiac function: MR evaluation in one breath-hold with real-time true fast imaging with steady-state precession. Radiology 222:835-842
    • (2002) Radiology , vol.222 , pp. 835-842
    • Lee, V.S.1    Resnick, D.2    Bundy, J.M.3    Simonetti, O.P.4    Lee, P.5    Weinreb, J.C.6
  • 3
    • 25344454894 scopus 로고    scopus 로고
    • MRI cardiac function analysis in a single breath-hold: Real-time TrueFISP with improved temporal resolution using integrated parallel acquisition techniques (iPAT)
    • Wintersperger BJ, Nikolaou K, Schoenberg SO, Nittka M, Huber AM, Reiser MF (2002) MRI cardiac function analysis in a single breath-hold: real-time TrueFISP with improved temporal resolution using integrated parallel acquisition techniques (iPAT). Radiology 225:P298
    • (2002) Radiology , vol.225
    • Wintersperger, B.J.1    Nikolaou, K.2    Schoenberg, S.O.3    Nittka, M.4    Huber, A.M.5    Reiser, M.F.6
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breath-hold with a segmented turboFLASH sequence
    • Atkinson DJ, Edelman RR (1991) Cineangiography of the heart in a single breath-hold with a segmented turboFLASH sequence. Radiology 178:357-360
    • (1991) Radiology , vol.178 , pp. 357-360
    • Atkinson, D.J.1    Edelman, R.R.2
  • 9
    • 0035088021 scopus 로고    scopus 로고
    • MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    • Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264-269
    • (2001) Radiology , vol.219 , pp. 264-269
    • Barkhausen, J.1    Ruehm, S.G.2    Goyen, M.3    Buck, T.4    Laub, G.5    Debatin, J.F.6
  • 10
    • 0036104746 scopus 로고    scopus 로고
    • Breathhold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ (2002) Breathhold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 223:789-797
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.C.1    Lorenz, C.H.2    Francis, J.M.3    Smith, G.C.4    Pennell, D.J.5
  • 12
    • 0033845492 scopus 로고    scopus 로고
    • Quantification of left ventricular function with magnetic resonance images acquired in real time
    • Setser RM, Fischer SE, Lorenz CH (2000) Quantification of left ventricular function with magnetic resonance images acquired in real time. J Magn Reson Imaging 12:430-438
    • (2000) J. Magn. Reson. Imaging , vol.12 , pp. 430-438
    • Setser, R.M.1    Fischer, S.E.2    Lorenz, C.H.3
  • 13
    • 0036206953 scopus 로고    scopus 로고
    • MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters
    • Miller S, Simonetti OP, Carr J, Kramer U, Finn JP (2002) MR imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 223:263-269
    • (2002) Radiology , vol.223 , pp. 263-269
    • Miller, S.1    Simonetti, O.P.2    Carr, J.3    Kramer, U.4    Finn, J.P.5
  • 14
    • 0035178084 scopus 로고    scopus 로고
    • Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography
    • Schalla S, Nagel E, Lehmkuhl H, Klein C, Bornstedt A, Schnackenburg B, Schneider U, Fleck E (2001) Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. Am J Cardiol 87:95-99
    • (2001) Am. J. Cardiol. , vol.87 , pp. 95-99
    • Schalla, S.1    Nagel, E.2    Lehmkuhl, H.3    Klein, C.4    Bornstedt, A.5    Schnackenburg, B.6    Schneider, U.7    Fleck, E.8
  • 16
    • 0035184170 scopus 로고    scopus 로고
    • Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging
    • Schaeffter T, Weiss S, Eggers H, Rasche V (2001) Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging. Magn Reson Med 46:1238-1241
    • (2001) Magn. Reson. Med. , vol.46 , pp. 1238-1241
    • Schaeffter, T.1    Weiss, S.2    Eggers, H.3    Rasche, V.4
  • 17
    • 0035180571 scopus 로고    scopus 로고
    • Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout
    • Larson AC, Simonetti OP (2001) Real-time cardiac cine imaging with SPIDER: steady-state projection imaging with dynamic echo-train readout. Magn Reson Med 46:1059-1066
    • (2001) Magn. Reson. Med. , vol.46 , pp. 1059-1066
    • Larson, A.C.1    Simonetti, O.P.2
  • 18
    • 0034951594 scopus 로고    scopus 로고
    • Qualitative and quantitative analysis of regional left ventricular wall dynamics using real-time magnetic resonance imaging: Comparison with conventional breath-hold gradient echo acquisition in volunteers and patients
    • Plein S, Smith WH, Ridgway JP, Kassner A, Beacock DJ, Bloomer TN, Sivananthan MU (2001) Qualitative and quantitative analysis of regional left ventricular wall dynamics using real-time magnetic resonance imaging: comparison with conventional breath-hold gradient echo acquisition in volunteers and patients. J Magn Reson Imaging 14:23-30
    • (2001) J. Magn. Reson. Imaging , vol.14 , pp. 23-30
    • Plein, S.1    Smith, W.H.2    Ridgway, J.P.3    Kassner, A.4    Beacock, D.J.5    Bloomer, T.N.6    Sivananthan, M.U.7
  • 19
    • 25344449323 scopus 로고    scopus 로고
    • High resolution magnetic resonance angiography and fast perfusion imaging in the diagnosis of pulmonary arterial hypertension: Benefit of parallel imaging techniques
    • Nikolaou K, Schoenberg SO, Nittka M, Attenberger U, Behr J, Reiser MF (2003) High resolution magnetic resonance angiography and fast perfusion imaging in the diagnosis of pulmonary arterial hypertension: benefit of parallel imaging techniques. Eur Radiol 13 (Suppl 1):S161
    • (2003) Eur. Radiol. , vol.13 , Issue.SUPPL. 1
    • Nikolaou, K.1    Schoenberg, S.O.2    Nittka, M.3    Attenberger, U.4    Behr, J.5    Reiser, M.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.